Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Attenuation-based size metric for estimating organ dose to patients undergoing tube current modulated CT exams

Purpose: Task Group 204 introduced effective diameter (ED) as the patient size metric used to correlate size-specific-dose-estimates. However, this size metric fails to account for patient attenuation properties and has been suggested to be replaced by an attenuation-based size metric, water equivalent diameter (D{sub W}). The purpose of this study is to investigate different size metrics, effective diameter, and water equivalent diameter, in combination with regional descriptions of scanner output to establish the most appropriate size metric to be used as a predictor for organ dose in tube current modulated CT exams. Methods: 101 thoracic and 82 abdomen/pelvis scans from clinically indicated CT exams were collected retrospectively from a multidetector row CT (Sensation 64, Siemens Healthcare) with Institutional Review Board approval to generate voxelized patient models. Fully irradiated organs (lung and breasts in thoracic scans and liver, kidneys, and spleen in abdominal scans) were segmented and used as tally regions in Monte Carlo simulations for reporting organ dose. Along with image data, raw projection data were collected to obtain tube current information for simulating tube current modulation scans using Monte Carlo methods. Additionally, previously described patient size metrics [ED, D{sub W}, and approximated water equivalent diameter (D{sub Wa})] were calculated for each patient and reported in three different ways: a single value averaged over the entire scan, a single value averaged over the region of interest, and a single value from a location in the middle of the scan volume. Organ doses were normalized by an appropriate mAs weighted CTDI{sub vol} to reflect regional variation of tube current. Linear regression analysis was used to evaluate the correlations between normalized organ doses and each size metric. Results: For the abdominal organs, the correlations between normalized organ dose and size metric were overall slightly higher for all three differently (global, regional, and middle slice) reported D{sub W} and D{sub Wa} than they were for ED, but the differences were not statistically significant. However, for lung dose, computed correlations using water equivalent diameter calculated in the middle of the image data (D{sub W,middle}) and averaged over the low attenuating region of lung (D{sub W,regional}) were statistically significantly higher than correlations of normalized lung dose with ED. Conclusions: To conclude, effective diameter and water equivalent diameter are very similar in abdominal regions; however, their difference becomes noticeable in lungs. Water equivalent diameter, specifically reported as a regional average and middle of scan volume, was shown to be better predictors of lung dose. Therefore, an attenuation-based size metric (water equivalent diameter) is recommended because it is more robust across different anatomic regions. Additionally, it was observed that the regional size metric reported as a single value averaged over a region of interest and the size metric calculated from a single slice/image chosen from the middle of the scan volume are highly correlated for these specific patient models and scan types.

60 APPLIED LIFE SCIENCES↗

Atom Identification in Bilayer Moiré Materials with Gomb-Net

Moiré patterns in van der Waals bilayer materials complicate the analysis of atomic-resolution images, hindering the atomic-scale insight typically attainable with scanning transmission electron microscopy. Here, we report a method to detect the positions and identities of atoms in each of the individual layers that compose twisted bilayer heterostructures. We developed a deep learning model, Gomb-Net, which identifies the coordinates and atomic species in each layer, deconvoluting the moiré pattern. This enables layer-specific mapping of atomic positions and dopant distributions, unlike other commonly used segmentation models which struggle with moiré-induced complexity. Using this approach, we explored the Se atom substitutional site distribution in a twisted fractional Janus WS 2 -WS 2(1–x) Se 2x heterostructure and found that layer-specific implantation sites are unaffected by the moiré pattern’s local energetic or electronic modulation. In conclusion, this advancement enables atom identification within material regimes where it was not possible before, opening new insights into previously inaccessible material physics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ODS Characterization Progress Report 06/27/08

This progress report is intended to help keep track of the work that has been performed in characterizing ODS steels for the LIFE project. This specific report details the current status of the characterization of a 24% Cr, 1% Y{sub 2}O{sub 3} ODS steel obtained from Wayne King via Geoff Campbell. Since no pedigree of the material could be obtained, a baseline characterization was necessary prior to studying processing, welding, and corrosion behavior. This document details the results obtained from analysis performed using scanning electron microscopy (SEM), electron backscatter diffraction (EBSD) and energy dispersive spectroscopy (EDS). At the time of writing, transmission electron microscopy (TEM) and microhardness measurements have not been completed, and will be included in a future report. The results are presented in two sections: microstructure, and phase identification. As the names suggest, the first section will report on the microstructure in the general sense and include details such as grain size and texture, and the second section will include the identification of the phases present in the baseline material.

42 ENGINEERING↗

How Grain Boundaries in Cu(In,Ga)Se2 Thin Films are Charged: Revisit

Potential measurements on Cu(In,Ga)Se{sub 2} thin films using scanning Kelvin probe force microscopy have been reported extensively to address grain-boundary (GB) recombination by examining GB charging. However, the results are highly inconsistent. We revisit this issue by measuring high- and low-quality wide-bandgap films and using a complementary method of scanning capacitance microscopy. Our results show consistent positively charged GBs in our high-quality films with minimal surface defects, except for the {Sigma}3[112] GBs, which are charge neutral. We discuss possible artifacts due to surface defects when examining the GB charging and the role of GBs in the device performance.

14 SOLAR ENERGY↗

Direction-Controlled Light-Driven Movement of Microribbons

Novel direction-controlled movements of microribbons self-assembled from perylene diimide molecules are reported on various hydrophobic surfaces under scanning laser irradiation. A “dynamic exciton charge model” is developed to elucidate the underlying mechanism. The findings provide an innovative strategy for the design of microscale systems capable of continuous and directional movement driven by light.

36 MATERIALS SCIENCE↗

Atomic mass compilation 2012

Atomic mass reflects the total binding energy of all nucleons in an atomic nucleus. Compilations and evaluations of atomic masses and derived quantities, such as neutron or proton separation energies, are indispensable tools for research and applications. In the last decade, the field has evolved rapidly after the advent of new production and measuring techniques for stable and unstable nuclei resulting in substantial ameliorations concerning the body of data and their precision. Here, we present a compilation of atomic masses comprising the data from the evaluation of 2003 as well as the results of new measurements performed. The relevant literature in refereed journals and reports as far as available, was scanned for the period beginning 2003 up to and including April 2012. Overall, 5750 new data points have been collected. Recommended values for the relative atomic masses have been derived and a comparison with the 2003 Atomic Mass Evaluation has been performed. This work has been carried out in collaboration with and as a contribution to the European Nuclear Structure and Decay Data Network of Evaluations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sequences in Linker-1 domain of the multidrug resistance associated protein (MRP1 or ABCC1) bind to tubulin and their binding is modulated by phosphorylation

The multidrug resistant associated protein 1 (or MRP1, ABCC1) encodes two cytoplasmic linker domains (L0 and L1) composed of highly charged sequences with multiple protein kinase A/C phosphorylation sites. In this report we made use of the scanning peptide approach to identify MRP1 linker L1 (L1{sup MRP1}) interacting proteins. Scanning heptapeptides covering L1{sup MRP1} 126 amino acids (Ile{sup 846}- Leu{sup 972}) were synthesized and used in pull-down assays to isolate proteins from cell extracts (human multidrug resistant SCLC cell line; H69/AR). The results show four high affinity binding sequences in L1{sup MRP1} domain [{sup 866}FLRTYAST{sup 867}; {sup 906}SAGKQLQRQLSSS{sup 912}; {sup 925}ISRHHNSTA{sup 927} and {sup 954}AQTGQVKLSVYW{sup 959}] that bound ∼55 kDa and 110 kDa polypeptides. The latter polypeptides were identified by mass spectrometry as α- and β-tubulin monomers and dimers. Western blotting with monoclonal antibodies to α- and β-tubulin proteins confirmed the mass-spectrometry results. Moreover, using recombinant full-length GST-Linker 1 fusion polypeptide (GST-L1{sup MRP1}), we confirmed the peptide scanning approach demonstrating specific binding of tubulin to GST-L1{sup MRP1}. Intriguingly, substitutions of serine residues in L1{sup MRP1} by aspartic acid, but not alanine, abolished its binding to tubulin, suggesting that phosphorylation of Ser{sup 871,} {sup 915,} {sup 930,} {sup and} {sup 961} within L1{sup MRP1} may modulate its binding to tubulin. Taken together, the results of this study suggest possible interaction between MRP1 and tubulin that is modulated by phosphorylation of specific sequences in the L1{sup MRP1} domain. - Highlights: • This study shows direct binding between MRP1 Linker 1 (L1{sup MRP1}) domain and α- and β-tubulin subunits, using a scanning peptide approach. • Four short and dispersed sequences in L1{sup MRP1} domain interact with α/β-tubulin subunits. • Each sequence in L1{sup MRP1}-tubulin binding domain contains predicted protein kinase C/A site. • Substituting 3 of 4 serine with aspartic acid, but not alanine, in L1{sup MRP1} binding domains inhibit their binding to tubulin subunits.

60 APPLIED LIFE SCIENCES↗

Three-Dimensional Mapping of Resistivity and Microstructure of Composite Electrodes for Lithium-Ion Batteries

Nanoparticle silicon–graphite composite electrodes are a viable way to advance the cycle life and energy density of lithium-ion batteries. However, characterization of composite electrode architectures is complicated by the heterogeneous mixture of electrode components and nanoscale diameter of particles, which falls beneath the lateral and depth resolution of most laboratory-based instruments. In this work, we report an original laboratory-based scanning probe microscopy approach to investigate composite electrode microstructures with nanometer-scale resolution via contrast in the electronic properties of electrode components. Applying this technique to silicon-based composite anodes demonstrates that graphite, SiOx nanoparticles, carbon black, and LiPAA binder are all readily distinguished by their intrinsic electronic properties, with measured electronic resistivity closely matching their known material properties. Resolution is demonstrated by identification of individual nanoparticles as small as ~20 nm. Our technique presents future utility in multiscale characterization to better understand particle dispersion, localized lithiation, and degradation processes in composite electrodes for lithium-ion batteries.

25 ENERGY STORAGE↗

Correlating dynamic strain and photoluminescence of solid-state defects with stroboscopic x-ray diffraction microscopy

Abstract Control of local lattice perturbations near optically-active defects in semiconductors is a key step to harnessing the potential of solid-state qubits for quantum information science and nanoscale sensing. We report the development of a stroboscopic scanning X-ray diffraction microscopy approach for real-space imaging of dynamic strain used in correlation with microscopic photoluminescence measurements. We demonstrate this technique in 4H-SiC, which hosts long-lifetime room temperature vacancy spin defects. Using nano-focused X-ray photon pulses synchronized to a surface acoustic wave launcher, we achieve an effective time resolution of ~100 ps at a 25 nm spatial resolution to map micro-radian dynamic lattice curvatures. The acoustically induced lattice distortions near an engineered scattering structure are correlated with enhanced photoluminescence responses of optically-active SiC quantum defects driven by local piezoelectric effects. These results demonstrate a unique route for directly imaging local strain in nanomechanical structures and quantifying dynamic structure-function relationships in materials under realistic operating conditions.

36 MATERIALS SCIENCE↗

Exchange-biased topological transverse thermoelectric effects in a Kagome ferrimagnet

Abstract Kagome metal TbMn 6 Sn 6 was recently discovered to be a ferrimagnetic topological Dirac material by scanning tunneling microscopy/spectroscopy measurements. Here, we report the observation of large anomalous Nernst effect and anomalous thermal Hall effect in this compound. The anomalous transverse transport is consistent with the Berry curvature contribution from the massive Dirac gaps in the 3D momentum space as demonstrated by our first-principles calculations. Furthermore, the transverse thermoelectric transport exhibits asymmetry with respect to the applied magnetic field, i.e., an exchange-bias behavior. Together, these features place TbMn 6 Sn 6 as a promising system for the outstanding thermoelectric performance based on anomalous Nernst effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analytical and Dielectric Studies of the Ferroelectric Ba{sub 5}Ti{sub 2}O{sub 7}Cl{sub 4}

The thermo analytic analyses are necessary for general characterization of the materials, i.e. to know if any important changes are occurring in the material. The important changes are basically of two types: 1) changes occurring as a result of chemical reaction, and 2) hanges occurring as a result of some physical change, e.g. change of crystal structure, change of some atomic groups within the given crystal structure, some physical change involving mission or absorption of thermal energy, as for example, change of electron structure or electronic interactions. The changes involving chemical reactions usually involve variation in mass content of the material system, and these changes are studied by thermo gravimetric analysis (TGA). The changes of the second type are studied by differential thermal analysis (DTA) and/or by differential scanning calorimetry (DSC). The present work reports the studies of DTA and DSC, while TGA studies showed no significant changes.

36 MATERIALS SCIENCE↗

Watching bismuth nanowires grow

We report real-time high temperature scanning electron microscopy observations of the growth of bismuth nanowires via the on-film formation of nanowires (OFF-ON) method. These observations provide experimental evidence that thermally induced-stress on a Bi film is the driving force for the growth of Bi nanowires with high aspect ratios, uniform diameter, and high-quality crystallinity. Our results show that immobile grain boundaries in the Bi film are required for the growth of nanowires so that grain broadening resulting in hillock formation can be prevented. This study not only provides an understanding of the underlying mechanism, but also affords a strategy for facilitating nanowire growth by OFF-ON.

36 MATERIALS SCIENCE↗

Laser ablation of polymer coatings allows for electromagnetic field enhancement mapping around nanostructures

Subdiffraction spatially resolved, quantitative mapping of strongly localized field intensity enhancement on gold nanostructures via laser ablation of polymer thin films is reported. Illumination using a femtosecond laser scanning microscope excites surface plasmons in the nanostructures. The accompanying field enhancement substantially lowers the ablation threshold of the polymer film and thus creates local ablation spots and corresponding topographic modifications of the polymer film. Such modifications are quantified straightforwardly via scanning electron microscopy and atomic force microscopy. Thickness variation in the polymer film enables the investigation of either the initial ablation phase or ablation induced by collective enhancement effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanomanipulation and nanofabrication with multi-probe STM: From individual atoms to nanowires

The wide variety of nanoscale structures and devices demands novel tools for handling, assembly, and fabrication at nanoscopic positioning precision. The manipulation tools should allow for in situ characterization and testing of fundamental building blocks, such as nanotubes and nanowires, as they are built into functional devices. In this paper, a bottom-up technique for nanomanipulation and nanofabrication is reported by using a 4-probe scanning tunneling microscope (STM) combined with a scanning electron microscope (SEM). The applications of this technique are demonstrated in a variety of nanosystems, from manipulating individual atoms to bending, cutting, breaking carbon nanofibers, and constructing nanodevices for electrical characterizations. The combination of the wide field of view of SEM, the atomic position resolution of STM, and the flexibility of multiple scanning probes is expected to be a valuable tool for rapid prototyping in the nanoscience and nanotechnology.

Qin, Shengyong↗

Rare-earth high entropy alloys with hexagonal close-packed structure

The formation of octonary DyErGdHoLuScTbY and senary DyGdHoLaTbY and ErGdHoLaTbY high-entropy alloys (HEAs) with the hexagonal close-packed (HCP) structure was reported in this study. Experiments using scanning electron microscopy and x-ray diffraction confirmed the single HCP solid solution in the as-cast state for these three HEAs if the presence of minor rare-earth oxides due to contamination from processing is ignored. The measured compressive yield stress values for these HEAs at room temperature are 245, 205, and 360 MPa for the ErGdHoLaTbY, DyGdHoLaTbY, and DyErGdHoLuScTbY HEAs, respectively. As a result, the corresponding solid solution strengthening contributions for these HEAs were estimated using a simple elastic model, and the resulting contributions were 28 MPa, 27 MPa, and 42 MPa for the three aforementioned HEAs.

36 MATERIALS SCIENCE↗

Absence of a bulk signature of a charge density wave in hard x-ray measurements of UTe 2

The long-sought pair density wave (PDW) is an exotic phase of matter in which charge density wave (CDW) order is intertwined with the amplitude or phase of coexisting, superconducting order. Originally predicted to exist in copper-oxides, circumstantial evidence for PDW order now exists in a variety of materials. Recently, scanning tunneling microscopy (STM) studies have reported evidence for a three-component CDW at the surface of the heavy-fermion superconductor, UTe 2 , persisting below its superconducting transition temperature [Aishwarya et al., Nature 618, 928933 (2023); Gu et al., Nature 618, 921927 (2023); LaFleur et al., Nat. Commun. 15, 4456 (2024)]. Here, in this study, we use hard x-ray diffraction measurements on crystals of UTe 2 at 𝑇 = 1.9 and 12 K to search for a bulk signature of this CDW. Using STM measurements as a constraint, we calculate the expected locations of CDW superlattice peaks and sweep a large volume of reciprocal space in search of a signature. We fail to find any evidence for a CDW near any of the expected superlattice positions in many Brillouin zones. We estimate an upper bound on the CDW lattice distortion of 𝑢 max ≲ 4×10 −3 Å. Our results suggest that the CDW observed in STM is either purely electronic, somehow lacking a signature in the lattice, or is restricted to the material surface.

Kengle, Caitlin S.↗

ScAlN etch mask for highly selective silicon etching

Here, this work reports the utilization of a recently developed film, ScAlN, as a silicon etch mask offering significant improvements in high etch selectivity to silicon. Utilization of ScAlN as a fluorine chemistry based deep reactive ion etch mask demonstrated etch selectivity at 23 550:1, four times better than AlN, 11 times better than Al 2 O 3 , and 148 times better than silicon dioxide with significantly less resputtering at high bias voltage than either Al 2 O 3 or AlN. Ellipsometry film thickness measurements show less than 0.3 nm/min mask erosion rates for ScAlN. Micromasking of resputtered Al for Al 2 O 3 , AlN, and ScAlN etch masks is also reported here, utilizing cross-sectional scanning electron microscope and confocal microscope roughness measurements. With lower etch bias, the reduced etch rate can be optimized to achieve a trench bottom surface roughness that is comparable to SiO 2 etch masks. Etch mask selectivity enabled by ScAlN is likely to make significant improvements in microelectromechanical systems, wafer level packaging, and plasma dicing of silicon.

36 MATERIALS SCIENCE↗

Clinical characterization of a proton beam continuous uniform scanning system with dose layer stacking

A proton beam delivery system on a gantry with continuous uniform scanning and dose layer stacking at the Midwest Proton Radiotherapy Institute has been commissioned and accepted for clinical use. This paper was motivated by a lack of guidance on the testing and characterization for clinical uniform scanning systems. As such, it describes how these tasks were performed with a uniform scanning beam delivery system. This paper reports the methods used and important dosimetric characteristics of radiation fields produced by the system. The commissioning data include the transverse and longitudinal dose distributions, penumbra, and absolute dose values. Using a 208 MeV cyclotron's proton beam, the system provides field sizes up to 20 and 30 cm in diameter for proton ranges in water up to 27 and 20 cm, respectively. The dose layer stacking method allows for the flexible construction of spread-out Bragg peaks with uniform modulation of up to 15 cm in water, at typical dose rates of 1-3 Gy/min. For measuring relative dose distributions, multielement ion chamber arrays, small-volume ion chambers, and radiographic films were employed. Measurements during the clinical commissioning of the system have shown that the lateral and longitudinal dose uniformity of 2.5% or better can be achieved for all clinically important field sizes and ranges. The measured transverse penumbra widths offer a slight improvement in comparison to those achieved with a double scattering beam spreading technique at the facility. Absolute dose measurements were done using calibrated ion chambers, thermoluminescent and alanine detectors. Dose intercomparisons conducted using various types of detectors traceable to a national standards laboratory indicate that the measured dosimetry data agree with each other within 5%.

43 PARTICLE ACCELERATORS↗