MRI Load Profile Characterization Across Scanner Manufacturers and Field Strengths - Opportunities for Energy Efficiency Improvements

Radiology plays a vital role in patient care, but a reliance on energy-intensive imaging equipment leads to significant greenhouse gas emissions. MRI scanners can consume up to 80% of their total energy during times when there is not active patient imaging. Characterizing MRI average power and time to enter low-power mode across scanning protocols can identify energy efficiency opportunities.

emissions↗

Development of combined microstructure and structure characterization facility for in situ and operando studies at the Advanced Photon Source

Following many years of evolutionary development, first at the National Synchrotron Light Source, Brookhaven National Laboratory, and then at the Advanced Photon Source (APS), Argonne National Laboratory, the APS ultra-small-angle X-ray scattering (USAXS) facility has been transformed by several new developments. These comprise a conversion to higher-order crystal optics and higher X-ray energies as the standard operating mode, rapid fly scan measurements also as a standard operational mode, automated contiguous pinhole small-angle X-ray scattering (SAXS) measurements at intermediate scattering vectors, and associated rapid wide-angle X-ray scattering (WAXS) measurements for X-ray diffraction without disturbing the sample geometry. With each mode using the USAXS incident beam optics upstream of the sample, USAXS/SAXS/WAXS measurements can now be made within 5 min, allowing in situ and operando measurement capabilities with great flexibility under a wide range of sample conditions. Furthermore, these developments are described, together with examples of their application to investigate materials phenomena of technological importance. Developments of two novel USAXS applications, USAXS-based X-ray photon correlation spectroscopy and USAXS imaging, are also briefly reviewed.

47 OTHER INSTRUMENTATION↗

Nonlinear gyrokinetic simulations of the I-mode high confinement regime and comparisons with experiment

For the first time, nonlinear gyrokinetic simulations of I-mode plasmas are performed and compared with experiment. I-mode is a high confinement regime, featuring energy confinement similar to H-mode, but without enhanced particle and impurity particle confinement [D. G. Whyte et al., Nucl. Fusion 50, 105005 (2010)]. As a consequence of the separation between heat and particle transport, I-mode exhibits several favorable characteristics compared to H-mode. The nonlinear gyrokinetic code GYRO [J. Candy and R. E. Waltz, J Comput. Phys. 186, 545 (2003)] is used to explore the effects of E × B shear and profile stiffness in I-mode and compare with L-mode. The nonlinear GYRO simulations show that I-mode core ion temperature and electron temperature profiles are more stiff than L-mode core plasmas. Scans of the input E × B shear in GYRO simulations show that E × B shearing of turbulence is a stronger effect in the core of I-mode than L-mode. The nonlinear simulations match the observed reductions in long wavelength density fluctuation levels across the L-I transition but underestimate the reduction of long wavelength electron temperature fluctuation levels. The comparisons between experiment and gyrokinetic simulations for I-mode suggest that increased E × B shearing of turbulence combined with increased profile stiffness are responsible for the reductions in core turbulence observed in the experiment, and that I-mode resembles H-mode plasmas more than L-mode plasmas with regards to marginal stability and temperature profile stiffness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of mesoscopic turbulent transport events with long-radial-range correlation in DIII-D H-mode plasmas

A dimensionless collisionality scan has been performed in H-mode plasmas on DIII-D tokamak, with detailed measurements of intermediate-to-high wavenumber turbulence using Doppler backscattering systems. Furthermore, it is found that the shorter wavelength turbulence develops into spatially asymmetric turbulent structures with a long-radial-range correlation (LRRC) in the mid-radius region of high collisionality discharges. Linear cgyro simulations indicate that the underlying turbulence is likely driven by the electron-temperature-gradient mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synergy of coupled kink and tearing modes in fast ion transport

One aspect of the interaction between fast ions and magnetohydrodynamic (MHD) instabilities is the fast ion transport. Coupled kink and tearing MHD instabilities have also been reported to cause fast ion transport. Recently, the 'kick' model has been developed to compute the evolution of the fast ion distribution from neutral beam injection using instabilities as phase-space resonance sources. Overall, the goal of this paper is to utilize the kick model to understand the physics of fast ion transport caused by the coupled kink and tearing modes. Soft x-ray diagnostics are used to identify the mode parameters in the National Spherical Torus Experiment. The comparison of neutron rates measured and computed from time-dependent TRANSP simulation with the kick model shows that the coupling of kink and tearing mode is important in determination of the fast ion transport. The numerical scan of the mode parameters shows that the relative phase of the kink and tearing modes and the overlapping of kink and tearing mode resonances in the phase space can affect the fast ion transport, suggesting that the synergy of the coupled modes may be causing the fast ion transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synergy of Coupled Kink and Tearing Modes in Fast Ion Transport

One aspect of the interaction between fast ions and magnetohydrodynamic (MHD) instabilities is the fast ion transport. Coupled kink and tearing MHD instabilities have also been reported to cause fast ion transport. Recently, the ''kick" model has been developed to compute the evolution of the fast ion distribution from the neutral beam injection using instabilities as phase space resonance sources. The goal of this paper is to utilize the kick model to understand the physics of fast ion transport caused by the coupled kink and tearing modes. Soft X-ray diagnostics are used to identify the mode parameters in NSTX. The comparison of neutron rates measured and computed from time-dependent TRANSP simulation with the kick model shows the coupling of kink and tearing mode is important in determination of the fast ion transport. The numerical scan of the mode parameters shows that the relative phase of the kink and tearing modes and the overlapping of kink and tearing mode resonances in the phase space can affect the fast ion transport, suggesting that the synergy of the coupled modes may be causing the fast ion transpor

Energetic Particles↗

Image processing via ultrasonics - Status and promise

Acousto-electric devices for electronic imaging of light are discussed. These devices are more versatile than line scan imaging devices in current use. They have the capability of presenting the image information in a variety of modes. The image can be read out in the conventional line scan mode. It can be read out in the form of the Fourier, Hadamard, or other transform. One can take the transform along one direction of the image and line scan in the other direction, or perform other combinations of image processing functions. This is accomplished by applying the appropriate electrical input signals to the device. Since the electrical output signal of these devices can be detected in a synchronous mode, substantial noise reduction is possible

Kornreich, P. G.↗

Characterization and Application of a Hybrid Optical Microscopy/Laser Ablation Liquid Vortex Capture/Electrospray Ionization System for Mass Spectrometry Imaging with Sub-micrometer Spatial Resolution

Herein, a commercial optical microscope, laser microdissection instrument was coupled with an electrospray ionization mass spectrometer via a low profile liquid vortex capture probe to yield a hybrid optical microscopy/mass spectrometry imaging system. The instrument has bright-field and fluorescence microscopy capabilities in addition to a highly focused UV laser beam that is utilized for laser ablation of samples. With this system, material laser ablated from a sample using the microscope was caught by a liquid vortex capture probe and transported in solution for analysis by electrospray ionization mass spectrometry. Both lane scanning and spot sampling mass spectral imaging modes were used. The smallest area the system was able to ablate was ~0.544 μm × ~0.544 μm, achieved by oversampling of the smallest laser ablation spot size that could be obtained (~1.9 μm). With use of a model photoresist surface, known features as small as ~1.5 μm were resolved. The capabilities of the system with real world samples were demonstrated first with a blended polymer thin film containing poly(2-vinylpyridine) and poly(N-vinylcarbazole). Using spot sampling imaging, sub-micrometer sized features (0.62, 0.86, and 0.98 μm) visible by optical microscopy were clearly distinguished in the mass spectral images. A second real world example showed the imaging of trace amounts of cocaine in mouse brain thin tissue sections. Lastly, with use of a lane scanning mode with ~6 μm × ~6 μm data pixels, features in the tissue as small as 15 μm in size could be distinguished in both the mass spectral and optical images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging Single Atoms Using Secondary Electrons with an Aberration-Corrected Electron Microscope

Aberration correction has embarked on a new frontier in electron microscopy by overcoming the limitations of conventional round lenses, providing sub-angstrom-sized probes. However, improvement of spatial resolution using aberration correction so far has been limited to the use of transmitted electrons both in scanning and stationary mode, with an improvement of 20-40%. In contrast, advances in the spatial resolution of scanning electron microscopes (SEMs), which are by far the most widely used instrument for surface imaging at the micrometre-nanometre scale, have been stagnant, despite several recent efforts. Here, we report a new SEM, with aberration correction, able to image single atoms by detecting electrons emerging from its surface as a result of interaction with the small probe. The spatial resolution achieved represents a fourfold improvement over the best-reported resolution in any SEM. Furthermore, we can simultaneously probe the sample through its entire thickness with transmitted electrons. This ability is significant because it permits the selective visualization of bulk atoms and surface ones, beyond a traditional two-dimensional projection in transmission electron microscopy. It has the potential to revolutionize the field of microscopy and imaging, thereby opening the door to a wide range of applications, especially when combined with simultaneous nanoprobe spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal Control for X-Ray Mircroscopes

In this article, a systematic framework for designing the control for fine positioning (scanning) stages of X-ray microscopes is presented. This framework facilitates designs that simultaneously achieve specifications on positioning resolution and tracking bandwidth while guaranteeing robustness of the closed loop device to unmodeled uncertainties. We use robust optimal control techniques for modeling, quantifying design objectives and system-specific challenges, and designing the control laws. The control designs were implemented on a three degree of freedom piezoactuated flexure stages dedicated for fine positioning of X-ray optics. Experimental results demonstrate significant improvements in positioning performance of 134%, 150%, and 132% in tracking bandwidths along the lateral (X), vertical (Y), and beam (Z) directions, respectively, when compared to proportional-integral-derivative controller designs. This was achieved while keeping similar or better positioning resolution and robustness measures. Fast scanning for X-ray imaging was demonstrated in both the step scan and flyscan modes, where bandwidth was improved by over 450 times with flyscan compared to the step scan.

42 ENGINEERING↗

SU-F-J-166: Volumetric Spatial Distortions Comparison for 1.5 Tesla Versus 3 Tesla MRI for Gamma Knife Radiosurgery Scans Using Frame Marker Fusion and Co-Registration Modes

Purpose: To compare typical volumetric spatial distortions for 1.5 Tesla versus 3 Tesla MRI Gamma Knife radiosurgery scans in the frame marker fusion and co-registration frame-less modes. Methods: Quasar phantom by Modus Medical Devices Inc. with GRID image distortion software was used for measurements of volumetric distortions. 3D volumetric T1 weighted scans of the phantom were produced on 1.5 T Avanto and 3 T Skyra MRI Siemens scanners. The analysis was done two ways: for scans with localizer markers from the Leksell frame and relatively to the phantom only (simulated co-registration technique). The phantom grid contained a total of 2002 vertices or control points that were used in the assessment of volumetric geometric distortion for all scans. Results: Volumetric mean absolute spatial deviations relatively to the frame localizer markers for 1.5 and 3 Tesla machine were: 1.39 ± 0.15 and 1.63 ± 0.28 mm with max errors of 1.86 and 2.65 mm correspondingly. Mean 2D errors from the Gamma Plan were 0.3 and 1.0 mm. For simulated co-registration technique the volumetric mean absolute spatial deviations relatively to the phantom for 1.5 and 3 Tesla machine were: 0.36 ± 0.08 and 0.62 ± 0.13 mm with max errors of 0.57 and 1.22 mm correspondingly. Conclusion: Volumetric spatial distortions are lower for 1.5 Tesla versus 3 Tesla MRI machines localized with markers on frames and significantly lower for co-registration techniques with no frame localization. The results show the advantage of using co-registration technique for minimizing MRI volumetric spatial distortions which can be especially important for steep dose gradient fields typically used in Gamma Knife radiosurgery. Consultant for Elekta AB.

60 APPLIED LIFE SCIENCES↗

MSAT vehicular antennas with self scanning array elements

A new approach for designing low profile antennas for MSAT applications is presented. It is based on stacking two microstrip antennas that operate at two adjacent modes. The beam scanning is achieved by introducing a phase shift between the stacked elements and consequently a low cost self scan array element is developed. The concept is used to investigate two different antenna types: (1) a single element unit, with its phase shifter, that provides a moderate gain of about 7 dBic; and (2) a seven element array with a peak gain of about 14 dBic. Computed and measured data for each design are presented and discussed.

Shafai, L.↗

Effect of Irradiation Mode on Irradiated Microstructure of HT9

Core components in Generation IV fast reactors are expected to be exposed to very high damage levels of 200 displacements per atom (dpa) and above. Numerous issues with in-reactor irradiations including residual radioactivity, expense, length of irradiation and availability have led to increased interest in ion irradiation as a surrogate. Self-ion irradiations can produce damage rates of around 10{sup -3} dpa/s with well-controlled temperature, doses and dose rates, allowing for accelerated irradiation testing. Along with these benefits, ion irradiations have been shown to reproduce many of the same irradiation-induced features as in reactor irradiations. Of particular interest at high doses is formation of voids, precipitates and evolution of the dislocation microstructure. However, the beam mode under ion irradiation must be addressed. Raster scanning has been shown to produce microstructural features similar to those observed in-reactor irradiations, however, since they are a pulsed type irradiation, they may induce artifacts as a result of annealing between pulses. Defocused beams have the benefit of full coverage 100% of the time, but may be challenging in terms of ensuring even irradiation over a large area as well as in reaching high enough currents to maintain acceptable damage rates to be useful as a surrogate. This paper reports upon the comparison of behavior of ferritic martensitic steels under a raster scanned or defocused beam mode. The objective is to determine the effect of beam condition the irradiated microstructural; specifically, on the formation of voids, precipitates and dislocation loops and analyze these results within the context of the FDRT model. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synthetic aperture microwave imaging with active probing for fusion plasma diagnostics

A Synthetic Aperture Microwave Imaging (SAMI) system has been designed and built to obtain 2-D images at several frequencies from fusion plasmas. SAMI uses a phased array of linearly polarised antennas. The array configuration has been optimised to achieve maximum synthetic aperture beam efficiency. The signals received by antennas are down-converted to the intermediate frequency range and then recorded in a full vector form. Full vector signals allow beam focusing and image reconstruction in both real time and a post-processing mode. SAMI can scan over 16 pre-programmed frequencies in the range of 10-35GHz with a switching time of 300ns. The system operates in 2 different modes simultaneously: both a 'passive' imaging of plasma emission and also an 'active' imaging of the back-scattered signal of the radiation launched by one of the antennas from the same array. This second mode is similar to so-called Doppler backscattering (DBS) reflectometry with 2-D resolution of the propagation velocity of turbulent structures. Both modes of operation show good performance in fusion plasma experiments on Mega Amp Spherical Tokamak (MAST). We have obtained the first ever 2-D images of BXO mode conversion windows. With active probing, first ever turbulence velocity maps have been obtained. We present an overview of the diagnostic and discuss recent results. In contrast to quasi-optical microwave imaging systems SAMI requires neither big aperture viewing ports nor large 2-D detector arrays to achieve the desired imaging resolution. The number of effective 'pixels' of the synthesized image is proportional to the number of receiving antennas squared. Thus only a small number of optimised antennas is sufficient for the majority of applications. Possible implementation of SAMI on ITERand DEMO is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuning and scanning control system for high resolution alexandrite lasers

An alexandrite laser is spectrally narrowed and tuned by the use of three optical elements. Each element provides a successively higher degree of spectral resolution. The digitally controlled tuning and scanning control servo system simultaneously positions all three optical elements to provide continuous high resolution laser spectral tuning. The user may select manual, single, or continuous modes of automated scanning of ranges up to 3.00/cm and at scan rates up to 3.85/cm/min. Scanning over an extended range of up to 9.999/cm may be achieved if the highest resolution optic is removed from the system. The control system is also capable of being remotely operated by another computer or controller via standard RS-232 serial data link.

Smith, James C.↗

In-flight identification of the Galileo spacecraft flexible mode characteristics

The Galileo scan platform is controlled in two degrees of freedom. A clock (Spin Bearing) actuator controls the relative position between the rotor and stator, and a cone actuator controls the position between the stator and the platform. Instruments on the platform are required to point to 140 micro-rad accuracy and 50 micro-rad per second stability. The system identification objectives were to identify dominant structural resonance frequencies, mode shapes, and damping ratio which exist in the transfer function between the clock actuator and the gyro sensor; and position the notch filter to limit undesirable actuator torque output to ensure stability and performance.

Wong, Edward C.↗