Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “panel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Buckling behavior of Rene 41 tubular panels for a hypersonic aircraft wing

The buckling characteristics of Rene 41 tubular panels for a hypersonic aircraft wing were investigated. The panels were repeatedly tested for buckling characteristics using a hypersonic wing test structure and a universal tension/compression testing machine. The nondestructive buckling tests were carried out under different combined load conditions and in different temperature environments. The force/stiffness technique was used to determine the buckling loads of the panel. In spite of some data scattering, resulting from large extrapolations of the data fitting curve (because of the termination of applied loads at relatively low percentages of the buckling loads), the overall test data correlate fairly well with theoretically predicted buckling interaction curves. Also, the structural efficiency of the tubular panels was found to be slightly higher than that of beaded panels.

Ko, W. L.↗

Buckling behavior of Rene 41 tubular panels for a hypersonic aircraft wing

The buckling characteristics of Rene 41 tubular panels for a hypersonic aircraft wing were investigated. The panels were repeatedly tested for buckling characteristics using a hypersonic wing test structure and a universal tension/compression testing machine. The nondestructive buckling tests were carried out under different combined load conditions and in different temperature environments. The force/stiffness technique was used to determine the buckling loads of the panels. In spite of some data scattering resulting from large extrapolations of the data-fitting curve (because of the termination of applied loads at relatively low percentages of the buckling loads), the overall test data correlate fairly well with theoretically predicted buckling interaction curves. Also, the structural efficiency of the tubular panels was found to be slightly higher than that of beaded panels.

Ko, W. L.↗

The effect on the transmission loss of a double wall panel of using helium gas in the gap

The possibility of increasing the sound-power transmission loss of a double panel by using helium gas in the gap is investigated. The transmission loss of a panel is defined as ten times the common logarithm of the ratio of the sound power incident on the panel to the sound power transmitted to the space on the other side of the panel. The work is associated with extensive research being done to develop new techniques for predicting the interior noise levels on board high-speed advanced turboprop aircraft and reducing the noise levels with a minimum weight penalty. Helium gas was chosen for its inert properties and its low impedance compared with air. With helium in the gap, the impedance mismatch experienced by the sound wave will be greater than that with air in the gap. It is seen that helium gas in the gap increases the transmission loss of the double panel over a wide range of frequencies.

Atwal, M. S.↗

Quick-Release Panel Fastener

Quick-release fastener for panels actuated with just one hand. Fastener has no loose parts, does not require mating hardware, and used in blind hole in mating panel. New panel fastener selfcontained unit extending through congruent holes in two panels to be joined. Unit contracts to clamp panels together and expands to release them.

Fosdick, D. R.↗

Optimization of aircraft interior panels

Eight different graphite composite panels were fabricated using four different resin matrices. The resin matrices included Hercules 71775, a blend of vinylpolystyrpyridine and bismaleimide, H795, a bismaleimide, Cycom 6162, a phenolic, and PSP 6022M, a polystyrylpyridine. Graphite panels were fabricated using fabric or unidirectional tape. This report describes the processes for preparing these panels and some of their mechanical, thermal and flammability properties. Panel properties are compared with state-of-the-art epoxy fiberglass composite panels.

Kourtides, Demetrius A.↗

Finite element prediction of aerothermal-structural interaction of aerodynamically heated panels

A finite element approach is used to study the aerothermal-structural interaction of aerodynamically heated panels. The Navier-Stokes equations for laminar compressible flow are solved together with the energy equation and quasi-static structural equations of the panel. Interactions between the flow, panel heat transfer and deformations are studied for a thin stainless steel panel aerodynamically heated by a Mach 6.6 flow and for a convectively cooled panel heated by a shock-boundary layer interaction.

Thornton, Earl A.↗

Fabrication and testing of fire resistant graphite composite panels

Eight different graphite composite panels were fabricated using four different resin matrices. The resin matrices included Hercules 71775, a blend of vinylpolystyrpyridine and bismaleimide, H795, a bismaleimide, Cycom 6162, a phenolic, and PSP 6022m, a polystyrylpyridine. Graphite panels were fabricated using fabric or unidirectional tape. Described are the processes for preparing these panels and some of their mechanical, thermal and flammability properties. Panel properties are compared with state-of-the-art epoxy fiberglass composite panels.

Roper, W. D.↗

Postbuckling of laminated anisotropic panels

A two-part study of the buckling and postbuckling of laminated anisotropic plates with bending-extensional coupling is presented. The first part involves the development and application of a modified Rayleigh-Ritz analysis technique. Modifications made to the classical technique can be grouped into three areas. First, known symmetries of anisotropic panels are exploited in the selection of approximation functions. Second, a reduced basis technique based on these same symmetries is applied in the linear range. Finally, geometric boundary conditions are enforced via an exterior penalty function approach, rather than relying on choice of approximation functions to satisfy these boundary conditions. Numerical results are presented for both the linear and nonlinear range, with additional studies made to determine the effect of variation in penalty parameter and number of basis vectors. In the second part, six panels possessing anisotropy and bending-extensional coupling are tested. Detailed comparisons are made between experiment and finite element results in order to gain insight into the postbuckling and failure characteristics of such panels. The panels are constructed using two different lamination sequences, and panels with three different aspect ratios were constructed for each lamination sequence.

Jeffrey, Glenda L.↗

Buckling characteristics of hypersonic aircraft wing tubular panels

The buckling characteristics of Rene 41 tubular panels installed as wing panels on a hypersonic wing test structure (HWTS) were determined nondestructively through use of a force/stiffness technique. The nondestructive buckling tests were carried out under different combined load conditions and different temperature environments. Two panels were subsequently tested to buckling failure in a universal tension compression testing machine. In spite of some data scattering because of large extrapolations of data points resulting from termination of the test at a somewhat low applied load, the overall test data correlated fairly well with theoretically predicted buckling interaction curves. The structural efficiency of the tubular panels was slightly higher than that of the beaded panels which they replaced.

Ko, William L.↗

Effects of fatigue and environment on residual strengths of center-cracked graphite/epoxy buffer strip panels

The effects of fatigue, moisture conditioning, and heating on the residual tension strengths of center-cracked graphite/epoxy buffer strip panels were evaluated using specimens made with T300/5208 graphite epoxy in a 16-ply quasi-isotropic layup, with two different buffer strip materials, Kevlar-49 or S-glass. It was found that, for panels subjected to fatigue loading, the residual strengths were not significantly affected by the fatigue loading, the number of repetitions of the loading spectrum, or the maximum strain level. The moisture conditioning reduced the residual strengths of the S-glass buffer strip panels by 10 to 15 percent below the ambient results, but increased the residual strengths of the Kevlar-49 buffer strip panels slightly. For both buffer strip materials, the heat increased the residual strengths of the buffer strip panels slightly over the ambient results.

Bigelow, Catherine A.↗

Superplastic forming/weld-brazing of Ti-6Al-4V panels for enhanced structural efficiency

An account is given of the results obtained by NASA-sponsored studies which exploit the processing advantages of superplastic forming (SPF) and joining by weld-brazing (WB) for the fabrication of Ti-alloy skin-stiffened structural components. The buckling strengths of panels with stiffeners having the geometry of a conventional hat shape are compared with those of panels having advanced-geometry stiffereners. Both single- and multiple-stiffened panels have been evaluated at room temperature; the SPF/WB panels with advanced-geometry stiffeners developed up to 60-percent higher buckling strength than panels with conventional-geometry stiffeners. Selective stiffener reinforcement with a boron-reinforced Al-matrix MMC was also evaluated.

Royster, Dick M.↗

Low temperature optical testing of CFRP telescope panels

Since 1984, low temperature optical tests were made of very lightweight mirror panels for use in balloon and space infrared and submillimeter telescopes. In order to accomplish this testing, an ambient pressure 0.5 meter test chamber operating from 20 to -80 C, developed techniques for measuring non-optical quality mirrors with phase modulation 10.6 micron interferometry, and created the interferogram reduction program. During the course of the program, nineteen mirrors from four manufactures were tested: carbon fiber reinforced plastic (CFRP) aluminum honeycomb sandwich panel mirrors, a CFRP sandwich panel with an added glass facesheet, and carbon fiber reinforced glass panels. The results of the panel development and test program are summarized.

Hoffmann, William F.↗

SiO overcoating and polishing of CFRP telescope panels

Development of carbon fiber reinforces plastic (CFRP) panel overcoating and polishing is structured in two parts. The first part utilized a short series of experiments to determine the feasibility of overcoating and polishing CFRP panels, and the second part employes a systematic approach to optimize techniques learned. Questions which required answers in the initial investigation are summarized. Tests were performedin the Steward Observatory's 2.2 Meter Vacuum Coating Chamber and began with 3 cm square pieces of CFRP facesheet material. Next, a 10 cm square and one-inch-thick CFPR-Aluminum core panel was tested. Tests were then conducted on a 0.5-meter-square Dornier panel (QUAD 4) with CFRP facesheets on two-inch aluminum Flexcore. To complete the initial study, a previously characterized 0.5 m Dornier panel (QUAD 23) was coated and hand polished. The mirror's optical performance was not affected by the SiO coating.

Woida, Patrick↗

Numerical and experimental simulations of the postbuckling response of laminated anisotropic panels

Numerical simulations are used in conjuction with experiments to study the buckling and postbuckling responses and failure initiation of flat unstiffened composite panels. The numerical simulations are conducted using two-dimensional shear-flexible finite elements. The effect of the laminate stacking sequence on the buckling and postbuckling responses is studied. Correlation between numerical and experimental results is good through buckling, but the numerical models overestimate the postbuckling stiffness of the panels. To explain the discrepancies in the postbuckling stiffnesses, analytic sensitivity derivatives are calculated and are used to study the sensitivity of the buckling and postbuckling responses to variations in different material and lamination parameters of the panel. Experimental results indicate that failure occurs along a nodal line. Numerical results show that the location of failure initiation corresponds to that of the maximum transverse shear strain energy density in the panel, which occurs at the edge of the panel at a nodal line.

Noor, Ahmed K.↗

Making Large Suction Panels For Laminar-Flow Control

Perforated titanium panels used to identify and resolve issues related to manufacture. Recently, relatively large suction panels with aerodynamically satisfactory surface perforations and with surface contours and smoothness characteristics necessary for Laminar-Flow Control (LFC) designed, fabricated, and tested. Requirements of production lines for commercial transport airplanes carefully considered in development of panels. Sizes of panels representative of what is used on wing of commercial transport airplane. Tests of perforated panels in transonic wind tunnel demonstrated aerodynamic stability at flight mach numbers.

Maddalon, Dal V.↗

Panel methods: An introduction

Panel methods are numerical schemes for solving (the Prandtl-Glauert equation) for linear, inviscid, irrotational flow about aircraft flying at subsonic or supersonic speeds. The tools at the panel-method user's disposal are (1) surface panels of source-doublet-vorticity distributions that can represent nearly arbitrary geometry, and (2) extremely versatile boundary condition capabilities that can frequently be used for creative modeling. Panel-method capabilities and limitations, basic concepts common to all panel-method codes, different choices that were made in the implementation of these concepts into working computer programs, and various modeling techniques involving boundary conditions, jump properties, and trailing wakes are discussed. An approach for extending the method to nonlinear transonic flow is also presented. Three appendices supplement the main test. In appendix 1, additional detail is provided on how the basic concepts are implemented into a specific computer program (PANAIR). In appendix 2, it is shown how to evaluate analytically the fundamental surface integral that arises in the expressions for influence-coefficients, and evaluate its jump property. In appendix 3, a simple example is used to illustrate the so-called finite part of the improper integrals.

Erickson, Larry L.↗

Large Deformation Behavior of Long Shallow Cylindrical Composite Panels

An exact solution is presented for the large deformation response of a simply supported orthotropic cylindrical panel subjected to a uniform line load along a cylinder generator. The cross section of the cylinder is circular and deformations up to the fully snapped through position are investigated. The orthotropic axes are parallel to the generator and circumferential directions. The governing equations are derived using laminated plate theory, nonlinear strain-displacement relations, and applying variational principles. The response is investigated for the case of a panel loaded exactly at midspan and for a panel with the load offset from midspan. The mathematical formulation is one dimensional in the circumferential coordinate. Solutions are obtained in closed-form. An experimental apparatus was designed to load the panels. Experimental results of displacement controlled tests performed on graphite-epoxy curved panels are compared with analytical predictions.

Carper, Douglas M.↗

Sound transmission loss of integrally damped, curved panels

Results are reported from acoustic transmission-loss measurements on 13 curved Al and composite aircraft-type panels (height 0.81 m, arc length 1.32 m, and curvature radius 2.29 m) without and with integral damping of various types. The fabrication of the panels and the test procedures are described and illustrated with photographs, and the results are presented in graphs. It is found that the loss of a curved panel exceeds the mass-law-predicted loss for a flat panel of the same material and thickness at frequencies below the ring frequency. At higher frequencies, the curved-panel loss is lower than the mass-law loss, being proportional to 20 time the log of thickness. Integral damping is found to be effective both below and above the ring frequency, but different mechanisms are responsible in each case.

Grosveld, Ferdinand W.↗