Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Wind profile perturbation analysis for STS

Two case studies of the relationship between STS ascent structural loads and wind profile characteristics are described. In the first case study, a wind profile with relatively weak winds is used to demonstrate the importance of launch vehicle velocity relative to the air and its effect on loads. In the second study, a pair of wind profiles is used to show how the determination of load exceedances is strongly influenced by the wind load persistence allowances for the baseline and two day-of-launch (DOL) steering commands called I-LOADs. Characteristics of the wind profiles and associated trajectory variable and wind-sensitive load indicators are examined. Energy spectra of in-plane and out-of-plane wind component and a load indicator are presented. An analysis of load indicator sensitivity to wind perturbation energy in the 1600-6400 m wavelength band for baseline and DOL I-LOAD is described.

Adelfang, S. I.↗

High-resolution hourly surrogate modeling framework for physics-based large-scale building stock modeling

Surrogate modeling can play a key role in reducing high computational burdens for large-scale physics-based modeling and uncertainty quantification. With the rapid development of large-scale building stock energy modeling, surrogate modeling has also begun to be widely applied in this field; however, most existing surrogate models lack hourly time resolution for regional-scale modeling, which is essential for understanding building demand profiles and grid impacts. Further, there is generally a lack of necessary data and feature engineering frameworks specific to building modeling for efficiently managing large datasets and complex computations. Furthermore, this paper proposes a modeling framework for large-scale (city-/region-scale), high-resolution, high-fidelity surrogate building stock energy models. Our developed framework consists of six modules: (1) building stock energy modeling (ComStock TM and ResStock TM ), (2) data engineering for large simulation data, (3) high performance computing workflow, (4) feature engineering, (5) machine learning model development, and (6) model performance evaluation. Two case studies apply the developed framework in both residential and commercial building stock analysis to demonstrate its computational efficiency and surrogate modeling accuracies. Results show that surrogate models, when efficiently trained using the HPC workflow module, reach a high level of modeling accuracy for two case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of electric vehicle charging on the power demand of retail buildings

As electric vehicle penetration increases, charging is expected to have a significant impact on the grid. Electric vehicle charging stations will greatly affect a building site's power demand, especially with the onset of fast charging with power levels as high as 350 kW per charger. Here, we assess how electric vehicle charging stations would impact a retail big box grocery store, exploring numerous station sizes, charging power levels, and utilization factors in various climate zones and seasons. We measure the effect of charging by assessing changes in monthly peak power demand, electricity usage, and annual electricity bill, computed using three distinct rate structures. We find that an electric vehicle station has the potential to dwarf a big box building's power demand if behind the same meter, increasing monthly peak power demand at the site by over 250%. Cold-climate areas paired with rate structures incorporating high demand charges are most susceptible for significant changes to the annual electricity bill, with increases as high as 88%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interplay between liver and blood stages of Plasmodium infection dictates malaria severity via γδ T cells and IL-17-promoted stress erythropoiesis

Plasmodium replicates within the liver prior to reaching the bloodstream and infecting red blood cells. Because clinical manifestations of malaria only arise during the blood stage of infection, a perception exists that liver infection does not impact disease pathology. By developing a murine model where the liver and blood stages of infection are uncoupled, we showed that the integration of signals from both stages dictated mortality outcomes. This dichotomy relied on liver stage-dependent activation of Vγ4 + γδ T cells. Subsequent blood stage parasite loads dictated their cytokine profiles, where low parasite loads preferentially expanded IL-17-producing γδ T cells. IL-17 drove extra-medullary erythropoiesis and concomitant reticulocytosis, which protected mice from lethal experimental cerebral malaria (ECM). Adoptive transfer of erythroid precursors could rescue mice from ECM. Modeling of γδ T cell dynamics suggests that this protective mechanism may be key for the establishment of naturally acquired malaria immunity among frequently exposed individuals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A hybrid surrogate modeling framework for the Digital Twin of a Fluoride-salt-cooled High-temperature Reactor (FHR)

While nuclear energy is a non-greenhouse-gas emitting energy source, expensive operational costs due to the high-level of safety requirements decreases their competitiveness in the sustainable energy market. Advanced reactor concepts paired with Digital Twins aim to increase the commercialization gains of nuclear energy by reducing operational costs, increasing reactor reliability and enhancing power generation. To support Digital Twin tasks such as real-time autonomous control, proactive maintenance monitoring or optimizing power demand operations, a fast and accurate virtual representation of the Nuclear Power Plant (NPP) is required. The computational cost of high-fidelity, physics-based models are unsuitable for real-time analysis or scalability. Here, in this work, a hybrid surrogate modeling framework is developed fora Fluoride-salt-cooled High-temperature Reactor (FHR) that leverages physics-inspired models for key reactor components and uses data-driven methods for rapid system state space prediction. The Xenon reactivity feedback model is integrated to inform the surrogate model about the reactor core and the homologous pump theory model is the basis for representing pump degradation. Using a detailed, two dimensional thermal hydraulics model to generate data on the FHR, we train a network of Vectorized Autoregressive Moving-Average with eXogenous input (VARMAX) models to predict the remaining state values. The result is a surrogate model that provides a detailed reactor state representation of 41 system states and a pump degradation analysis. The framework is applied to Load Follows profiles, yielding high accuracy and a speedup that is more than 4000x faster compared to the higher- fidelity thermal hydraulics model, enabling real-time operational intelligence and applications in long horizon predictions. While the surrogate model framework is demonstrated for the particular case of FHR, the hybrid physical/data-driven modeling approach including the network of surrogates and the underlying modularity has the potential to be applied to other physical asset systems.

Digital Twins↗

Electrifying education: Exploring the electrification potential of U.S. School bus fleets

We analyze the operations of 270 diesel school buses across the United States to assess their electrification potential and evaluate the impact of various charging strategies on electricity demand. We find that school buses typically follow a two-route schedule on weekdays, featuring extended dwell times between morning and evening trips. Weekday trip distances average 25 miles, while weekend trips average 42 miles. Charging simulations indicate over 90% of the U.S. school bus fleet could be electrified using current technologies (300-mile range at 1.21 kWh/mile with 19.2-kW depot charging) without modifying existing operating patterns. Depot charging is a key enabler of school bus electrification, however, the strategic placement of charging stations at other locations (e.g., schools) can further increase electrification potential. Additionally, we find electric school bus charging to be highly flexible, with charge management capable of reducing peak charging loads at depots by up to 77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fluid temperature predictions of geothermal borefields using load estimations via state observers

Fluid temperature predictions of geothermal borefields usually involves temporal superposition of its characteristic g-function, using load aggregation schemes to reduce computational times. Assuming that the ground has linear properties, it can be modeled as a linear state space system where the states are the aggregated loads. However, the application and accuracy of these models is compromised when the borefield is already operating and its load history is not registered or there are gaps in the data. This paper assesses the performance of state observers to estimate the borefield load history and obtain accurate fluid predictions. Results show that both Time-Varying Kalman Filter (TVKF) and Moving Horizon Estimator (MHE) provide predictions with average and maximum errors below 0.1 $^\circ C$ and 1 $^\circ C$ respectively. MHE outperforms TVKF in terms of n-step ahead output predictions and load history profile at the expenses of about 5 times more computational time.

Figueroa, Iago C.↗

Improving the Accuracy of Clustering Electric Utility Net Load Data using Dynamic Time Warping

Identifying patterns in electric utility net load data in a time-series format is very useful in preparing the operation for next day. Machine learning algorithms have been used in other domains and those concepts are applied in this paper on real-world net load measurement data. Clustering is the practice of grouping data with similar characteristics as determined by the distance measure. The K-means clustering algorithm is utilized here with actual electric utility data. The paper uses the standard distance measure, Euclidean distance (ED), and compares its performance against the dynamic time warping (DTW) measure. An actual case study with real data is presented, and DTW distance measure-based method observed to result better accuracy compared to the ED based method for substation net load measurements predominantly with residential customers.

clustering↗

Underlying Data for the EVI-RoadTrip Web Tool

The dataset contains simulation-based charging infrastructure outputs that are visualized on the EVI-RoadTrip webtool. The outputs are aggregated to lower spatial resolution (e.g., state-level, corridor-level).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Dataset of EV Charging Stations With Estimates of Load and Vehicle Throughput

Current data from the AFDC provide locations and many details about EV charging stations, but not estimates of their peak loads or the number of vehicles they can accommodate. This dataset will augment the AFDC charging station locations with estimates of transmission load and vehicle throughput based on engineering specifications of the chargers, charging patterns based on vehicle types, battery capacities, and user behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Charger Requirements for GSE at Each Airport

This dataset contains the required number of chargers for GSE at each airport under six charging scenarios: (1) charging when the battery state of charge is insufficient for the next service using 40-kW chargers (S1); (2) charging when the battery state of charge is insufficient for the next service using 20-kW chargers (S2); (3) charging starts immediately after each GSE completes a service task using 40-kW chargers (S3); (4) charging starts immediately after each GSE completes a service task using 20-kW chargers (S4); (5) charging during off-peak hours using 40-kW chargers (S5); and (6) charging during off-peak hours using 20-kW chargers (S6).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast Charging Infrastructure for Electrifying Road Trips to and from National Parks in the Western United States

National parks in the Western United States draw over 80 million visitors every year, and most visitors rely on personal cars for their road trips (or long-distance travels). Travel to national parks represents distinct travel demand, as they are typically located in remote areas necessitating long-distance trips. This study investigates the quantity and locations of on-route fast charging infrastructure needed by 2030 to enable seamless travel to/from national parks using electric vehicles in seven target states in the region, employing unprecedented high-resolution spatial and temporal analysis. We find that the required number of fast charging ports for on-route charging infrastructure ranges from 1,200 to 22,000, depending on different assumptions of key input parameters - vehicle electrification rate, charging behavior, average gap between charging stations, port utilization rate, and towing trailers. Our analysis also indicates that electrical load for on-route fast charging infrastructure would peak in the afternoon, in the range of 70-400 MW, varying with the key input parameters. This study illustrates how different input parameters result in different degrees of impact on various aspects of charging infrastructure. We also examine the characteristics of projected charging infrastructure in terms of land use type, relationship with traffic volume, size of stations, and other variables.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Savings Shapes: Measure Documentation: Add Exhaust Air Heat/Energy Recovery

This documentation focuses on a single end-use savings shape measure—Add Exhaust Air Heat/Energy Recovery. This measure adds exhaust air energy recovery or heat recovery to existing air handling units (AHU) with outdoor air. Systems that already have energy/heat recovery are not modified. Furthermore, food service building types are also not modified by this measure due to the added complication of integrating cooking hood exhaust that could cause heat exchanger fouling from kitchen exhaust. In total, this measure is applicable airloops serving ~70% of the floor area in ComStock. In practice, energy/heat recovery systems are retrofitted to existing air delivery systems either as separate systems that provide outdoor air to the AHUs or are directly integrated to an AHU; the modeling approach used in this study is agnostic of the energy recovery type and simply accounts recovery effectiveness, added static pressure, and other controls which are described further in this document. Energy recovery with sensible and latent exchange gets added in humid climate zones, while heat recovery with sensible-only exchange gets added in drier climate zones. Energy recovery is modeled as a fixed membrane plate counterflow heat exchanger, while heat recovery is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and electric resistance preheat coil for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Demand Control Ventilation

This documentation focuses on a single end-use savings shape measure - Demand Control Ventilation (DCV). DCV can save energy by reducing the rate at which outdoor air (OA) is delivered during periods of less-than-design occupancy. This measure will enable DCV for air loops using applicable HVAC system types (all except dedicated outdoor air systems [DOAS], packaged systems, or that have an energy recovery ventilator [ERV]) and serving applicable space types (all except kitchens, dining areas, patient spaces, mechanical rooms, stairwells and corridors, or high exhaust space types) using model occupancy schedules to control the DCV. The measure is applicable to 72.7% of the stock floor area. As office buildings outside of California in ComStock are modeled using a single, whole-building space type, DCV is not applied to these building types. The DCV measure demonstrates 2.6% total site energy savings (119 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗