Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Instrumentation of sampling aircraft for measurement of launch vehicle effluents

An aircraft was selected and instrumented to measure effluents emitted from large solid propellant rockets during launch activities. The considerations involved in aircraft selection, sampling probes, and instrumentation are discussed with respect to obtaining valid airborne measurements. Discussions of the data acquisition system used, the instrument power system, and operational sampling procedures are included. Representative measurements obtained from an actual rocket launch monitoring activity are also presented.

Wornom, D. E.↗

The analysis of ocean optical data

A new oceanographic instrument to measure underwater optical, biological and physical properties simultaneously has been built and used extensively at sea. The Bio-Optical Profiling System (BOPS) was designed for the rapid acquisition of data to accommodate shipboard 'synoptic' sampling strategies, often in conjunction with concurrent aircraft and satellite sensors. The data rates and associated quantity of data from the BOPS are some orders of magnitude larger than those traditionally encountered in optical oceanography. The rapid acquisition of optical data in a wide range of environmental conditions requires new methodologies in ocean optical data analysis.

Smith, R. C.↗

Sampling tool concepts for Enceladus Lander in-situ analysis

A potential future in-situ lander mission to the surface of Enceladus could be the lowest cost mission to determine if life exists beyond Earth since material from the subsurface ocean, where the presence of hydrothermal activity has been strongly suggested by the Cassini mission, is available on its surface after being ejected by plumes and then settling on the surface. In addition, the low radiation environment of Enceladus would not significantly alter the chemical makeup of samples recently deposited on the surface. A study was conducted to explore various sampling devices that could be used by an in-situ lander mission to provide 1cc to 5cc volume samples to instruments. In addition to temperature and vacuum environmental conditions, the low surface gravity of Enceladus (1% of Earth gravity) represents a new challenge for surface sampling that is not met by sampling systems developed for microgravity (e.g., comets and asteroids) or higher gravity (e.g., Europa 13%g, Moon 16%g, or Mars 38%g) environments. It is desired to acquire surface plume material that has accumulated in the top 1cm to ensure acquisition of the least processed material. Several sampling devices were developed or adapted and then tested in simulated conditions that resemble the Enceladus surface properties. These devices and test results are presented in this paper.

Genta, Giancarlo↗

Structure-Driven Liquid Microjunction Surface-Sampling Probe Mass Spectrometry

The rhizosphere is the narrow region of soil surrounding the roots of plants that is influenced by root exudates, root secretions, and associated microbial communities. This region is crucial to plant growth and development and plays a critical role in nutrient uptake, disease resistance, and soil transformation. Understanding the function of exogenous compounds in the rhizosphere starts with determining the spatiotemporal distribution of these molecular components. Using liquid microjunction surface-sampling probe mass spectrometry (LMJ-SSP-MS) and microfluidic devices with attached microporous membranes enables in situ, nondisruptive, and nondestructive spatiotemporal measurement of exogenous compounds from plant roots. However, long imaging times (>2 h) can negatively affect plant heath and limit temporal studies. Here, we present a novel strategy to optimize the number and location of sampling sites on these microporous membrane-covered microfluidic devices. In conclusion, this novel, “structure-driven” sampling workflow takes into consideration the channel structure of the microfluidic device to maximize sampling from the channels and minimize acquisition time (~4× less time in some cases while providing similar chemical image accuracy), thus reducing stress on plants during in situ LMJ-SSP-MS analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrasparse View X-ray Computed Tomography for 4D Imaging

X-ray computed tomography (CT) is a noninvasive, nondestructive approach to imaging materials, material systems, and engineered components in two and three dimensions. Acquisition of three-dimensional (3D) images requires the collection of hundreds or thousands of through-thickness X-ray radiographic images from different angles. Such 3D data acquisition strategies commonly involve suboptimal temporal sampling for in situ and operando studies (4D imaging). Herein, we introduce a sparse-view imaging approach, Tomo-NeRF, which is capable of reconstructing high-fidelity 3D images from <10 twodimensional radiographic images. Experimental 2D and 3D X-ray images were used to test the reconstruction capability in two-view, four-view, and six-view scenarios. Tomo-NeRF is capable of reconstructing 3D images with a structural similarity of 0.9971–0.9975 and a voxel-wise accuracy of 81.83–89.59% from 2D experimentally obtained images. Furthermore, the reconstruction accuracy for the experimentally obtained images is less than the synthetic structures. Experimentally obtained images demonstrate a similarity of 0.9973–0.9984 and a voxelwise accuracy of 84.31–95.77%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Megahertz single-particle imaging at the European XFEL

The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL is expected to provide 27,000 pulses per second, over two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The results obtained pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.

36 MATERIALS SCIENCE↗

Investigation of Nanoparticle Degradation in Hydrogen Fuel Cell Systems through Automated Electron Microscopy

Proton exchange membrane fuel cells (PEMFC) are promising devices for the deployment of hydrogen-powered heavy-duty vehicles, providing a higher efficiency for similar driving range and fueling time than the existing ones. However, PEMFCs still encounter durability challenges mainly due to catalyst degradation in the cathode. Mitigating these performance losses requires a better understanding of the degradation mechanisms under heavy-duty accelerated stress tests (ASTs) [1]. Scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDS) are key tools for the analysis of Pt and PtCo nanoparticle size, spatial distribution and composition [2]. Electron tomography is also used to determine the rate and type of degradation of catalyst nanoparticles as a function of their position on the carbon support. In this work, automated data acquisition software, paired with a custom Python code, have been used to study the effect of different accelerated stress tests (ASTs) on nanoparticle coarsening [2]. Figure 1 shows high-angle annular dark-field (HAADF)-STEM images and EDS maps comparing the cathodes of membrane electrode assemblies (MEAs) following an electrocatalyst AST performed under H2/N2 with that of the heavy-duty AST performed under H2/air. We will discuss how AST conditions affect considerably the spatial distribution of the nanoparticles across the electrode between the membrane and microporous layer. Although the median particle size increased more in the MEA aged under the heavy-duty AST, as determined using a high-throughput image analysis, the quantitative EDS measurements demonstrate that the electrocatalyst AST resulted in more Pt and Co dissolution from the cathode, which is another important indicator of electrocatalyst degradation. We will further present the impact of the relative humidity (% RH) on the degradation mechanisms demonstrated using the same approach. Electron tomography has been used to distinguish the Pt nanoparticles residing on the carbon support surface (exterior) from those within the pore structure (interior) in order to determine the relative stability of interior and exterior nanoparticles. As shown in Figure 2, we will compare the Pt catalyst particle size at the beginning of test (BOT) and end of test (EOT), and discuss the importance of automating the electron tomography workflow, i.e. acquisition, reconstruction, and visualization, to increase sampling and determine the standard deviation of these measurement. The outlook for utilizing low-dose cryo-tomography for limiting damage to the catalyst, support, and especially proton-conducting ionomer will also be discussed [3].

Amichi, Lynda↗

Resonant ultrasound spectroscopy probe for in-situ neutron scattering measurements

Resonant ultrasound spectroscopy (RUS) is an efficient, nondestructive technique to study the elastic properties of solids. A low-temperature (2-300 K) probe has been assembled and tested at the NOMAD beamline at the Spallation Neutron Source at Oak Ridge National Laboratory to assess the probe's neutronic properties, data acquisition system, and compatibility with existing sample environment. A case study on a bulk metallic glass, La 65 Cu 20 Al 10 Co 5, served to benchmark both hardware and software developments. The elastic constants of the metallic glass were determined as a function of temperature between 4 and 300 K and were used to guide neutron diffraction measurements at NOMAD. Tracking of a specific RUS peak center frequency and width enabled live monitoring of the sample temperature evolution that lagged thermometry by upwards of 40 K near room temperature. Assembly of a high-temperature (300-875 K) probe is underway and both probes are scheduled to be available to users by late-2021. Our aim is to provide users with live monitoring of an intrinsic variable at the neutron scattering beamlines, in addition to existing controls, to monitor the state of their samples and its elastic moduli and make informed decisions in real time.

Torres, James↗

Vibration-Based Sensor Design: A Grey-Box Approach

Knowledge of the internal structure of an object or device under investigation proceeds from the basic idea of constructing its dynamic behavioral relations governed by a set of differential/algebraic equations that characterize its response. These equations can be partial differential equations leading to finite element or finite difference relations requiring a complex numerical solution on a super computer or ordinary differential equations requiring sophisticated numerical integration techniques to obtain the desired solution. Discrete dynamic systems evolving from digitized data acquisition are typically captured by sampled-data (continuous-to-discrete) representations characterized by a set of difference equations specifying the underlying system dynamics. In any case, with a mathematical description in hand, Grey-Box modeling techniques have evolved, concerned with the estimation of model parameters embedded in a prescribed set of equations (the system) governing its behavior, while capturing the underlying physical phenomenology of the problem at hand.

97 MATHEMATICS AND COMPUTING↗

Deep Active Learning for Solvability Prediction in Power Systems

Traditional methods for solvability region analysis can only have inner approximations with inconclusive conservatism and handle limited types of power flow models. In this letter, we propose a deep active learning framework for solvability prediction in power systems. Compared with passive learning where the training is performed after all instances are labeled, active learning selects most informative instances to be labeled and therefore significantly reduces the size of the labeled dataset for training. In the active learning framework, the acquisition functions, which correspond to different sampling strategies, are defined in terms of the on-the-fly posterior probability from the classifier. First, the IEEE 39-bus system is employed to validate the proposed framework, where a two-dimensional case is illustrated to visualize the effectiveness of the sampling method followed by the high-dimensional numerical experiments. Then, the Northeast Power Coordinating Council (NPCC) 140-bus system is used to validate the performance on large-scale power systems.

42 ENGINEERING↗

Water monitor system: Phase 1 test report

Automatic water monitor system was tested with the objectives of assuring high-quality effluent standards and accelerating the practice of reclamation and reuse of water. The NASA water monitor system is described. Various components of the system, including the necessary sensors, the sample collection system, and the data acquisition and display system, are discussed. The test facility and the analysis methods are described. Test results are reviewed, and recommendations for water monitor system design improvement are presented.

Taylor, R. E.↗

INFORM: An interactive data collection and display program with debugging capability

A computer program was developed to aid ASSEMBLY language programmers of mini and micro computers in solving the man machine communications problems that exist when scaled integers are involved. In addition to producing displays of quasi-steady state values, INFORM provides an interactive mode for debugging programs, making program patches, and modifying the displays. Auxiliary routines SAMPLE and DATAO add dynamic data acquisition and high speed dynamic display capability to the program. Programming information and flow charts to aid in implementing INFORM on various machines together with descriptions of all supportive software are provided. Program modifications to satisfy the individual user's needs are considered.

Cwynar, D. S.↗

Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples

This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to support our analytical facilities for extraterrestrial samples. After evaluating several instruments, we purchased a JEOL 6500F thermal field emission SEM with the following analytical accessories: EDAX energy-dispersive x-ray analysis system with fully automated control of instrument and sample stage; EDAX LEXS wavelength-dispersive x-ray spectrometer for high sensitivity light-element analysis; EDAX/TSL electron backscatter diffraction (EBSD) system with software for phase identification and crystal orientation mapping; Robinson backscatter electron detector; and an in situ micro-manipulator (Kleindiek). The total price was $550,000 (with $150,000 of the purchase supported by Carnegie institution matching funds). The microscope was delivered in October 2002, and most of the analytical accessories were installed by January 2003. With the exception of the wavelength spectrometer (which has been undergoing design changes) everything is working well and the SEM is in routine use in our laboratory.

Nittler, Larry R.↗

Indigenous and Contaminant Microbes in Ultradeep Mines

Rock, air and service water samples were collected for microbial analyses from 3.2 kilometers depth in a working Au mine in the Witwatersrand basin, South Africa. The approx. 1 meter wide mined zone was comprised of a carbonaceous, quartz, sulfide, uraninite and Au bearing layer, called the Carbon Leader, sandwiched by quartzite and conglomerates. The microbial community in the service water was dominated by mesophilic aerobic and anaerobic, alpha, beta and gamma-Proteobacteria with a total biomass concentration approx. l0(exp 4) cells/ ml, whereas, that of the mine air was dominated by members of the Chlorobi and Bacteroidetes groups and a fungal component. The microorganisms in the Carbon Leader were predominantly mesophilic, aerobic heterotrophic, nitrate reducing and methylotrophic, beta and gamma - Proteobacteria that were more closely related to service water microorganisms rather than air microbes. Rhodamine WT dye and fluorescent microspheres employed as contaminant tracers, however, indicated that service water contamination of most of the rock samples was less that 0.01% during acquisition. The microbial contaminants most likely originated from the service water, infiltrated the low permeability rock through and accumulated within mining-induced fractures where they survived for several days prior to being mined. Combined PLFA and terminal restriction fragment length profile (T-RFLP) analyses suggest that the maximum concentration of indigenous microorganisms in the Carbon Leader was less than lo(exp 2) cells/ g. PLFA, S-35 autoradiography and enrichments suggest that the adjacent quartzite was less contaminated and contained -10(exp 3) cells/gram of a thermophilic, sulfate reducing bacteria, SRB, some of who are delta Proteobacteria. Pore water and rock geochemical analyses suggest that these SRB's may have been sustained by sulfate diffusing from the adjacent U-rich, Carbon Leader where it was formed by radiolysis of sulfide.

Onstott, T. C.↗

The Kalai-Smorodinsky solution for many-objective Bayesian optimization

An ongoing aim of research in multiobjective Bayesian optimization is to extend its applicability to a large number of objectives. While coping with a limited budget of evaluations, recovering the set of optimal compromise solutions generally requires numerous observations and is less interpretable since this set tends to grow larger with the number of objectives. We thus propose to focus on a specific solution originating from game theory, the Kalai-Smorodinsky solution, which possesses attractive properties. In particular, it ensures equal marginal gains over all objectives. We further make it insensitive to a monotonic transformation of the objectives by considering the objectives in the copula space. A novel tailored algorithm is proposed to search for the solution, in the form of a Bayesian optimization algorithm: sequential sampling decisions are made based on acquisition functions that derive from an instrumental Gaussian process prior. Our approach is tested on four problems with respectively four, six, eight, and nine objectives. The method is available in the R package GPGame available on CRAN at https://cran.r-project.org/package=GPGame.

Game theory↗

A versatile X-ray phase retarder for lock-in XMCD measurements

X-ray magnetic circular dichroism (XMCD) is a technique commonly used to probe magnetic properties of materials with element and orbital selectivity, which requires the use of circularly polarized (CP) X-rays. It is possible to accomplish XMCD experiments with fixed CP and alternating the magnetic field orientation, but most reliable data are obtained when alternating the magnetization orientation and the polarization between right and left helicities. A versatile strategy has been developed to perform XMCD experiments using a hard X-ray quarter-wave plate, at both polychromatic dispersive and conventional monochromatic optics, in combination with synchronous data acquisition. The switching frequency waveform is fed into a lock-in amplifier to detect and amplify the XMCD signal. The results on a reference sample demonstrate an improvement in data quality and acquisition time. The instrumentation successfully generated 98% of CP X-rays switching the beam helicity at 13 Hz, with the possibility of faster helicity switching once it is installed at the new Brazilian fourth-generation source, SIRIUS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reward based optimization of resonance-enhanced piezoresponse spectroscopy

Dynamic spectroscopies in scanning probe microscopy (SPM) are critical for probing material properties, such as force interactions, mechanical properties, polarization switching, electrochemical reactions, and ionic dynamics. However, the practical implementation of these measurements is constrained by the need to balance imaging time and data quality. Signal to noise requirements favor long acquisition times and high frequencies to improve signal fidelity. However, these are limited on the low end by contact resonant frequency and photodiode sensitivity and on the high end by the time needed to acquire high-resolution spectra or the propensity for sample degradation under high field excitation over long times. The interdependence of key parameters such as instrument settings, acquisition times, and sampling rates makes manual tuning labor-intensive and highly dependent on user expertise, often yielding operator-dependent results. These limitations are prominent in techniques like dual amplitude resonance tracking in piezoresponse force microscopy that utilize multiple concurrent feedback loops for topography and resonance frequency tracking. Here, a reward-driven workflow is proposed that automates the tuning process, adapting experimental conditions in real time to optimize data quality. Furthermore, this approach significantly reduces the complexity and time required for manual adjustments and can be extended to other SPM spectroscopic methods, enhancing overall efficiency and reproducibility.

47 OTHER INSTRUMENTATION↗

Agilent AgileBioFoundry CRADA (Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOF-MS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Therefore, our accomplishment in this CRADA improved the efficiency and accuracy of strain testing by developing and implementing fast analytical methods, robust processing tools, and software for predicting the best methods for UHPLC analysis.

97 MATHEMATICS AND COMPUTING↗