PtCo/MWCNTs Prepared by a Microwave‐assisted Polyol Method for Selective Cinnamaldehyde Hydrogenation

Abstract Using microwave irradiation, PtCo alloy nanoparticles were deposited within a few minutes on COOH‐functionalized MWCNT supports. The obtained catalysts were used for selective hydrogenation of cinnamaldehyde, a reaction whose products are widely used in various fields. In the selective cinnamaldehyde hydrogenation to cinnamyl alcohol, microwave‐prepared catalysts (generically, Pt x Co y ‐MW) outperformed a catalyst prepared by the conventional method (Pt 1 Co 2 ‐con). The highest selective hydrogenation to cinnamyl alcohol, 89%, was obtained using Pt 1 Co 2 ‐MW, while Pt 1 Co 2 ‐con showed a selectivity of 76%. Characterization results confirmed that the microwave prepared samples had a stronger interaction between Pt and Co than that in the Pt 1 Co 2 ‐con sample. The alloyed Co altered the electronic structure of Pt, leading to favorable adsorption of the C=O bond by the lone‐pair electrons of its oxygen atom. Moreover, the Pt 1 Co 2 ‐MW sample showed neglectable change in catalytic performance (e. g., cinnamaldehyde conversion and selective hydrogenation to cinnamyl alcohol) during recycling experiments.

Wang, Kaiying↗

Cell-Type-Specific Proteomics Analysis of a Small Number of Plant Cells by Integrating Laser Capture Microdissection with a Nanodroplet Sample Processing Platform

Plant organs and tissues contain multiple cell types, which are well organized in 3-dimensional structure to efficiently perform physiological functions such as homeostasis, response to environmental perturbation, pathogen infection. It is critically important to perform molecular measurements at the cell-type-specific level to discover mechanisms and unique features of cell populations that govern differentiation and respond to external perturbations. Although mass spectrometry-based proteomics has been demonstrated as an enabling discovery tool to study plant physiology, conventional approaches require millions of cells to generate robust biological conclusions. Such requirements mask the cell-to-cell heterogeneities and limit the comprehensive profiling of plant proteins at spatially resolved and cell-type-specific resolutions. This protocol describes a recently-developed proteomics workflow for studying a small number of plant cells by integrating laser capture microdissection, microfluidic nanodroplet-based sample preparation, with ultrasensitive liquid chromatography-mass spectrometry. Using poplar as a model tree species, we provide detailed protocols, including plant tissue harvest, tissue preparation, cryosectioning, laser microdissection, protein digestion, mass spectrometry measurement, and data analysis. We show the workflow enables the precise identification and quantification of thousands of proteins from hundreds of isolated plant root and leaf cells.

59 BASIC BIOLOGICAL SCIENCES↗

Simultaneous Determination of Halogens and Metals in Waste Plastic Pyrolysis Oil by Inductively Coupled Plasma Mass Spectrometry

A major barrier to integrating pyrolysis-derived oil into conventional refinery technology is the presence of impurities, particularly halogens and metals, that can deactivate catalysts. This study presents a novel, cost-effective approach for the simultaneous analysis of a subset of halogens, metals, nonmetals, and metalloids in complex, industrially relevant distilled pyrolysis oil samples, this was previously achievable only through multiple techniques. Excellent results were obtained using a widely accessible inductively coupled plasma mass spectrometry (ICP-MS) method with helium gas mode and standard laboratory consumables, enabling high-throughput analysis and efficient evaluation of adsorbent performance. Sample preparation is straightforward, requiring only dilution in a compatible matrix, and provides accurate and precise quantification, with 75%–137% spike recovery for Be, Ti, V, Cr, Fe, Ni, Co, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, and 62%–65% spike recovery for Cl and 109%–133% spike recovery for Br. Additionally, an enhanced version of the method using ICP-MS/MS and hydrogen gas is described, which has higher accuracy with 69%–112% spike recovery for Be, B, Ti, V, Fe, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, with 85%–102% spike recovery for Cl and 63%–93% spike recovery for Br. Helium mode detection limits for industrially relevant elements (V, Fe, Ni, Cu, As, and Pb) are less than 1.7 µg/kg, and less than 0.2 mg/kg for Br and Cl. Furthermore, this methodology facilitates rapid systematic evaluation of adsorption capacities of materials under time-on-stream conditions and supports robust comparisons across diverse operating environments.

Lazarcik, James [University of Wisconsin-Madison, ↗

The microbiologist's guide to metaproteomics

Metaproteomics is an emerging approach for studying microbiomes, offering the ability to characterize proteins that underpin microbial functionality within diverse ecosystems. As the primary catalytic and structural components of microbiomes, proteins provide unique insights into the active processes and ecological roles of microbial communities. By integrating metaproteomics with other omics disciplines, researchers can gain a comprehensive understanding of microbial ecology, interactions, and functional dynamics. This review, developed by the Metaproteomics Initiative (www.metaproteomics.org), serves as a practical guide for both microbiome and proteomics researchers, presenting key principles, state-of-the-art methodologies, and analytical workflows essential to metaproteomics. Topics covered include experimental design, sample preparation, mass spectrometry techniques, data analysis strategies, and statistical approaches.

bioinformatics↗

Extrusion‐Spheronization of Energetic Materials

The prevailing method to produce plastic‐bonded explosive (PBX) molding powder, or “prills”, is a complex, multiphase, and bespoke process that was developed by the high explosives (HEs) manufacturing industry several decades ago. This work demonstrates the utility of a simpler, widely‐used mechanical process—extrusion‐spheronization—to produce PBX prills. We begin by detailing precautions taken to enable safe remote operation of extrusion‐spheronization equipment with HE. We then perform a study investigating the effect of lacquer solvent composition on the particle packing, pressed density, and compressive strength properties of a 95 wt.% TATB/5 wt.% polymer binder formulation akin to PBX 9502. It was found that increased composition of low vapor pressure solvents caused prolonged retention of the solvent, resulting in tackier materials that would agglomerate and form larger prills. The larger prills also led to lower poured density and tapped density of HE prills and compressive strength of pressed PBX articles. The samples prepared with a 75% propyl acetate/25% butyl acetate lacquer solvent composition exhibited the highest compressive strength. However, it is believed that the prill packing and compressive strength properties are primarily driven by the prill size rather than the chemical composition of the lacquer itself. Extrusion‐spheronization remains a promising method to reliably and repeatably produce HE prills that is less sensitive to feedstock or process variation than traditional methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface analysis insight note: X‐ray photoelectron spectroscopy analysis of battery electrodes—Challenges with nickel–manganese–cobalt and Li examples using an Al Kα x‐ray source

X‐ray photoelectron spectroscopy (XPS) has become a highly important tool for the analysis of battery materials and components. However, both anecdotal and detailed analysis of selected parts of the literature indicate that many reports of XPS on battery electrodes have significant analysis or data flaws. In this paper, we highlight several of the common challenges that analysts face when using XPS for battery materials, pointing to recent literature that addresses many of the critical issues associated with sample preparation as well as data collection and analysis. A common error for battery materials (and other materials) involves ignoring peak overlaps and interferences. Specifically, when a “minor” peak associated with a component in relatively high concentration overlaps or contributes to the primary peak (or one recommended for quantitative analysis) from a different element in the material. Overlap issues apply to many battery electrodes composed of many elements with complex photoelectron peak structures, as well as those involving peaks with seemingly simpler spectral envelopes such as Li and F. Examples of issues associated with battery systems are highlighted by a discussion of challenges associated with XPS analysis of Li and nickel–manganese–cobalt (NMC) electrodes in battery systems. Lithium analysis has challenges associated with the preparation and an often‐unrecognized peak overlap with F. In our laboratory and in the literature, NMC electrodes are often examined and new XPS users do not always recognize interference of the Auger signal from F KLL (in or on the electrode) with Ni 2p photoelectron spectrum when generated with Al Kα X‐rays. The use of simulated spectra involving both F and NiO demonstrates the extent of F Auger contributions to the Ni 2p signal strength as a function of the F/Ni atom ratio in the material and suggests spectra information that can be used to identify how significant effects will be on the resultant spectra. Our analysis demonstrates that in many cases overlap issues are significant for real electrode materials.

25 ENERGY STORAGE↗

Exploring Charged Defects in Ferroelectrics by the Switching Spectroscopy Piezoresponse Force Microscopy

Monitoring the charged defect concentration at the nanoscale is of critical importance for both the fundamental science and applications of ferroelectrics. However, up-to-date, high-resolution study methods for the investigation of structural defects, such as transmission electron microscopy, X-ray tomography, etc., are expensive and demand complicated sample preparation. Here, with an example of the lanthanum-doped bismuth ferrite ceramics, a novel method is proposed based on the switching spectroscopy piezoresponse force microscopy (SSPFM) that allows probing the electric potential from buried subsurface charged defects in the ferroelectric materials with a nanometer-scale spatial resolution. When compared with the composition-sensitive methods, such as neutron diffraction, X-ray photoelectron spectroscopy, and local time-of-flight secondary ion mass spectrometry, the SSPFM sensitivity to the variation of the electric potential from the charged defects is shown to be equivalent to less than 0.3 at% of the defect concentration. Additionally, the possibility to locally evaluate dynamics of the polarization screening caused by the charged defects is demonstrated, which is of significant interest for further understanding defect-mediated processes in ferroelectrics.

42 ENGINEERING↗

Use of Longitudinal Serum Analysis and Machine Learning to Develop a Classifier for Cancer Early Detection

Early detection of solid tumors through a simple screening process, such as the proteomic analysis of biofluids, has the potential to significantly alter the management and outcomes of cancers. The application of advanced targeted proteomics measurements and data analysis strategies to uniformly collected serum or plasma samples would enable longitudinal studies of cancer risk, progression, and response to therapy that have the potential to significantly reduce cancer burden in general. In this article, we describe a generalizable workflow combining robust, multiplexed targeted proteomics measurements applied to longitudinal samples from the Department of Defense Serum Repository with a Random Forest machine learning method for developing and initially evaluating the performance of candidate biomarker panels for early detection of cancers. The effectiveness of this approach was demonstrated in a cohort of 175 head and neck squamous cell carcinoma patients. The outlined protocols include methods for sample preparation, instrument analysis, and data analysis and interpretation using this workflow.

Longitudinal analysis, machine learning, cancer, e↗

Surface engineering to enhance heat generation and joint strength in dissimilar materials AZ31 and DP590 ultrasonic welding

A multiscale simulation approach was developed and employed to optimize the sheet surface conditions for higher interfacial temperature and joint strength in ultrasonic welding of magnesium alloy AZ31 and dual-phase steel DP590. First, a mesoscale model was used to study the relationship between friction coefficient and surface roughness, which can be modified by various engineering methods. Then a macroscopic process model was employed to study the effects of surface roughness on heat generation, indicating that a temperature increase can be achieved with rougher surfaces on two sides of both DP590 and AZ31 sheets. Samples prepared by sanding and filing, as well as grinding, were first characterized for surface roughness and then welded under ultrasonic vibration. An infrared camera was used to measure temperatures in situ for model validation. Overall, lap shear test results for the welded joint showed that the joint strength can be improved by 10~25% using filing and round grinding methods as a result of the enhanced heat generation and mechanical interlocking on the interface.

42 ENGINEERING↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

Total Mercury Analysis of Radioactive Waste Containing Multiple Mercury Species

In this work, a direct mercury analyzer (DMA) was used to analyze total mercury in radioactive waste samples containing methylmercury and other forms of mercury including Hg o (elemental) together with inorganic ionic mercury species and complexes. These samples were also analyzed using Cold Vapor Atomic Absorption Spectroscopy (CVAAS) and/or Inductively Coupled Plasma Mass Spectroscopy (ICMS). Comparative statistical evaluation of the results from spike solutions/simulants, liquid radioactive waste samples, and interlaboratory performance test samples demonstrated that the various methods generated accurate and/or equivalent total mercury data and equivalent precision (2σ ± < 20%). Triplicate total mercury analysis of an exemplar radioactive waste resulted in an average value of 54.1 mg/L (as Hg) using CVAAS, 55.1 mg/L using ICPMS and 56.0 mg/L using DMA. A primary advantage of the DMA in a radioactive environment is avoiding multi-step, labor-intensive, time-consuming and waste-producing sample preparation protocols needed for CVAAS and ICPMS. DMA was determined to be the preferred method for measuring total mercury in the Savannah River National Laboratory (SRNL) radioanalytical laboratory based on analytical performance combined with ease of use in a radiological containment unit.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

High-Energy X-ray Tomographic Analysis of Precursor Metal Powders (Ti-6Al-4V) Used for Additive Manufacturing

We utilized high-energy x-ray tomography to characterize Ti-6Al-4V metal powders (both as-received and recycled) used in powder-bed additive manufacturing process. The image processing workflow was developed to process and analyze large amount of data objectively by computer program. The distribution of size and shape of the metal particles as well as defect (mainly porosity) inside the particles was analyzed with the statistical representation and resolution in micrometer. The result revealed that circular-shaped porosity with various sizes could be embedded in the powder particles. These porosities could potentially be transferred to the 3D printed part and critically affect the mechanical performance of the component. The present study shows the effectiveness of characterizing metal powders using x-ray imaging techniques where sufficient number of particles can be sampled within tens of minutes with a minimum sample preparation and high accuracy. Clear structural differences in the as-received and recycled powders were delineated that helps in determining the feasibility of using the recycled powders.

36 MATERIALS SCIENCE↗

Review: Recent advances of ToF-SIMS for environmental analysis and imaging

Background: Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface analysis technique, initially developed and applied in inorganic materials and semiconductors. In past decades, ToF-SIMS has attracted more attention in its analysis capabilities of organic materials, with increased applications in biology, medical, and health development. It has also become a versatile and effective tool in environmental analysis due to its high mass resolution, mass accuracy, and depth profiling. Results: In this review, we first give an overview of the principle of ToF-SIMS and follow with recent ToF-SIMS applications in exemplary environmental study cases, including atmospheric aerosol, soil, water, plant, and organic solvent analysis. Moreover, sample preparation techniques are summarized in relation to corresponding environmental applications. Specifically, we call attention to ToF-SIMS investigations showcasing studies in surface chemical compositions, images, and depth profile analysis. These findings emphasize the important role of interfacial chemistry in environmental processes and provide valuable insights into dynamic processes, such as chemical transformation, particle formation, plant biology, and microbial inspired biotechnology development. The mass spectral imaging results acquired by ToF-SIMS offer a deeper understanding of intermediate stages and transient phases for environmental specimens. Significance: In situ and operando imaging offer new possibilities in studying phenomena in real time with high spatial resolution. Furthermore, it is anticipated that more research groups will use ToF-SIMS in environmental research given recent advances in measurement capabilities and surging needs in chemical mapping of complex analytes and systems.

Aerosol↗

Near-infrared spectroscopy as a green analytical tool for sustainable biomass characterization for biofuels and bioproducts: An overview

Biomass, a widely used renewable energy source, requires characterization to optimize biofuel and bioproduct processes, customize feedstocks, and ensure economic and environmental sustainability. Conventional wet-chemistry methods for biomass analysis are slow, expensive, and require significant reagents and skilled personnel. In contrast, near-infrared (NIR) spectroscopy, a faster, cost-effective, and reagent-free green technology, enables non-destructive biomass analysis with minimal sample preparation. This study provides an overview of the fundamentals of NIR spectroscopy and explores its recent applications for analyzing various biomass properties important to the biofuel and bioproduct industry. The study also critically evaluates the challenges and opportunities of using NIR spectroscopy for biomass analysis. This review aims to guide future research for rapid and high throughput characterization of biomass in the biomass industry, supporting the United Nations’ sustainable development goal (SDG) 7: producing affordable and sustainable energy.

Biofuels↗

Mechanochemical synthesis of hydraulically reactive calcium silicate minerals via thermally-assisted mechanical grinding

This study explores a thermally assisted mechanochemical approach alternative to conventional cement synthesis as a potential to produce hydraulically reactive calcium silicate phases. Ball milling of mixed CaO/SiO 2 feedstocks at temperature ranges 100-300 °C increases the formation of the Ca-O-Si bonds and precursor reactivity. Spectroscopic analyses (FTIR, MAS-NMR, UV-Vis DRS) indicate increasing amorphization with milling temperature, attributed to improved mixing and thermally assisted diffusion. Upon hydration, all treated samples exhibit exothermic heat release, with the sample prepared at 300 °C showing the most pronounced reactivity. Thermal analysis reveals weight loss consistent with C-S-H formation, confirming cement-like behavior. In summary, moderate thermal input during milling promotes structural activation and enhances downstream hydraulic reactivity, providing a proof-of-concept for energy-reduced cement precursor processing.

Alite↗

Bending and shear improvements in 3D-printed core sandwich composites through modification of resin uptake in the skin/core interphase region

Fused deposition modeling (FDM) printed polymers are rarely used as a structural material due to anisotropic and low mechanical properties compared with conventional composites. In recent years, greater need has been expressed for recycling of materials, such as recyclable FDM, at the end of service life to reduce environmental pollution and manufacture cost. However, how the amount of resin uptake in the skin and skin/core interphase affects the bending and shear performance of the sandwich composites when replacing the low strength and ductile core (conventional core) with a high strength and brittle core (FDM printed PLA (polylactic acid) core) still remains unclear. A new manufacturing routine is needed to improve the incorporation of FDM printed polymers in composite structures. In this work, FDM printed PLA was used as core material and sandwiched between two unidirectional glass fiber reinforced polymer (GFRP) skins to form a sandwich composite by compression-molding (CM) process, which provides a good manufacturing strategy for skin/core interphase modification. The significance of the CM process is proved by investigating the effect of resin uptake on bending and in-plane/out-of-plane shear performances. Current first order shear deformation (FSDT) theory lacks a direct connection between the in-plane shear stress and out-of-shear stress in the core region of sandwich composites. With the help of DIC, a connection between the in-plane shear and the out-of-plane shear strain was built and in-plane shear properties can acquire through out-of-plane shear properties, hence reducing the redundancy of sample preparation or the need for simulation. A significant improvement was found compared with the optimized resin uptake (Optimized resin uptake range: 20.43%–22.86 wt%) 3D-printed PLA core sandwich composite and lowest performance sandwich composite (Improvement: in-plane shear strength (~34%)/modulus (~29%), out-of-plane shear strength (~25%)/modulus (~31%), specific peak bending load (~19%)). Finally, compared with balsa core sandwich composites, the 3D-printed cores are suitable for use in composite sandwich structures in many applications with a satisfactory strength-to-weight ratio.