Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Methane monitoring and detection apparatus and methods

A low cost, low power, passive optical methane monitoring system for fixed-position installation at oil and gas production well pads and gathering centers is disclosed. The optical methane monitoring system disclosed can be a scannable field of view Near Infrared (NIR) filter photometer to detect and quantify methane concentration in a two dimensional or a three dimensional grid above and around a facility. A randomized fiber optic bundle is disclosed that can be used to direct the total optical power from a collection lens to two or more isolated optical channels. Band pass filters isolate a desired wavelength range for transmission measurements for the two or more channels. Also disclosed is an absorption algorithm which accounts for variable background spectral intensity as well as correcting for water vapor and overall scattering effects to measure methane concentration for a given field of view.

Lievois, John↗

Detailed characterization of a five-dimensional phase space distribution

We image the five-dimensional phase space distribution of a hadron beam in unprecedented detail. The resolution and dynamic range of the measurement are sufficient to resolve sharp, high-dimensional features in low-density regions of phase space. We develop several visualization techniques, including non-planar slicing, to facilitate the identification and analysis of such features. We use these techniques to examine the transverse dependence of longitudinal hollowing and the longitudinal dependence of transverse hollowing in the distribution. Our results strengthen the claim that low-dimensional projections do not adequately characterize high-dimensional phase space distributions.

Hoover, Austin↗

Low Tidal Current Speed Electricity Generation for Power at an Aquaculture Farm

Aquaculture farms are often located where tidal currents speeds are strong enough to ensure the currents supply fresh nutrients but not so strong that they harm the farm infrastructure. Traditional tidal turbines have cut-in speeds of 1 m/s and cannot generate electricity at current speeds below that threshold. Current energy converters that rely on vortex induced vibration (VIV) for movement can generate electricity at current speeds below 1 m/s. Here we discuss a project where researchers from the Pacific Northwest National Laboratory (PNNL) collaborate with researchers from the University of Michigan to investigate the feasibility of using a VIV current energy converter to generate electricity at an aquaculture farm. The VIV current energy converter uses flow induced oscillations of tandem cylinders and adaptive damping to harness the maximum horizontal marine hydrokinetic (MHK) energy by mimicking fish undulations. The current energy converter will be field tested and its power output measured over a range of current speeds. In addition to working with the University of Michigan, the PNNL researchers are collaborating with the Hog Island Oyster Company to assess their electricity usage and quantify the current energy resources at their Humboldt Bay facility. The electricity usage and current resource assessment at the aquaculture farm will be compared to the power produced by VIVACE to determine the feasibility of using VIVACE for power production at the farm.

Branch, Ruth A.↗

First-of-a-Kind Fuel-bearing Molten Chloride Irradiation Experiment

As a dozen MSR developers in the U.S. work toward an aggressive commercialization timeline, many of their fueled-salts—notably, chloride-based compositions—have never been irradiated. Licensing and operating these reactors requires an understanding of (1) the source term, radiation chemistry, and gas generation; (2) unanticipated irradiation-induced corrosion effects; and (3) the impact of burnup on thermophysical properties, all of which can be deduced through irradiation testing. Idaho National Laboratory (INL) is ideally suited to leverage its expertise in chloride salt chemistry, as well as its Neutron Radiography Reactor (NRAD) facility in the Hot Fuels Examination Facility (HFEF) at the Materials and Fuels Complex (MFC), to conduct the world’s first fuel-bearing chloride salt irradiation and fill in the knowledge gaps pertaining to salt chemistry under irradiation. Molten-salt Research Temperature-controlled Irradiation (MRTI) consists of a salt-containing capsule that is internally heated inside of a secondary containment. The experiment must rely on resistive heating to melt the salt before irradiation (to avoid the impact of radiolysis) and once the reactor is turned on and fission reactions commence in the salt, the resistive power can then be reduced. Salt-immersed thermocouples coupled to a controller allow for the heater power to be adjusted as needed to meet experimental objectives. The bulk of the experimental results will be achieved through Post-Irradiation Examination (PIE). At which point a range of different measurements are anticipated to assess the salt/plenum/wall composition, the capsule corrosion rate, and the evolution of salt properties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reversed-direction 2-point modelling applied to divertor conditions in DIII-D *

Abstract A predictive form of the extended 2-point model known as the ‘reverse 2-point model’, Rev2PM, is applied to a range of detachment levels in the open lower divertor of DIII-D, showing that the experimentally measured electron temperature ( T e ) and pressure ( p e ) at the divertor entrance can be calculated within 50% from target measurements, if and only if a posteriori corrections for convective heat flux are included in the model. Unlike the standard 2-point model, the Rev2PM calculates upstream scrape-off layer (SOL) quantities (such as separatrix T e and p e ) from target conditions (such as T e and parallel heat flux), with volumetric power and momentum losses depending solely on target T e . The Rev2PM is tested against a database of DIII-D inter-ELM divertor Thomson scattering measurements, built from a series of 6 MW, 1.3 MA, LSN H-mode discharges with varied main ion density, drift direction, and nitrogen puffing rate. Measured target T e ranged from 0.4–25 eV over this database, and upstream T e ranged from 5–60 eV. Poor agreement is found between upstream measurements and Rev2PM calculations that assume purely conductive parallel heat transport. However, introducing a posteriori corrections to account for convective heat transport brings the Rev2PM calculations within 50% of the measured upstream values across the dataset. These corrections imply that up to 99% of the parallel heat flux is carried by convection in detached conditions in the DIII-D open lower divertor, though further work is required to assess any potential dependencies on device size or divertor closure.

2-point model↗

Conductive Spray Paint Fabricated Cylindrical Coplanar Waveguide for Noncontact Liquid-Level Sensing

A noncontact liquid-level sensor using a cylindrical coplanar waveguide (CCPW) is proposed. The concept is demonstrated using a prototype device made by directly spraying conductive paint on the outer surface of a glass cylinder. The position of the air–liquid interface is measured using the time-domain reflection (TDR) signal from the CCPW. The geometric parameters of the prototype sensor were optimized using a full-wave simulation tool. The experimental results show that the prototype CCPW-based liquid-level sensor has a resolution of 29.8μm over a range of 210 mm at the sweeping frequency bandwidth of 500 MHz–4 GHz. The tradeoff between the resolution and the measurement range was discussed. The proposed sensor provides a low-cost, easy-to-fabricate, and noncontact method for liquid-level measurement, which has potential applications in fuel storage, chemical production, and wastewater treatment.

42 ENGINEERING↗

Rapid measurement of RH-dependent aerosol hygroscopic growth using a humidity-controlled fast integrated mobility spectrometer (HFIMS)

Abstract. The ability of aerosol particles to uptake water (hygroscopic growth) is an important determinant of aerosol optical properties and radiative effects. Aerosol hygroscopic growth is traditionally measured by humidified tandem differential mobility analyzers (HTDMA), in which size-selected dry particles are exposed to elevated relative humidity (RH), and the size distribution of humidified particles is subsequently measured using a scanning mobility particle sizer. As a scanning mobility particle sizer can measure only one particle size at a time, HTDMA measurements are time consuming, and ambient measurements are often limited to a single RH level. Pinterich et al. (2017b) showed that fast measurements of aerosol hygroscopic growth are possible using a humidity-controlled fast integrated mobility spectrometer (HFIMS). In HFIMS, the size distribution of humidified particles is rapidly captured by a water-based fast integrated mobility spectrometer (WFIMS), leading to a factor of ∼10 increase in measurement time resolution. In this study we present a prototype HFIMS that extends fast hygroscopic growth measurements to a wide range of atmospherically relevant RH values, allowing for more comprehensive characterizations of aerosol hygroscopic growth. A dual-channel humidifier consisting of two humidity conditioners in parallel is employed such that aerosol RH can be quickly stepped among different RH levels by sampling from alternating conditioners. The measurement sequence is also optimized to minimize the transition time between different particle sizes. The HFIMS is capable of measuring aerosol hygroscopic growth of six particle diameters under five RH levels ranging from 20 % to 85 % (30 separate measurements) every 25 min. The performance of this HFIMS is characterized and validated using laboratory-generated ammonium sulfate aerosol standards. Measurements of ambient aerosols are shown to demonstrate the capability of HFIMS to capture the rapid evolution of aerosol hygroscopic growth and its dependence on both size and RH.

54 ENVIRONMENTAL SCIENCES↗

Scaling Properties of φ -Meson and Light Charged Hadron Production in Small and Large Systems at PHENIX

Recent results on the identified charged-hadron (π ± , K ± , p, p¯) production vat midrapidity region (|η| < 0.35) have been measured by the PHENIX experiment in p + Al, 3 He + Au, Cu + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV and U + U collisions at $\sqrt{s_{NN}}$ = 193 GeV. These measurements are presented through the invariant transverse-momentum (p T ) and transverse-mass (m T ) spectra for different collision centralities. The averaged freeze-out temperature value for different systems was found to be 166.1 ± 2.2 MeV, and do not exhibit any dependence on the collision centrality and $\langle$N parti $\rangle$ values. The particle ratios of K/π and p/π have been measured in different centrality ranges of large and small collision systems. The values of K/π ratios measured in all considered collision systems were found to be consistent with those measured in p+p collisions. Furthermore, the identified charged-hadron nuclear-modification factors (R AB ) are also presented. Enhancement of proton R AB values over meson R AB values was observed in central 3 He+Au, Cu+Au, and U+U collisions. The proton R AB values measured in p+Al collision system were found to be consistent with R AB values of Φ, π ± , K ± , and π 0 mesons, suggesting that the size of the system produced in p+Al collisions is too small for recombination to cause a noticeable increase in proton production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-Range Transverse-Momentum Correlations and Radial Flow in Pb-Pb Collisions at the LHC

This Letter presents measurements of long-range transverse-momentum correlations using a new observable, 𝑣 0⁡ (𝑝 T ), serving as a probe of event-by-event radial-flow fluctuations, the underlying radial expansion, and the medium’s properties in heavy-ion collisions. Results are reported for inclusive charged particles, pions, kaons, and protons across various centrality intervals in Pb-Pb collisions at $\sqrt{𝑠_{\textrm{NN}}}$ = 5.02 TeV, recorded by the ALICE detector. A pseudorapidity-gap technique, similar to that used in anisotropic-flow studies, is employed to suppress short-range correlations. At low 𝑝 T , a characteristic mass ordering consistent with hydrodynamic collective flow is observed. At higher 𝑝 T (>3 GeV/𝑐), protons exhibit larger 𝑣 0 ⁡(𝑝 T ) than pions and kaons, in agreement with expectations from quark-recombination models. Comparisons to viscous hydrodynamic calculations with varying bulk viscosity and equation of state demonstrate the sensitivity of the 𝑣 0 ⁡(𝑝 T ) observable to these key medium properties. The findings establish 𝑣 0 ⁡(𝑝 T ) as a valuable addition to the set of observables used in Bayesian analyses for extracting the transport properties and constraining the equation of state of strongly interacting matter, while also helping to systematically explore its sensitivity and impact within such global studies.

Acharya, S. [INFN] (ORCID:0000000292135329)↗

Hydrate is a Nonwetting Phase in Porous Media

In porous media containing gas hydrate, the hydrate morphology impacts the flow behavior of the fluid phases. We hypothesize that hydrate emplaces itself as a nonwetting phase and use this idea to describe relative permeability of water in a hydrate/water system. We perform steady-state relative permeability measurements in hydrate-bearing samples with a range of hydrate saturation. We measure and compare water relative permeability in the presence of gas and in the presence of hydrate and find that the water relative permeability is the same in both cases. This suggests that (1) relative permeability for hydrate systems can be obtained without performing difficult experiments on hydrate bearing sediments, (2) flow properties are porous-media dependent, and (3) models that assume a fixed pore or tube geometry are inadequate.

58 GEOSCIENCES↗

Results on elastic cross sections in proton–proton collisions at $\sqrt{s}$ = 510 GeV with the STAR detector at RHIC

We report results on an elastic cross section measurement in proton–proton collisions at a center-of-mass energy $\sqrt{s}$ = 510 GeV, obtained with the Roman Pot setup of the STAR experiment at the Relativistic Heavy Ion Collider (RHIC). The elastic differential cross section is measured in the four-momentum transfer squared range 0.23 ≤ −t ≤ 0.67 GeV 2 . This is the only measurement of the proton-proton elastic cross section in this t range for collision energies above the Intersecting Storage Rings (ISR) and below the Large Hadron Collider (LHC) colliders. We find that a constant slope B does not fit the data in the aforementioned t range, and we obtain a much better fit using a second-order polynomial for B(t). This is the first measurement below the LHC energies for which the non-constant behavior B(t) is observed. The t dependence of B is also determined using six subintervals of t in the STAR measured t range, and is in good agreement with the phenomenological models. The measured elastic differential cross section dσ/dt agrees well with the results obtained at $\sqrt{s}$ = 540 GeV for proton–antiproton collisions by the UA4 experiment. We also determine that the integrated elastic cross section within the STAR t-range is σ$^{fid}_{el}$ = 462.1 ± 0.9(stat.) ± 1.1(syst.) ± 11.6(scale) μb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

Time-lens photon Doppler velocimetry (TL-PDV)

Here, we describe a time lens (TL) to expand the dynamic range of photon Doppler velocimetry (PDV) systems. The principle and preliminary design of a TL-PDV system are explained and shown to be feasible through simulations. In a PDV system, an interferometer is used for measuring frequency shifts due to the Doppler effect from the target motion. However, the sampling rate of the electronics could limit the velocity range of a PDV system. A four-wave-mixing (FWM) TL applies a quadratic temporal phase to an optical signal within a nonlinear FWM medium (such as an integrated photonic waveguide or a highly nonlinear optical fiber). By spectrally isolating the mixing product, termed the idler, and with appropriate lengths of dispersion prior to and after this FWM TL, a temporally magnified version of the input signal is generated. Therefore, the frequency shifts of PDV can be “slowed down” with the magnification factor M of the TL. M = 1 corresponds to a regular PDV system without a TL. M = 10 has been shown to be feasible for a TL-PDV system. The use of this effect for PDV can expand the velocity measurement range and allow for the use of lower bandwidth electronics. TL-PDV will open up new avenues for various dynamic material experiments.

47 OTHER INSTRUMENTATION↗

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

Determination of confinement regime boundaries via separatrix parameters on Alcator C-Mod based on a model for interchange-drift-Alfvén turbulence

The separatrix operational space (SepOS) model (Eich and Manz 2021 Nucl. Fusion 61 086017) is shown to predict the L–H transition, the L-mode density limit, and the ideal magnetohydrodynamic ballooning limit in terms of separatrix parameters for a wide range of Alcator C-Mod plasmas. The model is tested using Thomson scattering measurements across a wide range of operating conditions on C-Mod, spanning $\overline{n}_{\mathrm{e}}$ = 0.3–5.5 $\times 10^{20}\,$m −3 , $B_{\mathrm{t}} = 2.5$–8.0 T, and $B_{\mathrm{p}}$= 0.1–1.2 T. An empirical regression for the electron pressure gradient scale length, $\lambda_{{p}_{\mathrm{e}}}$, against a turbulence control parameter, $\alpha_{\mathrm{t}}$, and the poloidal fluid gyroradius, $\rho_{\mathrm{s,p}}$, is constructed for H-modes and found to require positive exponents for both regression parameters, indicating turbulence widening of near-scrape-off layer widths at high $\alpha_{\mathrm{t}}$ and an inverse scaling with $B_{\mathrm{p}}$, consistent with results on ASDEX Upgrade. The SepOS model is also tested in the unfavorable drift direction and found to apply well to all three boundaries, including the L–H transition as long as a correction to the Reynolds energy transfer term, $\alpha_\mathrm{RS} \lt 1$ is applied. I-modes typically exist in the unfavorable drift direction for values of $\alpha_{\mathrm{t}} \lesssim 0.3$. Finally, an experiment studying the transition between the Type-I ELMy and EDA H-mode is analyzed using the same framework. It is found that a recently identified boundary $\alpha_{\mathrm{t}} = 0.55$ at excludes most EDA H-modes but that the balance of wavenumbers responsible for the L-mode density limit, namely $k_\mathrm{EM} = k_\mathrm{RBM}$, may better describe the transition on C-Mod. The ensemble of boundaries validated and explored is then applied to project regime access and limit avoidance for the SPARC primary reference discharge parameters.

ELM suppression↗

Photoproduction of the Σ + hyperon using linearly polarized photons with CLAS

Measurements of the polarization observables Σ, P, T, O x , O z for the reaction $\vec{γ}$ p → $K^0_S$Σ + using a linearly polarized photon beam of energy 1.1 to 2.1 GeV are reported. The measured data provide information on a channel that has not been studied extensively, but is required for a full coupled-channel analysis in the nucleon resonance region. Observables have been simultaneously extracted using likelihood sampling with a Markov-Chain Monte Carlo process. Angular distributions in bins of photon energy E γ are produced for each polarization observable. T, O x , and O z are first time measurements of these observables in this reaction. The extraction of Σ extends the energy range beyond a previous measurement. The measurement of P, the recoil polarization, is consistent with previous measurements. The measured data are shown to be significant enough to affect the estimation of the nucleon resonance parameters when fitted within a coupled-channels model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The heat transfer coefficient associated with a moving packed bed of silica particles flowing through parallel plates

Concentrating Solar Power (CSP) with thermal energy storage has the potential to be a renewable energy technology with long duration, inexpensive energy storage. Higher temperature operation increases the conversion efficiency and reduces the cost of energy storage. Several emerging CSP designs utilize particles as the solar receiver due to their high temperature stability and low cost. In some designs, the particles are also used as the thermal energy storage (TES) media. In either configuration, an energy transfer is required between the hot particles and the working fluid in the power cycle in a Particle-to-Fluid Heat Exchanger (PtFHX). Understanding the heat transfer between a moving packed bed and a stationary surface is critical to the successful design of a PtFHX. In this paper, a test facility is described in which a moving packed bed of silica sand with particle size 100–600 μm is introduced into the channel formed by two parallel plates, one of which is heated. The effective static thermal conductivity of the particles used for the test are separately measured over the entire range of test temperatures. The inlet and outlet bulk temperatures of the particle flow are measured as are the surface temperatures at several axial locations along the centerline of the plate. The result is the measurement of heat transfer coefficient as a function of temperature for several velocities. The uncertainty of the measurements is presented and the results are compared to model results found in the literature.

14 SOLAR ENERGY↗