Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Fizeau wavemeter for pulsed laser wavelength measurement

A Fizeau wavelength meter optimized for use with pulsed laser sources has been developed and characterized which demonstrates a CW resolution better than 2 parts in 10 to the 7th and a pulsed resolution better than 1 part in 10 to the 6th. The static optical design is based on a Fizeau wedge interferometer, which together with spatial filtering and collimating optics is used to produce a pattern of parallel fringes which is imaged on a linear photodiode array and analyzed by a minicomputer. A series of CW and pulsed measurements of various narrowband laser sources are described, and particular difficulties involved in pulsed laser measurements with the wavemeter are examined.

Morris, M. B.↗

The Fringe Reading Facility at the Max-Planck-Institut fuer Stroemungsforschung

A Mach-Zehnder interferometer is used for optical flow measurements in a transonic wind tunnel. Holographic interferograms are reconstructed by illumination with a He-Ne-laser and viewed by a video camera through wide angle optics. This setup was used for investigating industrial double exposure holograms of truck tires in order to develop methods of automatic recognition of certain manufacturing faults. Automatic input is achieved by a transient recorder digitizing the output of a TV camera and transferring the digitized data to a PDP11-34. Interest centered around sequences of interferograms showing the interaction of vortices with a profile and subsequent emission of sound generated by this process. The objective is the extraction of quantitative data which relates to the emission of noise.

Becker, F.↗

Fiber optic electric field sensor technology

The properties of piezoactive plastics are reviewed as well as the fiber-optic electric field sensors studied so far. A particular configuration consisting of a concentric piezoactive jacket on the glass fiber is discussed in detail and the frequency response of this sensor is projected over a wide range of frequencies. The present design has the practical advantages of leading to a compact lightweight sensor; longer fiber lengths may be used to increase sensitivity. It is predicted that, at low frequencies, a fiber-optic antenna using a 1-km length of fiber would be capable of detecting a minimum electric field of 43 microV/m assuming a minimum phase sensitivity of 10 to the -6th radians for the optical Mach-Zehnder interferometer.

Jarzynski, J.↗

A figure control sensor for the Large Deployable Reflector (LDR)

A sensing and control system is required to maintain high optical figure quality in a segmented reflector. Upon detecting a deviation of the segmented surface from its ideal form, the system drives segment mounted actuators to realign the individual segments and thereby return the surface to its intended figure. When the reflector is in use, a set of figure sensors will determine positions of a number of points on the back surface of each of the reflector's segments, each sensor being assigned to a single point. By measuring the positional deviations of these points from previously established nominal values, the figure sensors provide the control system with the information required to maintain the reflector's optical figure. The optical lever, multiple wavelength interferometer, and electronic capacitive sensor, the most promising technologies for the development of the figure sensor, are illustrated. It is concluded that to select a particular implementation of the figure sensors, performance requirement will be refined and relevant technologies investigated further.

Bartman, R.↗

Analysis of cirrus optical properties with data from NASA ER2 High-resolution Interferometer Sounder (HIS)

The 8 to 13 micron spectral region is an important atmospheric window for radiometric studies of the Earth's surface and clouds. Most of the Earth-atmosphere longwave radiative loss to space occurs in this spectral region. Selective gaseous absorption in this window occurs in the 9.6 micron ozone band with the remaining absorption dominated by the water vapor continuum. Cirrus clouds have a large impact on the transmittance of this atmospheric window region; it is therefore important to understand the interaction of cirrus cloud with the radiation field for climate studies and in the interpretation of satellite radiometric measurements. The focus was to employ observations of the High-resolution Interferometer Sounder (HIS) made during First ISCCP Regional Experiment (FIRE) to improve the understanding of the radiative properties of cirrus clouds within this window region. Studies were undertaken to investigate the coupling between the microphysical properties of cirrus clouds and their spectral variation within this window region. Extensions of the HIS studies to satellite measurements, with regards to remote sensing and interpretation, were also investigated.

Smith, William L.↗

Hubble Space Telescope fine guidance sensor control system

The fine pointing information required for the extraordinary pointing stability of the Hubble Space Telescope (HST) is provided by the fine guidance sensor (FGS), which is capable of measuring extremely small pointing errors, of the order of 3 milliarcseconds. The FGS provides this fine pointing information over a relatively large, continuous range of angles of guide stars relative to the optical axis of the telescope. The FGS accomplishes this task by a judicious design involving the following: a two-axis high precision star selector servo system; an optical deflection system that provides high reduction from shaft angle to optical angle; a unique interferometer using Koester prisms and extremely sensitive photomultiplier tubes that enable the FGS to lock onto guide stars whose magnitude may be any value over a wide range of brightness (including 14.5 Mv and fainter); and the use the large aperture of the telescope itself to advantage. This paper describes the FGS control systems involved in achieving this performance, supported by test data.

Nurre, Gerald S.↗

Optical observations of close binaries with the Mark III Stellar Interferometer

For the first time, four spectroscopic binaries have been directly resolved with the Mark III Stellar Interferometer. Observations in 1988 and 1989 were analyzed, and visual orbits for four binaries have been determined. The semimajor axes for Beta Tri, Alpha Equ, Alpha And and Beta Ari are approximately 0.008 arcsec, 0.012 arcsec, 0.024 arcsec and 0.037 arcsec, respectively. The magnitude differences between two components are 0.5, 0.7, 1.8 and 2.6 mag, respectively. All of the orbital elements for Alpha And and Beta Ari were determined from interferometric data only, and agree well with spectroscopic observations. Predictions of relative position between the two components for these binaries are consistent with the measurements to less than 0.001 arcsec. Combined with data from spectroscopy, masses and distance for the double-lined spectroscopic binary Beta Ari are derived, and the results indicate that both components of Beta Ari agree well with the empirical mass-luminosity relation.

Pan, X. P.↗

Fiber optic smart structures and skins V; Proceedings of the Meeting, Boston, MA, Sept. 8, 9, 1992

The present conference discusses the materials used in applications of fiber-optics (F-O) to smart structures, extrinsic Fabry-Perot interferometric F-O sensors, sapphire F-O sensors, two-mode F-O sensors with photoinduced refractive index, an F-O accelerometer using two-mode fibers, and embedded F-O acoustic sensors for flaw detection. Also discussed are an optoelectronic smart structure interface, F-O sensors for simultaneous detection of strain and temperature, an optical Mach-Zehnder interferometer for smart skins, a split-cavity cross-coupled extrinsic fiber interferometer, and an embedded Bragg grating F-O sensor for composite flexbeams, an Er-doped ring-laser strain sensor.

Claus, Richard O.↗

Convective flow effects on protein crystal growth

The long-term stability of the interferometric setup for the monitoring of protein morphologies has been improved. Growth or dissolution of a crystal on a 100 A scale can now be clearly distinguished from dimensional changes occurring within the optical path of the interferometer. This capability of simultaneously monitoring the local interfacial displacement at several widely-spaced positions on the crystal surface with high local depth resolution, has already yielded novel results. We found with lysozyme that (1) the normal growth rate is oscillatory, and (2) the mean growth step density is greater at the periphery of a facet than in its center. The repartitioning of Na(+) and Cl(-) ions between lysozyme solutions and crystals was studied for a wide range of crystallization conditions. A nucleation-growth-repartitioning model was developed to interpret the large body of data in a unified way. The results strongly suggests that (1) the ion to lysozyme ratio in the crystal depends mostly on kinetic rather than crystallographic parameters, and (2) lysozyme crystals possess a salt-rich core with a diameter on the order of 10 microns. The computational model for diffusive-convective transport in protein crystallization (see the First Report) has been applied to a realistic growth cell geometry, taking into account the findings of the above repartitioning studies. These results show that some elements of a moving boundary problem must be incorporated into the model in order to obtain a more realistic description. Our experimental setup for light scattering investigations of aggregation and nucleation in protein solutions has been extensively tested. Scattering intensity measurements with a true Rayleigh scatterer produced systematically increased forward scattering, indicating problems with glare. These have been resolved. Preliminary measurements with supersaturated lysozyme solutions revealed that the scatterers grow with time. Work has begun on a computer program for the unified evaluation of simultaneously obtained, multi-angle static and dynamic light scattering data.

Rosenberger, Franz↗

Quantum Limits in Interferometric GW Antennas

We discuss a model for interferometric GW antennas illuminated by a laser beam and a vacuum squeezed field. The sensitivity of the antenna will depend on the properties of the radiation entering the two ports and on the optical characteristics of the interferometer components, e.g. mirrors, beam-splitter, lenses.

Romano, R.↗

Infrared Submillimeter and Radio Astronomy Research and Analysis Program

This program entitled "Infrared Submillimeter and Radio Astronomy Research and Analysis Program" with NASA-Ames Research Center (ARC) was proposed by the Smithsonian Astrophysical Observatory (SAO) to cover three years. Due to funding constraints only the first year installment of $18,436 was funded, but this funding was spread out over two years to try to maximize the benefit to the program. During the tenure of this contact, the investigators at the SAO, Drs. Wesley A. Traub and Nathaniel P. Carleton, worked with the investigators at ARC, Drs. Jesse Bregman and Fred Wittebom, on the following three main areas: 1. Rapid scanning SAO and ARC collaborated on purchasing and constructing a Rapid Scan Platform for the delay arm of the Infrared-Optical Telescope Array (IOTA) interferometer on Mt. Hopkins, Arizona. The Rapid Scan Platform was tested and improved by the addition of stiffening plates which eliminated a very small but noticeable bending of the metal platform at the micro-meter level. 2. Star tracking Bregman and Wittebom conducted a study of the IOTA CCD-based star tracker system, by constructing a device to simulate star motion having a specified frequency and amplitude of motion, and by examining the response of the tracker to this simulated star input. 3. Fringe tracking. ARC, and in particular Dr. Robert Mah, developed a fringe-packet tracking algorithm, based on data that Bregman and Witteborn obtained on IOTA. The algorithm was tested in the laboratory at ARC, and found to work well for both strong and weak fringes.

Traub, Wesley A.↗

Direct Imaging of Stellar Surfaces: Results from the Stellar Imager (SI) Vision Mission Study

The Stellar Imager (SI) is a UV-Optical, Space-Based Interferometer designed to enable 0.1 milli-arcsecond (mas) spectral imaging of stellar surfaces and stellar interiors (via asteroseismology) and of the Universe in general. SI is identified as a "Flagship and Landmark Discovery Mission'' in the 2005 Sun Solar System Connection (SSSC) Roadmap and as a candidate for a "Pathways to Life Observatory'' in the Exploration of the Universe Division (EUD) Roadmap (May, 2005). The ultra-sharp images of the Stellar Imager will revolutionize our view of many dynamic astrophysical processes: The 0.1 mas resolution of this deep-space telescope will transform point sources into extended sources, and snapshots into evolving views. SI's science focuses on the role of magnetism in the Universe, particularly on magnetic activity on the surfaces of stars like the Sun. SI's prime goal is to enable long-term forecasting of solar activity and the space weather that it drives in support of the Living With a Star program in the Exploration Era. SI will also revolutionize our understanding of the formation of planetary systems, of the habitability and climatology of distant planets, and of many magneto-hydrodynamically controlled processes in the Universe. In this paper we will discuss the results of the SI Vision Mission Study, elaborating on the science goals of the SI Mission and a mission architecture that could meet those goals.

Carpenter, Kenneth↗