Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “physical exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Myotonometry as a Surrogate Measure of Muscle Strength

Space flight-induced muscle atrophy/neuromuscular degradation and the consequent decrements in crew-member performance are of increasing concern as mission duration lengthens, and planetary exploration after extended space flight is planned. Pre- to post-flight strength measures have demonstrated that specific countermeasures, such as resistive exercise, are effective at countering microgravity-induced muscle atrophy and preventing decrements in muscle strength. However, in-flight assessment/monitoring of exercise countermeasure effectiveness will be essential during exploration class missions due to their duration. The ability to modify an exercise countermeasure prescription based on such real-time information will allow each individual crew member to perform the optimal amount and type of exercise countermeasure to maintain performance. In addition, such measures can be used to determine if a crew member is physically capable of performing a particular mission-related task during exploration class missions. The challenges faced in acquiring such data are those common to all space operations, namely the requirement for light-weight, low power, mechanically reliable technologies that make valid measurements in microgravity, in this case of muscle strength/neuromuscular function. Here we describe a simple, light-weight, low power, non-invasive device, known as the Myotonometer, that measures tissue stiffness as an indirect measure of muscle contractile state and muscle force production. Repeat myotonometer measurements made at the same location on the surface of the rectis femoris muscle (as determined using a 3D locator device, SEM plus or minus 0.34 mm) were shown to be reproducible over time at both maximal voluntary contraction (MVC) and at rest in a total of 17 sedentary subjects assessed three times over a period of seven days. In addition, graded voluntary isometric force production (i.e. 20%, 40%, 60%, 80% & 100% of MVC) during knee extension was shown to be significantly (p less than 0.01) correlated with contemporaneous myotonometer measurements made on the rectis femoris muscle in a total of 16 healthy subjects (8 males, 8 females). Further-more, this device has been operationally tested during parabolic flight demonstrating its suitability for use in a microgravity environment. Our data indicates that the Myotonometer is a viable surrogate measure of muscle contractile state/tone and of muscle strength/force production. Additional studies are required to assess the suitability of this technique for assessing these measures in de-conditioned subjects such as crew-members.

Ang, B. S.↗

Liquid Cooling/Warming Garment

The NASA liquid cooling/ventilating garment (LCVG) currently in use was developed over 40 years ago. With the commencement of a greater number of extra-vehicular activity (EVA) procedures with the construction of the International Space Station, problems of astronaut comfort, as well as the reduction of the consumption of energy, became more salient. A shortened liquid cooling/warming garment (SLCWG) has been developed based on physiological principles comparing the efficacy of heat transfer of different body zones; the capability of blood to deliver heat; individual muscle and fat body composition as a basis for individual thermal profiles to customize the zonal sections of the garment; and the development of shunts to minimize or redirect the cooling/warming loop for different environmental conditions, physical activity levels, and emergency situations. The SLCWG has been designed and completed, based on extensive testing in rest, exercise, and antiorthostatic conditions. It is more energy efficient than the LCVG currently used by NASA. The total length of tubing in the SLCWG is approximately 35 percent less and the weight decreased by 20 percent compared to the LCVG. The novel features of the innovation are: 1. The efficiency of the SLCWG to maintain thermal status under extreme changes in body surface temperatures while using significantly less tubing than the LCVG. 2. The construction of the garment based on physiological principles of heat transfer. 3. The identification of the body areas that are most efficient in heat transfer. 4. The inclusion of a hood as part of the garment. 5. The lesser consumption of energy.

Koscheyev, Victor S.↗

Effect of exercise training on cardiopulmonary baroreflex control of forearm vascular resistance in humans

We studied the stimulus-response characteristics of cardiopulmonary baroreflex control of forearm vascular resistance (FVR) in four groups of male volunteer subjects: i) unfit, ii) physically fit, iii) before and after 10 wk of endurance training (chronic blood volume expansion), and iv) before and after acute blood volume expansion. We assessed the relationship between reflex stimulus, i.e., changes in central venous pressure and response, i.e., FVR, during unloading of cardiopulmonary mechanoreceptors with lower body negative pressure (LBNP, 0 to -20 mm Hg). The slope of the linear relationship between FVR and CVP, the index of the responsiveness of this baroreflex, was significantly diminished (> 50%) in the fit subjects compared with the unfit. The slope of the FVR-CVP relationship was inversely correlated with the subject's total blood volume, suggesting that blood volume expansion was related to the attenuated CP baroreflex. In the exercise training study, maximal oxygen consumption and blood volume increased following 10 wk of endurance training (N = 14) but were unchanged in the time control group (N = 7). The slope of the FVR-CVP relationship was significantly reduced (32%) following 10 wk of training but was unchanged in the time control group. The reduction in slope of the FVR-CVP relationship was inversely related to the increase in blood volume associated with exercise training. Acute blood volume expansion 8 ml.kg-1 body weight with 5% human serum albumin solution) significantly reduced the slope of the FVR-CVP relationship. These data support the hypothesis that the attenuated forearm vascular reflex in physically fit individuals is related to a training-induced hypervolemia.(ABSTRACT TRUNCATED AT 250 WORDS).

Review↗

SHARP Assembly-Scale Multiphysics Demonstration Simulations

The NEAMS Reactor Product Line effort aims to develop an integrated multiphysics simulation capability for the design and analysis of future generations of nuclear power plants. The Reactor Product Line code suite’s multi-resolution hierarchy is being designed to ultimately span the full range of length and time scales present in relevant reactor design and safety analyses, as well as scale from desktop to petaflop computing platforms. In this report, we describe our efforts to integrate thermal/hydraulics, neutronics, and structural mechanics modeling codes to perform coupled analysis of a representative fast sodium-cooled reactor fuel assembly. Over the past five years, the Reactor Product Line effort has developed high-fidelity single-physics codes for neutron transport modeling, in the PROTEUS code, and Large Eddy Simulation-based thermal/fluid modeling in the Nek5000 code. Both these codes have been exercised on over 100,000 processors of the IBM Blue Gene/P. The Diablo code has been used to perform structural mechanics and thermo-mechanical modeling. MOAB, the Reactor Geometry Generator (RGG), and MeshKit have been developed to generate and manipulate mesh and mesh-based data, in both serial and parallel environments. These tools together form a strong basis on which to build a multi-physics modeling capability. The goal of developing such a tool is to perform multi-physics neutronics, thermal/fluid, and structural mechanics modeling of the components inside a reactor core. While the focus of this report is on modeling a fast sodium-cooled reactor, it is also the goal that this simulation tool be useful for most reactor types. Here we report on the integration of PROTEUS and Nek5000 into the NEAMS framework. Both codes have been modified to read and write data from and to the MOAB library, in both serial and parallel environments. We focused on broad support for as many original physics code options as possible, rather than focusing only on near-term needs. Both codes were demonstrated through this interface on a relatively simple, seven-pin hexagonal fuel assembly. To support coupled analysis, the new multi-physics driver library COUPE was developed; this library provides flexible support for both loose and tight coupling, and can interface flexibly with codes in multiple programming languages. To couple results between the separate meshes used in each physics, the driver, PROTEUS, and Nek5000 all interface with the MBCoupler solution transfer tool provided with MOAB. Together, these tools form the basis of a new, coupled neutronics and thermal/fluid modeling code, that works in both serial and parallel. In a related effort, a driver in the Diablo code was used to access Nek5000-computed results written to a MOAB database, as well as the temperature data used to drive structural mechanics computations.

Tautges, Timothy J.↗

The hemodynamic effects of repeated bed rest exposure

The effects of three 2-week periods of bed rest (with and without isometric/aerobic exercise, and separated by 3-week ambulatory recovery periods) on hemodynamic responses to stepwise application of LBNP (-20 to -40 mm Hg) are investigated experimentally in seven physically active male subjects aged 19-21 years. The data are presented in extensive tables and graphs and characterized in detail. It is found that bed rest produces significant changes in the responses of heart rate and end-diastolic volume index which (1) are greater than can be accounted for by lowered plasma volume, (2) persist during the recovery periods, and (3) do not respond to the exercises employed to prevent deconditioning.

Sandler, Harold↗

The NASA-USPHS Health Evaluation and Enhancement Program

An exercise program was initiated to assess the feasibility of an on the job health evaluation and enhancement program, as well as to identify the factors which influenced volunteering, adherence, and effectiveness of the program. The program was utilized by 237 of the 998 eligible Federal employees, with a mean attendance of 1.3 days per week. Those who volunteered perceived a need for increased physical activity, felt they had sufficient time to participate, and derived subjective as well as objective benefits. Significant improvements were found in heart rate response to the standard exercise test, body weight, skinfold measurements, and triglycerides. A consistent relationship was found between subjectively reported effects of the program on work, health habits, and behavior, and improvement in cardiovascular function, based on treadmill performance. Numerous personal and programmatic factors influencing volunteering and participation were identified.

Durbeck, D. C.↗

Verification of the ideal magnetohydrodynamic response at rational surfaces in the VMEC code

The VMEC nonlinear ideal MHD equilibrium code [S. P. Hirshman and J. C. Whitson, Phys. Fluids 26, 3553 (1983)] is compared against analytic linear ideal MHD theory in a screw-pinch-like configuration. The focus of such analysis is to verify the ideal MHD response at magnetic surfaces which possess magnetic transform (ι) which is resonant with spectral values of the perturbed boundary harmonics. A large aspect ratio circular cross section zero-beta equilibrium is considered. This equilibrium possess a rational surface with safety factor q = 2 at a normalized flux value of 0.5. A small resonant boundary perturbation is introduced, exciting a response at the resonant rational surface. The code is found to capture the plasma response as predicted by a newly developed analytic theory that ensures the existence of nested flux surfaces by allowing for a jump in rotational transform (ι=1/q). The VMEC code satisfactorily reproduces these theoretical results without the necessity of an explicit transform discontinuity (Δι) at the rational surface. It is found that the response across the rational surfaces depends upon both radial grid resolution and local shear (dι/dΦ, where ι is the rotational transform and Φ the enclosed toroidal flux). Calculations of an implicit Δι suggest that it does not arise due to numerical artifacts (attributed to radial finite differences in VMEC) or existence conditions for flux surfaces as predicted by linear theory (minimum values of Δι). Scans of the rotational transform profile indicate that for experimentally relevant levels of transform shear the response becomes increasing localised. Furthermore, careful examination of a large experimental tokamak equilibrium, with applied resonant fields, indicates that this shielding response is present, suggesting the phenomena is not limited to this verification exercise.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Table of Standard Atomic Weights—an exercise in consensus

The present Table of Standard Atomic Weights (TSAW) of the elements is perhaps one of the most familiar datasets in science. Unlike most parameters in physical science whose values and uncertainties are evaluated using the “Guidelines for Uncertainty in Measurement” (GUM), the majority of standard atomic-weight values and their uncertainties are consensus values, not GUM-evaluated values. The Commission on Isotopic Abundances and Atomic Weights of the International Union of Pure and Applied Chemistry (IUPAC) regularly evaluates the literature for new isotopic-abundance measurements that can lead to revised standard atomic-weight values, A r (E) for element E. The Commission strives to provide utmost clarity in products it disseminates, namely the TSAW and the Table of Isotopic Compositions of the Elements (TICE). In 2016, it was recognized by the Commission that a guideline recommending expression of uncertainty listed in parentheses following the standard atomic-weight value, e.g. A r (Se) = 78.971(8), is not in accord with the GUM, which suggests that this parenthetic notation be reserved to express standard uncertainty, not the expanded uncertainty used in the TSAW and TICE. In 2017, to eliminate this noncompliance with the GUM, a new format was adopted in which the uncertainty value is specified by the plus-minus symbol, e.g. A r (Se) = 78.971 ± 0.008. To clarify the definition of uncertainty, a new footnote has been added to the TSAW. This footnote emphasizes that an atomic-weight uncertainty is a consensus (decisional) uncertainty. Not only has the Commission shielded users of the TSAW and TICE from unreliable measurements that appear in the literature as a result of unduly small uncertainties, but the aim of IUPAC has been fulfilled by which any scientist, taking any natural sample from commerce or research, can expect their sample atomic weight to lie within A r (E) ± its uncertainty almost all of the time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Attenuating Effect of Vigorous Physical Activity on the Risk for Inherited Obesity: A Study of 47,691 Runners

Physical activity has been shown to attenuate the effect of the FTO polymorphism on body weight, and the heritability of body weight in twin and in family studies. The dose-response relationship between activity and the risk for inherited obesity is not well known, particularly for higher doses of vigorous exercise. Such information is needed to best prescribe an exercise dose for obesity prevention in those at risk due to their family history. We therefore analyzed self-reported usual running distance, body mass index (BMI), waist circumference, and mother’s and father’s adiposity (1 = lean, 2 = normal, 3 = overweight, and 4 = very overweight) from survey data collected on 33,480 male and 14,211 female runners. Age-, education-, and alcohol-adjusted regression analyses were used to estimate the contribution of parental adiposities to the BMI and waist circumferences in runners who ran an average of <3, 3–6, 6–9, ≥9 km/day. BMI and waist circumferences of runners who ran <3 km/day were significantly related to their parents adiposity (P<10 -15 and P<10 -11 , respectively). These relationships (i.e., kg/m 2 or cm per increment in parental adiposity) diminished significantly with increasing running distance for both BMI (inheritance x exercise interaction, males: P,10 -10 ; females: P,10 -5 ) and waist circumference (inheritance x exercise interaction, males: P<10 -9 ; females: P = 0.004). Compared to <3 km/day, the parental contribution to runners who averaged ≥9 km/day was diminished by 48% for male BMI, 58% for female BMI, 55% for male waist circumference, and 58% for female waist circumference. These results could not be attributed to self-selection. Exceeding the minimum exercise dose currently recommended for general health benefits (energy equivalent to running 2–3 km/day) may substantially diminish the risk for inherited obesity. The results are consistent with other research suggesting the physical activity dose required to prevent unhealthy weight gain is greater than that recommended for other health benefits.

59 BASIC BIOLOGICAL SCIENCES↗

Current ISS Exercise Countermeasures: Where are we now?

Current International Space Station (ISS) crew schedules include 1.5 h/d for completion of resistive exercise and 1 h/d of aerobic exercise , 6 d/wk. While ISS post flight decrements in muscle strength, bone m ineral density, and aerobic capacity improved in some crewmembers, de conditioning was still evident even with this volume of exercise. Res ults from early ISS expeditions show maximum loss in bone mineral density of the lumbar spine and pelvis in excess of 1.5% per month, with all crewmembers demonstrating significant bone loss in one or more re gions. Similarly, post flight muscle strength losses in the hamstring and quadriceps muscle groups exceeded 30% in the immediate post miss ion period in some crewmembers. Measures of aerobic capacity early in the mission show average decrements of 15%, but with onboard aerobic exercise capability, the crew has been able to "train up" over the co urse of the mission. These findings are highly variable among crewmem bers and appear to be correlated with availability and reliability of the inflight resistive exercise device (RED), cycle ergometer, and t readmill. This suite of hardware was installed on ISS with limited op erational evaluation in groundbased test beds. As a result, onorbit hardware constraints have resulted in inadequate physical stimulus, d econditioning, and increased risk for compromised performance during intra and extravehicular activities. These issues indicate that the c urrent ISS Countermeasures System reliability or validity are not ade quate for extendedduration exploration missions. Learning Objective: A better understanding of the status of ISS exercise countermeasures , their ability to protect physiologic systems, and recommendations for exploration exercise countermeasures.

Hayes, J. C.↗

Application of NEAMS Codes to Capture MSR Phenomena

This report documents work completed in FY21 under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program’s Molten Salt Reactor (MSR) Application Drivers activity at Argonne. The common focus was on identifying the modeling and simulation functional requirements for designing, licensing, and operating MSRs and applying those capabilities already developed in NEAMS tools to example problems of interest. The four main parts of this report each focuses on a specific area of simulation physics as it relates to MSR phenomena: fuel evolution, chemistry, computational fluid dynamics (CFD), and systems analysis. In terms of fuel evolution, which includes depletion, decay, on-line separations, and transmutation, the current state of computational capabilities for modeling this behavior in liquid-fueled molten salt reactor is discussed. Some of the functional requirements to accomplish the various applications of MSR fuel depletion modeling are highlighted, followed by a summary of recent approaches and code development activities. The chemistry functional requirements were discussed in the context of several applications of high importance for MSRs, such as corrosion, salt chemistry, and species transport. Each of these types of chemistry modeling have considerable impact on various aspects of reactor applications, including informing on reactor designs, improving operational efficiencies, analyzing safety and reactivity concerns, and estimating the mechanistic source term of the reactor. A brief overview is also provided on code development activities ongoing under NEAMS relevant to chemistry modeling of MSRs. In terms of CFD applications, the state-of-the-art spectral element code, Nek5000 was used to model the fluid dynamics within a full core of the Molten Salt Fast Reactor (MSFR) concept designed as part of the Euratom EVOL project. This concept was selected as the challenge problem because of its similar features to several U.S. industry concepts. The goal was to model some of the fast MSR design challenges, including potential large internal re-circulations, the need of accurate tracking of delayed neutron precursors (DNP), and the lack of relevant thermal-hydraulics models/correlations, etc. Therefore, a series of CFD models were created for the MSFR core cavity using a k – τ model two-equation model for the turbulence. These first full core results demonstrated that any potential recirculation zones could be properly identified with the current NEAMS CFD capabilities. The development of these models will also set the stage for future testing of Nek5000’s functionalities to model other MSR thermal-fluid phenomena. Lastly, the validation of SAM against experimental data from the Molten Salt Reactor Experiment, which started in FY19, continues with the inclusion of modeling the reactivity insertion tests. This involved using SAM and its point kinetics model for flowing fuel salt to recreate the time dependent power changes and response after positive reactivity insertions at the 1, 5, and 8 MWt power levels. Through these exercises, several code modifications were suggested to the SAM development team and accommodated to enable closer agreement with solid technical and physical justifications. These include adding a moderator reactivity feedback coefficient as an available input and modifying the solution approach for the point kinetics model. Additional SAM development suggestions for flowing fuel MSRs include adding the capability to allow the moderator power change proportionally with the reactor power and enabling specification of the power and DNP distributions separately.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Atoms in astronomy

Aspects of electromagnetic radiation and atomic physics needed for an understanding of astronomical applications are explored. Although intended primarily for teachers, this brochure is written so that it can be distributed to students if desired. The first section, Basic Topics, is suitable for a ninth-grade general science class; the style is simple and repetitive, and no mathematics or physics background is required. The second section, Intermediate and Advanced Topics, requires a knowledge of the material in the first section and assumes a generally higher level of achievement and motivation on the part of the student. These latter topics might fit well into junior-level physics, chemistry, or earth-science courses. Also included are a glossary, a list of references and teaching aids, class exercises, and a question and answer section.

Blanchard, P. A.↗

An approach to the parametric design of ion thrusters

A methodology that can be used to determine which of several physical constraints can limit ion thruster power and thrust, under various design and operating conditions, is presented. The methodology is exercised to demonstrate typical limitations imposed by grid system span-to-gap ratio, intragrid electric field, discharge chamber power per unit beam area, screen grid lifetime, and accelerator grid lifetime constraints. Limitations on power and thrust for a thruster defined by typical discharge chamber and grid system parameters when it is operated at maximum thrust-to-power are discussed. It is pointed out that other operational objectives such as optimization of payload fraction or mission duration can be substituted for the thrust-to-power objective and that the methodology can be used as a tool for mission analysis.

Wilbur, Paul J.↗

An approach to the parametric design of ion thrusters

A methodology that can be used to determine which of several physical constraints can limit ion thruster power and thrust, under various design and operating conditions, is presented. The methodology is exercised to demonstrate typical limitations imposed by grid system span-to-gap ratio, intragrid electric field, discharge chamber power per unit beam area, screen grid lifetime and accelerator grid lifetime constraints. Limitations on power and thrust for a thruster defined by typical discharge chamber and grid system parameters when it is operated at maximum thrust-to-power are discussed.

Wilbur, Paul J.↗

A physically cryptographic warhead verification system using neutron induced nuclear resonances

Arms control treaties are necessary to reduce the large stockpiles of the nuclear weapons that constitute one of the biggest dangers to the world. However, an impactful treaty hinges on effective inspection exercises to verify the participants’ compliance to the treaty terms. Such procedures would require verification of the authenticity of a warhead undergoing dismantlement. Previously proposed solutions lacked the combination of isotopic sensitivity and information security. Here we present the experimental feasibility proof of a technique that uses neutron induced nuclear resonances and is sensitive to the combination of isotopics and geometry. The information is physically encrypted to prevent the leakage of sensitive information. Our approach can significantly increase the trustworthiness of future arms control treaties while expanding their scope to include the verified dismantlement of nuclear warheads themselves.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dose-Response Relationship of Physical Activity to Premature and Total All-Cause and Cardiovascular Disease Mortality in Walkers

Purpose: To assess the dose-response relationships between cause-specific mortality and exercise energy expenditure in a prospective epidemiological cohort of walkers. Methods: The sample consisted of the 8,436 male and 33,586 female participants of the National Walkers’ Health Study. Walking energy expenditure was calculated in metabolic equivalents (METs, 1 MET = 3.5 ml O2/kg/min), which were used to divide the cohort into four exercise categories: category 1 (#1.07 MET-hours/d), category 2 (1.07 to 1.8 MET-hours/d), category 3 (1.8 to 3.6 MET-hours/d), and category 4 ($3.6 MET-hours/d). Competing risk regression analyses were use to calculate the risk of mortality for categories 2, 3 and 4 relative to category 1. Results: 22.9% of the subjects were in category 1, 16.1% in category 2, 33.3% in category 3, and 27.7% in category 4. There were 2,448 deaths during the 9.6 average years of follow-up. Total mortality was 11.2% lower in category 2 (P = 0.04), 32.4% lower in category 3 (P,10212) and 32.9% lower in category 4 (P = 10211) than in category 1. For underlying causes of death, the respective risk reductions for categories 2, 3 and 4 were 23.6% (P = 0.008), 35.2% (P,1025 ), and 34.9% (P = 0.0001) for cardiovascular disease mortality; 27.8% (P = 0.18), 20.6% (P = 0.07), and 31.4% (P = 0.009) for ischemic heart disease mortality; and 39.4% (P = 0.18), 63.8% (P = 0.005), and 90.6% (P = 0.002) for diabetes mortality when compared to category 1. For all related mortality (i.e., underlying and contributing causes of death combined), the respective risk reductions for categories 2, 3 and 4 were 18.7% (P = 0.22), 42.5% (P = 0.001), and 57.5% (P = 0.0001) for heart failure; 9.4% (P = 0.56), 44.3% (P = 0.0004), and 33.5% (P = 0.02) for hypertensive diseases; 11.5% (P = 0.38), 41.0% (P,1024 ), and 35.5% (P = 0.001) for dysrhythmias: and 23.2% (P = 0.13), 45.8% (P = 0.0002), and 41.1% (P = 0.005) for cerebrovascular diseases when compared to category 1. Conclusions: There are substantial health benefits to exceeding the current exercise guidelines.

59 BASIC BIOLOGICAL SCIENCES↗

Differential baroreflex control of heart rate in sedentary and aerobically fit individuals

PURPOSE: We compared arterial, aortic, and carotid-cardiac baroreflex sensitivity in eight average fit (maximal oxygen uptake, VO2max = 42.2+/-1.9 mL x kg(-1) x min(-1)) and eight high fit (VO2max = 61.9+/-2.2 mL x kg(-1) x min(-1)) healthy young adults. METHODS: Arterial and aortic (ABR) baroreflex functions were assessed utilizing hypo- and hyper-tensive challenges induced by graded bolus injections of sodium nitroprusside (SN) and phenylephrine (PE), respectively. Carotid baroreflex (CBR) sensitivity was determined using ramped 5-s pulses of both pressure and suction delivered to the carotid sinus via a neck chamber collar, independent of drug administration. RESULTS: During vasoactive drug injection, mean arterial pressure (MAP) was similarly altered in average fit (AF) and high fit (HF) groups. However, the heart rate (HR) response range of the arterial baroreflex was significantly attenuated (P < 0.05) in HF (31+/-4 beats x min(-1)) compared with AF individuals (46+/-4 beats x min(-1)). When sustained neck suction and pressure were applied to counteract altered carotid sinus pressure during SN and PE administration, isolating the ABR response, the response range remained diminished (P < 0.05) in the HF population (24+/-3 beats x min(-1)) compared with the AF group (41+/-4 beats x min(-1)). During CBR perturbation, the HF (14+/-1 beats-min(-1)) and AF (16+/-1 beats-min(-1)) response ranges were similar. The arterial baroreflex response range was significantly less than the simple sum of the CBR and ABR (HF, 38+/-3 beats x min(-1) and AF, 57+/-4 beats x min(-1)) in both fitness groups. CONCLUSIONS: These data confirm that reductions in arterial-cardiac reflex sensitivity are mediated by diminished ABR function. More importantly, these data suggest that the integrative relationship between the ABR and CBR contributing to arterial baroreflex control of HR is inhibitory in nature and not altered by exercise training.

NASA Discipline Cardiopulmonary↗

Radiation Oncology in Undergraduate Medical Education: A Literature Review

Purpose: To review the published literature pertaining to radiation oncology in undergraduate medical education. Methods and Materials: Ovid MEDLINE, Ovid MEDLINE Daily Update and EMBASE databases were searched for the 11-year period of January 1, 1998, through the last week of March 2009. A medical librarian used an extensive list of indexed subject headings and text words. Results: The search returned 640 article references, but only seven contained significant information pertaining to teaching radiation oncology to medical undergraduates. One article described a comprehensive oncology curriculum including recommended radiation oncology teaching objectives and sample student evaluations, two described integrating radiation oncology teaching into a radiology rotation, two described multidisciplinary anatomy-based courses intended to reinforce principles of tumor biology and radiotherapy planning, one described an exercise designed to test clinical reasoning skills within radiation oncology cases, and one described a Web-based curriculum involving oncologic physics. Conclusions: To the authors' knowledge, this is the first review of the literature pertaining to teaching radiation oncology to medical undergraduates, and it demonstrates the paucity of published work in this area of medical education. Teaching radiation oncology should begin early in the undergraduate process, should be mandatory for all students, and should impart knowledge relevant to future general practitioners rather than detailed information relevant only to oncologists. Educators should make use of available model curricula and should integrate radiation oncology teaching into existing curricula or construct stand-alone oncology rotations where the principles of radiation oncology can be conveyed. Assessments of student knowledge and curriculum effectiveness are critical.

62 RADIOLOGY AND NUCLEAR MEDICINE↗