Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measured data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Stackfile Database

This software provides storage retrieval and analysis functionality for managing satellite altimetry data. It improves the efficiency and analysis capabilities of existing database software with improved flexibility and documentation. It offers flexibility in the type of data that can be stored. There is efficient retrieval either across the spatial domain or the time domain. Built-in analysis tools are provided for frequently performed altimetry tasks. This software package is used for storing and manipulating satellite measurement data. It was developed with a focus on handling the requirements of repeat-track altimetry missions such as Topex and Jason. It was, however, designed to work with a wide variety of satellite measurement data [e.g., Gravity Recovery And Climate Experiment -- GRACE). The software consists of several command-line tools for importing, retrieving, and analyzing satellite measurement data.

deVarvalho, Robert↗

Theoretical and experimental power from large horizontal-axis wind turbines

A method for calculating the output power from large horizontal-axis wind turbines is presented. Modifications to the airfoil characteristics and the momentum portion of classical blade element-momentum theory are given that improve correlation with measured data. Improvement is particularly evident at low tip-speed ratios where aerodynamic stall can occur as the blade experiences high angles of attack. Output power calculated using the modified theory is compared with measured data for several large wind turbines. These wind turbines range in size from the DOE/NASA 100 kW Mod-0 (38 m rotor diameter) to the 2000 kW Mod-1 (61 m rotor diameter). The calculated results are in good agreement with measured data from these machines.

Viterna, L. A.↗

Validation Data for Benchmarking Wire Arc Additive Manufacturing Process Simulations

Residual stresses cause geometric distortion and affect mechanical performance of additively manufactured structures, yet they are notoriously difficult to assess and predict. Distortion (warpage) can drive parts outside dimensional tolerance limits, leading to part rejection or rework. For parts that meet tolerance, locked-in residual stress fields can affect structural integrity during operation, particularly subcritical cracking by fatigue, creep, or corrosion. This work develops benchmark data for a common additive manufacturing process (Wire Arc Additive Manufacturing) that can be applied for calibration and validation of physical process models that predict residual stress fields. The work includes design of two different samples of differing geometry, detailed manufacturing records for a set of physical samples, and an extensive set of residual stress measurement data developed using two diverse techniques (the contour method and neutron diffraction). An initial application of the work is also reported, where a modeling challenge was issued to secure residual stress model predictions from two independent laboratories that were blind to residual stress measurement data. These initial blind residual stress predictions show significant discrepancies relative to the measurement data, illustrating the potential value of the underlying validation data. An open repository for this work, including the sample designs, manufacturing process records, and the residual stress data, is also provided for future application in non-blind validation efforts.

36 MATERIALS SCIENCE↗

Self-potential tomography preconditioned by particle swarm optimization—Self-potential monitoring and streamflow data acquired March 26–September 14, 2023 at East Fork Poplar Creek near Oak Ridge Tennessee

This data release contains self-potential (SP) monitoring data measured on the flood plain of East Fork Poplar Creek (East Fork) in Oak Ridge, Tennessee and streamflow data measured at streamgage EFK5.4 about 310 meters upstream from the SP monitoring site. Additionally, forward and inverse numerical modeling scripts used to model the electrical-potential field on the East Fork flood plain are provided. SP monitoring data included in this data release were measured at 39 different data-collection points on the east flood plain; 30 points were spaced 3-m apart along an 87-m profile parallel to the edge of the streambank, and 9 points were spaced 5-m apart along a 40-m profile approximately perpendicular to the streambank. The two profiles of SP data-collection points intersected at the approximate midpoint of the profile parallel to the streambank. Transient voltages were measured at each data-collection point every 60 seconds between 16:13 Eastern Standard Time (EST) on March 26, 2023, and 11:41 EST on September 14, 2023. Streamflow data included in this data release overlap the time-period of self-potential monitoring and were measured every 900 seconds between 16:23 on March 26, 2023, and 23:53 on September 14, 2023.

54 ENVIRONMENTAL SCIENCES↗

Numerical analysis of particle dispersion and deposition in coal combustion using large-eddy simulation

High-fidelity modeling provides a useful approach to investigate the particle dispersion and deposition mechanism in pulverized coal combustion. To be able to analyze these detailed mechanisms, this work couples detailed multiphysics models for poly-dispersed turbulent, particle-laden flow, particle and gas phase reaction chemistry, convective, conductive and radiative heat transfer, ash formation and deposition with a Large-Eddy Simulation (LES) approach to numerically simulate coal combustion in a downfired self-sustained oxy-fuel combustor (OFC). It is necessary to explicitly capture all but the highest frequency dynamics of the turbulence and its coupling with each of the other physical phenomena using LES. Effects of subgrid-scale unresolved turbulence on the particle motions are also analyzed by a novel Stokes number analysis. Due to the inherent relation ship between coal combustion and ash deposition, this study integrates the improved ash deposition model into the numerical simulation. Overall simulation results are compared with experimentally measured data from the OFC. The simulation and measured data for the averaged gas temperature and deposition rates agree with 5% and 28%. This study shows that high-fidelity LES coupled with other detailed multiphysics models running on a exascale computing facility can provide a good representation of complex coal combustion and deposition in a laboratory-scale furnace.

multiphysics model↗

MPACT Verification and Validation Manual (rev 1)

The MPACT code provides the capability to calculate the steady-state and transient reactor core neutron distribution for operating nuclear power plant (PWR) conditions across multiple fuel cycles. As required in the CASL SQA plan, it is the responsibility of UM and ORNL as joint owners of MPACT to ensure that verification and validation activities are performed and documented in a V&V manual with supporting publications and CASL technical reports which can be distributed for reference and distribution within VERA. This document provides the first revision of the MPACT verification and validation (V&V) manual and describes the current state of MPACT V&V and updates the framework for future MPACT V&V activities. During FY16, MPACT V&V activities in the areas of code verification have continued to mature and work has progressed on code error evaluation using the Method of Manufactured Solutions (MMS). Several specific tasks have also been completed to improve MPACT code verification to include tasks to improve the unit and regression test coverage. A joint UM/ORNL task was completed to develop standardize coding standards and workflow for the continued collaborative development of MPACT. During the past year, MPACT validation work has continued in both the areas of measured data from critical experiments as well as measured data from operating nuclear power plants. Preliminary work was also performed in FY16 on the use of post-irradiation examinations for evaluation and validation of the isotopic depletion capability in MPACT. Based on the results of V&V efforts this past year, the confidence level has increased in the ability of MPACT to model an operational Pressurized Water Reactor. Areas were identified which require increased emphasis during FY17 to include updating all the V&V problems with the new 51-group library, the completion of cycle 2 of the BEAVRS benchmark, initial validation for BWR applications, the addition of Uncertainty Quantification results into the benchmark results, and the completion of specific validation tasks for the CASL Challenge problems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement and Controls Data Acquisition System

Measurement and Controls Data Acquisition System (MCDAS) is an application program that integrates the functions of two stand-alone programs: one for acquisition of data, the other for controls. MCDAS facilitates and improves testing of complex engineering systems by helping to perform calibration and setup of test systems and acquisition, dissemination, and processing of data. Features of MCDAS include an intuitive, user-friendly graphical user interface, a capability for acquiring data at rates greater than previously possible, cooperation between the data-acquisition software subsystem and alarm-checking and analytical components of the control software subsystem, and a capability for dissemination of data through fiber optics and virtual and wide-area networks, including networks that contain hand-held display units. The integration of the data acquisition and control software offers a safety advantage by making alarm information available to the control software in a more timely manner. By enabling the use of hand-held devices, MCDAS reduces the time spent by technicians asking for screen updates to determine effects of setup actions. Previously recorded data can be processed without interruption to current acquisition of data. Analysts can continue to view test parameters while test-data files are being generated.

Hall, Rick↗

A New Safeguards Technique for Spent Fuel Verification in Dry Storage by Using He-4 Detectors - 18262

It is demanded to find key issues and critical paths for verifying and monitoring a spent nuclear fuel cask or storage with a purpose of non-proliferation of nuclear weapon. However, unfortunately there are no reliable methods to verify the containment in a spent nuclear fuel cask or storage. Therefore, research and development (R and D) has been continuously required to develop new and alternative technologies for searching and verifying undeclared nuclear materials, activities, and facilities. Therefore, the present authors have developed a new safeguards technique of passively scanning a spent fuel cask or storage using pressurized He-4 scintillation neutron detectors. A new approach is to quickly verify content in a spent nuclear fuel cask or presence of all special nuclear materials in unknown packages by comparing experimental and computational results. For that, the present authors have developed a new algorithm and user-interface coupled ORIGEN-ARP and MCNP codes, and the prototype safeguards apparatus employing the array of He-4 fast neutron detectors has been designed, built, and tested. The feasibility test of this new apparatus has been performed with Cf-252 neutron sources and the laboratory scale model cask, minimized by a factor of ten compared to the actual dimension of a KN-21 cask. This technique has several advantages over current methods based on neutron and gamma detection; (1) incident neutron energy information is preserved, (2) disturbance of gamma-ray is excellently rejected (discriminated), and (3) much higher neutron counts and operational cost and space-effectiveness are expected since no moderator is required for fast neutrons. The final goal of this study will (1) conduct a prototype instrument and employ it to monitor a nuclear spent fuel cask or storage at a commercial nuclear power reactor facilities, (2) use spectral-specific measurement data to show proof of concept for measurable data successfully converted to quantifiable signatures, such as diversion/removal of fuel, and maintenance of fuel and cask integrity of fuel, and (3) develop a cask imaging capability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wind estimation using air data probe measurements to evaluate meteorological measurements made during Space Shuttle entries

Deterministic and weighted least squares methods for obtaining estimates of the horizontal winds encountered during the Shuttle entry phase are described. The estimates are based on in situ Air Data System (ADS) measurements of angle-of-attack, side-slip angle and true airspeed, in conjunction with inertial trajectory parameters obtained from the post flight trajectory reconstruction. Accuracies in the wind estimates obtained from each method are assessed using both theoretical arguments and flight results. Comparisons of derived winds with meteorological measurements taken during the first three Shuttle entries have demonstrated: (1) the usefulness of the wind estimators for evaluating meteorological measurements below 50 kft, and (2) the potential for adequate wind determinations in the absence of independent wind measurements. Comparisons of STS-3 flight-derived L/D versus predicted values from the LaRC aerodynamic data base are presented from 50 kft to touchdown. These results exemplify the importance of such determinations to enhance the ongoing Shuttle aerodynamic and aerothermodynamic research.

Kelly, G. M.↗

Stochastic Modeling and Power Control of Time-Varying Wireless Communication Networks

Wireless networks are characterized by nodes mobility, which makes the propagation environment time-varying and subject to fading. As a consequence, the statistical characteristics of the received signal vary continuously, giving rise to a Doppler power spectral density (DPSD) that varies from one observation instant to the next. This paper is concerned with dynamical modeling of time-varying wireless fading channels, their estimation and parameter identification, and optimal power control from received signal measurement data. The wireless channel is characterized using a stochastic state-space form and derived by approximating the time-varying DPSD of the channel. The expected maximization and Kalman filter are employed to recursively identify and estimate the channel parameters and states, respectively, from online received signal strength measured data. Moreover, we investigate a centralized optimal power control algorithm based on predictable strategies and employing the estimated channel parameters and states. The proposed models together with the estimation and power control algorithms are tested using experimental measurement data and the results are presented.

Doppler Power Spectral Density↗

Simulation and Modeling of Time-Resolved X-Ray Detector for the Saturn Accelerator

In this work, we present the technology-aided computer design (TCAD) device simulation and modeling of a silicon p-i-n diode for detecting time-dependent X-ray radiation. We show that the simulated forward and reverse breakdown current–voltage characteristics agree well with the measured data under nonradiation environment by only calibrating carrier lifetimes for the forward bias case and avalanche model critical fields for the reverse bias condition. Using the calibrated parameters and other nominal material properties, we simulated the radiation responses of the p-i-n diode and compared with experimental data when the diode was exposed to X-ray radiation at Sandia’s Saturn facility and the Idaho State University (ISU) TriMeV facility. For Saturn’s Gaussian dose-rate pulses, we show three findings from TCAD simulations. First, the simulated photocurrents are in excellent agreement with the measured data for two dose-rate pulses with peak values of 1.16×10 10 and 1.88×10 10 rad(Si)/s. Second, the simulation results of high dose-rate pulses predict increased delayed photocurrents with longer time tails in the diode electrical responses due to excess carrier generation. Third, simulated peak values of diode radiation responses versus peak dose rates at different bias conditions provide useful guidance to determine the dose-rate range that the p-i-n diode can reliably detect in experiment. For TriMeV’s non-Gaussian dose-rate pulse, our simulated diode response is in decent agreement with the measured data without further calibration. We also studied the effects of device geometry, recombination process, and dose-rate enhancement via TCAD simulations to understand the higher measured response in the time after the peak dose-rate radiation for the p-i-n diode exposed to TriMeV irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerance Decoupling: An Approach for Removing the Influence of the Test Stand from the Integrated Modal Test

The main objective for launch vehicle (LV) modal testing is to quantify the LV’s modal properties in the free-free state (post pad separation). However, given the size of most LV systems, free-free testing is a challenge and often not feasible. With this, a test stand, typically the launch pad itself, is introduced as the means of support. This shifts the challenge to developing robust numerical methods for removing the influence of the launch pad from the integrated system modal test. The Space Launch System (SLS) is no exception where the mobile launcher (ML) is used to support the vehicle for the integrated modal test (IMT). For the IMT, it is well understood from pre-test analysis with finite element models (FEMs) of the SLS and SLS coupled to ML that the ML has a significant influence on the SLS modal properties especially in the lower frequency range where the primary SLS bending modes exist. An accelerance decoupling (AD) method has been formulated for the purpose of “subtracting out” the influence of the ML from the IMT results. With AD, the SLS decoupled frequency response functions (FRFs) are directly extracted from the IMT FRFs. The subject approach is aimed to utilize measured data only and achieve a robust FRF decoupling scheme. AD is derived from a widely used coupling technique called “Receptance Coupling” (RC). The AD core equation reverses the RC process and utilizes a pair of auxiliary equations that enable the core equation to be resolved based on measured data only. In AD, the decoupled component FRFs are extracted from the coupled system FRFs with a transformation to remove the contribution of the “subtractive component”. This paper addresses the AD’s operational flexibility to resolve SLS free-free modal properties from coupled system measured data but also the possibility to include data from FEM if there is enough confidence in the FEM or if it is asserted that the effect to the final outcome is reasonable.

Accelerance decoupling↗

Accelerance Decoupling: An Approach for Removing the Influence of the Test Stand from the Integrated Modal Test

The main objective for launch vehicle (LV) modal testing is to quantify the LV’s modal properties in the free-free state (post pad separation). However, given the size of most LV systems, free-free testing is a challenge and often not feasible. With this, a test stand, typically the launch pad itself, is introduced as the means of support. This shifts the challenge to developing robust numerical methods for removing the influence of the launch pad from the integrated system modal test. The Space Launch System (SLS) is no exception where the mobile launcher (ML) is used to support the vehicle for the integrated modal test (IMT). For the IMT, it is well understood from pre-test analysis with finite element models (FEMs) of the SLS and SLS coupled to ML that the ML has a significant influence on the SLS modal properties especially in the lower frequency range where the primary SLS bending modes exist. An accelerance decoupling (AD) method has been formulated for the purpose of “subtracting out” the influence of the ML from the IMT results. With AD, the SLS decoupled frequency response functions (FRFs) are directly extracted from the IMT FRFs. The subject approach is aimed to utilize measured data only and achieve a robust FRF decoupling scheme. AD is derived from a widely used coupling technique called “Receptance Coupling” (RC). The AD core equation reverses the RC process and utilizes a pair of auxiliary equations that enable the core equation to be resolved based on measured data only. In AD, the decoupled component FRFs are extracted from the coupled system FRFs with a transformation to remove the contribution of the “subtractive component”. This paper addresses the AD’s operational flexibility to resolve SLS free-free modal properties from coupled system measured data but also the possibility to include data from FEM if there is enough confidence in the FEM or if it is asserted that the effect to the final outcome is reasonable.

Accelerance decoupling↗

Accelerance Decoupling: An Approach for Removing the Influence of the Test Stand from the Integrated Modal Test

The main objective for launch vehicle (LV) modal testing is to quantify the LV’s modal properties in the free-free state (post pad separation). However, given the size of most LV systems, free-free testing is a challenge and often not feasible. With this, a test stand, typically the launch pad itself, is introduced as the means of support. This shifts the challenge to developing robust numerical methods for removing the influence of the launch pad from the integrated system modal test. The Space Launch System (SLS) is no exception where the mobile launcher (ML) is used to support the vehicle for the integrated modal test (IMT). For the IMT, it is well understood from pre-test analysis with finite element models (FEMs) of the SLS and SLS coupled to ML that the ML has a significant influence on the SLS modal properties especially in the lower frequency range where the primary SLS bending modes exist. An accelerance decoupling (AD) method has been formulated for the purpose of “subtracting out” the influence of the ML from the IMT results. With AD, the SLS decoupled frequency response functions (FRFs) are directly extracted from the IMT FRFs. The subject approach is aimed to utilize measured data only and achieve a robust FRF decoupling scheme. AD is derived from a widely used coupling technique called “Receptance Coupling” (RC). The AD core equation reverses the RC process and utilizes a pair of auxiliary equations that enable the core equation to be resolved based on measured data only. In AD, the decoupled component FRFs are extracted from the coupled system FRFs with a transformation to remove the contribution of the “subtractive component”. This paper addresses the AD’s operational flexibility to resolve SLS free-free modal properties from coupled system measured data but also the possibility to include data from FEM if there is enough confidence in the FEM or if it is asserted that the effect to the final outcome is reasonable.

Accelerance decoupling↗

Validation of Spent Fuel Dose Rate Calculations Using NDA Measurement Campaign Data

The predicted radiation gamma dose rate is a key parameter to determine if a spent nuclear fuel assembly is self-protected from misuse as well as an indicator for worker/inspector safety. Recent studies showed that using state-of-the-art techniques for dose rate calculations, including the one adopted for this study, the numerical calculations of the gamma dose rates are three times lower than those from the most commonly-cited reference values for spent LWR fuel used by domestic and international agencies. With only a few publically available experimental data points worldwide for this type of benchmark study, the gamma flux measurements from the Spent Fuel Non Destructive Assay (NDA) measurement campaign can be used to help validate the physics approach used in calculating gamma dose rates. Specifically, this data would validate the gamma flux calculation from spent fuel, which is a key component of these multi-physics techniques for dose rate assessments; dose rate measurements were not part of the NDA campaign. These data are primarily the passive gamma measurements of the spent nuclear fuel assemblies from the Swedish Nuclear Fuel and Waste Management Company (SKB).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Algorithm for Removing Trends from Power-System Oscillation Data

When analyzing the electromechanical dynamic properties of power-system field-measurement data using signal processing techniques, it is often useful to identify and remove the slow trends within the data. This paper proposes an iterative non-linear trend identification algorithm. The proposed method adapts the upper and lower envelope idea proposed by empirical mode decomposition (EMD) method to identify the trend. The comparison with conventional trend identification methods are made with simulation data. Also, the proposed algorithm is ap-plied to a field measurement data set to evaluate its performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring a Black Body Source as an Absolute Radiometric Calibration Standard and Comparison with a NIST Traced Lamp Standard

Radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is required for the scientific research and application objectives pursued with the spectroscopic measurements. Specifically calibration is required for: inter-comparison of AVIRIS data measured at different locations and at different times; analysis of AVIRIS data with data measured by other instruments; and analysis of AVIRIS data in conjunction with computer models. The primary effect of radiometric calibration is conversion of AVIRIS instrument response values (digitized numbers, or DN) to units of absolute radiance. For example, a figure shows the instrument response spectrum measured by AVIRIS over a portion of Rogers Dry Lake, California, and another figure shows the same spectrum calibrated to radiance. Only the calibrated spectrum may be quantitatively analyzed for science research and application objectives. Since the initial development of the AVIRIS instrument-radiometric calibration has been based upon a 1000-W irradiance lamp with a calibration traced to the National Institute of Standards and Technology (NIST). There are several advantages to this irradiance-lamp calibration approach. First, the considerable effort of NIST backs up the calibration. Second, by changing the distance to the lamp, the output can closely span the radiance levels measured by AVIRIS. Third, this type of standard is widely used. Fourth, these calibrated lamps are comparatively inexpensive. Conversely, there are several disadvantages to this approach as well. First, the lamp is not a primary standard. Second, the lamp output characteristics may change in an unknown manner through time. Third, it is difficult to assess, constrain, or improve the calibration uncertainty delivered with the lamp. In an attempt to explore the effect and potentially address some of these disadvantages a set of analyses and measurements comparing an irradiance lamp with a black-body source have been completed. This research is ongoing, and the current set of measurements, analyses, and results are presented in this paper.

Green, Robert O.↗

Analysis of the pool critical assembly pressure vessel benchmark using pentran

The internationally circulated Pool Critical Assembly (PCA) Pressure Vessel Benchmark was analyzed using the PENTRAN Parallel Sn code system for the geometry, material, and source specifications as described in the PCA Benchmark documentation. This research focused on utilizing the BUGLE-96 cross section library and accompanying reaction rates, while examining both adaptive differencing on a coarse mesh basis as well as Directional Theta Weighted Sn differencing in order to compare the calculated PENTRAN results to measured data. The results show good comparison with the measured data as well as to the calculated results provided from TORT for the BUGLE-96 cross sections and reaction rates, which suggests PENTRAN is a viable and reliable code system for calculation of light water reactor neutron shielding and dosimetry calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗