Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Value of Behind-The-Meter Energy Storage for Buildings: A Case Study on a University Building in South Africa

Energy storage systems (ESS) have emerged to play an increasingly important role in modern, complex electricity grid systems due to their potential to balance power supply and demand. Furthermore, ESS systems offer the potential to smooth out electricity supply from variable sources such as wind and solar power. Beyond the technical value they bring to the design and operation of modern power systems, ESS also offer the potential to create economic value to owners through many use cases such as demand charge reduction through peak load shaving, and energy arbitrage, also known as time-of-use shifting. The potential to achieve widespread adoption of ESS systems is largely dependent on demonstrating value to would-be consumers. In this study, the value of one potential use case for ESS systems - “behind-the-meter” energy storage for buildings - is explored. Specifically, this value is explored through the lens of a case study of an academic building located on the Stellenbosch University campus in Western Cape, South Africa.

Odukomaiya, Wale O.↗

Evaluating the Cost Benefits of U.S. Utility-Scale Photovoltaics Plus Energy Storage Systems

Utility-scale photovoltaics (PV) system market growth has been rapid for several years. Today, with the cost reductions of energy storage technologies, the application of combing PV and energy storage has become feasible and beneficial, especially for the areas that only have PV standalone systems and need to shift the peak load to meet the evening electricity demand. Overall, the utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a systemlevel bottom-up cost modeling approach. We use this model to benchmark PV plus storage installation system cost and identify cost difference for AC and DC coupled systems and duration variation. Finally, we assess the cost reduction opportunities of co-locating PV system with energy storage system in order to indicate the possible economic impacts of PV plus storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

Implications of Battery Storage for Solar Net-Metering Reforms

Compensation structures for residential solar PV are evolving toward a model that incentivizes the use of battery storage to maximize solar self-consumption. Using metered data from 1,800 residential customers across six U.S. utilities, we show that batteries operated solely in this manner often provide no grid value, due to misalignment with market prices. Incentivizing customers to discharge storage in response to market prices, particularly on infrequent peak load days would greatly enhance storage dispatch value. However, doing so requires consideration of local distribution network impacts. We illustrate a net billing design that yields a storage dispatch value equal to 50-70% of its maximum potential market value, without materially degrading solar self-consumption levels or increasing local grid stress.

Barbose, Galen↗

Challenges to Rural Service Transformers on Increased Electric Vehicle Charging Infrastructure

As Electric Vehicle (EV) electric charging demand increases so to does the corresponding load requirements for charging the vehicles. The expansion of power distribution assets is therefore a critical issue to address on whether rural service transformers can handle the increase in EV load demand. Large-scale EV deployment is likely to cause problems in the localized distributions systems bringing challenges such as increased load demand, increased system losses, and additional voltage drops. This paper investigates how rural service transformer resiliency plays an important role in these challenges. EV charging can create new load peaks exceeding the service transformer's rated capacity, thereby accelerating equipment aging. EV charging can also both positively and negatively affect transformer aging. The core purpose of this paper is to investigate that change in service life of rural service transformers.

Mukherjee, Srijib↗

Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening

A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed study could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.

14 SOLAR ENERGY↗

An Open-Source Tool for Automated Power Grid Stress Level Prediction at Balancing Authorities

The behavior of modern power systems becomes more stochastic and dynamic, due to the increased penetration of variable generation, demand response, new power market structure, extreme weather conditions, contingencies, and unexpected events. It is critically important to predict potential system operational issues so that grid planners and operators can take preventive actions to mitigate the impact, e.g., lack of operational reserves. In this paper, an innovative software tool is presented to assist power grid operators in a balancing authority (BA) to predict the grid stress level over the next operating day. It periodically collects necessary information from public domain such as weather forecasts, electricity demand, and automatically estimates the stress levels on a daily basis. Advanced Neural Network and regression tree algorithms are developed as the prediction engines to achieve this goal. The tool has been tested on a few key balancing authorities that successfully predicates the growing system peak load and increased stress levels under extreme heat waves in the United States of America.

Berscheid, Alan P.↗

A DDS-Based Energy Management Framework for Small Microgrid Operation and Control

The smart grid is seen as a power system with realtime communication and control capabilities between the consumer and the utility. This modern platform facilitates the optimization in energy usage based on several factors including environmental, price preferences, and system technical issues. In this paper a real-time energy management system (EMS) for microgrids or nanogrids was developed. The developed system involves an online optimization scheme to adapt its parameters based on previous, current, and forecasted future system states. The communication requirements for all EMS modules were analyzed and are all integrated over a data distribution service (DDS) Ethernet network with appropriate quality of service (QoS) profiles. In conclusion, the developed EMS was emulated with actual residential energy consumption and irradiance data from Miami, Florida and proved its effectiveness in reducing consumers’ bills and achieving flat peak load profiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coordinated Scheduling for Interdependent Electric Power and Natural Gas Infrastructures

The extensive installation of gas-fired power plants in many parts of the world has led electric systems to depend heavily on reliable gas supplies. The use of gas-fired generators for peak load and reserve provision causes high intraday variability in withdrawals from high-pressure gas transmission systems. Such variability can lead to gas price fluctuations and supply disruptions that affect electric generator dispatch, electricity prices, and threaten the security of power systems and gas pipelines. These infrastructures function on vastly different spatio-temporal scales, which prevents current practices for separate operations and market clearing from being coordinated. Here in this article, we apply new techniques for control of dynamic gas flows on pipeline networks to examine day-ahead scheduling of electric generator dispatch and gas compressor operation for different levels of integration, spanning from separate forecasting, and simulation to combined optimal control. We formulate multiple coordination scenarios and develop tractable physically accurate computational implementations. These scenarios are compared using an integrated model of test networks for power and gas systems with 24 nodes and 24 pipes, respectively, which are coupled through gas-fired generators. The analysis quantifies the economic efficiency and security benefits of gas-electric coordination and dynamic gas system operation.

03 NATURAL GAS↗

Optimal Demand Response Incorporating Distribution LMP with PV Generation Uncertainty

The utilization of aggregated demand-side flexibility via demand response (DR) has become a promising pathway for the integration of renewable energy resources in power systems. Nowadays, there are several management strategies for DR such as the price-based transactive control strategies. However, many of such existing price-based control strategies neglect the physics and operational constraints of the underlying distribution networks when computing the price, raising concerns regarding their theoretical and practical values. This paper studies this issue and investigates optimal DR (ODR) by incorporating the distribution locational marginal price (DLMP). In particular, we discuss DR in connection with DLMPs and propose a multiperiod bilevel optimization problem to find the ODR strategy. Here, the objective is to minimize the peak load, load fluctuation, and payments of load aggregators. In addition, a robust bilevel ODR model is formulated to provide a robust ODR strategy while minimizing operating costs under the worst-case realization of uncertainties; this mitigates the impact of forecasting errors on renewable energy resources. Then, we propose an efficient solution approach by employing the Karush-Kuhn-Tucker conditions and strong duality. Simulation results are presented to illustrate the mutual impacts of the interaction between DR and DLMP and the benefits of the robust ODR strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Increasing Revenue of Nuclear Power Plants With Thermal Storage

Introducing large amounts of electricity produced from variable renewable energy sources such as wind and solar decreases wholesale electricity price while increasing the volatility of the market. These conditions drive the need for peak-load power generation, while regulation requirements fuel the push for flexible power generation. The increase of variable renewable energy in the market share, along with falling natural gas prices, makes nuclear power plants less competitive. Thermal storage is being considered to increase the nuclear power plant revenue. Thermal storage increases the flexibility of the nuclear plant system without sacrificing its efficiency. There are multiple opportunities to increase the nuclear power plant revenue, including increased capacity payments, arbitrage, and ancillary services. An economic analysis was performed to investigate the revenue increase of the system with thermal storage. The investment cost was assessed, and net present value was evaluated for the considered scenarios. Two system designs were considered in the analysis: a thermal storage system using the existing power conversion infrastructure and an integrated design with thermal storage fully incorporated into the reactor system design. The preliminary analysis showed that introducing a thermal storage system is profitable for some scenarios considered. Profitability depends significantly on the storage size, output flexibility, share of variable renewable energy, and market characteristics.

25 ENERGY STORAGE↗

Design of a Compact Dry Cooler With an Aluminum Heat Exchanger Core for a Supercritical CO2 Power Cycle Is Evaluated for a Concentrating Solar Power Application

Abstract As the supercritical CO2 power cycle develops and the component technologies mature, there is still a need to reduce the associated capital and operating costs to maintain a competitive levelized cost of electricity (LCOE) in order to enter the market. When considering concentrating solar power (CSP) coupled with an sCO2 power block and sensible thermal storage, the technology presents a clean source for utility-scale power generation to support baseload or peak-load electrical demand. However, the LCOE of the technology is still considered higher than the competing technologies and should be reduced to better compete in the market; 2030 targets for dispatchable solar plants are 5¢/kWh for baseload CSP and 10¢/kWh for peaker plants, as set by the United States Department of Energy. In response to this need, this study is targeting improvements in the power cycle precooler to reduce power block contribution to LCOE. This study considers a dry cooler, as CSP plants are sensitive to water consumption because many installations are slated for remote or arid locations where solar irradiance is very high, but water is scarce. Furthermore, the power block footprint for an sCO2 system is quite compact, especially as compared to a steam cycle. Therefore, there is interest in installing a more compact dry cooler that is proportional to the reduced footprint sCO2 power block, while conventional dry coolers are an order of magnitude larger. The competing goals of size, performance, and cost were considered in this study to develop a compact dry cooler that can easily be packaged with the power block, significantly reducing the installation and transport cost compared to the current state of the art, while maintaining or improving upon the heat transfer performance and impact on plant LCOE. This paper details the high-level findings of a large dry cooler sensitivity study for design point selection, design of the compact dry cooler, expected year-round performance for the dry cooler and the power cycle, and the predicted LCOE for a 30-year plant life. It was found that an aluminum heat exchanger core can be suitably designed to meet the pressure and temperature requirements for a precooler in an sCO2 recompression Brayton cycle. The dry cooler assembly was found to have improved heat transfer performance, allowing for increased cycle efficiencies and a reduced plant LCOE. When coupled with a centrifugal blower and compact transition duct, the dry cooler assembly was able to reduce the installation footprint by over 50%.

14 SOLAR ENERGY↗

Thermal Energy Storage Using Solid Particles for Long-Duration Energy Storage

The rapid growth of renewable energy increases the importance of economically firming the electricity supply from variable solar photovoltaic- and wind-power generators. Energy storage will be the key to manage variability and to bridge the generation gap over time scales of hours or days for high renewable grid integration. The integration of renewable power and storage of excess electricity has several significant and positive impacts including: 1) expanding the renewable energy portion of total electricity generation, 2) improving the peak-load response, and 3) coordinating the electricity supply and demand over the grid. Long-duration energy storage can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Several energy storage methods are deployed or under development, including mechanical, chemical or electrochemical, and thermal energy storage (TES). Comparing their economic potential for different scales and applications helps identify suitable technology to support high renewable grid integration. Despite the progress of TES technologies developed and deployed with concentrating solar power (CSP) systems, TES has been undervalued for its potential role in electric energy storage. This paper introduces TES methods applicable to grid energy storage and particularly focuses on solid-particle-based TES to serve the purpose of long-duration energy storage (LDES). The objective of this paper is to present a standalone particle-based TES system for electric storage and to show the potential of TES systems for LDES applications over other energy storage methods such as batteries, compressed-air energy storage, or pumped-storage hydropower.

27 ARPA - Advanced Research Projects Agency-Energy↗

Economic Analysis of an Electric Thermal Energy Storage System Using Solid Particles for Grid Electricity Storage

As renewable power generation becomes the mainstream new-built energy source, energy storage will become an indispensable need to complement the uncertainty of renewable resources to firm the power supply. When phasing out fossil-fuel power plants to meet the carbon neutral utility target in the midcentury around the world, large capacity of energy storage will be needed to provide reliable grid power. The renewable power integration with storage can support future carbon-free utility and has several significant impacts including increasing the value of renewable generation to the grid, improving the peak-load response, and balancing the electricity supply and demand. Long-duration energy storage (10–100 hours duration) can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system has promising cost and performance for the future growing energy storage needs. This paper introduces the system and components required for the particle TES to be technically and economically competitive. A technoeconomic analysis based on preliminary component designs and performance shows that the particle TES integrated with an efficient air-Brayton combined cycle power system can provide power for several days by low-cost, high-performance storage cycles. It addresses grid storage needs by enabling large-scale grid integration of intermittent renewables like wind and solar, thereby increasing their grid value. The design specifications and cost estimations of major components in a commercial scale system are presented in this paper. The cost model provides insights for further development and cost comparison with competing technologies.

27 ARPA - Advanced Research Projects Agency-Energy↗

PHASE CHANGE MATERIAL FOR THERMAL ENERGY STORAGE IN BUILDINGS BASED ON SODIUM SULFATE DECAHYDRATE AND DISODIUM HYDROGEN PHOSPHATE DODECAHYDRATE

The worldwide increasing energy demand and 2050 net zero carbon target urge the globe to solve the energy challenge. Thermal Energy Storage (TES) has received significant attention in recent years as TES can be integrated into heating, ventilation, and air-conditioning systems where the energy would be stored during low-demand times and dispatched during high-demand times, resulting in controlling the peak load and improving energy savings. Material development is an integral part of TES. Salt hydrates are appealing due to cost-effectiveness, low- to no toxicity, and their high melting enthalpy, where energy is stored as latent heat. However, most salt hydrates are prone to incongruent melting (i.e., phase separation upon melting), which results in poor stability and large supercooling. In this study, we produced a highly stable novel energy storage material at a composition of 32 wt% sodium sulfate decahydrate, 52 wt% sodium phosphate dibasic dodecahydrate, 12 wt% milled expanded graphite, and 4 wt% borax. The material has a melting temperature of 28°C and an energy storage capacity of 167 kJ/kg with a supercooling of less than 3°C. The system showed no loss in energy storage performance after 150 cycles. The findings suggest that the novel energy storage material developed in this might be utilized in building heating and cooling applications.

Turnaoglu, Tugba↗

Understanding the Elastic, Plastic, and Damage Features in Fracturing of Self-reinforced Thermoplastic Composites via Non-destructive Digital Imaging Correlation

This work demonstrated the utilization of non-destructive Digital Imaging Correlation (DIC) method to characterize the elastic, plastic, and damage features during the Mode I intra-laminar fracturing process of self-reinforced thermoplastic composites by using a self-reinforced polypropylene (PP) composite as an example. The DIC results clearly showed the development of huge plastic zone (PZ) and non-negligible Fracture Process Zone (FPZ) in front of the notch tip during the fracturing process, and the geometries and sizes of the foregoing zones at the peak load were further quantified. Such an interesting fracturing behavior of self-reinforced thermoplastic composites is way different from brittle materials (e.g., glass, acrylic, etc.), ductile materials (e.g., aluminum, steel, etc.), and even quasi-brittle materials (e.g., concrete, nanoparticle-reinforced composites, tough ceramics, wood, cement, carbon/glass fiber-reinforced polymers, etc.). Thus, understanding the elastic, plastic, and damage features is the first step before better characterizing the material fracture properties of self-reinforced thermoplastic composites through new analytical methods and computational modeling. These efforts are of utmost importance for wide applications of self-reinforced thermoplastic composites in various engineering fields in the future.

Lightweight Composites, Self-reinforced Thermoplas↗

Quantification of Energy Cost Savings through Optimization and Control of Appliances within Smart Neighborhood Homes

Electric utilities are driving towards enabling automatic scheduling and control of the consumption pattern of appliances such as heating, ventilation, and air conditioning (HVAC) and water heater (WH) systems (e.g., through preheating and pre-cooling, etc.) within smart neighborhoods to minimize energy cost and peak load demand. Quantifying economic savings through direct comparison of the optimized energy usage profile on a specific day with the typical non-optimized usage profile on another day is not a fair comparison because energy usage highly depends on weather conditions and human behaviour especially appliance like HVAC on those days. In this paper, we propose a novel approach of identifying similar weather day pairs which can then be used to compare the energy use profiles within homes between the identified pairs. We then demonstrate how the proposed approach can be used to compute cost savings due to optimization and control of smart appliances at home and neighborhood-level within a future-focused smart neighborhood of 62 residential homes. We also demonstrate a simulation based approach to quantify cost savings and showcase our findings through customized and interactive visualizations.

Chinthavali, Supriya↗

Why Do Electricity Policy and Competitive Markets Fail to Use Advanced PV Systems to Improve Distribution Power Quality?

The increasing pressure for network operators to meet distribution network power quality standards with increasing peak loads, renewable energy targets, and advances in automated distributed power electronics and communications is forcing policy-makers to understand new means to distribute costs and benefits within electricity markets. Discussions surrounding how distributed generation (DG) exhibits active voltage regulation and power factor/reactive power control and other power quality capabilities are complicated by uncertainties of baseline local distribution network power quality and to whom and how costs and benefits of improved electricity infrastructure will be allocated. DG providing ancillary services that dynamically respond to the network characteristics could lead to major network improvements. With proper market structures renewable energy systems could greatly improve power quality on distribution systems with nearly no additional cost to the grid operators. Renewable DG does have variability challenges, though this issue can be overcome with energy storage, forecasting, and advanced inverter functionality. This paper presents real data from a large-scale grid-connected PV array with large-scale storage and explores effective mitigation measures for PV system variability. We discuss useful inverter technical knowledge for policy-makers to mitigate ongoing inflation of electricity network tariff components by new DG interconnection requirements or electricity markets which value power quality and control.

14 SOLAR ENERGY↗