NASA Tech Briefs, November 2011

The topics include: 1) Flight Test Results from the Rake Airflow Gage Experiment on the F-15B; 2) Telemetry and Science Data Software System; 3) CropEx Web-Based Agricultural Monitoring and Decision Support; 4) High-Performance Data Analysis Tools for Sun-Earth Connection Missions; 5) Experiment in Onboard Synthetic Aperture Radar Data Processing; 6) Microfabrication of a High-Throughput Nanochannel Delivery/Filtration System; 7) Improved Design and Fabrication of Hydrated-Salt Pills; 8) Monolithic Flexure Pre-Stressed Ultrasonic Horns; 9) Cryogenic Quenching Process for Electronic Part Screening; 10) Broadband Via-Less Microwave Crossover Using Microstrip-CPW Transitions; 11) Wheel-Based Ice Sensors for Road Vehicles; 12) G-DYN Multibody Dynamics Engine; 13) Multibody Simulation Software Testbed for Small-Body Exploration and Sampling; 14) Propulsive Reaction Control System Model; 15) Licklider Transmission Protocol Implementation; 16) Core Recursive Hierarchical Image Segmentation; 17) Two-Stage Centrifugal Fan; 18) Combined Structural and Trajectory Control of Variable-Geometry Planetary Entry Systems; 19) Pressure Regulator With Internal Ejector Circulation Pump, Flow and Pressure Measurement Porting, and Fuel Cell System Integration Options; 20) Temperature-Sensitive Coating Sensor Based on Hematite; 21) Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis; 22) Detection of Carbon Monoxide Using Polymer-Carbon Composite Films; 23) Substituted Quaternary Ammonium Salts Improve Low-Temperature Performance of Double-Layer Capacitors; 24) Sustainably Sourced, Thermally Resistant, Radiation Hard Biopolymer; 25) Integrated Lens Antennas for Multi-Pixel Receivers; 26) 180-GHz Interferometric Imager; 27) Maturation of Structural Health Management Systems for Solid Rocket Motors; 28) Validating Phasing and Geometry of Large Focal Plane Arrays; 29) Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration; 30) Qualification of Fiber Optic Cables for Martian Extreme Temperature Environments; 31) Solid-State Spectral Light Source System; 32) Multiple-Event, Single-Photon Counting Imaging Sensor; 33) Surface Modeling to Support Small-Body Spacecraft Exploration and Proximity Operations; and 34) Achieving Exact and Constant Turnaround Ratio in a DDS-Based Coherent Transponder.

Source record↗

Lightning detection from Space Science and Applications Team review

The various needs for lightning data that exist among potential users of satellite lightning data were identified and systems were defined which utilize the optical and radio frequency radiations from lightning to serve as the satellite based lightning mapper. Three teams worked interactively with NASA to develop a system concept. An assessment of the results may be summarized as follows: (1) a small sensor system can be easily designed to operate on a geostationary satellite that can provide the bulk of the real time user requirements; (2) radio frequency systems in space may be feasible but would be much larger and more costly; RF technology for this problem lags the optical technology by years; and (3) a hybrid approach (optical in space and RF on the ground) would provide the most complete information but is probably unreasonably complex and costly at this time.

Few, A. A., Jr.↗

Laboratory simulation of tunable diode laser remote measurement of atmospheric gases using topographic targets

In order to test the possibility that tunable diode laser (TDL) systems using topographic targets can be applied to the measurement of a variety of gases at concentrations and distances characteristic of industrial gas leaks, a single-ended TDL system was assembled for use with selected topographic targets to detect NO2 at atmospheric pressure and NO2 and NH3 at low pressures. In both cases, the intensity distribution of radiation backscattered from selected targets was found to be heavily weighted to a specular rather than a Lambertian distribution. A sensitivity of 5 ppm-m has been demonstrated for the case of NO2.

Webster, C. R.↗

Oxygen detection using the laser diode absorption technique

Accurate measurement of the concentration and flow rate of gaseous oxygen is becoming of greater importance. The detection technique presented is based on the principal of light absorption by the Oxygen A-Band. Oxygen molecules have characteristics which attenuate radiation in the 759-770 nm wavelength range. With an ability to measure changes in the relative light transmission to less than 0.01 percent, a sensitive optical gas detection system was configured. This system is smaller in size and light in weight, has low energy requirements and has a rapid response time. In this research program, the application of temperature tuning laser diodes and their ability to be wavelength shifted to a selected absorption spectral peak has allowed concentrations as low as 1300 ppm to be detected.

Disimile, P. J.↗

Wide Band Gap Radiation Detectors for Deep Space Science

Understanding how the Sun, Earth, and other objects in the solar system interact with the space radiation environment is crucial for improving activities of humans on Earth and in space. Low-power, low-noise, multidirectional robust detectors for detecting ions with a wide range of mass and energies will provide a more complete understanding of space environment physics. To meet these challenges, new ion detectors based on wide band gap (WBG) semiconductors are being developed for integration on a variety of deep space platforms. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies to enable improved instruments for space science missions. New detector technologies being developed at GRC include SiC solid-state devices as practical robust, thermally stable large area detectors for LET measurements in compact, stacked charged particle telescope. The low-noise, thermally stable nature of the WBG detectors allows a small multidirectional array of charged particle telescopes to be packed in a 6U CubeSat without active cooling for operation in lunar orbit or deep space. Using a full variety of different WBG detectors, an extremely compact instrument to provide multi-directional, comprehensive (composition, velocity, and direction) in-situ measurements of heavy ions in space plasma environments can be realized.

ion detectors↗

Differential detection of Gaussian MSK in a mobile radio environment

Minimum shift keying with Gaussian shaped transmit pulses is a strong candidate for a modulation technique that satisfies the stringent out-of-band radiated power requirements of the mobil radio application. Numerous studies and field experiments have been conducted by the Japanese on urban and suburban mobile radio channels with systems employing Gaussian minimum-shift keying (GMSK) transmission and differentially coherent reception. A comprehensive analytical treatment is presented of the performance of such systems emphasizing the important trade-offs among the various system design parameters such as transmit and receiver filter bandwidths and detection threshold level. It is shown that two-bit differential detection of GMSK is capable of offering far superior performance to the more conventional one-bit detection method both in the presence of an additive Gaussian noise background and Rician fading.

Simon, M. K.↗

Radiation Detection Technologies

When governing bodies seek to reduce the spread and development of nuclear material and weapons, arms control and safeguards technologies play an important role in preventing proliferation within a state that has already developed a nuclear weapon. Arms control treaties work to control the development, production, stockpiling, proliferation, distribution, or the usage of a certain weapon type or delivery system. Treaty guidelines are met using combinations of monitoring, detection, and verification technologies. 1 To verify compliance, a country must determine if the activities of another country are within the limits and obligations established by the treaty. A verifiable treaty contains an interlocking web of constraints and provisions designed to deter cheating, to make cheating more complicated and more expensive, or to make its detection timelier. In the past, the U.S. has deemed treaties to be effectively verifiable if there is confidence that significant violations can be detected in time to respond and offset any threat that the violation may create for the U.S.

61 RADIATION PROTECTION AND DOSIMETRY↗

Detection of DNA Damage by Space Radiation in Human Fibroblasts Flown on the International Space Station

Space radiation consists of energetic charged particles of varying charges and energies. Exposure of astronauts to space radiation on future long duration missions to Mars, or missions back to the Moon, is expected to result in deleterious consequences such as cancer and comprised central nervous system (CNS) functions. Space radiation can also cause mutation in microorganisms, and potentially influence the evolution of life in space. Measurement of the space radiation environment has been conducted since the very beginning of the space program. Compared to the quantification of the space radiation environment using physical detectors, reports on the direct measurement of biological consequences of space radiation exposure have been limited, due primarily to the low dose and low dose rate nature of the environment. Most of the biological assays fail to detect the radiation effects at acute doses that are lower than 5 centiSieverts. In a recent study, we flew cultured confluent human fibroblasts in mostly G1 phase of the cell cycle to the International Space Station (ISS). The cells were fixed in space after arriving on the ISS for 3 and 14 days, respectively. The fixed cells were later returned to the ground and subsequently stained with the gamma-H2AX (Histone family, member X) antibody that are commonly used as a marker for DNA damage, particularly DNA double strand breaks, induced by both low-and high-linear energy transfer radiation. In our present study, the gamma-H2AX (Histone family, member X) foci were captured with a laser confocal microscope. To confirm that some large track-like foci were from space radiation exposure, we also exposed, on the ground, the same type of cells to both low-and high-linear energy transfer protons, and high-linear energy transfer Fe ions. In addition, we exposed the cells to low dose rate gamma rays, in order to rule out the possibility that the large track-like foci can be induced by chronic low-linear energy transfer radiation.

Lu, Tao↗

Machine Learning Algorithms for Aerosol and Cloud Detection Using CATS on the ISS

Clouds and aerosols are one of the largest uncertainties in understanding and forecasting the Earth’s changing climate system. The type and height of aerosols are important factors in determining the top-of-atmosphere (TOA) radiation budget, either direct reflection of solar radiation back to space and/or absorption of solar radiation. In addition to their impact on the Earth’s climate system, aerosols near the surface from wildfires, man-made pollution events, and dust storms are hazardous to human health. The phase and height of clouds also play a critical role in determining the role of clouds in the Earth’s climate system. Cirrus clouds in the upper troposphere can induce a significant daytime TOA warming effect, while liquid water clouds near the surface cause a large corresponding cooling effect. Lidar measurements provide accurate vertically resolved information about clouds and aerosols, including complex multi-layer scenes where passive sensors are challenged and at night, when passive sensors are unable to measure cloud and aerosol properties. The Cloud-Aerosol Transport System (CATS) is a lidar instrument that operated for 33 months on the International Space Station (ISS) at the 1064 nm wavelength to measure attenuated total backscatter and depolarization ratio. These fundamental measurements are used to derive “vertical feature mask” cloud and aerosol products, including layer top/base heights, layer geometrical thickness, aerosol type, and cloud phase. While space-based lidar systems like CATS provide cloud and aerosol vertical distributions that improve our understanding of the climate system, averaging of the daytime data from these sensors is required, at the expense of spatial resolution, to improve the daytime signal-to noise (SNR) and thus atmospheric layer detection. This presentation shows results from machine learning (ML) techniques that, when applied to CATS data: 1. improve the 1064 nm SNR 2. enable detection of atmospheric features during daytime with a horizontal resolution of 350 m or 5 km (compared to the 60 km required for standard CATS data products) 3. increase the number of atmospheric layers detected in the CATS data. A Convolutional Neural Network (CNN) trained using CATS standard data products also demonstrated the potential for improved cloud-aerosol discrimination, cloud phase, and aerosol typing compared to the operational CATS algorithms for cloud edges and complex near-surface scenes during daytime. The ML tools described in this paper can facilitate the development of smaller, low-cost lidar systems in the future and enable real-time accessibility of lidar data products from future lidar systems for monitoring and forecasting of hazardous events.

John Yorks↗

First Test of Fan Active Noise Control (ANC) Completed

With the advent of ultrahigh-bypass engines, the space available for passive acoustic treatment is becoming more limited, whereas noise regulations are becoming more stringent. Active noise control (ANC) holds promise as a solution to this problem. It uses secondary (added) noise sources to reduce or eliminate the offending noise radiation. The first active noise control test on the low-speed fan test bed was a General Electric Company system designed to control either the exhaust or inlet fan tone. This system consists of a "ring source," an induct array of error microphones, and a control computer. Fan tone noise propagates in a duct in the form of spinning waves. These waves are detected by the microphone array, and the computer identifies their spinning structure. The computer then controls the "ring source" to generate waves that have the same spinning structure and amplitude, but 180 out of phase with the fan noise. This computer generated tone cancels the fan tone before it radiates from the duct and is heard in the far field. The "ring source" used in these tests is a cylindrical array of 16 flat-plate acoustic radiators that are driven by thin piezoceramic sheets bonded to their back surfaces. The resulting source can produce spinning waves up to mode 7 at levels high enough to cancel the fan tone. The control software is flexible enough to work on spinning mode orders from -6 to 6. In this test, the fan was configured to produce a tone of order 6. The complete modal (spinning and radial) structure of the tones was measured with two builtin sets of rotating microphone rakes. These rakes provide a measurement of the system performance independent from the control system error microphones. In addition, the far-field noise was measured with a semicircular array of 28 microphones. This test represents the first in a series of tests that demonstrate different active noise control concepts, each on a progressively more complicated modal structure. The tests are in preparation for a demonstration on a flight-type engine.

Source record↗

A VERITAS/Breakthrough Listen Search for Optical Technosignatures

The Breakthrough Listen Initiative is conducting a program using multiple telescopes around the world to search for “technosignatures”: artificial transmitters of extraterrestrial origin from beyond our solar system. The Very Energetic Radiation Imaging Telescope Array System (VERITAS) Collaboration joined this program in 2018 and provides the capability to search for one particular technosignature: optical pulses of a few nanoseconds in duration detectable over interstellar distances. We report here on the analysis and results of dedicated VERITAS observations of Breakthrough Listen targets conducted in 2019 and 2020 and of archival VERITAS data collected since 2012. Thirty hours of dedicated observations of 136 targets and 249 archival observations of 140 targets were analyzed and did not reveal any signals consistent with a technosignature. The results are used to place limits on the fraction of stars hosting transmitting civilizations. We also discuss the minimum pulse sensitivity of our observations and present VERITAS observations of CALIOP: a space-based pulsed laser on board the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations. The detection of these pulses with VERITAS, using the analysis techniques developed for our technosignature search, allows a test of our analysis efficiency and serves as an important proof of principle.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovery of a Second Millesecond Accreting Pulsar: XTE J1751-305

We report the discovery by the RXTE PCA of a second transient accreting millisecond pulsar, XTE J1751-305, during regular monitoring observations of the galactic bulge region. The pulsar has a spin frequency of 435 Hz, making it one of the fastest pulsars. The pulsations contain the signature of orbital Doppler modulation, which implies an orbital period of 42 minutes, the shortest orbital period of any known radio or X-ray millisecond pulsar. The mass function, f(sub x) = (1.278 +/- 0.003) x 10 (exp -6) solar mass, yields a minimum mass for the companion of between 0.013 and 0.0017 solar mass depending on the mass of the neutron star. No eclipses were detected. A previous X-ray outburst in June, 1998, was discovered in archival All-Sky Monitor data. Assuming mass transfer in this binary system is driven by gravitational radiation, we constrain the orbital inclination to be in the range 30 deg-85 deg and the companion mass to be 0.013-0.035 solar mass. The companion is most likely a heated helium dwarf. We also present results from the Chandra HRC-S observations which provide the best known position of XTE J1751-305.

Markwardt, C. B.↗

Smart Power Supply for Battery-Powered Systems

A power supply for battery-powered systems has been designed with an embedded controller that is capable of monitoring and maintaining batteries, charging hardware, while maintaining output power. The power supply is primarily designed for rovers and other remote science and engineering vehicles, but it can be used in any battery alone, or battery and charging source applications. The supply can function autonomously, or can be connected to a host processor through a serial communications link. It can be programmed a priori or on the fly to return current and voltage readings to a host. It has two output power busses: a constant 24-V direct current nominal bus, and a programmable bus for output from approximately 24 up to approximately 50 V. The programmable bus voltage level, and its output power limit, can be changed on the fly as well. The power supply also offers options to reduce the programmable bus to 24 V when the set power limit is reached, limiting output power in the case of a system fault detected in the system. The smart power supply is based on an embedded 8051-type single-chip microcontroller. This choice was made in that a credible progression to flight (radiation hard, high reliability) can be assumed as many 8051 processors or gate arrays capable of accepting 8051-type core presently exist and will continue to do so for some time. To solve the problem of centralized control, this innovation moves an embedded microcontroller to the power supply and assigns it the task of overseeing the operation and charging of the power supply assets. This embedded processor is connected to the application central processor via a serial data link such that the central processor can request updates of various parameters within the supply, such as battery current, bus voltage, remaining power in battery estimations, etc. This supply has a direct connection to the battery bus for common (quiescent) power application. Because components from multiple vendors may have differing power needs, this supply also has a secondary power bus, which can be programmed a priori or on-the-fly to boost the primary battery voltage level from 24 to 50 V to accommodate various loads as they are brought on line. Through voltage and current monitoring, the device can also shield the charging source from overloads, keep it within safe operating modes, and can meter available power to the application and maintain safe operations.

Krasowski, Michael J.↗

Preliminary results from the first satellite of a high-resolution germanium gamma-ray spectrometer: Description of instrument, some activation lines encountered, and studies of the diffuse spectra

Gamma radiation from terrestrial and extraterrestrial sources were investigated with a high resolution Ge(Li) spectrometer-cryogen system flown onboard a low altitude, spin stabilized, polar orbiting satellite. A brief description is given of the instrument and preliminary results obtained from earth orbit are discussed. Attempts were made to use angular distributions and geomagnetic latitude spectral variations to determine diffuse background spectrum, detect gamma ray line emissions from solar flares, and search for positron annihilation radiation coming from the direction of the galactic center.

Nakano, G. H.↗

Spaceflight Autonomous Multigenerational Microbial Sequencer in Support of Plant-Growth Systems

The CubeSat platform has proven successful in obtaining meaningful life science information when biological payloads are incorporated. Examples include: 1) the first-ever CubeSat with a biological payload, GeneSat-1, which demonstrated decreased growth rates for flight samples of Escherichia coli in low Earth orbit (Parra et al. 2008); 2) PharmaSat, demonstrated that Saccharomyces cerevisiae in the microgravity environment exhibits a significant level of metabolic activity even at high doses of applied antifungal (Ricco et al. 2011); 3) O/OREOS, which used Bacillus subtilis(bacteria) to demonstrate for the first time that microorganisms can be loaded in a dried, dormant form and then rehydrated and grown in orbit months after launch (Nicholson et al. 2011; Ehrenfreund et al. 2014; 4) the SporeSat payload, which investigated Ceratopteris richardii(fern spores) using lab-on-a-chip devices (BioCDs) and minicentrifuges to produce artificial gravitational forces in ground studies (Park et al. 2017), with demonstration of the BioCD and minicentrifuge in space; 5) EcAMSat, the first CubeSat to be directly deployed from the ISS for an experiment assessing antibiotic resistance of E. coli in the microgravity environment (Padgen et al. 2020); 6) BioSentinel, exposed a culture of yeast to galactic cosmic radiation (GCR) and solar particle events while in heliocentric orbit to measure the rate of double-strand-break repair using DNA-repair-deficient mutants. This effort measures the metabolic parameters of yeast in a deep-space environment compared to Earth ambient conditions using a 3-color LED detection system (Ricco et al. 2020; Padgen et al. 2021). We aim to expand this list to include a Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS). SAMMS will allow for the genome level understanding of changes in growth and metabolic activity for any organism. While microbes are suitable for early studies in our proposed platform because of their small size, small and relatively less-complicated genomes, fast generation times, and relevance to life support systems; multicellular organisms can similarly be evaluated for their genetic response to the spaceflight environment. The Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS) will enable autonomous sequencing of biological samples in plant production units, cislunar orbit and on the lunar surface to examine spaceflight effects (ie. radiation, altered gravity, reduced pressures) on plant and microbial genomes.On this team a Kennedy Space Center (KSC) space crop production and water systems microbiologist/molecular biologist works with a Johnson Space Center (JSC) International Space Station (ISS) microbial sequencing expert and an Ames Research Center (ARC) CubeSat Engineering team to convert an automated Oxford Nanopore librarypreparation and sequencing method to a fluidic CubeSat payload system. The Oxford Nanopore MinION sequencing platform has proven successful in the spaceflight environment onboard the ISS (Stahl-Rommel et al. 2021). Further long-duration spaceflight and exposure to high levels of radiation will cause genotypic effects in biological organisms that may affect their function. Monitoring the adaption of a population to the spaceflight environment and any subsequent beneficial mutations will allow for the harnessing of organisms best suited for use in life support systems. This will ensure that the selected life support-essential microorganisms maintain their intended specified function over generations of culturing in the relevant spaceflight environment without becoming hazardous to crew or spacecraft systems.

Aubrie E Orourke↗

Real-Time Optical Flux Limits from Gamma-Ray Bursts Measured by the Gamma-Ray Optical Counterpart Search Experiment

The Gamma-Ray Optical Counterpart Search Experiment presents new experimental upper limits on the optical flux from gamma-ray bursts (GRBs). Our experiment consisted of a fully automated very wide-field opto-electronic detection system that imaged locations of GRBs within a few seconds of receiving trigger signals provided by BATSE's real-time burst coordinate distribution network. The experiment acquired 3800 observing hours, recording 22 gamma-ray burst triggers within approx. 30 s of the start of the burst event. Some of these bursts were imaged while gamma-ray radiation was being detected by BATSE. We identified no optical counterparts associated with gamma-ray bursts among these events at the mV approx. 7.0-8.3 sensitivity level. We find the ratio of the upper limit to the V-band optical flux, F nu, to the gamma-ray fluence, Phi gamma, from these data to be 1 x 10(exp-18) less than F nu Phi gamma less than 2 x 10(exp -16).

Park, H. S.↗

Broadband optical modulation and control at millikelvin temperatures

A universal experimental challenge in studying radiation effects on cryogenic devices is precisely and accurately characterizing the position-dependent device response near the energy detection threshold. Here, we have developed a compact cryogenic optical beam steering system that can be used to generate O (μs) pulses of small numbers of photons over the energy range of 1.3–3.4 eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including superconducting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-Testing Computer Memory

Memory system for computer repeatedly tests itself during brief, regular interruptions of normal processing of data. Detects and corrects transient faults as single-event upsets (changes in bits due to ionizing radiation) within milliseconds after occuring. Self-testing concept surpasses conventional by actively flushing latent defects out of memory and attempting to correct before accumulating beyond capacity for self-correction or detection. Cost of improvement modest increase in complexity of circuitry and operating time.