Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulsing frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Pulsed RF schemes for tearing mode stabilization

The RF stabilization of tearing modes with current condensation has the potential to increase stabilization efficiency and loosen power localization requirements. Such benefits stem from the cooperative feedback between the RF deposition and resulting island temperature perturbation governed by diffusion. A self consistent treatment of the damping of an rf ray as it traverses the island shows that low damping scenarios can require unfavorably high powers to overcome initial power leakage and effectively capitalize on the nonlinear effect. In this work it is demonstrated that for such regimes,modulated stabilization schemes can achieve significant improvements in heating and current drive contributions to stabilization for the same average power as a continuous wave scheme. The impact of modulation frequency and duty cycle on the performance is explored, the results of which suggest modulation strategies in which the pulsing periods are kept on the order of a diffusive time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer

Radio frequency (RF) magnetometers based on nitrogen vacancy centers in diamond are predicted to offer femtotesla sensitivity, but previous experiments were limited to the picotesla level. We demonstrate a femtotesla RF magnetometer using a diamond membrane inserted between ferrite flux concentrators. The device provides ~300-fold amplitude enhancement for RF magnetic fields from 70 kHz to 3.6 MHz, and the sensitivity reaches ~70 fT√s at 0.35 MHz. The sensor detected the 3.6-MHz nuclear quadrupole resonance (NQR) of room-temperature sodium nitrite powder. The sensor’s recovery time after an RF pulse is ~35 μs, limited by the excitation coil’s ring-down time. The sodium-nitrite NQR frequency shifts with temperature as -1.00±0.02 kHz/K, the magnetization dephasing time is T 2 *=887±51 μs, and multipulse sequences extend the signal lifetime to 332±23 ms, all consistent with coil-based studies. Our results expand the sensitivity frontier of diamond magnetometers to the femtotesla range, with potential applications in security, medical imaging, and materials science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient excitation and control of integrated photonic circuits with virtual critical coupling

Critical coupling in integrated photonic devices enables the efficient transfer of energy from a waveguide to a resonator, a key operation for many applications. This condition is achieved when the resonator loss rate is equal to the coupling rate to the bus waveguide. Carefully matching these quantities is challenging in practice, due to variations in the resonator properties resulting from fabrication and external conditions. Here, we demonstrate that efficient energy transfer to a non-critically coupled resonator can be achieved by tailoring the excitation signal in time. We rely on excitations oscillating at complex frequencies to load an otherwise overcoupled resonator, demonstrating that a virtual critical coupling condition is achieved if the imaginary part of the complex frequency equals the mismatch between loss and coupling rate. We probe a microring resonator with tailored pulses and observe a minimum intensity transmission T = 0.11 in contrast to a continuous-wave transmission T = 0.58, corresponding to 8 times enhancement of intracavity intensity. Our technique opens opportunities for enhancing and controlling on-demand light-matter interactions for linear and nonlinear photonic platforms.

42 ENGINEERING↗

Demonstrating the Potential of Adaptive LMS Filtering on FPGA-Based Qubit Control Platforms for Improved Qubit Readout in 2D and 3D Quantum Processing Units

Advancements in quantum computing underscore the critical need for sophisticated qubit readout techniques to accurately discern quantum states. This abstract presents our research intended for optimizing readout pulse fidelity for 2D and 3D Quantum Processing Units (QPUs), the latter coupled with Superconducting Radio Frequency (SRF) cavities. Focusing specifically on the application of the Least Mean Squares (LMS) adaptive filtering algorithm, we explore its integration into the FPGA-based control systems to enhance the accuracy and efficiency of qubit state detection by improving Signal-to-Noise Ratio (SNR). Implementing the LMS algorithm on the Zynq UltraScale+ RFSoC Gen 3 devices (RFSoC 4x2 FPGA and ZCU216 FPGA) using the Quantum Instrumentation Control Kit (QICK) open-source platform, we aim to dynamically test and adjust the filtering parameters in real-time to characterize and adapt to the noise profile presented in quantum computing readout signals. Our preliminary results demonstrate the LMS filter's capability to maintain high readout accuracy while efficiently managing FPGA resources. These findings are expected to contribute to developing more reliable and scalable quantum computing architectures, highlighting the pivotal role of adaptive signal processing in quantum technology advancements.

Johnson, Hans↗

Demonstrating the Potential of Adaptive LMS Filtering on FPGA-Based Qubit Control Platforms for Improved Qubit Readout in 2D and 3D Quantum Processing Units

Advancements in quantum computing underscore the critical need for sophisticated qubit readout techniques to accurately discern quantum states. This abstract presents our research intended for optimizing readout pulse fidelity for 2D and 3D Quantum Processing Units (QPUs), the latter coupled with Superconducting Radio Frequency (SRF) cavities. Focusing specifically on the application of the Least Mean Squares (LMS) adaptive filtering algorithm, we explore its integration into the FPGA-based control systems to enhance the accuracy and efficiency of qubit state detection by improving Signal-to-Noise Ratio (SNR). Implementing the LMS algorithm on the Zynq UltraScale+ RFSoC Gen 3 devices (RFSoC 4x2 FPGA and ZCU216 FPGA) using the Quantum Instrumentation Control Kit (QICK) open-source platform, we aim to dynamically test and adjust the filtering parameters in real-time to characterize and adapt to the noise profile presented in quantum computing readout signals. Our preliminary results demonstrate the LMS filter's capability to maintain high readout accuracy while efficiently managing FPGA resources. These findings are expected to contribute to developing more reliable and scalable quantum computing architectures, highlighting the pivotal role of adaptive signal processing in quantum technology advancements.

Johnson, Hans↗

Analysis and Control of a Three-Port Converter with High-Frequency AC Link for Hybrid Unmanned/Autonomous Aerial Vehicles

In this study, a three-port resonant converter with a high-frequency isolation link for hybrid unmanned/autonomous aerial vehicle (UAV/AAV) applications is analyzed. The rectified engine-generator set output supplies the first input ports while the other is connected to a battery energy storage system. Input ports consist of half-bridge high-frequency inverters, whereas output port utilizes a semi-bridgeless active rectifier. This rectifier is formed by replacing rectifier low-side diodes with active switching devices. A phase-shift duty-cycle control is implemented for switching signals to regulate the power share and flow between ports. The proposed control system implemented achieves zero voltage switching (ZVS), reduces switching losses, and minimum current flow optimization ensures regulation in a wide range of output power. Compared to the existing bidirectional pulse width modulation (PWM) converters, the proposed system decreases the number of power conversion stages and provides centralized control without needing communications between the ports. The proposed control technique operating in closed-loop control achieves the power flow between ports under various load conditions. Finally, theoretical analysis demonstrates the proposed converter’s viability and laboratory experimental validations at 500 W full power.

33 ADVANCED PROPULSION SYSTEMS↗

Phase-sensitive γ-encoded recoupling of heteronuclear dipolar interactions and 1 H chemical shift anisotropy

γ-encoded recoupling sequences are known to produce strong amplitude modulations that lead to sharp doublets when Fourier transformed. These doublets depend very little on the recoupled tensor asymmetry and thus enable for the straightforward determination of dynamic order parameters. It can, however, be difficult to measure small anisotropies, or small order parameters, using such sequences; the resonances from the doublet may overlap with each other, or with the zero-frequency glitch. This limitation has prevented the widespread use of 1 H chemical shift anisotropy (CSA) for the measurement of dynamics, particularly for CH protons which typically have CSAs of only a few ppm when immobile. In this work, we introduce a simple modification to the traditional 1 H CSA and proton-detected local field pulse sequences that enables the acquisition of a hypercomplex dataset and the removal of the uncorrelated magnetization that results in the zero-frequency glitch. These new sequences then yield a frequency shift in the indirect dimension, rather than a splitting, which is easily identifiable even in cases of weak interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser pulse induced second- and third-harmonic generation of gold nanorods with real-time time-dependent density functional tight binding (RT-TDDFTB) method

In this paper, we investigate second- and third-harmonic generation processes in Au nanorod systems using the real-time time-dependent density functional tight binding method. Our study focuses on the computation of nonlinear signals based on the time dependent dipole response induced by linearly polarized laser pulses interacting with nanoparticles. We systematically explore the influence of various laser parameters, including pump intensity, duration, frequency, and polarization directions, on harmonic generation. We demonstrate all the results using Au nanorod dimer systems arranged in end-to-end configurations, and disrupting the spatial symmetry of regular single nanorod systems is crucial for second-harmonic generation processes. Furthermore, we study the impact of nanorod lengths, which lead to variable plasmon energies, on harmonic generation, and estimates of polarizabilities and hyper-polarizabilities are provided.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterizing particle-like charge-migration dynamics with high-order harmonic sideband spectroscopy

Here, we introduce high-order harmonic sideband spectroscopy and show that it can be a robust probe of charge migration (CM) in a halogenated carbon-chain molecule. We simulate both the CM and high-order harmonic generation (HHG) dynamics using ab initio time-dependent density-functional theory. We find that CM dynamics initiated along the molecular backbone induces sidebands in the HHG spectrum driven by a delayed laser pulse that is polarized perpendicular to the molecular axis. Monitoring the spectrum as either the HHG laser frequency or the relative delay is scanned allows for the extraction of detailed information about the time-domain characteristics of the CM process.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nonlinear dynamics and dissipation of a curvilinear vortex driven by a strong time-dependent Meissner current

Here, we report numerical simulations of large-amplitude oscillations of a trapped vortex line under a strong ac magnetic field $\textit{H(t) = H}$ sin$\textit{ωt}$ parallel to the surface. The power dissipated by an oscillating vortex segment driven by the surface ac Meissner currents was calculated by taking into account the nonlinear vortex line tension, vortex mass, and a nonlinear Larkin-Ovchinnikov (LO) viscous drag coefficient $\textit{η(v)}$. We show that the LO decrease of $\textit{η(v)}$ with the vortex velocity $\textit{v}$ can radically change the field dependence of the surface resistance R i ( H ) caused by trapped vortices. At low frequencies, $R_i(H)$ exhibits a conventional increase with $\textit{H}$, but as $\textit{ω}$ increases, the surface resistance becomes a nonmonotonic function of $\textit{H}$ which decreases with $\textit{H}$ at higher fields. The effects of frequency, pin spacing, and the mean-free path $l_i$ on the field dependence of $R_i(H)$ were calculated. It is shown that, as the surface gets dirtier and $l_i$ decreases, the anomalous drop of $R_i(H)$ with $\textit{H}$ shifts to lower fields which can be much smaller than the lower critical magnetic field. Our numerical simulations also show that the LO decrease of $\textit{η(v)}$ with $\textit{v}$ can cause a vortex bending instability at high field amplitudes and frequencies, giving rise to the formation of dynamic kinks along the vortex. Measurements of $R_i(H)$ caused by sparse vortices trapped perpendicular to the surface can offer opportunities to investigate an extreme nonlinear dynamics of vortices driven by strong current densities up to the depairing limit at low temperatures. The behavior of $R_i(H)$, which can be tuned by varying the rf frequency or concentration of nonmagnetic impurities, is not masked by strong heating effects characteristic of dc or pulse transport measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Short pulsewidth high repetition rate nanosecond transient absorption spectrometer

A high-sensitivity nanosecond to millisecond transient absorption spectrometer for measurements of miniscule signals under low excitation intensities includes an excitation source generating a >100 Hz, <5 ns pulsewidth excitation pulse for exciting a light absorbing sample, a probe light source for generating a high photon flux probe light beam producing an average irradiance greater than 1 μW m-2 nm-1 for measuring the transient absorption spectrum of the sample before and after excitation by the excitation source, a DC-coupled detector capable of measuring light for enabling synchronous measurement of both the transmission of the probe light beam and the change in transmission of the probe light beam between a signal with the excitation pulse present and a signal in the absence of the excitation pulse, and a digital oscilloscope with a trigger rearm time capable of collecting every trigger event at frequencies including 1MHz, for enabling sequential noise subtraction protocols.

Rimshaw, Adam↗

Output Capacitance Loss of GaN HEMTs in Steady-State Switching

The output capacitance (C OSS ) loss, a loss produced when the device’s output capacitor is charged and discharged, has become a concern for GaN high electron mobility transistors (HEMTs) in high-frequency applications. This work presents a new, easy-to-implement method for the C OSS loss characterization based on the unclamped inductive switching (UIS) setup. As compared to prior approaches, this method involves the device’s ON-state conduction and could measure the C OSS loss in a single pulse and the steady-state switching. The C OSS loss of three types of mainstream commercial GaN HEMTs is characterized, which exhibit some common dependencies including a non-monotonic relation with the dv/dt (or resonance frequency), a linear relation with the ON-state current, a power-law relation with the peak blocking voltage, and little temperature dependence. In addition, their C OSS losses all show minimal distinctions in a single pulse and the steady-state switching, despite the increased on-resistance in the steady-state switching. Furthermore, this suggests that the traps accounting for the C OSS loss possess different de-trapping time constants as compared to the traps governing the dynamic on-resistance. Finally, a unified model is established to describe the C OSS loss of all three types of GaN HEMTs. These results provide important references for the high-frequency application of GaN HEMTs and new insights into the physical origin of their C OSS loss.1

42 ENGINEERING↗

Mid-infrared Pulsed Upconversion Imaging in a Rotating Detonation Combustor

To meet the challenges associated with performing mid-InfraRed (IR) imaging in Rotating Detonation Combustors (RDCs), a novel pulsed mid-IR UpConversion Imaging (UCI) diagnostic has been implemented. UCI is an alternative to direct mid-IR detection that uses nonlinear optical frequency mixing to shift mid-IR wavelengths carrying a target image to shorter wavelengths that can be imaged with high-performance silicon-based CCD/CMOS cameras. This approach offers several favorable properties including high spectral selectivity, high temporal resolution, and superior low-light detectivity. A hydrogen-air research RDC was operated with carbon dioxide addition to allow pulsed UCI imaging of mid-IR luminosity within the combustion channel from spontaneous thermal emissions. The resulting measurements demonstrate high spatiotemporal resolution capable of imaging small structures near the supersonically propagating detonation wave front. The results show how this technique can be used to observe sharp gradients and millimeter-scale structures in the high-temperature, high-pressure zones RDC flow fields.

White, Logan W.↗

Nanosecond Transient Validation of Surge Arrester Models to Predict Electromagnetic Pulse Response

The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. Further, this article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.

42 ENGINEERING↗

Resonant interaction between phonons and PbTe/PbSe (001) misfit dislocation networks

Here this work aims at a quantitative and mechanistic understanding of the dynamic process of the phonon-dislocation interaction in PbTe/PbSe (001) heterostructures using the Concurrent Atomistic-Continuum (CAC) method as the simulation tool. The misfit dislocation network and the atomic-scale dislocation core structure obtained in the simulations are found to agree reasonably well with the experimental observations of the PbTe/PbSe (001) interface. Through visualizing the dynamic interaction between phonons and dislocations, as well as quantifying the dislocation vibration amplitude, the phonon energy transmission, and the thermal resistance of the misfit interfaces, this work has illustrated and quantified two mechanisms for phonon-dislocation interaction: (1) phonon scattering by the strain field of dislocations, and (2) phonon scattering by dislocations that vibrate via the local modes of a dislocation network; the latter, leads to resonant phonon-dislocation interaction, which is manifested as local maxima of out-of-phase vibration of the atoms on the two sides of the slip plane, leading to local minima of the energy transmission in the heterostructure that contains one interface. The local vibrational modes are found to be excited only by shear stress induced by transverse phonons. Among various resonant modes, the one with the lowest frequency has the strongest effect. This work has also demonstrated the collective motion of dislocations under ultrafast phonon pulses. In addition, the dynamic properties of the misfit dislocation network localized within one interface are found to be significantly altered by the presence of misfit dislocations at other interfaces, thus further confirming the cooperative dynamic nature of the motion of dislocations and phonons.

36 MATERIALS SCIENCE↗

Correction of Q Factor Effects for Simultaneous Collection of Elemental Analysis and Relaxation Times by Nuclear Magnetic Resonance

A new method for measurement of elemental analysis by nuclear magnetic resonance (NMR) of unknown samples is discussed in this report as a quick and robust means to measure elemental ratios without the use of internal or external calibration standards. The determination of elemental ratios was done by normalizing the signal intensities by the frequency dependent quality factor (Q) and the gyromagnetic ratios (γ) for each measured nucleus. The correction for the frequency dependence was found by characterizing the output signal of the probe as a function of the quality factor (Q) and the frequency, and the correction for γ was discussed in a previous study. A Carr–Purcell–Meiboom–Gill (CPMG) pulse sequence was used for evaluation of the relative signal intensities, which allows for derivation of elemental ratios, and was correspondingly used to simultaneously measure the T 2 * of samples for an added parameter for more accurate identification of unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗