Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system event”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation: Preprint

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.

droop control↗

Beryllium Isotopes in Rainfall for Stratospheric-Tropospheric Exchange Dynamics Experiment (BIRDIE) (Final Report)

The Beryllium Isotopes in Rainfall for Stratospheric-Tropospheric Exchange Dynamics Experiment or BIRDIE was a precipitation collection campaign designed to measure cosmogenic isotopes of beryllium in rainfall and other forms of precipitation across the DOE Southern Great Plains (SGP) Atmospheric Radiation Measurement (ARM) site. Precipitation samples were collected over three weeks (May 21-June 10, 2022) at 11 SGP sites across a 120 km 2 domain in northern and central Oklahoma. The field campaign targeted summer-time convection rain events. We aimed to capture any spatial and/or temporal variability in the concentrations of beryllium-10 (10Be) and beryllium-7 (7Be) across the SGP ARM site during these rainfall events. The ratio of 10Be to 7Be (10/7Be) has been shown to be a powerful tracer for transport processes in the stratosphere-troposphere exchange (STE) system (e.g., Koch and Rind 1998). Any observed variability is analyzed to see if it could be linked to STE processes, including overshooting of deep convection clouds which penetrate the lower stratosphere. Six wet weather system events were collected within our three-week span. Five out of six of these rainfall events are classified as moderately to strongly convective. Those events are studied in more detail. The five systems also follow each other over a short time period of eleven days. In our rainfall samples we observed spatial and event variability in the concentrations of beryllium-10 and -7 which resulted in variability of 10/7 Be ratios. Each weather event appeared to exhibit a unique 10/7Be pattern across the domain that was not directly linked to storm total precipitation amount. To better understand the causes for this spatial variability, cloud characteristics in the domain were looked at to assess cloud type, cloud height and depth information. We also ran Hysplit back trajectories to identify possible air mass and moisture origins across our events. Detailed analysis is still on-going. The purpose of this technical report is to provide background on using cosmogenic isotopes as atmospheric tracers, describe the experimental design, and present the beryllium concentration and ratio data.

58 GEOSCIENCES↗

Beryllium Isotopes in Rainfall for Stratospheric-Tropospheric Exchange Dynamics Experiment (BIRDIE) (Field Campaign Report)

The Beryllium Isotopes in Rainfall for Stratospheric-Tropospheric Exchange Dynamics Experiment or BIRDIE was a precipitation collection campaign designed to measure cosmogenic isotopes of beryllium in rainfall and other forms of precipitation across the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) atmospheric observatory. Precipitation samples were collected over three weeks (May 21-June 10, 2022) at 11 SGP sites across a 120-km 2 domain in northern and central Oklahoma. The field campaign targeted summertime convection rain events. We aimed to capture any spatial and/or temporal variability in the concentrations of beryllium-10 (10Be) and beryllium-7 (7Be) across the ARM SGP site during these rainfall events. The ratio of 10Be to 7Be (10/7Be) has been shown to be a powerful tracer for transport processes in the stratosphere-troposphere exchange (STE) system (e.g., Koch and Rind 1998). Any observed variability is analyzed to see if it could be linked to STE processes, including overshooting of deep convection clouds that penetrate the lower stratosphere. Six wet weather system events were collected within our three-week span. Five out of six of these rainfall events are classified as moderately to strongly convective. Those events are studied in more detail. The five systems also follow each other over a short period of 11 days. In our rainfall samples we observed spatial and event variability in the concentrations of beryllium-10 and -7 that resulted in variability of 10/7Be ratios. Each weather event appeared to exhibit a unique 10/7Be pattern across the domain that was not directly linked to storm total precipitation amount. To better understand the causes for this spatial variability, cloud characteristics in the domain were looked at to assess cloud type, cloud height, and depth information. We also ran Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model back trajectories to identify possible air mass and moisture origins across our events. Detailed analysis is ongoing. The purpose of this technical report is to provide background on using cosmogenic isotopes as atmospheric tracers, describe the experimental design, and present the beryllium concentration and ratio data. Lastly, we note that BIRDIE coincided with two other deep convection field campaigns in the area: The National Aeronautics and Space Administration (NASA)’s Dynamics and Chemistry of the Summer Stratosphere (DCOTSS) experiment (https://dcotss.org/) centered in Salina, Kansas, and the Targeted Observation by Radars and (uncrewed aerial systems) UAS of Supercells (TORUS) experiment (https://catalog.eol.ucar.edu/torus_2022) across the U.S. Central Plains. Additionally, a Lawrence Livermore National Laboratory ( LLNL) team at DCOTSS attempted to measure 10Be/7Be ratios on aerosols collected in situ in the lower and mid-stratosphere over Kansas using high-altitude balloons. Precipitation samples were also collected on the ground in Salina, Kansas.

54 ENVIRONMENTAL SCIENCES↗

Enhancing EV Charging Station Resilience with Multifunctional Converter Leg Integration

In this paper, a multifunctional converter leg is integrated into an EV charger’s power circuit to enhance EV charging station resilience under power electronics converter device faults and grid outages. In the event of a device fault, it substitutes the failed converter leg, maintaining operation. During a grid outage, it assists the system as a fourth leg to the front-end converter, enabling grid-forming capability to supply power to the charging station critical loads while allowing limited power vehicle charging. The proposed approach’s effectiveness under both front-end power converter device faults and grid outage scenarios are validated through simulation and controller hardware-in-the-loop results.

Pereira Pinto, Joao [ORNL]↗

Overcoming Resilience Challenges on the Outer Banks of North Carolina

In 2021, the Town of Nags Head, located in the Outer Banks region of North Carolina, was among the first cohort of coastal and island communities to participate in the U.S. Department of Energy's Energy Transitions Initiative Partnership Project (ETIPP), which offers technical assistance and cash awards to competitively selected coastal, remote, and island communities seeking to transform their energy systems and increase their energy resilience. As a barrier island separated from mainland North Carolina, Nags Head experiences impacts from extreme weather events, including power outages, especially during hurricane season. To address challenges, the Nags Head ETIPP team sought to improve the town's disaster resilience by ensuring that critical facilities can remain powered during and after extreme events. With support from experts at Sandia National Laboratories, the National Renewable Energy Laboratory, and the Coastal Studies Institute, the community team identified the following goals for its participation in ETIPP: 1. Identify and prioritize critical facilities that, when powered during disruptions, support the town's resilience. 2. Analyze the potential for on-site solar photovoltaic (PV) and storage systems at 2-4 prioritized critical facilities owned and/or operated by the town. 3. Analyze the potential for interconnecting solar PV and storage systems at a cluster of public and privately owned facilities into a resilient microgrid. 4. Explore finance options and utility interconnection requirements and compensation mechanisms. 5. Summarize outcomes and next steps for town leadership.

25 ENERGY STORAGE↗

Residential Vehicle-to-Home Backup Power Capabilities: Key Findings from a ComEd Beneficial Electrification R&D Pilot

This report summarizes key findings from a collaborative technical study of residential, non-grid-tied vehicle-to-home (V2H) backup power systems in Commonwealth Edison’s (ComEd’s) service territory. The work integrates (1) a feeder-level technoeconomic analysis (TEA) using historical outage-event data and simulated electric-vehicle (EV) driving/charging profiles to estimate potential reliability and customer interruption-cost impacts under V2H and vehicle-to-grid (V2G) adoption scenarios; (2) controlled laboratory performance testing of a representative V2H backup ecosystem to characterize transfer-to-backup behavior, sustained power delivery, efficiency trends, and repeatable reliability limitations; and (3) a cybersecurity assessment aligned with NIST Cybersecurity Framework (CSF) 2.0 and ISO/SAE 21434 to evaluate interface-level risk drivers and identify program-relevant mitigations. Results indicate that V2H can provide measurable resilience value, but outcomes are strongly context dependent on outage patterns and the share of events that are “V2H-applicable.” Typical transfer-to-backup behavior clustered on the order of minutes, but rare long-delay edge cases were observed (including an event approaching 30 minutes) and should be treated as a reliability risk. High-power testing showed that peak-rated output is not necessarily continuously deliverable; stable operation may require operation below nameplate ratings and attention to thermal and installation constraints. The cybersecurity assessment highlights a broad attack surface spanning commissioning, home networks, embedded services, and cloud/OTA pathways, motivating minimum controls for secure onboarding, signed updates, patch cadence, and coordinated vulnerability response for any scaled deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Machine Learning Framework to Deconstruct the Primary Drivers for Electricity Market Price Events

As the electricity grid is moving towards a 100% Renewable Energy Source Bulk Power Grid, the overall operations of the power system operations and electricity markets are changing. The electricity markets are not only dispatching resources economically but also taking into account various controllable actions like renewable curtailment, transmission congestion mitigation, and energy storage optimization to make sure the grid is operating reliably. As a result, price formations in electricity markets have become quite complex. Traditional root cause analysis and statistical approaches are rendered inapplicable to analyze and infer the main drivers behind price formation in the modern grid and markets with variable renewable energy (VRE). In this paper, we propose a machine learning analysis framework to deconstruct some primary drivers for price formation in modern electricity markets with high renewable energy and the outcomes can be utilized for various critical aspects of market design, renewable dispatch and curtailment, operations, and cyber-security applications. The framework can be applied to any ISO or market data and in this paper it is applied to open-source publicly available datasets from California Independent System Operator (CAISO) and ISO New England.

machine learning (ML), electricity markets, Renewa↗

Synchrophasor Measurements-based Events Detection Using Deep Learning

Deep learning algorithms have been developed for phasor measurement units (PMUs) analysis aiming at providing grid operators to observe and react to significant real-time changes in the grid associated with multiple factors (e.g., power generation and load variations, different type of faults, and equipment mailfunction), or for offline post-event system diagnostics. In this study, a Long Short-Term Memory (LSTM)-based deep neural network (DNN) is adopted and evaluated to identify the most appropriate model configurations for event detection and longer-term anomalous pattern extraction. The proposed DNN model shows the potential on long-term predictions with the ability to capture nonlinear and nonstationary mixture complex patterns in PMU datasets. Real-world PMU in the WECC system were used for model development and validation.

deep learning↗

Securing Inverter Communication: Proactive Intrusion Detection and Mitigation System to Tap, Analyze, and Act

The electric grid has undergone rapid, revolutionary changes in recent years; from the addition of advanced smart technologies to the growing penetration of distributed energy resources (DERs) to increased interconnectivity and communications. However, these added communications, access interfaces, and third-party software to enable autonomous control schemes and interconnectivity also expand the attack surface of the grid. To address the gap of DER cybersecurity and secure the grid-edge to motivate a holistic, defense-in-depth approach, a proactive intrusion detection and mitigation system (PIDMS) device was developed to secure PV smart inverter communications. The PIDMS was developed as a distributed, flexible bump-in-the-wire (BITW) solution for protecting PV smart inverter communications. Both cyber (network traffic) and physical (power system measurements) are processed using network intrusion monitoring tools and custom machinelearning algorithms for deep packet analysis and cyber-physical event correlation. The PIDMS not only detects abnormal events but also deploys mitigations to limit or eliminate system impact; the PIDMS communicates with peer PIDMSs at different locations using the MQTT protocol for increased situational awareness and alerting. The details of the PIDMS methodology and prototype development are detailed in this report as well as the evaluation results within a cyber-physical emulation environment and subsequent industry feedback.

14 SOLAR ENERGY↗

Weather-Driven Resilience for Distribution Systems

With increasing billion dollar disasters due to weather events, it is of utmost priority for utility and grid operators to maintain and enhance the resilience of distribution grid. Traditionally, such analysis were conducted with reliability metrics alone. However, with increasing complexity of distribution grid and advancements in grid edge resources, evaluating grid resilience is challenging and involves multi-faceted analysis of the impact of weather events on the distribution grid. This presentation provides background, details, and future works in the field of weather-driven resilience for power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

What Technical Choices Matter to Characterize Heat Wave and Cold Snap Events in Support of Bulk Power Grid Reliability Studies?

Extreme weather events, such as Heat Waves (HW) and Cold Snaps (CS), pose significant risks to the power grid. The United States (U.S.) Federal Energy Regulatory Commission Order No. 896 mandates regional coordination standards that account for extreme thermal events. However, the lack of a universal definition for extreme thermal events may lead to inconsistent compliance efforts among neighboring entities, undermining the reliability of the transmission system. This study directly addresses this challenge by systematically evaluating how varying technical choices in defining HW and CS fundamentally impact the characterization and ranking of extreme events for power grid reliability studies. We used 12 event definitions and multiple temperature spatial aggregation approaches to construct historical (1980–2024) regional extreme thermal event libraries across North American Electric Reliability Corporation (NERC) subregions in the conterminous U.S. We examined the sensitivity of event characteristics (e.g., duration, frequency, intensity, and spatial coverage) to different definitions. While some definitions produced similar libraries and top event rankings, definitions based on moving-window-averaged temperatures yielded markedly different characteristics. Spatial aggregation methods had minimal impact on heat wave or cold snap intensity, frequency and duration but significantly influenced spatial coverage. The top events identified across different aggregation methods were consistent, but their ranking order varied. These findings offer critical insights for characterizing and selecting extreme thermal events and for supporting local and cross-regional coordination as required by reliability standards.

Wan, Heng [Pacific Northwest National Laboratory (↗

Situational Awareness of Grid Anomalies (SAGA)

The modern power industry becomes more vulnerable to cyber events due to the growing interconnectivity, interdependence, and complexity of the electric power grid. High-fidelity modeling and simulation tools that support the preventative risk analysis on potential cyber-relevant events is essential for ensuring the situational awareness of the system operator as it provides an inexpensive and risk-free environment to test the system responses under various cyber-relevant events and hereby can support research on cyber anomaly detection, optimal protective resource allocation, and mitigation measures. In this webinar, we will share NREL's cybersecurity research capabilities by highlighting the development of a scalable cyber-physical event test bed and demonstration with real hardware in the loop. The developed cyber-physical event test bed is backboned by an integrated transmission, distribution, and communication dynamic co-simulation framework and a plug-and-play cyber event generation module. It is designed to be modular and compatible with parallel computing, and thereby supports large-scale system simulations at an affordable computation cost. The test bed can capture millisecond-to-minutes dynamic frequency and voltage responses under cyber events from the bulk transmission system to the active distribution systems and distributed energy resources at the grid edge.

co-simulation↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2018

This report presents an enhanced performance evaluation of emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES) data from 1998 through 2018 and (2) maintenance unavailability (UA) performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2018. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in NRC probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. Engineering analyses were performed with respect to time period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed are: sub-component, failure cause, detection method, recovery, manufacturer, and EDG rating. A statistically significant increasing trend was identified in the frequency of FTLR demands for emergency power system (EPS) and high pressure core spray (HPCS) EDGs and a statistically significant decreasing trend was identified in the frequency of run > 1H hours for EPS and HPCS EDGs.

99 GENERAL AND MISCELLANEOUS↗

Event-Based Analysis of Solar Power Distribution Feeder Using Micro-PMU Measurements

Solar distribution feeders are commonly used in solar farms that are integrated into distribution substations. In this paper, we focus on a real-world solar distribution feeder and conduct an event-based analysis by using micro-PMU measurements. The solar distribution feeder of interest is a behind-the-meter solar farm with a generation capacity of over 4 MW that has about 200 low-voltage distributed photovoltaic (PV) inverters. The event-based analysis in this study seeks to address the following practical matters. First, we conduct event detection by using an unsupervised machine learning approach. For each event, we determine the event’s source region by an impedancebased analysis, coupled with a descriptive analytic method. We segregate the events that are caused by the solar farm, i.e., locallyinduced events, versus the events that are initiated in the grid, i.e., grid-induced events, which caused a response by the solar farm. Second, for the locally-induced events, we examine the impact of solar production level and other significant parameters to make statistical conclusions. Third, for the grid-induced events, we characterize the response of the solar farm; and make comparisons with the response of an auxiliary neighboring feeder to the same events. Fourth, we scrutinize multiple specific events; such as by revealing the dynamics to the control system of the solar distribution feeder. The results and discoveries in this study are informative to utilities and solar power industry.

14 SOLAR ENERGY↗

Connecting Risk and Resilience for a Power System Using the Portland Hills Fault Case Study

Active seismic faults in the Pacific Northwest area have encouraged electric utilities in the region to deeply contemplate and proactively intervene to support grid resilience. To further this effort this research introduces Monte Carlo (MC)-based power system modeling as a means to inform the Performance Based Earthquake Engineering method and simulates 100,000 sample earthquakes of a 6.8 magnitude (M6.8) Portland Hills Fault (PHF) scenario in the Portland General Electric (PGE) service territory as a proof of concept. This paper also proposes the resilience metric Seismic Load Recovery Factor (SLRF) to quantify the recovery of a downed power system and thus can be used to quantify earthquake economic risk. Using MC results, the SLRF was evaluated to be 19.7 h and the expected economic consequence cost of a M6.8 PHF event was found to be $\$180$ million with an annualized risk of $\$90,000$ given the event’s 1 in 2000 year probability of occurrence. The MC results also identified the eight most consequential substations in the PGE system—i.e., those that contributed to maximum load loss. This paper concludes that retrofitting these substations reduced the expected consequence cost of a M6.8 PHF event to $117 million.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Optimization of the Cryogenic Moderator System Controller at the Spallation Neutron Source for Improved Performance

The high-energy neutron beam generated at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is moderated to use cold (slow) neutrons for scientific discoveries. The Cryogenic Moderator System (CMS) removes heat from the neutron beam using cryogenic hydrogen (H 2 ) moderators connected via heat exchangers to a helium (He) refrigeration loop that dissipates heat using a compressor-brake system. However, the CMS is affected by sporadic losses in beam power, referred to as "beam trips," as these events generate significant disturbances in cooling requirements. To accommodate the heat load transients during beam trips, the CMS uses a decentralized control strategy consisting of four flow valves and one electric heater adjusted by independent proportional-integral (PI) controllers. During the CMS’s initial commissioning, the PI gains were calibrated based only on tracking performance, overlooking their effectiveness in disturbance rejection. A data-driven, control-oriented closed-loop model was developed to recalibrate the PI gains and minimize the transient disturbances caused by beam trips. The model consists of three main components: (1) a physics-based model of the He refrigeration loop, (2) a machine-learning model of the cryogenic H 2 cooling trains, and (3) the control logic used for feedback set-point tracking. Experimental results showed that the recalibrated gains obtained in this study improved the CMS’s transient response during beam trips.

Maldonado Puente, Bryan↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗