Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Thermoelectric and morphological effects of Peltier pulsing on directional solidification of eutectic Bi-Mn

Extensive in situ thermal measurements using Peltier Interface Demarcation (PID) during directional solidification of eutectic Bi/MnBi were carried out. Observations indicate that significant thermal transients occur throughout the sample as a result of the Peltier pulsing. The contributions of the Peltier, Thomson, and Joule heats were separated and studied as a function of pulse intensity and polarity. The Joule and the combined Peltier and Thomson thermal contributions were determined as a function of time during and after the current pulses, close to the solid/liquid interface. Variations of the Bi/MnBi particle morphology clearly reveal the interface shape, changes in interface velocity, meltback, and temporary loss of cooperative growth, as a result of the pulsing.

Silberstein, R. P.↗

Analyses of the gamma-ray pulse-height spectra from the lunar surface

The method of inferring photon spectra from an analysis of the measured pulse-height spectrum is considered along with the spectrum shape and its variation energy. The case is examined where photoelastic absorption predominates, and Compton scattering and pair production are negligible. The analytic method for obtaining the elemental composition from the observed lunar surface spectrum is described, and theoretical and calculated weight fraction fluxes for average lunar composition are tabulated.

Trombka, J. I.↗

Reducing Conservatism of Analytic Transient Response Bounds via Shaping Filters

Recent results show that the peak transient response of a linear system to bounded energy inputs can be computed using the energy-to-peak gain of the system. However, analytically computed peak response bound can be conservative for a class of class bounded energy signals, specifically pulse trains generated from jet firings encountered in space vehicles. In this paper, shaping filters are proposed as a Methodology to reduce the conservatism of peak response analytic bounds. This Methodology was applied to a realistic Space Station assembly operation subject to jet firings. The results indicate that shaping filters indeed reduce the predicted peak response bounds.

Kwan, Aiyueh↗

Infrared focal plane performance in the South Atlantic anomaly

Proton-induced pulse height distributions (PHD's) in Si:XX detectors were studied analytically and experimentally. In addition, a preliminary design for a flight experiment to characterize the response of Si:XX detectors to the trapped proton environment and verify PHD models was developed. PHD's were computed for two orbit altitudes for a variety of shielding configurations. Most of the proton-induced pulses have amplitudes less that about 3.5 x 10(exp 5) e-h pairs. Shielding has a small effect on the shape of the PHD's. The primary effect of shielding is to reduce the total number of pulses produced. Proton-induced PHD's in a Si:Sb focal plane array bombarded by a unidirectional 67-MeV beam were measured. The maximum pulse height recorded was 6 x 10(exp 5) pairs. The distribution had two peaks: the larger peak corresponded to 3.8 x 10(exp 5) pairs and the smaller peak to 1.2 x 10(exp 5) pairs. The maximum pulse height and the larger peak are within a factor of two of predicted values. The low-energy peak was not expected, but is believed to be an artifact of inefficient charge collection in the detector. The planned flight experiment will be conducted on a Space Shuttle flight. Lockheed's helium extended life dewar (HELD) will be used to provide the required cryogenic environment for the detector. Two bulk Si:Sb arrays and two Si:As impurity band conduction arrays will be tested. The tests will be conducted while the Space Shuttle passes through the South Atlantic Anomaly. PHD's will be recorded and responsivity changes tracked. This experiment will provide a new database on proton-induced PHD's, compare two infrared detector technologies in a space environment, and provide the data necessary to validate PHD modeling.

Junga, Frank A.↗

The SUrvey for Pulsars and Extragalactic Radio Bursts - IV. Discovery and polarimetry of a 12.1-s radio pulsar

We report the discovery of PSR J2251−3711, a radio pulsar with a spin period of 12.1 s, the second longest currently known. Its timing parameters imply a characteristic age of 15 Myr, a surface magnetic field of 1.3 × 10^(13) G, and a spin-down luminosity of 2.9 × 10^(29) erg/s. Its dispersion measure of 12.12(1) pc/cu. cm leads to distance estimates of 0.5 and 1.3 kpc according to the NE2001 and YMW16 Galactic free electron density models, respectively. Some of its single pulses show an uninterrupted 180-deg sweep of the phase-resolved polarization position angle, with an S-shape reminiscent of the rotating vector model prediction. However, the fact that this sweep occurs at different phases from one pulse to another is remarkable and without straightforward explanation. Although PSR J2251−3711 lies in the region of the P − P˙ parameter space occupied by the X-ray isolated neutron stars (XINS), there is no evidence for an X-ray counterpart in our Swift XRT observation; this places a 99 per cent-confidence upper bound on its unabsorbed bolometric thermal luminosity of 1.1 × 10^(31) (d/1 kpc)^2 erg/s for an assumed temperature of 85 eV, where d is the distance to the pulsar. Further observations are needed to determine whether it is a rotation-powered pulsar with a true age of at least several Myr, or a much younger object such as an XINS or a recently cooled magnetar. Extreme specimens like PSR J2251−3711 help bridge populations in the so-called neutron star zoo in an attempt to understand their origins and evolution.

V Morello↗

Two-photon excitation of nitric oxide fluorescence as a temperature indicator in unsteady gasdynamic processes

A laser-induced fluorescence technique based on the pulsed two-photon excitation of NO is presented which is especially suited for the measurement of fluctuating temperatures in cold turbulent flows. The technique uses the fluorescence from the UV gamma bands of NO produced by two-photon excitation of NO (A 2 Sigma +, nu-prime = 0 - X 2 Pi, nu-double prime = 0) to obtain a rotational temperature. An analysis is presented of relevant aspects of the two-photon absorption process including microphysical processes, spectral intensities as a function of transition and laser spectral widths, line-shape integrals, the nonequilibrium response of the medium to a laser pulse, fluorescence energies, signal to noise ratio, and focusing effects. An analysis of absolute two-photon absorptivity measured in a nonflowing cell is then presented and used to predict signal to noise ratios greater than 50 for supersonic flows at temperatures below 300 K.

Mckenzie, R. L.↗

The electric fields produced by lightning stepped leaders

The electric fields produced by stepped and dart-stepped leaders which immediately precede return strokes in lightning discharges to the ground have been recorded in Florida and Arizona. The mean interval time between normal steps is about 16 microsec, and the mean interval between dart steps is 6-8 microsec. The amplitudes of leader pulses in Florida increase just prior to the return stroke, the largest usually being about 10% of the return-stroke peak. In Arizona the leader pulse amplitudes are smaller than those in Florida, in relation to the return stroke, and are not as easy to identify. The shapes of the fields produced by normal steps are similar to dart steps, and the dart steps are very similar to regular sequences of pulses produced by many intracloud discharges. The 10-90% rise times of individual step wave forms are often less than 0.3 microsec, and the full width at half maximum of a step pulse is typically 0.4-0.5 microsec under conditions where the propagation distortion is minimal. The amplitudes and the shapes of leader step wave forms suggest that the peak step current is at least 2000-8000 A close to the ground and that the maximum rate of change of step current is 6-24 kA/microsec or larger. A rough estimate of the minimum charge lowered during the formation of a step is 0.001 to 0.004 C.

Krider, E. P.↗

Wide range multi-channel analog switch

A ten-channel analog switch has been developed as a sample and shape circuit for signals used as inputs to a logarithmic pulse height recording system. The circuit employs a field effect transistor as the switching element. Switching transients are reduced to approximately 2 mV by adding to the gated signal an inverted transient generated by an identical circuit with no signal applied. The circuit is linear to 2% from 3 mV to 10 V.

Levit, L. B.↗

Hybrid ECG signal conditioner

Circuit with high common-mode rejection has ability to filter and amplify accepted analog electrocardiogram (ECG) signals of varying amplitude, shape, and polarity. In addition, low power circuit develops standardized pulses that can be counted and averaged by heart/breath rate processor.

Rinard, G. A.↗

ac bidirectional motor controller

Test data are presented and the design of a high-efficiency motor/generator controller at NASA-Lewis for use with the Space Station power system testbed is described. The bidirectional motor driver is a 20 kHz to variable frequency three-phase ac converter that operates from the high-frequency ac bus being designed for the Space Station. A zero-voltage-switching pulse-density-modulation technique is used in the converter to shape the low-frequency output waveform.

Schreiner, K.↗

Pulsed Flows Along a Cusp Structure Observed with SOO/AIA

We present observations of a cusp-shaped structure that formed after a flare and coronal mass ejection on 14 February 2011. Throughout the evolution of the cusp structure, blob features up to a few Mm in size were observed flowing along the legs and stalk of the cusp at projected speeds ranging from 50 to 150 km/sec. Around two dozen blob features, on order of 1 - 3 minutes apart, were tracked in multiple AlA EUV wavelengths. The blobs flowed outward (away from the Sun) along the cusp stalk, and most of the observed speeds were either constant or decelerating. We attempt to reconstruct the 3-D magnetic field of the evolving structure, discuss the possible drivers of the flows (including pulsed reconnect ion and tearing mode instability), and compare the observations to studies of pulsed reconnect ion and blob flows in the solar wind and the Earth's magnetosphere.

Thompson, Barbara↗

Surface temperature of a magnetized neutron star and interpretation of the ROSAT data. 1: Dipole fields

We model the temperature distribution at the surface of a magnetized neutron star and study the effects on the observed X-ray spectra and light curves. Generalrelativistic effects, i.e., redshift and lensing, are fully taken into account. Atmospheric effects on the emitted spectral flux are not included: we consider only blackbody emission at the local effective temperature. In this first paper we restrict ourselves to dipole fields. General features are studied and compared with the ROSAT data from the pulsars 0833 - 45 (Vela), 0656 + 14, 0630 + 178 (Geminga), and 1055 - 52, the four cases for which there is strong evidence that thermal radiation from the stellar surface is detected. The composite spectra we obtain are not very different from a blackbody spectrum at the star's effective temperature. We conclude that, as far as blackbody spectra are considered, temperature estimates using single-temperature models give results practically identical to our composite models. The change of the (composite blackbody) spectrum with the star's rotational phase is also not very large and may be unobservable inmost cases. Gravitational lensing strongly suppresses the light curve pulsations. If a dipole field is assumed, pulsed fractions comparable to the observed ones can be obtained only with stellar radii larger than those which are predicted by current models of neutron star struture, or with low stellar masses. Moreover, the shapes of the theoretical light curves with dipole fields do not correspond to the observations. The use of magnetic spectra may raise the pulsed fraction sufficiently but will certainly make the discrepancy with the light curve shapes worse: dipole fields are not sufficient to interpret the data. Many neutron star models with a meson condensate or hypersons predict very small radii, and hence very strong lensing, which will require highly nondipolar fields to be able to reproduce the observed pulsed fractions, if possible at all: this may be a new tool to constrain the size of neutron stars. The pulsed fractions obtained in all our models increase with photon energy: the strong decrease observed in Geminga at energies 0.3-0.5 keV is definitely a genuine effect of the magnetic field on the spectrum in contradistinction to the magnetic effects on the surface temperature considered her. Thus, a detailed analysis of thermal emission from the four pulsars we consider will require both complex surface field configurations and the inclusion of magnetic effects in the atmosphere (i.e., on the emitted spectrum).

Page, Dany↗

Pulsed Lidar Measurements of Atmospheric CO2 Column Absorption in the ASCENDS 2011 Airborne Campaign

We have previously demonstrated an efficient pulsed, wavelength-resolved IPDA lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS mission. Our team participated in the 2010 ASCENDS airborne campaigns we flew airborne version of the CO2 and O2 lidar on the NASA DC-8. The CO2 lidar measures the atmospheric backscatter profiles and shape of the 1572.33 nm absorption line using 250 mW average laser power, 30 wavelength samples per scan and 300 scans per second. Most flights had 5-6 altitude steps to greater than 12 km, and clear CO2 line shapes were observed at all altitudes. Our post-flight analysis estimated the Iidar range and pulse energies at each wavelength every second. We then solved for the best-fit CO2 absorption line shape, and calculated the Differential Optical Depth (DOD) at the line peak. We compared these to CO2 DODs calculated from spectroscopy based on HITRAN 2008 and the conditions from airborne in-situ readings. Analysis of the 2010 measurements over the Pacific Ocean and Lamont OK shows the expected -linear change of the peak DOD with altitude. For measurements at altitudes greater than 6 km the random errors were approximately 0.3 ppm for 80 sec averaging times. After the 2010 flights we improved the airborne lidar's scan uniformity, calibration and receiver sensitivity. Our team participated in the seven ASCENDS science flights during late July and August 2011. These flights were made over a wide variety of surface and cloud conditions near the US, including over the central valley of California, over several mountain ranges, over both broken and solid stratus cloud deck over the Pacific Ocean, snow patches on mountain tops, over thin and broken clouds above the US Southwest and Iowa, and over forests near the WLEF tower in Wisconsin. Analyses show the retrievals of lidar range and CO2 column absorption, as wen as estimates of CO2 mixing ratio worked well when measuring over topography with rapidly changing height and reflectivity, through thin clouds and to stratus cloud tops. For regions where the CO2 concentration was relatively constant, the measured CO2 absorption profile (averaged for 50 sec) matched the predicted profile to better than 1% RMS error for all flight altitudes. For 1 & 10 second averaging, the scatter in the retrievals was limited by signal shot noise (i.e. the sigual photon count). Analysis to date shows the decrease in CO2 due to vegetation when flying easterward over the Great Plains as well as the increase in CO2 concentration in the vicinity ofthe coal-fired power plant in New Mexico. Examples of these and other results will be presented.

Abshire, James B.↗

Time dependent temperature distribution in pulsed Ti:sapphire lasers

An expression is derived for the time dependent temperature distribution in a finite solid state laser rod for an end-pumped beam of arbitrary shape. The specific case of end pumping by circular (constant) or Gaussian beam is described. The temperature profile for a single pump pulse and for repetitive pulse operation is discussed. The particular case of the temperature distribution in a pulsed titanium:sapphire rod is considered.

Buoncristiani, A. Martin↗

Accuracy for detection of simulated lesions: comparison of fluid-attenuated inversion-recovery, proton density--weighted, and T2-weighted synthetic brain MR imaging

OBJECTIVE: The objective of our study was to determine the effects of MR sequence (fluid-attenuated inversion-recovery [FLAIR], proton density--weighted, and T2-weighted) and of lesion location on sensitivity and specificity of lesion detection. MATERIALS AND METHODS: We generated FLAIR, proton density-weighted, and T2-weighted brain images with 3-mm lesions using published parameters for acute multiple sclerosis plaques. Each image contained from zero to five lesions that were distributed among cortical-subcortical, periventricular, and deep white matter regions; on either side; and anterior or posterior in position. We presented images of 540 lesions, distributed among 2592 image regions, to six neuroradiologists. We constructed a contingency table for image regions with lesions and another for image regions without lesions (normal). Each table included the following: the reviewer's number (1--6); the MR sequence; the side, position, and region of the lesion; and the reviewer's response (lesion present or absent [normal]). We performed chi-square and log-linear analyses. RESULTS: The FLAIR sequence yielded the highest true-positive rates (p < 0.001) and the highest true-negative rates (p < 0.001). Regions also differed in reviewers' true-positive rates (p < 0.001) and true-negative rates (p = 0.002). The true-positive rate model generated by log-linear analysis contained an additional sequence-location interaction. The true-negative rate model generated by log-linear analysis confirmed these associations, but no higher order interactions were added. CONCLUSION: We developed software with which we can generate brain images of a wide range of pulse sequences and that allows us to specify the location, size, shape, and intrinsic characteristics of simulated lesions. We found that the use of FLAIR sequences increases detection accuracy for cortical-subcortical and periventricular lesions over that associated with proton density- and T2-weighted sequences.

NASA Discipline Neuroscience↗

Shuttle Laser Altimeter (SLA): A pathfinder for space-based laser altimetry and lidar

The Shuttle Laser Altimeter (SLA) is a Hitchhiker experiment now being integrated for first flight on STS-72 in November 1995. Four Shuttle flights of the SLA are planned at a rate of about a flight every 18 months. They are aimed at the transition of the Goddard Space Flight Center airborne laser altimeter and lidar technology to low Earth orbit as a pathfinder for operational space-based laser remote sensing devices. Future alser altimeter sensors such as the Geoscience Laser Altimeter System (GLAS), an Earth Observing System facility instrument, and the Multi-Beam Laser Altimeter (MBLA), the land and vegetation laser altimeter for the NASA TOPSAT (Topography Satellite) Mission, will utilize systems and approaches being tested with SLA. The SLA Instrument measures the distance from the Space Shuttle to the Earth's surface by timing the two-way propagation of short (approximately 10 na noseconds) laser pulses. laser pulses at 1064 nm wavelength are generated in a laser transmitter and are detected by a telescope equipped with a silicon avalanche photodiode detector. The SLA data system makes the pulse time interval measurement to a precision of about 10 nsec and also records the temporal shape of the laser echo from the Earth's surface for interpretation of surface height distribution within the 100 m diam. sensor footprint. For example, tree height can be determined by measuring the characteristic double-pulse signature that results from a separation in time of laser backscatter from tree canopies and the underlying ground. This is accomplished with a pulse waveform digitizer that samples the detector output with an adjustable resolution of 2 nanoseconds or wider intervals in a 100 sample window centered on the return pulse echo. The digitizer makes the SLA into a high resolution surface lidar sensor. It can also be used for cloud and atmospheric aerosol lidar measurements by lengthening the sampling window and degrading the waveform resolution. Detailed test objectives for the STS-72 mission center on the acquisition of sample data sets for land topography and vegetation height, waveform digitizer performance, and verification of data acquisition algorithms. The operational concept of SLA is illustrated in Fig. 1 where a series of 100 m footprints stretch in a profile of Earth surface topography along the nadir track of the Space Shuttle. The location of SLA as a dual canister payload on the Hitchhiker Bridge Assembly in Bay 12 of the Space Shuttle Endeavor can also be noted in this figure. Full interpretation of the SLA range measurement data set requires a 1 m knowledge of the Orbiter trajectory and better than 0.1 deg knowledge of Orbiter pointing angle. These ancillary data sets will be acquired during the STS-72 mission with an on-board Global Positioning System (GPS) receiver, K-band range and range-rate tracking of the Orbiter through TDRSS, and use of on-board inertial measurement units and star trackers. Integration and interpretation of all these different data sets as a pathfinder investigation for accurate determination of Earth surface elevation is the overall science of the SLA investigation.

Bufton, Jack↗

Pulsar magnetospheres, braking index, polar caps, and period-pulse-width distribution.

An investigation is conducted concerning the trapping of gas and its effect on the structure of the magnetic field. The aligned and orthogonal cases are discussed in detail. In each case, there are small collection zones which are both microscopically and macroscopically stable. By determining where macroscopic stability changes to instability, the separatrix between closed and open field lines is investigated together with the sizes and shapes of the polar caps. This information makes it possible to reexamine the period-pulse-width distribution and to compare it with observational data.

Roberts, D. H.↗

TPSAS-NF1676L-35311-DND

Objectives: - Inspect and identify the normal and abnormal cells, tissues, and biofluids (e.g., urine, serum, etc.) using a 532 nm pulsed laser within target distances of several centimeters (6 to 20 cm) and a line shaped laser spot-size 10 µm width by 5 mm height that would be suitable for astronauts’ health monitoring in space. Goals: - The goals of this research study are: - Solve some of the limitations of traditional micro-Raman systems (e.g., requires dark condition, sample collection, and slow) - build an instrument with pulsed-time gated Raman technology, operates in daylight, doesn’t require sample collection, and faster detection - Reduce the size and weight of the instrument - eliminate a high power laser and a large collection optics/telescope with a short working distance of several centimeters.

Nurul Abedin↗