Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scattering functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Field experiment to measure the radiative characteristics of a hazy atmosphere

Preliminary results are presented of a field experiment to measure the effect of atmospheric aerosols on the upward radiance at aircraft and satellite altitudes. These measurements, made over Chesapeake Bay, were conducted simultaneously with measurements of aerosol optical characteristics, profile, and spatial distribution. The aerosol vertical optical thickness and the scattering phase function were determined along with profiles of the scattering coefficient, temperatures, and humidity. The results are used to quantify the atmospheric effect on the surface reflectivity as detected from space, including the adjacency effect, and to test theoretical radiative transfer models. The experimental results are also used to test procedures to measure the aerosol optical thickness, the scale height, and the absorption from satellite imagery, and to use the results to correct satellite imagery of the surface. Ground measurements of surface reflectivity and the scattering coefficient at the surface are compared with airborne results.

Kaufman, Y. J.↗

Relationship Between the Atomic Pair Distribution Function and Small-Angle Scattering: Implications for Modeling of Nanoparticles

The relationship between the equations used in the atomic pair distribution function (PDF) method and those commonly used in small-angle-scattering (SAS) analyses is explicitly shown. The origin of the sloping baseline, -4{pi}r{rho}{sub 0}, in PDFs of bulk materials is identified as originating from the SAS intensity that is neglected in PDF measurements. The nonlinear baseline in nanoparticles has the same origin, and contains information about the shape and size of the nanoparticles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A catalogue of normalized intensity functions and polarization from a cloud of particles with a size distribution of alpha to the minus 4th power

The Mie theory of light scattering by spheres was used to calculate the scattered intensity functions resulting from single scattering in a polydispersed collection of spheres. The distribution used behaves according to the inverse fourth power law; graphs and tables for the angular dependence of the intensity and polarization for this law are given. The effects of the particle size range and the integration increment are investigated.

Craven, P. D.↗

Recovering non-Maxwellian particle velocity distribution functions from collective Thomson-scattered spectra

Collective optical Thomson scattering (TS) is a diagnostic commonly used to characterize plasma parameters. These parameters are typically extracted by a fitting algorithm that minimizes the difference between a measured scattered spectrum and an analytic spectrum calculated from the velocity distribution function (VDF) of the plasma. However, most existing TS analysis algorithms assume that the VDFs are Maxwellian, and applying an algorithm that makes this assumption does not accurately extract the plasma parameters of a non-Maxwellian plasma due to the effect of non-Maxwellian deviations on the TS spectra. We present new open-source numerical tools for forward modeling analytic spectra from arbitrary VDFs and show that these tools are able to more accurately extract plasma parameters from synthetic TS spectra generated by non-Maxwellian VDFs compared to standard TS algorithms. Estimated posterior probability distributions of fits to synthetic spectra for a variety of example non-Maxwellian VDFs are used to determine uncertainties in the extracted plasma parameters and show that correlations between parameters can significantly affect the accuracy of fits in plasmas with non-Maxwellian VDFs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral deconvolution without the deconvolution: Extracting temperature from x-ray Thomson scattering spectra without the source-and-instrument function

X-ray Thomson scattering (XRTS) probes the dynamic structure factor of the system, but the measured spectrum is broadened by the combined source-and-instrument function (SIF) of the setup. In order to extract properties such as temperature from an XRTS spectrum, the broadening by the SIF needs to be removed. Recent work [Dornheim et al. Nat. Commun. 13 , 7911 (2022)] has suggested that the SIF may be deconvolved using the two-sided Laplace transform. However, the extracted information can depend strongly on the shape of the input SIF, and the SIF is in practice challenging to measure accurately. Here, we propose an alternative approach: we demonstrate that considering ratios of Laplace-transformed XRTS spectra collected at different scattering angles is equivalent to performing the deconvolution, but without the need for explicit knowledge of the SIF. From these ratios, it is possible to directly extract the temperature from the scattering spectra, when the system is in thermal equilibrium. We find the method to be generally robust to spectral noise and physical differences between the spectrometers, and we explore situations in which the method breaks down. Furthermore, the fact that consistent temperatures can be extracted for systems in thermal equilibrium indicates that non-equilibrium effects could be identified by inconsistent temperatures of a few eV between the ratios of three or more scattering angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaporation and scattering of neon, methane, and water from a dodecane flat liquid jet

The evaporation and scattering of Ne, CD 4 , and D 2 O from a dodecane flat liquid jet are investigated in a molecular beam apparatus. The experiment yields translational energy distributions as a function of scattering angle by means of a rotatable mass spectrometer. In the evaporation experiments, one observes a Maxwell–Boltzmann distribution with a cos $θ$ angular distribution superimposed on a weak, isotropic background. The scattering experiments show contributions from impulsive scattering and thermal desorption. At select incident angles for the three systems, angular distributions show super-specular scattering for the impulsive scattering channel, an effect attributed to anisotropic momentum transfer to the liquid surface. The impulsive scattering channel is analyzed with a soft-sphere model to explore energy transfer between the scatterer and liquid as a function of deflection angle. In conclusion, compared to Ne scattering, the polyatomic gases exhibit more thermal desorption and, in the impulsive scattering channel, a higher degree of internal excitation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MO-FG-CAMPUS-IeP1-01: Alternative K-Edge Filters for Low-Energy Image Acquisition in Contrast Enhanced Spectral Mammography

Purpose: In Contrast Enhanced Spectral Mammography (CESM), Rh filter is often used during low-energy image acquisition. The potential for using Ag, In and Sn filters, which exhibit K-edge closer to, and just below that of Iodine, instead of the Rh filter, was investigated for the low-energy image acquisition. Methods: Analytical computations of the half-value thickness (HVT) and the photon fluence per mAs (photons/mm2/mAs) for 50µm Rh were compared with other potential K-edge filters (Ag, In and Sn), all with K-absorption edge below that of Iodine. Two strategies were investigated: fixed kVp and filter thickness (50µm for all filters) resulting in HVT variation, and fixed kVp and HVT resulting in variation in Ag, In and Sn thickness. Monte Carlo simulations (GEANT4) were conducted to determine if the scatter-to-primary ratio (SPR) and the point spread function of scatter (scatter PSF) differed between Rh and other K-edge filters. Results: Ag, In and Sn filters (50µm thick) increased photon fluence/mAs by 1.3–1.4, 1.8–2, and 1.7–2 at 28-32 kVp compared to 50µm Rh, which could decrease exposure time. Additionally, the fraction of spectra closer to and just below Iodine’s K-edge increased with these filters, which could improve post-subtraction image contrast. For HVT matched to 50µm Rh filtered spectra, the thickness range for Ag, In, and Sn were (41,44)µm, (49,55)µm and (45,53)µm, and increased photon fluence/mAs by 1.5–1.7, 1.6–2, and 1.6–2.2, respectively. Monte Carlo simulations showed that neither the SPR nor the scatter PSF of Ag, In and Sn differed from Rh, indicating no additional detriment due to x-ray scatter. Conclusion: The use of Ag, In and Sn filters for low-energy image acquisition in CESM is potentially feasible and could decrease exposure time and may improve post-subtraction image contrast. Effect of these filters on radiation dose, contrast, noise and associated metrics are being investigated. Funding Support: Supported in part by NIH R01CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

WE-DE-207B-08: Towards Standardization of X-Ray Filters in Digital Mammography-Enabled Breast Tomosynthesis Systems

Purpose: In digital breast tomosynthesis (DBT) systems capable of digital mammography (DM), Al filters are used during DBT and K-edge filters during DM. The potential for standardizing the x-ray filters with Al, instead of K-edge filters, was investigated with intent to reduce exposure duration and to promote a simpler system design. Methods: Analytical computations of the half-value thickness (HVT) and the photon fluence per mAs (photons/mm2/mAs) for K-edge filters (50µm Rh; 50µm Ag) were compared with Al filters of varying thickness. Two strategies for matching the HVT from K-edge and Al filtered spectra were investigated: varying the kVp for fixed Al thickness, or varying the Al thickness at matched kVp. For both strategies, Al filters were an order of magnitude thicker than K-edge filters. Hence, Monte Carlo simulations were conducted with the GEANT4 toolkit to determine if the scatter-to-primary ratio (SPR) and the point spread function of scatter (scatter PSF) differed between Al and K-edge filters. Results: Results show the potential for replacing currently used Kedge filters with Al. For fixed Al thickness (700µm), ±1 kVp and +(1–3) kVp change, matched HVT of Rh and Ag filtered spectra. At matched kVp, Al thickness range (650,750)µm and (750,860)µm matched the HVT from Rh and Ag filtered spectra. Photon fluence/mAs with Al filters were 1.5–2.5 times higher, depending on kVp and Al thickness, compared to K-edge filters. Although Al thickness was an order higher than K-edge filters, neither the SPR nor the scatter PSF differed from K-edge filters. Conclusion: The use of Al filters for digital mammography is potentially feasible. The increased fluence/mAs with Al could decrease exposure duration for the combined DBT+DM exam and simplify system design. Effect of x-ray spectrum change due to Al filtration on radiation dose, signal, noise, contrast and related metrics are being investigated. Funding support: Supported in part by NIH R21CA176470 and R01CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

Effect of Scattering Angle on DSCOVR/EPIC Observations

The Earth Polychromatic Imaging Camera (EPIC) on the Deep Space Climate Observatory (DSCOVR) routinely captures reflected radiation from the whole sunlit side of the Earth in the near backward direction to monitor the changing planet. The instrument had routinely operated until 27 June 2019, when the spacecraft was placed in an extended safe hold due to degradation of an inertial navigation unit. DSCOVR returned to full operations on 2 March 2020. Since then, the range of scattering angles between the incident sunlight and sensor direction has been larger than before and the largest scattering angle reaches ∼178°, only 2° from perfect backscattering, proving a unique opportunity to study the top-of-atmosphere (TOA) reflectance under such extreme conditions. In the paper, we compare EPIC global spectral reflectances in 2021–2016. We found that there are four occasions when the scattering angle reaches about 178° and associated with them enhanced global daily average spectral reflectances in 2021. The scattering angle related reflectance enhancements are not found in 2016 data when the maximum scattering angle is about 174.5°. CERES data do not show such occasions in global daily reflected shortwave flux. As a result, those enhanced reflectance occasions are primarily due to the change in scattering angle. The enhancement due to changes in scattering angle depends strongly on wavelength, primarily because of wavelength dependence of cloud scattering phase function. Radiative transfer calculations show that the change in scattering angles has the largest impact on reflectance in the red and NIR channels at 680 nm and 780 nm and the smallest influence on reflectance in the UV channel at 388 nm, consistent with EPIC observations. The change of global average cloud amount also plays an important role in the reflectance enhancement. The influence of the cloud effect depends on whether the change is in phase or not with the change of scattering angle.

DSCOVR EPIC↗

A new approach to resonance line scattering in planetary atmospheres

The invariant imbedding technique is applied to the problem of resonance line scattering with frequency redistribution. By applying the principles of invariance to the resonance line scattering problem a set of non-linear, integrodifferential equations for the scattering and transmission functions are derived. Thus, an alternate approach to the resonance line scattering problem is presented. Rather than solving for the specific intensity directly the invariant imbedding equations may be solved for the scattering and transmission functions from which the specific intensity may be calculated. The technique is very general and in principle, can accommodate scattering in inhomogeneous atmospheres with arbitrary frequency redistribution and scattering phase functions. Solutions to the invariant imbedding equations in some simple cases are presented. If the scattering is isotropic and completely noncoherent and the atmosphere may be modeled as homogeneous, the scattering and transmission functions may be expressed in terms of generalized H, X and Y functions. This technique is extended to the problems of coupled spectral lines and scattering of radiation from internal sources.

Yelle, Roger V.↗

Systematic study of the surface properties of the nuclear potential with high precision large-angle quasi-elastic scatterings

High precision excitation functions of large-angle quasi-elastic scattering for the systems of {sup 16}O+{sup 208}Pb, {sup 196}Pt, {sup 184}W, and {sup 154,152}Sm at energies well below the Coulomb barrier were measured. The surface diffuseness parameters of the real part of the Woods-Saxon potential have been extracted from the single-channel and coupled-channels calculations, respectively. By considering the effect of couplings, the extracted diffuseness parameters are in the range from 0.64 to 0.69 fm, which is close to the values extracted from the systematic analyses of elastic and inelastic scattering data. On the other hand, single-channel calculations give somewhat larger values in the range from 0.68 to 0.77 fm, especially for systems with deformed target nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculation of the Scattering Amplitude Without Partial Wave Expansion

Two developments in the direct calculation of the angular differential scattering amplitude have been implemented: (a) The integral expansion of the scattering amplitude is simplified by analytically integration over the azimuthal angle. (b) The resulting integral as a function of scattering angle is calculated by using the numerically generated wave function from a finite element method calculation. Results for electron-hydrogen scattering in the static approximation will be shown to be as accurate as a partial wave expansion with as many l's as is necessary for convergence at the incident energy being calculated.

Shertzer, J.↗