Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Advanced Graphite Creep Uncertainty Analysis

Radiation damage estimation is an important component of the post irradiation analysis of the Advanced Graphite Creep (AGC) experiment. It depends primarily on the fast fluence, which is determined using well established methods of spectral adjustment. These are based on best estimates from models such as Monte Carlo N-Particle (MCNP), input cross-sections, and measured activities from flux wires in the experiment. Each of these parameters can propagate uncertainties which will affect the uncertainty in the calculated dose levels for AGC, or any experiment irradiated within a reactor. While the methods of propagating uncertainty are well-established, the final uncertainty estimates they provide are only as good as the estimates of uncertainty in the inputs on which they are based. The purpose of this work is to outline some deficiencies in the ways these input uncertainties are presently estimated, and to outline a methodology by which they can be improved. The fast fluence and radiation damage received by graphite specimens irradiated in the Advanced Graphite Creep (AGC) experiments is presently estimated using spectral adjustment methods that are based on both flux wire activity measurements, and MCNP model predictions. This work describes an ongoing effort to quantify and propagate uncertainties in inputs to the spectral adjustment process, and thereby quantify the resultant error in radiation damage (dpa) estimates. The effort is multi-faceted, and we consider the impacts of both the set of flux wires selected, and the counting process. An expanded set of flux wires is identified that provides a more comprehensive data set on the fast spectrum. To address the counting process itself, a series of round-robin measurements in several reactor metrology laboratories across the Department of Energy (DOE) complex and nuclear industry are being undertaken to refine the American Society for Testing and Materials (ASTM) standards for flux wire measurements. To address the contribution of uncertainty in the MCNP model predictions, an uncertainty quantification (UQ) tool has been developed that statistically samples the model input parameters, runs a series of cases, and assimilates the results to provide an overall uncertainty. The impact of the MCNP UQ tool results is demonstrated by re-analyzing previous AGC flux wire and irradiation data. While the expanded flux wire set obviously cannot be added to these experiments retroactively, plans for future graphite irradiations are outlined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Carbonyl Emissions from Gasoline and Diesel Motor Vehicles

Carbonyls from gasoline powered light-duty vehicles (LDVs) and heavy-duty diesel powered vehicles (HDDVs) operated on chassis dynamometers were measured using an annular denuder-quartz filter-polyurethane foam sampler with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine derivatization and chromatography-mass spectrometry analyses. Two internal standards were utilized based on carbonyl recovery, 4-fluorobenzaldehyde for<C8 carbonyls and 6-fluoro-4-chromanone for>_C8 compounds. Gas- and particle-phase emissions for 39 aliphatic and 20 aromatic carbonyls ranged from 0.1 ? 2000 ?g/L fuel for LDVs and 1.8 - 27000 mu g/L fuel for HDDVs. Gas-phase species accounted for 81-95percent of the total carbonyls from LDVs and 86-88percent from HDDVs. Particulate carbonyls emitted from a HDDV under realistic driving conditions were similar to concentrations measured in a diesel particulate matter (PM) standard reference material. Carbonyls accounted for 19percent of particulate organic carbon (POC) emissions from low-emission LDVs and 37percent of POC emissions from three-way catalyst equipped LDVs. This identifies carbonyls as one of the largest classes of compounds in LDV PM emissions. The carbonyl fraction of HDDV POC was lower, 3.3-3.9percent depending upon operational conditions. Partitioning analysis indicates the carbonyls had not achieved equilibrium between the gas- and particle-phase under the dilution factors of 126-584 used in the current study.

54 ENVIRONMENTAL SCIENCES↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physics-based model of irradiation creep for ferritic materials under fusion energy operation conditions

Irradiation creep is known to be an important process for structural materials in nuclear environments, potentially leading to creep failure at temperatures where thermal creep is generally negligible. While there is a great deal of data for irradiation creep in steels and zirconium alloys in light water reactor conditions, much less is known for first wall materials under fusion energy conditions. Lacking suitable fusion neutron sources for detailed experimentation, modeling, and simulation can help bridge the dose-rate and spectral-effects gap and produce quantifiable expectations for creep deformation of first wall materials under standard fusion conditions. In this paper, we develop a comprehensive model for irradiation creep created from merging a crystal plasticity representation of the dislocation microstructure and a defect evolution simulator that accounts for the entire cluster dimensionality space. Both approaches are linked by way of a climb velocity that captures dislocation-biased defect absorption and a dislocation strengthening term that reflects the accumulation of defect clusters in the system. Here, we carry out our study in Fe under first wall fusion reactor conditions, characterized by a fusion neutron spectrum with average recoil energies of 20 keV and a damage dose rate of ≈3×10 –7 dpa/s at temperatures between 300 and 800 K.

36 MATERIALS SCIENCE↗

Measuring Compositions in Organic Depth Profiling: Results from a VAMAS Interlaboratory Study

We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study on the measurement of composition in organic depth profiling. Layered samples with known binary compositions of Irganox 1010 and either Irganox 1098 or Fmoc-pentafluoro-L-phenylalanine in each layer were manufactured in a single batch and distributed to more than 20 participating laboratories. The samples were analyzed using argon cluster ion sputtering and either X-ray Photoelectron Spectroscopy (XPS) or Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) to generate depth profiles. Participants were asked to estimate the volume fractions in two of the layers and were provided with the compositions of all other layers. Participants using XPS provided volume fractions within 0.03 of the nominal values. Participants using ToF-SIMS either made no attempt, or used various methods that gave results ranging in error from 0.02 to over 0.10 in volume fraction, the latter representing a 50% relative error for a nominal volume fraction of 0.2. Error was predominantly caused by inadequacy in the ability to compensate for primary ion intensity variations and the matrix effect in SIMS. Matrix effects in these materials appear to be more pronounced as the number of atoms in both the primary analytical ion and the secondary ion increase. Using the participants’ data we show that organic SIMS matrix effects can be measured and are remarkably consistent between instruments. We provide recommendations for identifying and compensating for matrix effects. Finally we demonstrate, using a simple normalization method, that virtually all ToF-SIMS participants could have obtained estimates of volume fraction that were at least as accurate and consistent as XPS.

Environmental Molecular Sciences Laboratory↗

Beam Characterization at the Neutron Radiography Facility

The quality of a neutron imaging beam directly impacts the quality of radiographic images produced using that beam. Fully characterizing a neutron beam, including determination of the beam’s effective length-to-diameter ratio, neutron flux profile, energy spectrum, image quality, and beam divergence, is vital for producing quality radiographic images. This project characterized the east neutron imaging beamline at the Idaho National Laboratory Neutron Radiography Reactor (NRAD). The experiments which measured the beam’s effective length-to-diameter ratio and image quality are based on American Society for Testing and Materials (ASTM) standards. An analysis of the image produced by a calibrated phantom measured the beam divergence. The energy spectrum measurements consist of a series of foil irradiations using a selection of activation foils, compared to the results produced by a Monte Carlo n-Particle (MCNP) model of the beamline. Improvement of the existing NRAD MCNP beamline model includes validation of the model’s energy spectrum and the development of enhanced image simulation methods. The image simulation methods predict the radiographic image of an object based on the foil reaction rate data obtained by placing a model of the object in front of the image plane in an MCNP beamline model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Physical mechanisms of megahertz vibrations and nonlinear detection in ultrasonic force and related microscopies

Use of high frequency (HF) vibrations at MHz frequencies in Atomic Force Microscopy (AFM) advanced nanoscale property mapping to video rates, allowed use of cantilever dynamics for mapping nanomechanical properties of stiff materials, sensing μs time scale phenomena in nanostructures, and enabled detection of subsurface features with nanoscale resolution. All of these methods critically depend on the generally poor characterized HF behaviour of AFM cantilevers in contact with a studied sample, spatial and frequency response of piezotransducers, and transfer of ultrasonic vibrations between the probe and a specimen. Focusing particularly on Ultrasonic Force Microscopy (UFM), this work is also applicable to waveguide UFM, heterodyne force microscopy, and near-field holographic microscopy, all methods that exploit nonlinear tip-surface force interactions at high frequencies. Leveraging automated multidimensional measurements, spectroscopic UFM (sUFM) is introduced to investigate a range of common experimental parameters, including piezotransducer excitation frequency, probed position, ultrasonic amplitude, cantilever geometry, spring constant, and normal force. Consistent with studies of influence of each of these factors, the data-rich sUFM signatures allow efficient optimization of ultrasonic-AFM based measurements, leading to best practices recommendations of using longer cantilevers with lower fundamental resonance, while at the same time increasing the central frequency of HF piezo-actuators, and only comparing results within areas on the order of few μm{sup 2} unless calibrated directly or compared with in-the-imaged area standards. Diverse materials such as Si, Cr, and photoresist are specifically investigated. This work thereby provides essential insight into the reliable use of MHz vibrations with AFM and provides direct evidence substantiating phenomena such as sensitivity to adhesion, diminished friction for certain ultrasonic conditions, and the particular benefit of UFM and related methods for nanoscale mapping of stiff materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The effect of ultrafast laser wavelength on ablation properties and implications on sample introduction in inductively coupled plasma mass spectrometry

We investigated the role of femtosecond (fs) laser wavelength on laser ablation (LA) and its relation to laser generated aerosol counts and particle distribution, inductively coupled plasma-mass spectrometry (ICP-MS) signal intensity, detection limits, and elemental fractionation. Four different NIST standard reference materials (610, 613, 615, and 616) were ablated using 400 nm and 800 nm fs laser pulses to study the effect of wavelength on laser ablation rate, accuracy, precision, and fractionation. Our results show that the detection limits are lower for 400 nm laser excitation than 800 nm laser excitation at lower laser energies but approximately equal at higher energies. Ablation threshold was also found to be lower for 400 nm than 800 nm laser excitation. Particle size distributions are very similar for 400 nm and 800 nm wavelengths; however, they differ significantly in counts at similar laser fluence levels. This study concludes that 400 nm LA is more beneficial for sample introduction in ICP-MS, particularly when lower laser energies are to be used for ablation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The COBRA experiment – Status and prospects on the search of neutrinoless double beta-decay

The Cadmium-Zinc-Telluride 0-ν Double Beta Research Apparatus (COBRA) [1] is a next-generation experiment searching for the existence of neutrinoless double beta-decay (0νββ-decay). The observation of 0νββ-decay would be an unambiguous sign for physics beyond the Standard Model such as lepton number violating processes and would prove the Majorana character of neutrinos. Furthermore, the study of 0νββ-decay could probe the absolute neutrino mass and allows for the identification of the neutrino mass hierarchy realized in nature assuming light Majorana neutrino exchange. Currently a demonstrator setup at the underground facility LNGS (Italy) built of 4×4×4 coplanar grid (CPG) detectors collects high quality low background physics data with FADC pulse shape sampling. The detectors are made of natural abundant CdZnTe (CZT), which is a commercially available room temperature semiconductor. It contains several double beta isotopes, the most promising of which is {sup 116}Cd with a Q-value of 2813.5 keV – which is well above the highest naturally occurring prominent γ-lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spontaneous breaking of rotational symmetry in copper oxide superconductors

The origin of high-temperature superconductivity in copper oxides and the nature of the ‘normal’ state above the critical temperature are widely debated. In underdoped copper oxides, this normal state hosts a pseudogap and other anomalous features; and in the overdoped materials, the standard Bardeen–Cooper–Schrieffer description fails, challenging the idea that the normal state is a simple Fermi liquid. To investigate these questions, we have studied the behaviour of single-crystal La 2–x Sr x CuO 4 films through which an electrical current is being passed. Here we report that a spontaneous voltage develops across the sample, transverse (orthogonal) to the electrical current. The dependence of this voltage on probe current, temperature, in-plane device orientation and doping shows that this behaviour is intrinsic, substantial, robust and present over a broad range of temperature and doping. If the current direction is rotated in-plane by an angle $\phi$, the transverse voltage oscillates as sin(2$\phi$), breaking the four-fold rotational symmetry of the crystal. The amplitude of the oscillations is strongly peaked near the critical temperature for superconductivity and decreases with increasing doping. We find that these phenomena are manifestations of unexpected in-plane anisotropy in the electronic transport. The films are very thin and epitaxially constrained to be tetragonal (that is, with four-fold symmetry), so one expects a constant resistivity and zero transverse voltage, for every $\phi$. The origin of this anisotropy is purely electronic—the so-called electronic nematicity. Unusually, the nematic director is not aligned with the crystal axes, unless a substantial orthorhombic distortion is imposed. The fact that this anisotropy occurs in a material that exhibits high-temperature superconductivity may not be a coincidence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Drying of Spent Nuclear Fuel: Considerations and Examples

A recently revised American Society for Testing and Materials consensus standard guide for drying of spent nuclear fuel (SNF) provides considerations and guidance for preparing SNF for its safe storage in a sealed dry storage system. The standard discusses (1) needs for drying, (2) techniques to dry, and (3) demonstration of adequate dryness. No specific approach is prescribed since the effective techniques and needs for drying depend on the specifics of the fuel and dry storage system. Here, this paper discusses these topics using examples for both Zr-alloy-clad commercial SNF and for aluminum-alloy-clad research reactor SNF. Residual water can include free water (liquid and/or vapor), physisorbed water bound to internal surfaces, and chemisorbed water incorporated into surface films, such as (oxy)hydroxides. The potential impacts of these residual waters are corrosion/oxidation, radiolytic breakdown into gaseous and/or reactive species, and canister pressurization. For commercial SNF, inadvertent free water, even up to large amounts (e.g., 10+ mol), is not predicted to cause adverse corrosion degradation, except possible fuel oxidation for breached SNF. For aluminum-clad SNF, the production of radiolytic hydrogen with contribution from the chemisorbed water in its hydrated oxides is a primary consideration. For both SNF systems, canister pressurization is predicted to be well within the canister design, and flammability would not pose a safety concern using an oxygen limit of 5 vol % criterion. (Flammability control can be achieved by limiting either hydrogen or oxygen, and an oxygen limit is expected to be easier to meet in the presence of radiolytic H 2 generation.) The two primary technologies for SNF drying, vacuum drying and forced-gas dehydration, are described herein, and drying tests and campaigns using these methods are cited. Dryness criteria and the methods used to detect and measure residual (free) water are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accurate and Sensitive Analytical Strategy for the Determination of Antimony: Hydrogen Assisted T-Shaped Slotted Quartz Tube-Atom Trap-Flame Atomic Absorption Spectrometry

Antimony is known to have some adverse health effects on human health. Flame atomic absorption spectrometry (FAAS) is a widely used instrumental for the determination of antimony and other metals. However, it lacks the sensitivity to determine these metals at trace levels. This study was aimed at overcoming this setback by using hydrogen assisted T-shaped slotted quartz tube technique to preconcentrate and determine antimony by FAAS. All the system parameters were optimized to enhance the detection power of the system. Under the optimum experimental conditions, the limits of detection and quantification were found to be 0.75 and 2.49 µg L{sup −1}, respectively with R{sup 2} value of 0.9999. Accuracy of the developed method was validated by experimental results agreeing to the certified value of a standard reference material. Recovery studies were also carried out to determine the method’s applicability to tap and mineral water samples, and the results obtained were appreciable.

54 ENVIRONMENTAL SCIENCES↗

Isotopic Analysis of Uranium in NIST SRM Glass by Femtosecond Laser Ablation

We employed femtosecond Laser Ablation Multicollector Inductively Coupled Mass Spectrometry for the 11 determination of uranium isotope ratios in a series of standard reference material glasses (NIST 610, 612, 614, and 12 616). This uranium concentration in this series of SRM glasses is a combination of isotopically natural uranium in 13 the materials used to make the glass matrix and isotopically depleted uranium added to increase the uranium 14 elemental concentration across the series. Results for NIST 610 are in excellent agreement with literature values. 15 However, other than atom percent 235U, little information is available for the remaining glasses. We present atom 16 percent and isotope ratios for 234U, 235U, 236U, and 238U for all four glasses. Our results show deviations from the 17 certificate values for the atom percent 235U, indicating the need for further examination of the uranium isotopes in 18 NIST 610-616. Our results are fully consistent with a two isotopic component mixing between the depleted 19 uranium spike and natural uranium in the bulk glass.

Duffin, Andrew M.↗

Computational Removal of Undesired Mass Spectral Features Possessing Repeat Units via a Kendrick Mass Filter

Polymers are a common component of chemical background which complicates data analysis and can impair interpretation. Undesired chemical background cannot always be addressed via pre-analytical methods, chromatography, or existing data processing methods. The Kendrick mass filter (KMF) is presented for the computational removal of undesired signals present in MS{sup 1} spectra. The KMF is analogous to mass defect filtering but utilizes homology information via Kendrick mass scaling in combination with chromatographic retention time and the number of observed signals. The KMF is intended to assist in situations in which current data processing methods to remove background, e.g., blank subtraction, are either not possible or effective. The major parameters affecting KMF were investigated using PEG 400 and NIST standard reference material 1950 (metabolites in human plasma). Further exploration of the KMF performance was tested using an extract of a swab known to contain polymers. An illustrative real-world example of skin analysis with polymeric signal is discussed. The KMF is also able to provide a high-level view of the compositionality of data regarding the presence of signals with repeat units and indicate the presence of different polymers. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ethanolysis of camelina oil under supercritical condition with hexane as a co-solvent

Non-catalytic transesterification of camelina sativa oil under supercritical ethanol (SCE) conditions with hexane as a co-solvent was investigated to study the fatty acid ethyl ester (FAEE) yields. This process enables simultaneous transesterification of triglycerides and ethyl esterification of fatty acids in a shorter reaction of time and may reduce the energy consumption due to simplified separation and purification steps. It was found that the co-solvent plays a vital role in reducing the severity of critical operational parameters and maximizes the biodiesel yield. The important variables affecting the ethyl ester yield during the transesterification reaction are the molar ratio of alcohol/oil, reaction time, reaction temperature and co-solvent to oil ratio. Camelina biodiesel samples were analyzed using FT-IR, GC-MS and hermogravimetric analysis (TGA) methods. The fuel properties of camelina biodiesel produced were compared with those of the regular diesel and found to be conforming to the American Society for Testing and Materials (ASTMs) standards.

09 BIOMASS FUELS↗

Ultra-Low Level Plutonium Isotopes in the NIST SRM 4355A (Peruvian Soil-1)

For more than 20 years, countries and their agencies which monitor discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil reference material. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial pathway to man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from this SRM. The former must assess their laboratory contamination and measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclides that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels of the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development, and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. SRM 4355A will provide the mass spectrometric community with the quality control and testing material needed for higher sensitivity methods development, and legal defensibility.

Inn, Kenneth G↗

Anisotropic thermal diffusivity and conductivity in SiC/SiC tubes studied by infrared imaging and X-ray computed tomography

Traditional flash diffusivity evaluation of thermal diffusivity/conductivity of composite tubes require machining of specimens. For a thin-wall tube, this method can only be used to obtain through-thickness transport property. A novel method to evaluate anisotropic thermal diffusivity in a composite tube has been developed. Braided SiC/SiC composite tubes were subjected to a xenon flash heating pulse. A high-speed, high-sensitivity infrared camera was used to measure surface temperature changes as a function of time and nondestructively detect subsurface defects/damages, such as macroscopic pores. Standard reference material (Pyroceram 9606) and curved SiC/SiC composite tube specimens were used to validate thermal diffusivity obtained from infrared imaging. Unlike the traditional method, there is no need prepare special specimens, and thermal diffusivity values in three orientations are obtained after a single flash. A finite element analysis model based on x-ray computed tomography scans was developed to simulate the heat transfer. In conclusion, this technique is significant in assessing thermal conductivity and inspecting the health of ceramic tubes during and after service.

36 MATERIALS SCIENCE↗