Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “occupancy estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AW Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AW tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service-life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 23-25, 2016, on a slipstream from the AW exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

54 ENVIRONMENTAL SCIENCES↗

Monte Carlo mixture model of lifetime cancer incidence risk from radiation exposure on shuttle and international space station

Estimating uncertainty in lifetime cancer risk for human exposure to space radiation is a unique challenge. Conventional risk assessment with low-linear-energy-transfer (LET)-based risk from Japanese atomic bomb survivor studies may be inappropriate for relativistic protons and nuclei in space due to track structure effects. This paper develops a Monte Carlo mixture model (MCMM) for transferring additive, National Institutes of Health multiplicative, and multiplicative excess cancer incidence risks based on Japanese atomic bomb survivor data to determine excess incidence risk for various US astronaut exposure profiles. The MCMM serves as an anchor point for future risk projection methods involving biophysical models of DNA damage from space radiation. Lifetime incidence risks of radiation-induced cancer for the MCMM based on low-LET Japanese data for nonleukemia (all cancers except leukemia) were 2.77 (90% confidence limit, 0.75-11.34) for males exposed to 1 Sv at age 45 and 2.20 (90% confidence limit, 0.59-10.12) for males exposed at age 55. For females, mixture model risks for nonleukemia exposed separately to 1 Sv at ages of 45 and 55 were 2.98 (90% confidence limit, 0.90-11.70) and 2.44 (90% confidence limit, 0.70-10.30), respectively. Risks for high-LET 200 MeV protons (LET=0.45 keV/micrometer), 1 MeV alpha-particles (LET=100 keV/micrometer), and 600 MeV iron particles (LET=180 keV/micrometer) were scored on a per particle basis by determining the particle fluence required for an average of one particle per cell nucleus of area 100 micrometer(2). Lifetime risk per proton was 2.68x10(-2)% (90% confidence limit, 0.79x10(-3)%-0. 514x10(-2)%). For alpha-particles, lifetime risk was 14.2% (90% confidence limit, 2.5%-31.2%). Conversely, lifetime risk per iron particle was 23.7% (90% confidence limit, 4.5%-53.0%). Uncertainty in the DDREF for high-LET particles may be less than that for low-LET radiation because typically there is very little dose-rate dependence. Probability density functions for high-LET radiation quality and dose-rate may be preferable to conventional risk assessment approaches. Nuclear reactions and track structure effects in tissue may not be properly estimated by existing data using in vitro models for estimating RBEs. The method used here is being extended to estimate uncertainty in spacecraft shielding effectiveness in various space radiation environments.

NASA Center LaRC↗

Epidemiologic Studies of Radiation Workers - Paper 134

Studies of U.S. radiation workers are important because: (1) they provide information on the level of cancer and non-cancer risk following chronic exposure situations that are relevant today in medicine, occupation and environmental circumstances; (2) healthy U.S. workers are more similar to today's populations than Japanese 1945 atomic bomb survivors; (3) findings will be directly relevant to regulated worker populations; (4) organ-specific risk coefficients will be directly relevant to compensation programs; and (5) the dosimetric and epidemiologic findings can be integrated with the developing new understandings in biology for risk estimation for low doses and low dose rates. The ongoing Study of One Million U.S. Radiation Workers and Veterans is ten times larger than the study of the Japanese atomic bomb survivors of 86,000 survivors with estimated doses. The number of workers with > 100 mSv career dose is substantially greater. The large study size, broad range of doses and long follow-up indicates substantial statistical ability to quantify the risk of exposures that are received gradually over time. The study is designed to determine whether dose rate influences the future risk of cancer compared with the instantaneous exposure experienced by Japanese bomb survivors in 1945. This national effort is being coordinated by the NCRP and Vanderbilt University and includes collaborators within many government agencies (notably the DOE Low Dose Program, NRC, NASA and NCI), universities and the private sector. The study consists of 360,000 Department of Energy workers from the Manhattan Project, 150,000 nuclear utility workers from the inception of the nuclear age, 115,000 atomic veterans who participated in above ground atmospheric test at the Nevada Test Site and the Bikini Islands, 250,000 radiologists and medical workers, and 130,000 industrial radiographers. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

On the thermodynamic stability of hydrogen hydrates in the presence of promoter molecules

Cage occupancies of hydrogen molecules in a clathrate hydrate have been examined by means of semi-grand canonical Monte Carlo simulations where hydrogen molecules enter into or leave from it in the presence of promoter species. This kind of simulation allows to evaluate the thermodynamic stability via the chemical potential of water at a given temperature and pressure. In order to make a better estimation of the chemical potential, we adopt a different standard state from the corresponding empty one. It is revealed that the present method is indeed effective to minimize errors associated with the numerical simulations.

36 MATERIALS SCIENCE↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

General aviation crash safety program at Langley Research Center

The purpose of the crash safety program is to support development of the technology to define and demonstrate new structural concepts for improved crash safety and occupant survivability in general aviation aircraft. The program involves three basic areas of research: full-scale crash simulation testing, nonlinear structural analyses necessary to predict failure modes and collapse mechanisms of the vehicle, and evaluation of energy absorption concepts for specific component design. Both analytical and experimental methods are being used to develop expertise in these areas. Analyses include both simplified procedures for estimating energy absorption capabilities and more complex computer programs for analysis of general airframe response. Full-scale tests of typical structures as well as tests on structural components are being used to verify the analyses and to demonstrate improved design concepts.

Thomson, R. G.↗

Proposed biokinetic model for phosphorus

This paper reviews data related to the biokinetics of phosphorus in the human body and proposes a biokinetic model for systemic phosphorus for use in updated International Commission on Radiological Protection (ICRP) guidance on occupational intake of radionuclides. Compared with the ICRP s current occupational model for phosphorus (Publication 68, 1994) the proposed model provides a more realistic description of the paths of movement of phosphorus in the body and improved consistency with experimental, medical, and environmental data on the time-dependent distribution and retention of phosphorus following uptake to blood. For acute uptake of 32P to blood, the proposed model yields roughly a 50% decrease in dose estimates for bone surface and red marrow and a 6-fold increase in estimates for liver and kidney compared with the biokinetic model of Publication 68 (applying Publication 68 dosimetric models in both sets of calculations). For acute uptake of 33P to blood, the proposed model yields roughly a 50% increase in dose estimates for bone surface and red marrow and a 7-fold increase in estimates for liver and kidney compared with the model of Publication 68.

60 APPLIED LIFE SCIENCES↗

Prevalence of Self-Reported Voice Concerns and Associated Risk Markers in a Nonclinical Sample of Military Service Members

Introduction: Difficult communication environments are common in military settings, and effective voice use can be critical to mission success. This study aimed to estimate the prevalence of self-reported voice disorders among U.S. military service members and to identify factors that contribute to their voice concerns. Method: A nonclinical sample of 4,123 active-duty service members was recruited across Department of Defense hearing conservation clinics. During their required annual hearing evaluation, volunteers provided responses to voice-related questions including a slightly adapted version of the Voice Handicap Index-10 (VHI-10) as part of a larger survey about communication issues. Changepoint detection was applied to age and years of service to explore cohort effects in the reporting of voice concerns. Logistic regression analyses examined multiple available factors related to communication to identify factors associated with abnormal results on the VHI-10. Results: Among the respondents, 41% reported experiencing vocal hoarseness or fatigue at least several times per year, and 8.2% ( n = 336) scored above the recommended abnormal cut-point value of 11 on the VHI-10. Factors independently associated with the greatest risk for self-reported voice concerns were sex (female), cadmium exposure, vocal demands (the need for a strong, clear voice), and auditory health measures (frequency of experiencing temporary threshold shifts; self-reported hearing difficulties). Conclusions: Based on self-reported voice concerns and false negative rates reported in the literature, the prevalence of dysphonia in a large sample of active-duty service members is estimated to be 11.7%, which is higher than that in the general population. Certain predictors for voice concerns were expected based on previous literature, like female sex and voice use, but frequency of temporary threshold shifts and exposure to cadmium were surprising. The strong link between voice and auditory problems has particular implications regarding the need for effective communication in high-noise military and other occupational environments.

Audiology & Speech-Language Pathology↗

Alleviating prior dependencies for DESI DR1 clustering fits through reparameterization

Bayesian analyses of the full-shape clustering of Dark Energy Spectroscopic Instrument (DESI) Data Release 1 (DR1) exhibit prior-volume projection effects, whereby weakly constrained nuisance parameters of the Effective Field Theory of Large Scale Structure (EFTofLSS) shift marginalized cosmological posteriors away from the posterior maximum. We reanalyze DESI DR1 power spectrum multipoles using two complementary mitigation strategies: (i) nonlinear orthogonalization to decorrelate nuisance and cosmological parameter priors, and (ii) a fully reparameterization-invariant Jeffreys prior over all EFTofLSS coefficients, evaluated on-the-fly via closed-form Jacobians. Including data from DESI, Big-Bang Nuclesynthesis and a constraint on $n_{\mathrm{s}}$, baseline priors lead to multi-$σ$ projection in the Hubble parameter $H_{0}$ and dark energy equation of state parameters $w_{0}$ and $w_{a}$; the Jeffreys prior successfully recenters these posteriors to enclose the maximum a posteriori estimate within the 68% credible regions, demonstrating clear mitigation of projection effects for these late-time expansion parameters. A hybrid Jeffreys+baseline-Gaussian configuration controls residual over-broad tails in the physical cold dark matter density $ω_{\mathrm{c}}$ while preserving the volume correction, and is our favoured approach. We compare the credible intervals derived using our methodology to those obtained using Halo Occupation Distribution (HOD)-informed priors and to confidence intervals derived using frequentist profile likelihood analyses, finding agreement in both central values and degeneracy directions in the $w_{0}$--$w_{a}$ plane. This demonstrates that, once projection effects are properly controlled, we can make robust inferences about the late-time cosmological expansion independent of the statistical framework adopted.

Bonici, M. [Waterloo U.; Perimeter Inst. Theor. Ph↗

Load Flexibility Analysis of Residential HVAC and Water Heating and Commercial Refrigeration

The emergence of connected devices and the Internet of Things has opened the door to the concept of widespread use of building equipment for load-side flexibility. This stems from the increased use of distributed and clean energy resources for electric generation and the growing demand for a more resilient and reliable grid. A significant challenge associated with the use of building equipment as a distributed energy resource is quantifying the magnitude of power or energy flexibility. Unlike batteries that have well-defined and relatively constant capacity and maximum charge/discharge rates, building equipment often has characteristics that vary based on external factors (e.g., weather or occupant behavior). This makes quantifying the availability and flexibility of these resources difficult. Controlling a fleet of equipment while minimizing any adverse impacts to the occupants (e.g., discomfort or food spoilage) is a nontrivial matter. Although there are many different control methodologies available, this study focuses on two: priority-based control (PBC) and model-predictive control (MPC). These were selected because they represent two ends of the control spectrum. PBC is a relatively simple control strategy that requires only the current state of the devices to be controlled and an estimate of how much power each device consumes when turned on. MPC is much more complex and requires a model of the system and forecasts of any disturbances that influence the system. Because MPC has a predictive element, it can prepare for a desired response before the event and therefore is expected to provide a more optimal control relative to PBC. Both MPC and PBC are compared with a baseline simulation that uses feedback control typical of the thermostatically controlled devices being evaluated. This report investigates the load flexibility of three building systems: residential air conditioners, residential water heaters, and commercial refrigeration. Air heating and cooling and water heating account for 45% of residential electricity use, making them good candidates for providing load flexibility. Refrigeration in commercial buildings accounts for 16% of commercial building electricity use, making it another good candidate. Simplified models of each system were generated and validated based on measured data from actual equipment. These models were used to simulate the thermal and power response of the systems using PBC and MPC for a fleet of devices trying to achieve a variety of different responses, including hourly load shed, hourly load up, and daily peak demand reduction. Significant findings from each piece of equipment follow.

42 ENGINEERING↗

Hot gas in the interstellar medium: A reanalysis of O VI absorption data

The Copernicus O(+5) column densities toward 72 stars provide a rare and valuable tracer of 10(exp 5.5) K gas in the interstellar medium. The original analysis of the data by Jenkins provided important clues about the distribution of interstellar O(+5) ions, but our understanding of the local interstellar medium has since grown substantially. We revisit that work, including the possibility that local hot gas may contribute a significant O(+5) column density to most lines of sight. Our reanalysis also includes slight improvements in the statistics and was found to be reliable when tested on simulated data sets. In the end, we come to conclusions about the distribution of interstellar O(+5) ions that differ considerably from those of the original analysis. With our reanalysis, some theoretical models now show promise. For example, our Local Bubble column density compares favorably with the estimated quantity of O(+5) within the remnant of an ancient local explosion. Similarly, our mean O(+5) column density per feature in more distant regions is like that found in models of hot interstellar bubbles from either stellar winds or ancient supernova explosions in a warm diffuse interstellar environment, suggesting that the hot gas in interstellar space may exist primarily within discrete regions of modest volume occupation rather than in a continuous and pervasive phase.

Shelton, R. L.↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Nanoquartz in Late Permian C1 coal and the high incidence of female lung cancer in the Pearl River Origin area: a retrospective cohort study

Background: The Pearl River Origin area, Qujing District of Yunnan Province, has one of the highest female lung cancer mortality rates in China. Smoking was excluded as a cause of the lung cancer excess because almost all women were non-smokers. Crystalline silica embedded in the soot emissions from coal combustion was found to be associated with the lung cancer risk in a geographical correlation study. Lung cancer rates tend to be higher in places where the Late Permian C1 coal is produced. Therefore, we have hypothesized the two processes: C1 coal combustion --> nanoquartz in ambient air --> lung cancer excess in non-smoking women. Methods/Design: We propose to conduct a retrospective cohort study to test the hypothesis above. We will search historical records and compile an inventory of the coal mines in operation during 1930–2009. To estimate the study subjects' retrospective exposure, we will reconstruct the historical exposure scenario by burning the coal samples, collected from operating or deserted coal mines by coal geologists, in a traditional firepit of an old house. Indoor air particulate samples will be collected for nanoquartz and polycyclic aromatic hydrocarbons (PAHs) analyses. Bulk quartz content will be quantified by X-ray diffraction analysis. Size distribution of quartz will be examined by electron microscopes and by centrifugation techniques. Lifetime cumulative exposure to nanoquartz will be estimated for each subject. Using the epidemiology data, we will examine whether the use of C1 coal and the cumulative exposure to nanoquartz are associated with an elevated risk of lung cancer. Discussion: The high incidence rate of lung cancer in Xuan Wei, one of the counties in the current study area, was once attributed to high indoor air concentrations of PAHs. The research results have been cited for qualitative and quantitative cancer risk assessment of PAHs by the World Health Organization and other agencies. If nanoquartz is found to be the main underlying cause of the lung cancer epidemic in the study area, cancer potency estimates for PAHs by the international agencies based on the lung cancer data in this study setting should then be updated.

59 BASIC BIOLOGICAL SCIENCES↗

Audit Report on "The Department of Energy's Opportunity for Energy Savings Through the Use of Setbacks in its Facilities"

Our testing at Office of Science and National Nuclear Security Administration facilities revealed that the Department either did not use or failed to properly maintain setback systems and equipment in a number of instances. At just the four sites we visited, the Department had not ensured that setback conservation methods were used for 35 of the 55 (approximately 64 percent) owned or leased buildings included in our review. The buildings that did not use setbacks capabilities to control energy consumption comprised over one million square feet of space. Specifically: Although in place or capable of being deployed, officials did not utilize setbacks in 20 separate buildings; and, Equipment in 15 other buildings had either never been enabled or had deteriorated and was no longer functional, thus making setbacks impossible. Typical of the problems we noted, the Y-12 National Security Complex recently leased two buildings that were constructed with setback capability. The property manager for these buildings told us that the setback equipment was not used because the owner of the properties had not purchased the software necessary to enable the capability. In another case, we learned that Los Alamos National Laboratory was not using the setback capability in two buildings because facility operators and tenants had not been trained on operating the setback control system. Finally, the Oak Ridge National Laboratory lost the ability to operate the setback equipment in two buildings when the electronic control system failed in 2008. Laboratory officials told us that they elected not to replace it because they planned to implement campus-wide energy conservation measures in the future. In spite of its energy conservation leadership role, we found that the Department and its facility contractors did not place adequate emphasis on reducing energy consumption through the application of setbacks. Of particular significance, we found that the Department had not always required the operation of setback capabilities in building lease agreements. This was especially troubling given the expanded use of leased space to house Departmental operations. Despite discussions with several Federal and contractor officials, we could not obtain what we considered to be a satisfactory explanation as to why the Department failed to take advantage of this conservation practice, one that is generally low cost and has limited, if any, adverse impact on operations or building occupants. Consistent with the lack of emphasis in this area, we noted that the Department had not required the four contractors included in our review to develop training requirements or energy policies and procedures governing the use of setback capabilities. Energy consumption reduction goals related to setbacks had also not been established to help incentivize contractor performance in this important area. With nearly $300 million in annual utility costs, the Department could realize significant savings by using setbacks in its buildings. We estimate that the Department could save over $11.5 million in annual utility costs. We developed the estimate based on the observation that approximately 64 percent of the facilities included in our review had not used setbacks. We then conservatively applied a 15 percent energy consumption savings estimate observed by Sandia National Laboratory and savings estimates contained in a study conducted by Pacific Northwest National Laboratory to the 40 percent of utility costs generally recognized as resulting from HVAC operation. Such savings could be used to fund high priority programs and install additional energy saving features. The consumption savings would be, at today's average residential electricity cost, sufficient to power over 9,800 homes each year. We recognize that while setbacks can be used in many situations, they are not appropriate for facilities that are continuously operated or those that house delicate equipment that depend on constant temperatures. However, during the course of our audit officials at four of the sites included in our review told us that they recognized the utility of using setbacks for most facilities. At two sites, implementation efforts began almost immediately after we briefed officials on our findings. We also noted that Department Headquarters facilities used setbacks in offices and many common areas. With over 9,000 buildings in its inventory, the consistent use of setbacks can help the Department significantly reduce its energy consumption and, as noted above, achieve substantial cost savings. Actions related to setbacks that officials began after we initiated our audit are noteworthy and should, if fully implemented, help further reduce energy consumption. However, additional action at sites across the complex is necessary to maximize energy efficient operations and to establish the Department as the leader in this effort in all of the Federal sector.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Neutron diffraction study of magnetism in van der Waals layered MnBi 2n Te 3n+1

Two-dimensional van der Waals MnBi 2 n Te 3 n +1 ( n = 1, 2, 3, 4) compounds have been recently found to be intrinsic magnetic topological insulators rendering quantum anomalous Hall effect and diverse topological states. Here, we summarize and compare the crystal and magnetic structures of this family, and discuss the effects of chemical composition on their magnetism. We found that a considerable fraction of Bi occupies at the Mn sites in MnBi 2 n Te 3 n +1 ( n = 1, 2, 3, 4) while there is no detectable Mn at the non-magnetic atomic sites within the resolution of neutron diffraction experiments. The occupancy of Mn monotonically decreases with the increase of n . The polarized neutron diffraction on the representative MnBi 4 Te 7 reveals that its magnetization density is exclusively accumulated at the Mn site, in good agreement with the results from the unpolarized neutron diffraction. The defects of Bi at the Mn site naturally explain the continuously reduced saturated magnetic moments from n = 1 to n = 4. The experimentally estimated critical exponents of all the compounds generally suggest a three-dimensional character of magnetism. Our work provides material-specified structural parameters that may be useful for band structure calculations to understand the observed topological surface states and for designing quantum magnetic materials through chemical doping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The galaxy–halo connection of emission-line galaxies in IllustrisTNG

ABSTRACT We employ the hydrodynamical simulation IllustrisTNG-300-1 to explore the halo occupation distribution (HOD) and environmental dependence of luminous star-forming emission-line galaxies (ELGs) at z ∼ 1. Such galaxies are key targets for current and upcoming cosmological surveys. We select model galaxies through cuts in colour–colour space allowing for a direct comparison with the Extended Baryon Oscillation Spectroscopic Survey and the Dark Energy Spectroscopic Instrument (DESI) surveys and then compare them with galaxies selected based on specific star formation rate (sSFR) and stellar mass. We demonstrate that the ELG populations are twice more likely to reside in lower density regions (sheets) compared with the mass-selected populations and twice less likely to occupy the densest regions of the cosmic web (knots). We also show that the colour-selected and sSFR-selected ELGs exhibit very similar occupation and clustering statistics, finding that the agreement is best for lower redshifts. In contrast with the mass-selected sample, the occupation of haloes by a central ELG peaks at ∼20 per cent. We furthermore explore the dependence of the HOD and the autocorrelation on environment, noticing that at fixed halo mass, galaxies in high-density regions cluster about 10 times more strongly than low-density ones. This result suggests that we should model carefully the galaxy–halo relation and implement assembly bias effects into our models (estimated at ∼4 per cent of the clustering of the DESI colour-selected sample at z = 0.8). Finally, we apply a simple mock recipe to recover the clustering on large scales (r ≳ 1 Mpc h−1) to within 1 per cent by augmenting the HOD model with an environment dependence, demonstrating the power of adopting flexible population models.

79 ASTRONOMY AND ASTROPHYSICS↗

Sparse expansions of multicomponent oxide configuration energy using coherency and redundancy

We report that compressed sensing has become a widely accepted paradigm to construct high dimensional cluster expansion models used for statistical mechanical studies of atomic configuration in complex multicomponent crystalline materials. However, strict sampling requirements necessary to obtain minimal coherence measurements for compressed sensing to guarantee accurate estimation of model parameters are difficult and in some cases impossible to satisfy due to the inability of physical systems to access certain configurations. Nevertheless, the dependence of energy on atomic configuration can still be adequately learned without these strict requirements by using compressed sensing by way of coherent measurements using redundant function sets known as frames. We develop a particular frame constructed from the union of all occupancy-based cluster expansion basis sets. We illustrate how using this highly redundant frame yields sparse expansions of the configuration energy of complex oxide materials that are competitive and often surpass the prediction accuracy and sparsity of models obtained from standard cluster expansions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗