Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Depot-Based Vehicle Data for National Analysis of Medium- and Heavy-Duty Electric Vehicle Charging

Medium- and heavy-duty vehicles (MHDVs) are a major source of greenhouse gases and local criteria air pollutants. Electrifying MHDVs may reduce these harmful emissions, which disproportionately impact disadvantaged communities. Due to their relatively high per-vehicle energy needs, consistent fleet operations, and frequent colocation of multiple vehicles at depots, MHDVs may have more spatially and temporally concentrated charging demands than light-duty passenger electric vehicles. That charging concentration means their electrification may require careful advance planning and coordination to manage potential impacts to the electrical grid via charge management or infrastructure upgrades. However, MHDV duty cycles and parking schedules are highly variable across vocations of operation, and there is a shortage of nationally representative, vocationally diverse public data describing typical MHDV operations. This report summarizes the methodology - designed with national representativeness in mind - used to create a new set of data describing typical daily driving distances, dwell durations, and normalized electric vehicle depot charging load curves for MHDVs. The dataset reflects the subset of MHDV operating patterns that may originate from a consistent depot each day and rely on the same depot for charging. In addition to trucks with depot-centric vocational patterns, the data describes operations of transit buses and school buses, each with a depot-centric focus. The dataset is available to the public and suitable for national analysis. It can inform research, infrastructure planning, and policymaking regarding the electrification of MHDVs.

33 ADVANCED PROPULSION SYSTEMS↗

Machine Learning-Based Identification of the Interface Regions for Coupling Local and Nonlocal Models

Local-nonlocal coupling approaches provide a means to combine the computational efficiency of local models and the accuracy of nonlocal models. However, the coupling process can be challenging, requiring expertise to identify the interface between local and nonlocal regions. Here, this study introduces a machine learning-based approach to automatically detect the regions in which the local and nonlocal models should be used. The method uses loading functions evaluated at grid points to decide the model selection at those points. Training of the networks is based on datasets provided by classes of loading functions for which reference coupling configurations are computed using accurate coupled solutions, where accuracy is measured in terms of the relative error between the solution to the coupling approach and the solution to the nonlocal model. We study two approaches that vary in data structure. The first, the full-domain input data approach, uses the entire load vector and outputs a complete label vector, performing a global classification. The second, a window-based approach, processes loads into windows and addresses the problem as a node-wise classification where each window's central point is classified individually. The classification problems are solved via deep learning algorithms based on convolutional neural networks. The performance of these approaches is studied on one-dimensional numerical examples using F1-scores and accuracy metrics. Notably, the windowing approach achieves an accuracy of 0.96 and an F1-score of 0.97, highlighting its potential to automate coupling processes effectively and enhance computational efficiency in material science applications.

97 MATHEMATICS AND COMPUTING↗

OpenSAMPL: An Open Source Library for Timing and Synchronization Measurements and Analytics

Today's power grid operators are implementing timing and synchronization solutions that provide resilience to Global Navigation Satellite System (GNSS) vulnerabilities. These vendor-specific solutions often come with additional software applications that are designed to monitor that vendor's synchronization performance data. However, resilient timing architectures often resulting in multi-vendor solutions, including approaches that blend terrestrial clocks with space-based subscription services. In such an environment, collecting, analyzing, and visualizing data from a variety of sources within a single platform was heretofore not possible. To address this need, the US Department of Energy's Center for Alternative Synchronization and Timing (CAST) developed OpenSAMPL, the Open Synchronized Analytics and Monitoring Platform, an open-source Python framework for processing, loading, and observing clock measurement data from distributed devices. OpenSAMPL enables the ingestion of diverse clock-probe sources into a scalable time-series database and applies robust analytics. OpenSAMPL currently supports two vendor data pipelines, and will be extended to more in the near future, enabling seamless monitoring of a variety of timing and synchronization devices in a common environment.

Grant, Josh [ORNL] (ORCID:0000000163475060)↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Hanford Low-Activity Waste Glass Property Data Development: Phase 5 and Phase 6

This report summarizes the data collected on two test matrices of low-activity waste (LAW) glass compositions intended to expand the composition-property database: Low-Activity Waste (LAW) Phase 5: Expansion of LAW Glass Composition Boundaries and LAW Phase 6: High PCT and VHT Response Glass Matrix. Both matrix glass compositions were statistically designed to expand the LAW glass composition region. The analyses performed on these glasses include chemical composition (for target compositional verification), density, viscosity, electrical conductivity, crystal fraction, container centerline cooling with crystal identification, the product consistency test (PCT) response, the vapor hydration test (VHT) response, and sulfur solubility. Because of the slightly different scope of the two matrices, not all methods were applied to both matrices. Specifically, the following measurements were taken only on the LAW Phase 5: Expansion of LAW Glass Composition Boundaries glasses: crystal fraction as a function of temperature, density (ρ), viscosity (η), and electrical conductivity (EC, e). Combined, these data contribute a significant amount, 51 glasses, to the database for high LAW loaded enhanced waste glasses. Most of these data are focused near the boundaries of acceptable PCT and VHT responses, where prediction uncertainties are most impactful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experiments and modelling of adhesive failure initiation of an epoxy underfill: a study of electronic packaging survivability

Epoxy underfills can be implemented in electronic packaging to enhance solder joint reliability of surface mounted components. However, it is important for an engineer to have a failure criterion that can be used for failure predictions and redesign of electronic assemblies. For this study, data from epoxy bond failure in mock electronic part assemblies were correlated to finite element analyses to predict adhesive failure initiation. Experiments were performed to determine failure loads for various loading locations and nonlinear viscoelastic analyses were performed for the same loading locations to determine a maximum principal strain failure parameter. Predictions showed that a maximum principal strain failure parameter defined from one test could be used as an indicator of adhesive failure of an epoxy bond undergoing other modes of loading. Failure initiation predictions matched experimental data using a maximum principal strain failure parameter for an epoxy bond undergoing mixed modes of loading for both unfilled and alumina oxide filled 828DEA epoxy. Such experimental setup is deemed appropriate for future epoxy testing.

42 ENGINEERING↗

ESnet/JLab FPGA Accelerated Transport

To increase the science rate for high data rates/volumes, Thomas Jefferson National Accelerator Facility (JLab) has partnered with Energy Sciences Network (ESnet) to define an edge to data center traffic shaping / steering transport capability featuring data event aware network shaping and forwarding. The keystone of this ESnet+JLab FPGA Accelerated Transport (EJFAT) is the joint development of an AI/ML directed dynamic compute work Load Balancer (LB) of UDP streamed data. The LB is a suite consisting of a Field Programmable Gate Array (FPGA) executing the dynamically configurable, low fixed latency LB data plane featuring real-time packet redirection and high throughput, and a control plane running on the FPGA host computer that monitors network and compute farm telemetry in order to make dynamic AI/ML guided decisions for destination compute host redirection/load balancing and destination resource provisioning. The LB provides for three-tier horizontal scaling across LB suites, core compute hosts, and CPUs within a host. The LB effectively provides seamless integration of edge/core computing to support direct experimental data processing for immediate use by JLab science programs and others such as the EIC as well as data centers of the future requiring high throughput and low latency for both hot and cooled data for both running experiment data acquisition systems and data center use cases.

97 MATHEMATICS AND COMPUTING↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calibrating Synchronous-Generator-Interfaced DG Models in Microgrids Using Multiple Event Data

Microgrids, consisting of distributed generators (DGs), loads, and energy storage systems, play an important role in future smart grids. In order to evaluate how microgrids operate and their dynamic response, it is necessary to develop accurate dynamic models of DGs in microgrids. This paper proposes a systematic method to calibrate synchronous-generator-interfaced DG models. Challenges associated with model validation in microgrids are analyzed. Underlying parameters are categorized into two groups, i.e., the steady-state parameters and time constants, which are estimated in two successive stages using multiple event data. This methodology ensures that the validated model with the estimated parameters are applicable for all events. A modified unscented Kalman filter (UKF) is proposed to deal with the cases in which measurement of power angle is unavailable. The effectiveness of the proposed method is validated using field test data of a 2.6 MVA diesel generator in a real microgrid.

Wang, Zhiwen↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

A Transformational Natural Gas Fueled Dynamic SOFC for Data Center in-Rack Power (Final Technical Report)

Data centers consume 250TWh or 1% of global electricity use in 2019. This electricity demand is expected to grow exponentially in the future. The current data center power supply relies on electric grids with diesel engines and batteries as backup; the latter is critically important because a sudden loss of power could erase crucial data, causing catastrophic economic loss. However, such a double protection architecture is costly, inefficient and polluting. In search for better in-rack power system, fuel-cell based generators have recently emerged as a promising alternative to diesel engines and batteries because of its potential to be more cost-effective, more efficient and less polluting. Among many types of fuel cells, solid oxide fuel cells stand out to be a front runner because of their ability to directly operate on natural gas that has an existing infrastructure. However, there are several critical challenges facing SOFC generators to meet the rigorous power requirements of data centers: high cost, poor reliability and more importantly, slow response to the datacenters’ dynamic load change. The unexpected overload conditions in data centers can cause fuel starvation; the latter can initiate microcracks in the anode structure, thus jeopardizing the lifetime of the SOFC generator. The current efforts to increase transient power capabilities of traditional SOFCs and therefore protect SOFC stacks from internal damage during transient loading, rely primarily upon mathematical algorithms. One of the challenges to these control methodologies is the physical limitations of the fuel delivery system such as slow response of mass flow controllers to fast power demand.

30 DIRECT ENERGY CONVERSION↗

A Framework for Streamlining Large Load Interconnection: An Assessment of Current Practices and Emerging Strategies for Fair and Efficient Load Interconnection Processes

This report focuses on current perceptions, challenges, and processes related to interconnection of LELs to the grid; while these loads include several types of entities, the primary focus of this work is on data centers, the largest current driver of this growth. It begins by summarizing relevant context related to load growth in the United States, including key stakeholder perceptions as data center deployment drive historic load growth nationwide. It then reviews the current landscape of large load interconnection processes and challenges and then proposes a framework of potential strategies intended to support a more consistent, streamlined, and fair approach to load interconnection. This framework is adapted from solutions proposed or adopted to address similar challenges faced in generator interconnection queues as well as notable reforms currently being proposed or enacted for large loads that could be more widely adopted.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anthropogenic effects on flood hazards in a hyper-arid watershed: The 2015 Atacama floods

An unprecedented precipitation event in the hyper-arid Atacama Desert of Northern Chile occurred in March 2015. Geomorphic alterations to the river channel and the coastal zone, coupled with the exceptional magnitude of the rainfall, caused catastrophic damage and loss of life. On the coast of the El Salado watershed, legacy mine tailings infilled the watershed-ocean connection, while the river channel was altered both by tailings and urbanization. The consequences of this event resulted from the coupling of anthropogenic geomorphic changes with an unusual climate event. Lack of field data, complex geomorphology and sediment loads influenced by human activity make analysing floods in these regions especially challenging. The objective of this work is to improve our understanding of the factors that control flood hazards by using numerical simulations to reconstruct the 2015 flood in El Salado. We carry out unsteady two-dimensional simulations fully coupled with the sediment concentration to identify the influence of tailing deposits, considering high-resolution data of the pre- and post-2015 flood topography. In conclusion, the results highlight the importance of specific event-based studies, using models that can help designing better strategies for climate change adaptation and risk mitigation, while providing information for risk reduction and channel restoration.

54 ENVIRONMENTAL SCIENCES↗

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE↗

Demographic Information Incorporated Household Energy Consumption Analysis

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

Demographic Information Incorporated Household Energy Consumption Analysis: Preprint

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

Demographic Information Incorporated Household Energy Consumption Analysis

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗