Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Impact of Detailed Parameter Modeling of Open-Cycle Gas Turbines on Production Cost Simulation: Preprint

Flexible resources are increasingly important as variable renewable energy deployment in the power system increases. Although many systems are transitioning away from fossil fuels, open-cycle gas turbines are likely to play an important balancing role for some time, thus requiring accurate modeling of their operational parameters. This paper explores the impact of detailed representation of three operational parameters - start- up costs, run-up rates, and forced outage rates - in the production cost model of a system as it adopts higher levels of wind and solar. Using PLEXOS simulations of the NREL-118 bus test system, the study examines how more detailed parameter modeling affects outcomes such as the number of start-ups and shutdowns, ramping and total generation costs for open-cycle gas turbines, as renewable energy levels increase. The results suggest the value of detailed parameter modeling and continued research on combustion turbines' ability to provide flexibility.

economic dispatch↗

EMT and Phasor-Domain Co-simulation of a Low Frequency AC Transmission System for Offshore Wind Integration

This work investigates system level interactions of multi-terminal low frequency high-voltage alternating current (LF-HVac) system using back-to back converters and grid-level 60 Hz system. A co-simulation framework by integrating high- fidelity dynamic model of multi-terminal LF-HVac system in electromagnetic transient (EMT) simulation platform and phasor model of IEEE 39 bus system in transient-stability (phasor) program. The co-simulation framework for multi-terminal LF- HVac system with offshore wind integrated in a bulk power system is developed successfully and its steady state and dynamic operation is demonstrated and compared with EMT simulation. The co-simulation results show accurate representation of the dynamic responses with reduced computation burden and time compared to EMT platform.

low-frequency transmission, co-simulation, electro↗

Assessment and Commissioning of Electrical Substation Grid Testbed with a Real-Time Simulator and Protective Relays/Power Meters in the Loop

Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible trouble-shooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

Piesciorovsky, Emilio↗

pyRMG: A framework for high-throughput, large-cell DFT calculations on supercomputers

Exascale computing delivers the raw power to simulate ever larger and more chemically realistic systems, but realizing this potential requires codes that can efficiently use thousands of processors. Our real-space multigrid (RMG) density functional theory (DFT) code’s grid-decomposition approach scales nearly linearly with the number of graphics processing units (GPUs), even for simulations exceeding thousands of atoms. This scalability makes RMG a compelling tool for high-throughput DFT studies of materials that would otherwise be bottlenecked in other codes (for example, by global fast Fourier transforms in plane-wave DFT). However, the limited workflow infrastructure for RMG has thus far constrained its adoption to a small user community. In this work, we present pyRMG, a Python package designed to streamline the setup and execution of RMG DFT calculations. Built on the pymatgen and ASE (Atomic Simulation Environment) computational materials science Python packages, pyRMG automates input generation and convergence checking, and it integrates with modern job schedulers (e.g., Flux) on leadership-class platforms such as Frontier and Perlmutter. Here, we demonstrate pyRMG for a high-throughput study of strain effects in 2D 2L-Bi 2 Se 3 /2L-NbSe 2 heterostructures, which offers chemical insights into this system and shows that RMG-based workflows can converge with limited user intervention.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coordinated Control of Natural and Sub-Synchronous Oscillations via HVDC Links in Great Britain Power System

Conventional power oscillation damping (POD) controllers have been designed to be effective in damping either inter-area low-frequency oscillations (LFO) or sub-synchronous oscillations (SSO). For those POD controls, model-based control design method has been widely implemented with wide-area feedback signals from phasor measurement units (PMU). However, the model accuracy of a large realistic power system can hardly be guaranteed, which will finally impact the POD damping performance. In this paper, a measurement-based method is proposed for POD design using High Voltage Direct Current links (HVDC) to realize the coordinated control of both LFO and SSO. For each type of oscillations, a band-pass filter is added to avoid the interactions between different modes. Case studies are carried out on the Great Britain 36-bus power system model with multiple HVDC links in DIgSILENT/PowerFactory. Simulation results demonstrate that the proposed PODs are effective in damping inter-area LFO and SSO simultaneously.

Zhao, Yi↗

Future Battery Material Demand Analysis Based on U.S. Department of Energy R&D Targets

The U.S. Department of Energy’s Vehicle Technologies Office (VTO) supports research, development, and deployment of efficient, sustainable transportation technologies that will improve energy efficiency and fuel economy, and enable America to use less petroleum. To accelerate the development and adoption of new technologies, VTO has developed specific targets for a wide range of powertrain components, including the energy storage system. In this study, we use Autonomie, Argonne National Laboratory’s (Argonne’s) vehicle system simulation tool to evaluate future energy storage requirements (power, energy, etc.) for different vehicle classes, powertrains, component technologies and timeframes. BatPac, Argonne’s tool dedicated to energy storage pack design and costs, is then used to quantify the materials required for each pack. Market penetrations are then used to estimate the overall material demand worldwide and in the United States, with or without recycling. The results demonstrate that the positive impact of VTO research and development will lead to significant reduction in material compared to business-as-usual due to new anode and cathode designs, along with acceleration in battery cell chemistry penetrations. In terms of material demands, it is observed that lithium demand reaches about 80,000 tons (by a factor of 42–45), nickel demand reaches about 500,000 tons (by a factor of 47–56), manganese demand reaches about 30,000–50,000 tons (by a factor of 20–34), and cobalt demand reaches about 30,000 tons (by a factor of 13–28) in the future by 2050. The individual material demand per unit energy, however, decreases significantly in the future due to advances in VTO research and development activities. The increase in battery material demands is mostly driven by increased electrified vehicle fleet penetration in the markets.

25 ENERGY STORAGE↗

NREL's Advanced Distribution Management System (ADMS) Test Bed

NREL's advanced distribution management system (ADMS) research helps utilities meet customer expectations of reliability, power quality, renewable energy use, data security, and resilience to natural disasters and other threats.

Advanced Research on Integrated Energy Systems↗

Simulation and power quality analysis of a Loose-Coupled bipolar DC microgrid in an office building

With distributed generation and battery storage technologies thriving in microgrids, the use of direct current (DC) microgrids in the building sector offers multiple advantages in energy efficiency and power quality compared with alternating current (AC) systems. This study developed a new concept of a loose-coupled bipolar DC building power system. In this work, the concept was used to design a real-world office building in Shenzhen, China. A power system model was developed to study the stability and control of the DC power system and to verify DC power quality. The design and modeling of the DC power control system is discussed in detail. The study developed a few common fault scenarios in DC building microgrids that were simulated in the MATLAB-Simulink environment to validate the design of a loose-coupled bipolar DC system. The results indicate that the proposed loose-coupled bipolar DC system schema, when implemented with proper control algorithms, can achieve good fault-tolerant performance with reliable power quality, even during disruptive system events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Speed Variation Based Power Regulation Concept for Dynamic Wireless Charging

On-road wireless charging of electric vehicles (EVs) in-motion could potentially reduce range anxiety or battery size with wide-spread deployment. The planning and implementation of such systems are greatly complicated due to their susceptibility to load variation inherent to traffic flow. Here, this paper proposes a method for derisking the potential for traffic slowdowns by compensating for reduced vehicle speed and investigates how implementation may affect system performance. A load modeling case study is presented at 200kW for a mile of high-speed roadway employing speed-based power regulation with results indicating average power usage and maximum car hosting capability can be reduced by 20% and increased by 30% respectively. An 85kHz power electronics model is developed based on designs and prototypes for an 11kW, 190m airgap static system and a 200kW dynamic wireless track. The simulation is validated in the 11kW experimental prototype and modified for 200kW operation to compare with simulated performance. Sensitivity studies are performed in MATLAB/Simulink to evaluate how parameters influence system performance and confirm the capability to reduce output power and maintain efficiency at 11 and 200kW. The static 11kW experimental system operates at 93.6% efficiency and multiple options exist to reduce power while maintaining efficiency greater than 90%. The capability to dynamically modify power output from WPT coils, in an experimentally validated simulation, enables techniques to significantly mitigate load variability due to reductions in vehicle speed.

42 ENGINEERING↗

Deep Reinforcement Learning Based Volt-VAR Optimization in Smart Distribution Systems

This paper develops a model-free volt-VAR optimization (VVO) algorithm via multi-agent deep reinforcement learning (DRL) in unbalanced distribution systems. This method is novel since we cast the VVO problem in distribution networks to an intelligent deep Q-network (DQN) framework, which avoids solving a specific optimization model directly when facing time-varying operating conditions in the systems. We consider statuses/ratios of switchable capacitors, voltage regulators, and smart inverters installed at distributed generators as the action variables of the agents. A delicately designed reward function guides these agents to interact with the distribution system, in the direction of reinforcing voltage regulation and power loss reduction simultaneously. The forward-backward sweep method for radial three-phase distribution systems provides accurate power flow results within a few iterations to the DRL environment. The proposed method realizes the dual goals for VVO. We test this algorithm on the unbalanced IEEE 13-bus and 123-bus systems. Numerical simulations validate the excellent performance of this method in voltage regulation and power loss reduction.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Advanced Power Electronics and Electric Machines

The advanced power electronics and electric machines (APEEM) research group at the National Renewable Energy Laboratory (NREL) has developed world-class experimental and modeling capabilities for designing and evaluating efficient and reliable power electronics and electric machines thermal management systems. They also design, fabricate and characterize advanced power electronics packaging, and are developing state-of-health monitoring techniques. These researchers deliver safe, reliable, high performing, power-dense components that allow seamless integration between renewable energy sources, electric transportation, and the grid, helping to make widespread electric vehicle (EV) adoption and greenhouse gas emissions reduction more feasible. This document outlines the group's major capabilities in the areas of power electronics; module development and characterization; thermal modeling and management; thermomechanical reliability analysis of devices, modules, inverters/converters, and electric machines; physics-of-failure-based reliability analysis; and microelectronics. It also overviews the group's state-of-the-art equipment for fluid-based thermal management; thermal measurement & characterization; thermomechanical reliability analysis; micro- and power electronics measurement & characterization; and prototype fabrication, as well as the group's world-class modeling and simulation capabilities.

advanced gate drivers↗

Database Management Module Framework for Dynamic Contingency Analysis and Visualization

The Dynamic Contingency Analysis Tool (DCAT) is being developed to mimic the response of generation dynamics, protection, and load components to extreme contingencies in power systems. Currently, DCAT generates a huge data set, with the analysis results stored in multiple subfolders using a great many files in different formats (power flow cases, time series, figures, spreadsheets). To help power system engineers thoroughly understand and analyze system behavior under many scenarios and contingencies, we developed a database management module (DBM) that enables future integration of DCAT with industry-grade Big Data analytical and interactive visualization platforms. In this paper, we demonstrate the DBM framework with interactive analytics and visualization for DCAT on the synthetic South Carolina 500-bus power system model using hurricane contingencies that capture possibilities for an extreme contingency. DCAT’s advanced data management and interactive visualization can help planning engineers to visually explore and analyze system behavior, all in one view.

Cascading, dynamic simulations, database managemen↗

Understanding the Capabilities and Limitations of the Controls and Operations of High Voltage Direct Current (HVdc) Converters in Interconnected Electric Power Systems

This project will seek to build a fundamental understanding, and capability, to model and simulate the controls and operations of high voltage direct current (HVdc) converter stations in an electromagnetic simulation environment. While HVdc stations have been operated in the United States for over 50 years, these are typically simple two terminal point-to-point systems. Recently multi-terminal systems have begun to be deployed. The challenge with these new multi-terminal systems is that they often use different control schemes on the different terminals. The interactions of existing and new controls, and the fact that HVdc systems are rates in the 1,000’s of MWs means that small control instabilities can have dramatic impacts to bulk power systems. Despite these challenges, the operational capabilities of HVdc make them an attractive option for the transfer of the large amounts of renewable electricity that will be necessary for decarbonization of the nation’s electrical infrastructure and other sectors.

42 ENGINEERING↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

Real-time Simulation of Coordinated Sub-Transmission Volt-Var Control Tool under High Distributed PV Penetration

With the rapid penetration of intermittent solar photovoltaic (PV) and other distributed energy resources (DER) into the grid, and subsequent changes in power flow patterns in both distribution and sub-transmission, voltage regulation is becoming a major challenge. It is prudent to leverage PV and DER to provide ancillary services to the grid, such as voltage regulation. Recently, a quasi-static, coordinated real-time sub transmission volt-var control algorithm (CReST-VCT) was developed for voltage regulation under high PV penetration by dispatching the reactive power settings of the shunt devices and PV inverters. The algorithm was validated offline, on a quasistatic study. Such quasi-static dispatching algorithms cannot guarantee its performance for highly nonlinear dynamical power systems. In this paper the performance of the algorithm is validated with a real time nonlinear dynamic simulation of a modified IEEE 118 bus system in Opal-RT. The real time simulation is used to emulate the actual system operation, providing a more realistic testing environment for CReST-VCT. The dispatch and control signals are communicated between the power system (Opal solver) and the control center (GAMS solver) in real-time with a MODBUS bridge. The results demonstrate i) system is stable with the new dispatch points ii) significant improvement in system-wide voltage profiles compared to an uncontrolled scenario. Another significant contribution of the work is developing a framework for dispatchable, long duration dynamic simulations that can be leveraged for market/dispatch studies.

CReST-VCT, Opal-RT, Volt/Var Control, renewable in↗

Power-Domain Impedance Theory for the Analysis and Mitigation of Interarea Oscillations: Preprint

This paper presents an impedance-based theory for the analysis and mitigation of interarea oscillations in power systems. Because low-frequency power system oscillations primarily manifest in phasor quantities, including active and reactive power flows, and the magnitude and frequency of bus voltages, a new-type of impedance, called power-domain impedance, is defined in terms of these phasor quantities. The power-domain impedance provides an intuitive framework for the analysis of interarea oscillations without requiring internal details of generators, and it is ideally suited for developing oscillation damping controls in inverter-based resources. The power-domain impedance theory is demonstrated in this paper using PSCAD simulations of a two-area system. The theory is also used for designing damping control in synchronous generators and a wind power plant in the two-area system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupling of CTF and RELAP5-3D Within an Enhanced Fidelity Nuclear Power Plant Simulator

A robust and accurate multiphysics engineering simulator is being developed to model the core behavior and system response of pressurized water reactors. This simulator relies on the NESTLE and CTF computer codes to model the neutronics and thermal hydraulics (TH), respectively, inside the core on a nodal scale and on the Reactor Excursion and Leak Analysis Program—Three Dimensional (RELAP5-3D) to model the entire nuclear steam supply system. The RELAP5-3D model includes highly detailed nodalization and multidimensional flow modeling throughout the vessel. Previously, pin-resolved data generated via the Virtual Environment for Reactor Analysis core simulator were used to improve the accuracy of the NESTLE core predictions. The engineering simulator being developed as part of this work uses the 3KEYMASTER platform to couple the enhanced NESTLE model to a nodal-fidelity CTF model to balance run time with accuracy; NESTLE provides node-dependent powers to CTF, and CTF provides node-dependent coolant densities and fuel temperatures to NESTLE.An overlapping domain approach is used for the core TH in which RELAP5-3D provides core boundary conditions based on the system response and CTF provides a node-dependent coolant heating rate to the RELAP5-3D core solution. In the preliminary TH demonstration discussed in this paper, CTF and RELAP5-3D provided similar steady-state core predictions, indicating the hydraulic compatibility between the codes, as well as reasonable and expected behavior under hypothetical transient conditions. This provides an initial step in ongoing efforts toward a robust, multiscale TH/neutronics engineering simulator capability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗