Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “science management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Report series: finding of effect and mitigation documentation for the mercury solar photovoltaic array and battery energy storage system, area 23, nevada national security site, nye county, nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) proposes to install solar photovoltaic (PV) power generation arrays and an associated battery energy storage system (BESS) for the town of Mercury at the Nevada National Security Site (NNSS) in Nye County, Nevada (Figure 1). The purposes of the development of this facility are to support long-term efforts to modernize Mercury and to provide energy-resilient infrastructure and address climate adaptation needs. Because it is within the boundary of the Mercury Historic District (MHD), it is subject to the terms of the Programmatic Agreement Between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada (hereafter referred to as the Mercury PA). An identification and evaluation report prepared for this undertaking determined that a contributing element to the MHD, the Mercury airstrip (26NY15777), is within the APE (Haynes 2024). The Mercury airstrip was developed following the closure of Camp Desert Rock in 1957 and used until late 1963 or 1964 when the Camp Desert Rock Airport was renovated, and the Mercury Bypass road constructed. The town of Mercury and the immediate surrounding area have been determined eligible for listing in the National Register of Historic Places (NRHP) as the MHD (SHPO Resource No. D230) under Criteria A and C for its importance in supporting nuclear testing and scientific research from 1951 through 1992 (Reed 2019). Originally recorded in 2016, 26NY15777 was determined individually not eligible for listing in the NRHP because it lacked sufficient integrity to convey its significance (Palmer 2016). It was subsequently determined in 2018 to be a contributing element of the MHD in an architectural survey of the district (Palmer 2018) and identified in Appendix C of the Mercury PA as a Category I contributing element. However, as per Stipulation IV.B.2, because the airstrip had already been formally evaluated and determined not to be individually eligible for the NRHP in consultation with the SHPO, this categorization was an error. NNSA/NFO reported this to the SHPO in Haynes 2024 and the SHPO concurred on June 11, 2024 (Reed). Accordingly, the airstrip is a Category II Property for the purposes of complying with the Mercury PA. The Mercury airstrip is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA.

25 ENERGY STORAGE↗

Identification and evaluation for the mercury solar photovoltaic array and battery energy storage system, area 23, nevada national security site, nye county, nevada

The U.S. Department of Energy (DOE), in conjunction with the National Nuclear Security Administration Nevada Field Office (NNSA/NFO), proposes to construct a solar photovoltaic (PV) energy generation array and an associated Battery Energy Storage System (BESS) in the town of Mercury at the Nevada National Security Site (NNSS) in Nye County, Nevada. The purposes of the development of this facility are to support long-term efforts to modernize Mercury and to provide energy-resilient infrastructure and climate adaptation needs.

25 ENERGY STORAGE↗

Library of Advanced Materials for Engineering (LAMÉ) (V.5.24)

Accurate and efficient constitutive modeling remains a cornerstone issue for solid mechanics analysis. Over the years, the LAMÉ advanced material model library has grown to address this challenge by implementing models capable of describing material systems spanning soft polymers to stiff ceramics including both isotropic and anisotropic responses. Inelastic behaviors including (visco)plasticity, damage, and fracture have all incorporated for use in various analyses. This multitude of options an

36 MATERIALS SCIENCE↗

An Architectural Survey of the U12G Tunnel Historic District, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), in conjunction with the National Nuclear Security Administration Nevada Field Office (NNSA/NFO), proposes to demolish six buildings and three storage areas located at the U12g Tunnel portal area in Area 12 of the Nevada National Security Site (NNSS). The buildings are 12-358 (Signal Vault); 12-201800 (Storage Quonset Hut); 12-202555 (Walker Shack); 12-868 (Pipe Assembly); 12-B100933 (Electrical Shop); 12-B100944 (Conference Room); and Storage Area 1; Storage Area 2; and Storage Area 3. The buildings and storage areas were selected for demolition as part of the DOE’s Real Property Efficiency Plan to reduce the footprint of unused and non-operational facilities on the NNSS. They are all vacant and have no proposed uses for current or upcoming NNSS missions. Demolition activities constitute an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. Identification efforts began with resources proposed for demolition in federal Fiscal Year (FY) 23. Four buildings were proposed to be demolished in FY23 (12-358, 12-868, 12-201800, and 12-202555). These buildings and the U12g Tunnel Historic District (SHPO No. D444) were recorded in Identification, Evaluation, and Finding of Adverse Effect for the Proposed Demolition of Five Buildings in Area 12, Nevada National Security Site, Nye County, Nevada (Menocal et al. 2023). Identification efforts indicated three buildings (12-358, 12-201800, and 12-868) supported nuclear testing in the U12g Tunnel. The fourth building post-dated the use of U12g Tunnel for nuclear testing activities. The report recommended that three of the four buildings (12-358, 12-201800, 12-868) and the U12g Tunnel Historic District may be eligible for the National Register of Historic Places (NRHP). The report also found that the undertaking would have an adverse effect on the three buildings and on the historic district. The Nevada State Historic Preservation Office (SHPO) concurred with the report’s findings (Reed 2023). The U12g Tunnel was determined eligible as a historic district under the Secretary of the Interior’s (SOI) Significance Criterion A, at the local level, in the context of the Cold War as an underground testing environment for the development of nuclear weapons and to assess the effects of a nuclear explosion on materials and equipment with a period of significance from 1959 to 1971. It was also determined eligible under Significance Criterion C for embodying the distinctive characters of a horizontal tunnel complex used for nuclear testing and as a significant and distinguishable entity. The three buildings were determined to be contributing elements of the district. The undertaking was expanded with the addition of two buildings and three storage areas proposed to be demolished and located within U12g Tunnel Historic District in FY24. These five resources (12-B100933, 12-B100944, and Storage Areas 1, 2, and 3) were recorded in Supplemental Identification, Evaluation, and Finding of Effect for Additional Proposed Demolition at U12g Tunnel, Area 12, Nevada national Security Site, Nye County, Nevada (Brannan et al. 2024). Identification efforts indicated that the two buildings and Storage Area 1 supported nuclear testing in the U12g Tunnel. Storage Area 1 and Storage Area 2 post-dated the nuclear testing activities at U12g Tunnel and were not recommended as contributing elements to the district. The report also found that the undertaking would have an adverse effect on the newly identified buildings and one storage area and on the historic district. The SHPO concurred that the expanded undertaking would result in adverse effects to historic properties (Reed 2025). To resolve these adverse effects, NNSA/NFO, in consultation with the SHPO, is following standard mitigation as stipulated in the 2024 Programmatic Agreement DE-GM58-22NA25554 Among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (hereafter referred to as the NNSS PA). The standard mitigation measures are outlined in Appendix D of the NNSS PA. As such, this architectural survey has been prepared in accordance with Appendix D of the NNSS PA and follows the report format outlined in Appendix F. It includes a historic context that describes the district’s origin, history, and support functions, its significance in the context of nuclear testing on the NNSS, and identifies contributing and non-contributing elements within the district. The report is accompanied by Architectural Resource Assessment (ARA) forms for individual resources and a Historic District Resource Assessment (HDRA) for the U12g Tunnel Historic District. In total, this architectural report identified 32 primary resources within the district boundary. Six of the primary resources were previously identified as contributing elements. An additional 17 resources are recommended as contributing elements to the district for a total of 23 contributing elements. The other nine resources identified are recommended as non-contributing elements to the district.

12-201800↗

Automated qualification data tool for high temperature metallic materials

This report describes a framework for storing, processing, and displaying qualification data for high temperature mechanical properties. The framework automates the process of generating design data from mechanical test results, for example for a data qualification report for the ASME Boiler \& Pressure Vessel Code. The framework has three parts: a data storage model with common formats for several types of typical mechanical property tests, a backend based on the \pycreep Python library for correlating and extrapolating the data to generate design material properties and allowable stresses, and a demonstration user interface for displaying, sorting, and filtering the data and exploring different options for modeling the design mechanical properties. The report discusses the options available for data processing, with illustrations from real test data on Alloy 617, Alloy 709, Alloy 740H, and Laser-Powder Bed Fusion 316H. The framework is complete for ASME type data analysis and will be used to store test data generated by the Department of Energy, Office of Nuclear Energy, Advanced Materials and Manufacturing Technologies sponsored qualification programs. Future work could extend the tool to other types of material properties and/or expand the demo user interface to make it accessible across the AMMT program.

36 MATERIALS SCIENCE↗

A section 110 evaluation of the huron king test chamber, area 3, nevada national security site, nye county, nevada

The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office tasked Desert Research Institute (DRI) with the identification and evaluation of the Huron King Test Chamber as part of their cultural resources program obligations under Section 110 of the National Historic Preservation Act. The Huron King nuclear test was a vertical line-of-sight weapons effects test that took place in Area 3 on June 24, 1980. Unique to this event was a specially designed aboveground test chamber that held a model defense communications satellite in a vacuum tank meant to replicate the space environment. Sponsored by the Defense Nuclear Agency, the purpose of the experiment was to understand the response of the satellite and its materials and equipment to an electromagnetic pulse and attendant radiation. Between July and August 2022, DRI conducted an archival review on the Huron King experiment and its associated test chamber. Subsequently, pedestrian fieldwork was undertaken at the Huron King Test Chamber by DRI on September 29, 2022. During fieldwork, the outside of the test chamber was documented using a Nevada State Historic Preservation Office Architectural Resource Assessment form. This effort included verifying the substructures that compose the test chamber as determined by the archival review, as well as obtaining a detailed photographic recordation of the exterior and assessing its current condition. Notably, the site where the Huron King test took place has been abandoned and almost entirely naturalized. All of the portable instrumentation trailers, communications and data cabling, and winch systems used to retract the test chamber following the detonation were removed after completion of the experiment in 1980. Only the subsidence crater and the test chamber remain as physical evidence of this experiment. Based on these findings, DRI recommends that the Huron King Test Chamber is eligible for listing in the National Register of Historic Places (NRHP) at the local level under Significance Criteria A and C and that it meets Criteria Consideration G for properties less than 50 years old.

54 ENVIRONMENTAL SCIENCES↗

Mitigation for roof alterations to building 06-cp-65 at the area 6 control point, nevada national security site, nye county, nevada

Building 06-CP-65 has been determined to be a contributing element to the Area 6 Control Point Historic District (O’Neill et al. 2021; Reed 2022). It contributes to the significance of the historic district under Criterion A as one of the principal buildings that supported timing and firing operations for nuclear testing on the NNSS from 1966 to 1992. As such, the building served as a major warehouse with office space within the district. It was used by both REECo, a long-time general contractor at the NNSS, as well as EG&G, which provided technical support to the national laboratories and the DOD. The building served as an important staging area and electrical power supply point for the NNSS diagnostic trailer fleet and its unique location immediately along Mercury Highway allowed easy accessibility to the forward areas of the NNSS. The building also contributes to the historic district under Criterion C as it is one of the large, unadorned, precast concrete buildings at the Control Point. These types of buildings were the prominent elements of the compound that convey the district’s overall utilitarian, military-industrial character. Building 06-CP-65 retains all aspects of integrity to a high degree and easily conveys its significance as a warehouse that supported Control Point operations. Building 06-CP-65 is not recommended eligible for listing in the NRHP as an individual resource. While it served an important support function as part of the Control Point Historic District, an archival and literature review did not reveal information linking it to any specific test, series of tests, programs, or for any specific role on the NNSS other than as a warehouse (Criterion A). It has no direct association with any important individual (Criterion B). It also is not architecturally significant in its own right beyond reflecting the overall aesthetic of the Control Point Historic District (Criterion C), and it does not have potential to yield information important to the history of nuclear testing beyond what can be learned from historic texts, drawings, and other documents (Criterion D).

54 ENVIRONMENTAL SCIENCES↗

Determination of Scale Bar for AGHCF Metallography Data

The DOE Nuclear Energy Advanced Reactor Technologies (ART) Fast Reactor Program (FRP) has supported the development of several databases containing information on the safety performance of fast reactors, components, and fuels. This growing collection of legacy experimental data, operating data, and analysis is available online to registered users. Metallography data represents one of the most critical types of post-irradiation examination (PIE) data being collected, organized, and archived in several ART Fast Reactor Databases (https://frdb.ne.anl.gov), including the Metallic Fuels Irradiation & Physics Database (FIPD), Out-of-Pile Transient Database (OPTD), and TREAT (the Transient Reactor Test Facility) Experimental Relational Database (TREXR). These databases contain three principal sets of metallography data. The first set comprises metallography data from Experimental Breeder Reactor-II (EBR-II) and Fast Flux Test Facility (FFTF) irradiated fuel pins examined in the Hot Fuel Examination Facility (HFEF). The second set consists of metallography data from EBR-II irradiated fuel pins examined in the Alpha-Gamma Hot Cell Facility (AGHCF). The third set includes metallography data from transient-tested fuel pins (including both out-of-pile furnace tests and TREAT tests) examined in AGHCF. Since both the second and third sets were generated in AGHCF, they are governed by identical specifications. The metallography data in the databases consist of digital images scanned from either positive or negative photographic films. To analyze the microstructure of a fuel pin, a series of preparatory steps are required, including sectioning, epoxy mounting, mechanical grinding and polishing, and etching. Following sample preparation, specimens are transferred for metallographic examination. The AGHCF and HFEF metallography data were generated using optical microscopes manufactured by Leitz and Bausch and Lomb (B&L). Images were recorded on Polaroid film at preset magnifications. Magnification verification for the Leitz and B&L metallographs was conducted every two months prior to 1989 and at least every six months from 1989 through the conclusion of the IFR program. Magnifications determined from imaging of microslide standards were compared to the instrument settings for magnifications ranging from 50× to 500×. If the magnifications determined from standards deviated from the instrument settings, adjustments were made to the bellows extension until agreement was achieved. The specifications for AGHCF and HFEF legacy metallography data have been established based on available hard-copy and digital records, most of which have been incorporated into the data repositories associated with FIPD, OPTD, and TREXR. Detailed specifications including hard-copy records, digitized records, cutting diagrams and sectioning schemes, high-magnification photographs, photomosaics (composites), information tags, scale bars, and magnification verification procedures can be found in a separate report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mitigation for the Demolition of Dormitory Buildings 12-32, 12-34, 12-35, and 12-37 in the Area 12 Camp Historic District, Nevada National Security Site, Nye County, Nevada

The purpose of this letter report is to document the mitigation of adverse effects of a proposed undertaking in compliance with the stipulations in the Programmatic Agreement DE-GM58-22NA25554 Among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada, hereafter referred to as the NNSS PA. The proposed undertaking would demolish Buildings 12-32 (State Historic Preservation Office [SHPO] Resource No. B18291), 12-34 (SHPO Resource No. B18292), 12-35 (SHPO Resource No. B18293), and 12-37 (SHPO Resource No. B18294) in the Area 12 Camp Historic District (SHPO Resource No. D372) on the Nevada National Security Site (NNSS). The Area 12 Camp Historic District has been determined eligible for listing in the National Register of Historic Places (NRHP) under Criteria A and C (Reed 2021; Reno et al. 2021).

54 ENVIRONMENTAL SCIENCES↗

National Hydropower Fish Passage Database User's Guide and Methodology

Fish passage facilities are used to mitigate the impacts of hydropower dams on migratory fish in rivers, but information on the location, types, and characteristics of this infrastructure is incomplete at a national scale. Researchers at Oak Ridge National Laboratory partnered with federal agency and industry stakeholders to create the first national-scale database of fish passage infrastructure at U.S. hydropower developments. This database contains information of great value to a broad range of stakeholders; it includes fish passage facility engineering characteristics, targeted fish species, operational schedules, and costs. This data resource addresses a large gap in knowledge of the deployment of fish passage technology and is freely available to members of the hydropower community, including federal and state regulators and resource agencies, non-governmental organizations, industry, and other user groups to support project planning and regulatory (re)licensing activities. This database supports the U.S. Department of Energy Water Power Technologies Office objective to develop decision support tools and data resources that improve environmental performance and ensure hydropower’s long-term value to the American public.

13 HYDRO ENERGY↗

Library of Advanced Materials for Engineering (LAMÉ) 5.28

Accurate and efficient constitutive modeling remains a cornerstone issue for solid mechanics analysis. Over the years, the LAMÉ advanced material model library has grown to address this challenge by implementing models capable of describing material systems spanning soft polymers to stiff ceramics including both isotropic and anisotropic responses. Inelastic behaviors including (visco)plasticity, damage, and fracture have all incorporated for use in various analyses. This multitude of options and flexibility, however, comes at the cost of many capabilities, features, and responses and the ensuing complexity in the resulting implementation. Therefore, to enhance confidence and enable the utilization of the LAMÉ library in application, this effort seeks to document and verify the various models in the LAMÉ library. Specifically, the broader strategy, organization, and interface of the library itself is first presented. The physical theory, numerical implementation, and user guide for a large set of models is then discussed. Importantly, a number of verification tests are performed with each model to not only have confidence in the model itself but also highlight some important response characteristics and features that may be of interest to end-users. Finally, in looking ahead to the future, approaches to add material models to this library and further expand the capabilities are presented.

36 MATERIALS SCIENCE↗

Outcomes of PAX sapiens-Supported Global Wildlife Data Sharing Conferences for Enhanced One Health Security (GWDSC)

Across two consecutive Global Wildlife Data Sharing Conferences supported by PAX sapiens—Year 1 (May 2024) at Pacific Northwest National Laboratory and Year 2 (2025) in Ciudad Real, Spain—the initiative converted wildlife data sharing from aspiration into operational reality, producing measurable impacts in platform development, data mobilization, standards harmonization, and international partnership formation. The conferences addressed a critical gap in global health security: while 75% of emerging infectious diseases affect both humans and animals and over 60% originate in wildlife, wildlife health surveillance has historically lagged behind human and agricultural sectors due to fragmented databases, inconsistent terminology, uneven capacity, and limited cross-border coordination. By convening practitioners, government agencies, international organizations, academic institutions, and NGOs, the GWDSC catalyzed trust-based relationships and practical workflows that enable earlier detection, better risk assessment, and more effective prevention of threats at the wildlife–domestic animal–human–environment interface.

54 ENVIRONMENTAL SCIENCES↗

Mitigation documentation for the removal of hazardous materials from the engine installation vehicle and manned control car area 25, Nevada national security site, NYE county, Nevada

The purpose of this letter report is to document the mitigation of adverse effects of a proposed undertaking that would remove hazardous materials from the Engine Installation Vehicle (EIV) in Area 25 of the Nevada National Security Site (NNNSS) in compliance with Section 106 of the National Historic Preservation Act (NHPA) and the terms of the 2024 Programmatic Agreement among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada, hereafter referred to as the NNSS PA. The EIV (State Historic Preservation Office [SHPO] Resource No. S3057) has been determined individually eligible for listing in the National Register of Historic Places (NRHP) under Criteria A and C and as a contributing element to the Nuclear Rocket Development Station (NRDS) Historic District, which is eligible for the NRHP under all four Significance Criteria (Reno et al. 2023; Reed 2024).

54 ENVIRONMENTAL SCIENCES↗

Mitigation for the demolition of the foundation of building 25-3113/3113a, area 25, Nevada national security site, NYE county, Nevada

The purpose of this letter report is to document the mitigation of adverse effects of a proposed undertaking that would demolish the foundation of Building 25-3113/3113A and the adjoining test pad at Test Cell A in Area 25 of the Nevada National Security Site (NNSS) in compliance with the terms of the 2024 Programmatic Agreement among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (NNSS PA). The foundation of Building 25-3113/3113A (State Historic Preservation Office [SHPO] Resource # B2443) is a contributing element to the Nuclear Rocket Development Station (NRDS) Historic District (SHPO Resource # D424), which has been determined eligible for listing in the National Register of Historic Places (NRHP) under Criteria A, B, C, and D (Reno et al. 2023). The proposed demolition constitutes an adverse effect. The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) consulted with the SHPO on an adverse effect finding for the undertaking and notified the SHPO of its intent to use the standard mitigation in the NNSS PA on December 11, 2024 (Julian to Reed). The SHPO concurred on December 30, 2024 (Reed to Julian). Therefore, NNSA/NFO has prepared mitigation pursuant to the standard mitigation in the NNSS PA Appendix D.I.A for contributing elements to recorded, NRHP-eligible districts.

#B2443↗

Mitigation for the demolition of building 25-3124,equipment testing laboratory, area 25, Nevada national security site, NYE county, Nevada

The purpose of this letter report is to document the mitigation of adverse effects of a proposed undertaking that would demolish Building 25-3124 in Area 25 of the Nevada National Security Site (NNSS) in compliance with the terms of the 2024 Programmatic Agreement among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (NNSS PA). Building 25-3124 (State Historic Preservation Office [SHPO] Resource # B19009) is a contributing element to the Nuclear Rocket Development Station (NRDS) Historic District (SHPO Resource # D424), which has been determined eligible for listing in the National Register of Historic Places (NRHP) under Criteria A, B, C, and D (Reno et al. 2023). The proposed demolition constitutes an adverse effect. The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) consulted with the SHPO on an adverse effect finding for the undertaking and notified the SHPO of its intent to use the standard mitigation in the NNSS PA on December 11, 2024 (Julian to Reed). The SHPO concurred on December 30, 2024 (Reed to Julian). Therefore, NNSA/NFO has prepared mitigation pursuant to the standard mitigation in the NNSS PA Appendix D.I.A for contributing elements to recorded, NRHP-eligible districts.

#B19009↗

Mitigation for the demolition of building 25-3153, fire station, area 25, Nevada national security site, NYE county, Nevada

The purpose of this letter report is to document the mitigation of adverse effects of a proposed undertaking that would demolish Building 25-3153 in Area 25 of the Nevada National Security Site (NNSS) in compliance with the terms of the 2024 Programmatic Agreement among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (NNSS PA). Building 25-3153 (State Historic Preservation Office [SHPO] Resource # B19004) is a contributing element to the Nuclear Rocket Development Station (NRDS) Historic District (SHPO Resource # D424), which has been determined eligible for listing in the National Register of Historic Places (NRHP) under Criteria A, B, C, and D (Reno et al. 2023). The proposed demolition constitutes an adverse effect. The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) consulted with the SHPO on an adverse effect finding for the undertaking and notified the SHPO of its intent to use the standard mitigation in the NNSS PA on December 11, 2024 (Julian to Reed). The SHPO concurred on December 30, 2024 (Reed to Julian). Therefore, NNSA/NFO has prepared mitigation pursuant to the standard mitigation in the NNSS PA Appendix D.I.A for contributing elements to recorded, NRHP-eligible districts.

#B19004↗

Mitigation for the demolition of building 25-4314, radiation services, area 25, Nevada national security site, NYE county, Nevada

The purpose of this letter report is to document the mitigation of adverse effects of a proposed undertaking that would demolish Building 25-4314 in Area 25 of the Nevada National Security Site (NNSS) in compliance with the terms of the 2024 Programmatic Agreement among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (NNSS PA). Building 25-4314 (State Historic Preservation Office [SHPO] Resource # B19016) is a contributing element to the Nuclear Rocket Development Station (NRDS) Historic District (SHPO Resource # D424), which has been determined eligible for listing in the National Register of Historic Places (NRHP) under Criteria A, B, C, and D (Reno et al. 2023). The proposed demolition constitutes an adverse effect. The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) consulted with the SHPO on an adverse effect finding for the undertaking and notified the SHPO of its intent to use the standard mitigation in the NNSS PA on December 11, 2024 (Julian to Reed). The SHPO concurred on December 30, 2024 (Reed to Julian). Therefore, NNSA/NFO has prepared mitigation pursuant to the standard mitigation in the NNSS PA Appendix D.I.A for contributing elements to recorded, NRHP-eligible districts.

#B19016↗