Gamma ray spectroscopy employing divalent europium-doped alkaline earth halides and digital readout for accurate histogramming

A scintillator radiation detector system according to one embodiment includes a scintillator; and a processing device for processing pulse traces corresponding to light pulses from the scintillator, wherein pulse digitization is used to improve energy resolution of the system. A scintillator radiation detector system according to another embodiment includes a processing device for fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times and performing a direct integration of fit parameters. A method according to yet another embodiment includes processing pulse traces corresponding to light pulses from a scintillator, wherein pulse digitization is used to improve energy resolution of the system. A method in a further embodiment includes fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times; and performing a direct integration of fit parameters. Additional systems and methods are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A positron trap and beam apparatus for atomic and molecular scattering experiments

An instrument has been designed and constructed to provide new insights into fundamental, low energy positron scattering processes. The design is based on the Surko trap system and produces a pulsed positron beam with an energy resolution of as good as 54 meV. The design and operation of the apparatus is explained, while the first experimental results from this apparatus have been demonstrated in recent publications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Web-based, GPU-accelerated, Monte Carlo simulation and visualization of indirect radiation imaging detector performance

Purpose: Monte Carlo simulations play a vital role in the understanding of the fundamental limitations, design, and optimization of existing and emerging medical imaging systems. Efforts in this area have resulted in the development of a wide variety of open-source software packages. One such package, hybridMANTIS, uses a novel hybrid concept to model indirect scintillator detectors by balancing the computational load using dual CPU and graphics processing unit (GPU) processors, obtaining computational efficiency with reasonable accuracy. In this work, the authors describe two open-source visualization interfaces, webMANTIS and visualMANTIS to facilitate the setup of computational experiments via hybridMANTIS. Methods: The visualization tools visualMANTIS and webMANTIS enable the user to control simulation properties through a user interface. In the case of webMANTIS, control via a web browser allows access through mobile devices such as smartphones or tablets. webMANTIS acts as a server back-end and communicates with an NVIDIA GPU computing cluster that can support multiuser environments where users can execute different experiments in parallel. Results: The output consists of point response and pulse-height spectrum, and optical transport statistics generated by hybridMANTIS. The users can download the output images and statistics through a zip file for future reference. In addition, webMANTIS provides a visualization window that displays a few selected optical photon path as they get transported through the detector columns and allows the user to trace the history of the optical photons. Conclusions: The visualization tools visualMANTIS and webMANTIS provide features such as on the fly generation of pulse-height spectra and response functions for microcolumnar x-ray imagers while allowing users to save simulation parameters and results from prior experiments. The graphical interfaces simplify the simulation setup and allow the user to go directly from specifying input parameters to receiving visual feedback for the model predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast energy redistribution in C{sub 60} fullerenes: A real time study by two-color femtosecond spectroscopy

Strong-field excitation and energy redistribution dynamics of C{sub 60} fullerenes are studied by means of time-resolved mass spectrometry in a two-color femtosecond pump-probe setup. Resonant pre-excitation of the electronic system via the first dipole-allowed HOMO{yields}LUMO+1(t{sub 1g}) (HOMO denotes highest occupied molecular orbital and LUMO denotes lowest unoccupied molecular orbital) transition with ultrashort 25 fs pulses at 399 nm of some 10{sup 12} W cm{sup -2} results in a highly nonequilibrium distribution of excited electrons and vibrational modes in the neutral species. The subsequent coupling among the electronic and nuclear degrees of freedom is monitored by probing the system with time-delayed 27 fs pulses at 797 nm of some 10{sup 13} W cm{sup -2}. Direct information on the characteristic relaxation time is derived from the analysis of transient singly and multiply charged parent and fragment ion signals as a function of pump-probe delay and laser pulse intensity. The observed relaxation times {tau}{sub el}{approx_equal}60-400 fs are attributed to different microcanonical ensembles prepared in the pre-excitation process and correspond to different total energy contents and energy sharing between electronic and vibrational degrees. The characteristic differences and trends allow one to extract a consistent picture for the formation dynamics of ions in different charge states and their fullerenelike fragments and give evidence to collective effects in multiple ionization such as plasmon-enhanced energy deposition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ceramic Plugs for Deep Borehole Seals - 17316

In the deep borehole nuclear waste disposal concept, waste packages are emplaced deep in crystalline rock formations under conditions of high pressures, high mineral content water, and elevated temperatures. Well seals and plugs must perform for thousands of years. A novel ceramic plug system under development capitalizes on the thermal energy of thermite mixtures and engineered additives to react and form ceramic-like plugs in place with favorable structural, flow, and geochemical properties. Depending on the ingredients, the reaction can produce aluminosilicates, plagioclase feldspars, or other combinations in crystalline or amorphous forms. Normative mineralogy techniques were applied to predict product mineralogy and evaluate compatibility with host rocks, and showed they are comparable to igneous rock analogs. The results support a tentative geochemical compatibility between these formulations and granitic host rock. Because the reaction produces a significant amount of thermal energy, the thermal/structural/fluid response of the plug and surrounding media was evaluated with the FEHM code. Temperatures near the plug/rock interface are estimated to peak at less than 600 deg. C and cool to near ambient temperature within a day. Rock stresses resulting from the thermal pulse are predicted to be similar to the unconfined compressive strength of granites, and generally lower than triaxial test results. Entrained fluid expansion due to heating was shown to be lower than failure stresses. Little or no failure in the surrounding media would be expected due to the plug formation process. The present efforts are focused on refining the material formulations, evaluating the geochemical and mechanical interactions between the plug and host rock, and testing the plug formation process in scaled granite and basalt masses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nanosecond-resolved temperature measurements using magnetic nanoparticles

Instantaneous and noninvasive temperature measurements are important when laser thermotherapy or welding is performed. A noninvasive nanosecond-resolved magnetic nanoparticle (MNP) temperature measurement system is described in which a transient change in temperature causes an instantaneous change in the magnetic susceptibilities of the MNPs. These transient changes in the magnetic susceptibilities are rapidly recorded using a wideband magnetic measurement system with an upper frequency limit of 0.5 GHz. The Langevin function (the thermodynamic model characterizing the MNP magnetization process) is used to obtain the temperature information. Experiments showed that the MNP DC magnetization temperature-measurement system can detect a 14.4 ns laser pulse at least. This method of measuring temperature is likely to be useful for acquiring the internal temperatures of materials irradiated with lasers, as well as in other areas of research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixel response characterization of the ARCADIA fully depleted MAPS

Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a 55 Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.

Particle tracking detectors↗

Laser-based Adhesion Strength Measurements for Advanced Manufactured Sensor Adhesion Characterization

As part of the advanced manufacturing (AM) focus of the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) Program, new in-house capabilities to fabricate and test novel active and passive in-pile sensors are being developed at the Idaho National Laboratory (INL). These advanced-manufactured sensors, such as peak temperature monitors and strain gauges, must be miniaturized and be able to provide real-time feedback, all while withstanding the coupled extremes of temperature and radiation typically observed in the environment of a nuclear test reactor. Fabricating durable and robust in-pile sensors with high fidelity requires a fundamental understanding of the optimal process parameters required in the AM technique, as well as the effect of deviations from optimal process parameters on the sensor-substrate adhesion and the ultimate robustness of the sensor. This report presents the use of a laser-based, non-contact approach for characterizing the adhesion of sensors manufactured using aerosol jet printing (AJP) that comprise of silver nanoparticle inks deposited and sintered on austenitic stainless steel (SS) 316L substrates. The effect of substrate surface roughness, surface energy, ink sintering time and sintering temperature on the printed sensor topography and the sensor-substrate adhesion has been systematically investigated. The sensor-substrate interfacial adhesion strength was determined from the critical laser pulse energy required to ablate/ detach the printed sensor from the substrate. Measurements of the sensor topography using optical profilometry revealed that post-deposition sintering at 400°C for 60 minutes resulted in a reduced sensor thickness, while plasma treating the substrate prior to printing yielded sensors with uniform thickness profiles transverse to the print direction. Sintering temperature and time were found to be the dominant parameters that affected sensor-substrate adhesion, followed by substrate surface roughness. The laser-based and locally-destructive approach for adhesion strength measurements shows promise in overcoming the challenges and limitations of current standardized peel tests and can be developed into a post-fabrication process control protocol for evaluating the durability of AM printed sensors in a high throughput fashion. Future studies will investigate the use of laser-induced spallation techniques as well as non-destructive laser ultrasonic methods for sensor-substrate adhesion characterization on sensors manufactured using AJP and other AM techniques such as plasma jet printing (PJP).

42 ENGINEERING↗

Magnetostrictive Ultrasonic Waveguide Transducer for In-Pile Thermometry

Real-time and reliable temperature measurement on nuclear fuels is crucial for the safe operation of existing pressurized-water reactors and future advanced nuclear reactors. Magnetostrictive materials deform when subjected to a magnetic field or exhibit magnetization variation when stressed. Here, based on these properties, this study prototyped an ultrasonic thermometer (UT) consisting of a magnetostrictive waveguide, a dc coil providing appropriate magnetic biasing, and an ac coil generating an acoustic impulse and detecting the resulting acoustic echoes. By tracking the time of flight between the excitation pulse and the echoes, the UT can potentially detect nuclear fuel cladding temperature from a long distance. In this study, magnetostrictive iron–gallium alloys, or Galfenol, were selected as the waveguide due to their large magnetostriction, superior temperature survivability, excellent radiation resilience, and high mechanical robustness. A multiphysics finite-element model considering electrical, magnetic, and mechanical dynamics in the magnetostrictive UT was then developed. The model exhibited an error of 0.24% in time-of-flight simulation and, therefore, enabled computer-aided design and guided signal processing. Between room temperature and 120 °C, the new Galfenol-based UT exhibits a linear sensitivity of 162.8×10 ₋6 °C ₋1 , which is 51.7% higher than a previous magnetostrictive UT based on iron–cobalt–vanadium alloys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Performance/-Precision/-Z(HPPZ) Scintillator Grids via Advanced Electrochemistry. Phase I – Project # 20210572MFR- Mid year review [Slides]

Scintillation grids with improved imaging resolution in time and space, are required for future mission needs at various facilities (pRad user station, LANSCE, DARHT, Scorpius etc). Current technologies use inorganic crystal scintillators, which are positioned within a high-Z scintillator septa. Dense and high-Z materials are optimal for gamma-ray detection making them promising candidates for development of high -performance/-precision/-Z (HPPZ) scintillator grids. The current resolution of standard chemical etching and fabrication processes of high-Z materials is very low, leading to undesired undercutting and ultimately reducing crystal performance efficiency. Goals are to: Perform initial feasibility studies with the aim of producing complex parts for applications with difficult-to-process high-Z material; Use of pulse and pulse-reverse electrochemical methods on additive approaches to produce high-precision Au and Re scintillator grids at a small scale; and, Follow up in Phase II with the delivery of a large-scale scintillator grid of the best material candidate with unprecedented properties for LANL needs determined in Phase I.

36 MATERIALS SCIENCE↗

Generation of ultra-short THz pulses in new optical nonlinear materials based on organic polymers

Using the method of optical rectification of femtosecond laser pulses, we report the generation of short (a few field cycles) terahertz pulses in the samples of films based on polyimides with covalently bound chromophore molecules of DR type. The spectral width of the produced pulses is limited by the pump pulse duration. The quadratic nonlinear optical properties are imparted to the films in the process of their fabrication by orienting the chromophore molecules in the external electric field of the applied electrodes having an original configuration. The samples are compared with the ZnTe crystal. Using the methods of coherent spectroscopy, their transmission and refractive index dispersion spectra are investigated in the frequency range 0.5 – 2.6 THz. The studied polymer composition is promising for the application in coherent spectrometers both for increasing the working spectral range without dips and for improving the spatial resolution in the near-field terahertz spectroscopy. (nonlinear optical phenomena)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-Optical Radiation Reaction at 1 0 21 W / cm 2

By using full-scale 3D particle-in-cell simulations we show that the radiation reaction dominated regime can be reached in an all optical configuration through the collision of a ~1 GeV laser wakefield accelerated (LWFA) electron bunch with a counter propagating laser pulse. In this configuration radiation reaction significantly reduces the energy of the particle bunch, thus providing clear experimental signatures for the process with currently available lasers. We also show that the transition between classical and quantum radiation reaction could be investigated in the same configuration with laser intensities of 10 24 W/cm 2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Morphology effects on spin-dependent transport and recombination in polyfluorene thin films

Here, we have studied the role of spin-dependent processes on conductivity in polyfluorene (PFO) thin films by preforming continuous wave (cw) electrically detected magnetic resonance (EDMR) spectroscopy at temperatures between 10 K and room temperature using microwave frequencies between about 1 GHz and 20 GHz, as well as pulsed EDMR at the X band (10 GHz). Variable frequency EDMR allows us to establish the role of spin-orbit coupling in spin-dependent processes whereas pulsed EDMR allows for the observation of coherent spin motion effects. We used PFO for this study in order to allow for the investigation of the effects of microscopic morphological ordering since this material can adopt two distinct intrachain morphologies: an amorphous (glassy) phase, in which monomer units are twisted with respect to each other, and an ordered (β) phase, where all monomers lie within one plane. In thin films of organic light-emitting diodes, the appearance of a particular phase can be controlled by deposition parameters and solvent vapor annealing, and is verified by electroluminescence spectroscopy. Under bipolar charge-carrier injection conditions, we conducted multifrequency cw EDMR, electrically detected Rabi spin-beat experiments, and Hahn echo and inversion-recovery measurements. Coherent echo spectroscopy reveals electrically detected electron-spin-echo envelope modulation due to the coupling of the carrier spins to nearby nuclear spins. Our results demonstrate that, while conformational disorder can influence the observed EDMR signals, including the sign of the current changes on resonance as well as the magnitudes of local hyperfine fields and charge-carrier spin-orbit interactions, it does not qualitatively affect the nature of spin-dependent transitions in this material. In both morphologies, we observe the presence of at least two different spin-dependent recombination processes. At room temperature and 10 K, polaron-pair recombination through weakly spin-spin coupled intermediate charge-carrier pair states is dominant, while at low temperatures, additional signatures of spin-dependent charge transport through the interaction of polarons with triplet excitons are seen in the half-field resonance of a triplet spin-1 species. This additional contribution arises since triplet lifetimes are increased at lower temperatures. We tentatively conclude that spectral broadening induced by hyperfine coupling is slightly weaker in the more ordered β-phase than in the glassy phase since protons are more evenly spaced, whereas broadening effects due to spin-orbit coupling, which impacts the distribution of g-factors, appear to be somewhat more significant in the β-phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reduction of ablated surface expansion in pulsed-power-driven experiments using an aerosol dielectric coating

The quality of warm dense matter samples created by magnetic compression can be largely affected by material ablation. When the ablated material carries currents, local instabilities can grow, which can lead to nonuniformities in the final magnetic pressure. Extending the previous work by Peterson et al., Awe et al., and Hutchison et al., the experiments reported here demonstrate that the expansion of the ablated material can be significantly reduced by using a simple aerosol spray technique. Coating the current-carrying surfaces with a 30–60-μm layer of polyurethane reduced the expansion of the ablated material by a factor of 2 and eliminated material ejections from sharp corners. Here, this technique, tested at the Michigan Accelerator for Inductive Z-Pinch Experiments pulsed power facility at the University of Michigan with currents up to 400 kA, could allow the production of homogeneous warm dense matter samples on pulsed-power drivers. Because of the simplicity of this method, this work brings forth an important contribution to pulsed-power-driven experiments designed to study nuclear fusion, material properties, and radiation science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast branching in intersystem crossing dynamics revealed by coherent vibrational wavepacket motions in a bimetallic Pt($\mathrm{II}$) complex

Ultrafast excited-state processes of transition metal complexes (TMCs) are governed by complicated interplays between electronic and nuclear dynamics, which demand a detailed understanding to achieve optimal functionalities of photoactive TMC-based materials for many applications. Here, in this work, we investigated a cyclometalated platinum(II) dimer known to undergo a Pt-Pt bond contraction in metal-metal-to-ligand-charge-transfer (MMLCT) excited state using femtosecond broadband transient absorption (fs-BBTA) spectroscopy in combination with geometry optimization and normal mode calculations. Using sub-20 fs pump and broadband probe pulses in fs-BBTA spectroscopy, we are able to correlate coherent vibrational wavepacket (CVWP) evolution with stimulated emission (SE) dynamics of the 1 MMLCT state. The results demonstrated that the 145 cm -1 CVWP motions with the damping times of ~ 0.9 ps and ~ 2 ps originate from coherent Pt-Pt stretching vibrations in the singlet and triplet MMLCT states, respectively. On the basis of excited-state potential energy surface calculations in our previous work, we rationalized that the CVWP transfer from Franck-Condon (FC) state to the 3 MMLCT state was mediated by a triplet ligand-centered ( 3 LC) intermediate state through two step intersystem crossing (ISC) on a time scale shorter than a period of the Pt-Pt stretching wavepacket motions. Moreover, it was found that the CVWP motion with 110 cm-1 frequency decays with the damping time of ~ 0.2 ps, well matching the time constant of 0.253 ps corresponding to a redshift in the SE feature at early time. This observation indicates that the Pt-Pt bond contraction changes the stretching frequency from 110 to 145 cm -1 and stabilize the 1 MMLCT state relative to the 3 LC state with the ~ 0.2 ps time scale. Thus, the ultrafast ISC from the 1 MMLCT to the 3 LC states occurs before the Pt-Pt bond shortening. The findings herein provide insight into understanding the impact of Pt-Pt bond contraction on ultrafast branching of the 1 MMLCT population into the direct ( 1 MMLCT → 3 MMLCT) and indirect ISC pathways ( 1 MMLCT → 3 LC → 3 MMLCT) in the Pt(II) dimer. These results revealed intricate excited state electronic and nuclear motions that could steer the reaction pathways with levels of details that have not achieved before

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Signal processing to reduce dark noise impact in precision timing

We introduce a technique to mitigate the effects of low frequency noise on precision timing. The example of Dark Count Noise Rate (DCR) in Silicon Photomultipliers (SiPMs) is emphasized. This technique exploits the correlation between time shifts on the leading edge of a signal and the residual slope of the baseline (due to noise) which remains after baseline subtraction. In fast timing applications (such as for Time-of-flight particle ID) the signal arrival time is typically captured on the signal leading edge. The signal risetime is often fixed by the physics of the sensor and input circuit. Then accurate pulse timing can be achieved by correcting a leading edge threshold time (depending on a slope proportional to both the Amplitude and the risetime) to a “constant fraction” time. This compensation for time walk due to amplitude fluctuations breaks down once we introduce interference from low frequency noise on the leading edge. In this paper we demonstrate that an additional measurement of the slope at threshold can be used to correct for this noise jitter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applying the new gamma ray imager diagnostic to measurements of runaway electron Bremsstrahlung radiation in the DIII-D Tokamak (invited)

A new gamma ray imager (GRI) is developed to probe the electron distribution function with 2D spatial resolution during runaway electron (RE) experiments at the DIII-D tokamak. The diagnostic is sensitive to 0.5–100 MeV gamma rays, allowing characterization of the RE distribution function evolution during RE growth and dissipation. The GRI consists of a lead “pinhole camera” mounted on the DIII-D midplane with 123 honeycombed tangential chords 20 cm wide that span the vessel interior. Up to 30 bismuth germanate (BGO) scintillation detectors capture RE bremsstrahlung radiation for Pulse Height Analysis (PHA) capable of discriminating up to 20 000 pulses per second. Digital signal processing routines combining shaping filters are performed during PHA to reject noise and record gamma ray energy. The GRI setup and PHA algorithms will be described and initial data from experiments will be presented. A synthetic diagnostic is developed to generate the gamma ray spectrum of a GRI channel given the plasma information and a prescribed distribution function. Magnetic reconstructions of the plasma are used to calculate the angle between every GRI sightline and orient and discriminate gamma rays emitted by a field-aligned RE distribution function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First on-line detection of radioactive fission isotopes produced by laser-accelerated protons

Abstract The on-going developments in laser acceleration of protons and light ions, as well as the production of strong bursts of neutrons and multi- $$\hbox {MeV}$$ MeV photons by secondary processes now provide a basis for novel high-flux nuclear physics experiments. While the maximum energy of protons resulting from Target Normal Sheath Acceleration is presently still limited to around $$100 \, \hbox {MeV}$$ 100 MeV , the generated proton peak flux within the short laser-accelerated bunches can already today exceed the values achievable at the most advanced conventional accelerators by orders of magnitude. This paper consists of two parts covering the scientific motivation and relevance of such experiments and a first proof-of-principle demonstration. In the presented experiment pulses of $$200 \, \hbox {J}$$ 200 J at $$\approx \, 500 \, \hbox {fs}$$ ≈ 500 fs duration from the PHELIX laser produced more than $$10^{12}$$ 10 12 protons with energies above $$15 \, \hbox {MeV}$$ 15 MeV in a bunch of sub-nanosecond duration. They were used to induce fission in foil targets made of natural uranium. To make use of the nonpareil flux, these targets have to be very close to the laser acceleration source, since the particle density within the bunch is strongly affected by Coulomb explosion and the velocity differences between ions of different energy. The main challenge for nuclear detection with high-purity germanium detectors is given by the strong electromagnetic pulse caused by the laser-matter interaction close to the laser acceleration source. This was mitigated by utilizing fast transport of the fission products by a gas flow to a carbon filter, where the $$\upgamma$$ γ -rays were registered. The identified nuclides include those that have half-lives down to $$39 \, \hbox {s}$$ 39 s . These results demonstrate the capability to produce, extract, and detect short-lived reaction products under the demanding experimental condition imposed by the high-power laser interaction. The approach promotes research towards relevant nuclear astrophysical studies at conditions currently only accessible at nuclear high energy density laser facilities.

07 ISOTOPE AND RADIATION SOURCES↗