Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons

The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3% in the barrel and 2.8% in the endcaps. This leads to an estimated contribution to the constant term of (0.29$+0.05\atop{-0.04}$) % in the barrel and (0.54$+0.06\atop{-0.04}$)% in the endcaps. Lastly, the same data are used to measure the drift velocity of ionization electrons in liquid argon, which is found to be 4.61 ± 0.07 mm/μs at 88.5 K and 1 kV/mm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New read-out electronics for ICARUS-T600 liquid argon TPC. Description, simulation and tests of the new front-end and ADC system

Here, the ICARUS T600, a liquid argon time projection chamber (LAr-TPC) detector mainly devoted to neutrino physics, underwent a major overhauling at CERN in 2016-2017, which included also a new design of the read-out electronics, in view of its operation in Fermilab on the Short Baseline Neutrino (SBN) beam from 2019. The new more compact electronics showed capability of handling more efficiently the signals also in the intermediate Induction 2 wire plane with a significant increase of signal to noise (S/N), allowing for charge measurement also in this view. The new front-end and the analog to digital conversion (ADC) system are presented together with the results of the tests on 50 liters liquid argon TPC performed at CERN with cosmic rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermoelectric-enhanced, liquid-based cooling of a multi-component electronic system

Methods are provided for facilitating cooling of an electronic component. The methods include providing: a liquid-cooled structure, a thermal conduction path coupling the electronic component and the liquid-cooled structure, a coolant loop in fluid communication with a coolant-carrying channel of the liquid-cooled structure, and an outdoor-air-cooled heat exchange unit coupled to facilitate heat transfer from the liquid-cooled structure via, at least in part, the coolant loop. The thermoelectric array facilitates transfer of heat from the electronic component to the liquid-cooled structure, and the heat exchange unit cools coolant passing through the coolant loop by dissipating heat from the coolant to outdoor ambient air. In one implementation, temperature of coolant entering the liquid-cooled structure is greater than temperature of the outdoor ambient air to which heat is dissipated.

47 OTHER INSTRUMENTATION↗

Mechanisms Underlying Plastocyanin-Cytochrome f Electron Transfer Investigated via Site-Specific Linear and Two-dimensional Infrared Spectroscopy

The goal of this research is to further our understanding of biological electron transfer in photosynthesis through the development and application of new methods for studying proteins with high spatial and temporal detail. Biological electron transfer occurs between metal sites imbedded in proteins where the environment and its motions can be very different from those of normal bulk liquids. Moreover, electron transfer between two proteins typically involves short-lived binding interactions within a highly mobile complex. We have directed our studies at photosynthetic electron transfer proteins plastocyanin and cytochrome f. We have labeled two key ligands to the copper ion of plastocyanin with carbon deuterium probe vibrations that enable their selective analysis by infrared spectroscopy. This analysis has shown that association of plastocyanin with cytochrome f leads to large changes in the bonding between the copper ion and ligands. In addition, the probes have been used to assess the contribution of the protein scaffold of plastocyanin in dictating the copper coordination geometry. We also have made progress to extend our experiments from equilibrium to non-equilibrium studies. The studies help to illuminate how proteins are tuned to control biological electron transfer. A better understanding of electron transfer reactions in natural photosynthesis will bolster efforts to develop artificial systems for energy production.

59 BASIC BIOLOGICAL SCIENCES↗

Patterning a π-conjugated polyelectrolyte through sequential polymerization of a bifunctional ionic liquid monomer

An electronically conductive polyelectrolyte is prepared by the sequential polymerization of a bifunctional imidazolium-based ionic liquid (IL) monomer, composed of a thienyl and vinyl containing cation paired with a tetrafluoroborate anion. In the first step, potentiodynamic electropolymerization of the thienyl moiety forms a cationic polyalkylthiophene that is soluble in select organic solvents. Cyclic voltammetry (CV) was used to determine the polymer p-doping potential (0.31 V) and the bipolaronic state (1.49 V). The polymer exhibits electrochromism, converting from red in the neutral state (lambda(max) = 443 nm) to dark blue in the polaronic state (lambda(max) = 819 nm). The solution-processable polymer can be cast into a film, masked and patterned by UV-initiated free radical polymerization of the vinyl moiety. Small-angle X-ray scattering (SAXS) revealed that the insoluble crosslinked polyalkylthiophene-polyvinylimidazolium adopts a lamellar structure with a lattice spacing of 3.3 nm. Four-probe d.c. conductivity measurements determined the de-doped electrical conductivity was 1.0 x 10(-2) S/cm. The results underscore the importance of the anion in controlling the polymerization of IL monomers.

Ionic liquid↗

Method and apparatus for electrokinetic co-generation of hydrogen and electric power from liquid water microjets

A method and apparatus for producing both a gas and electrical power from a flowing liquid, the method comprising: a) providing a source liquid containing ions that when neutralized form a gas; b) providing a velocity to the source liquid relative to a solid material to form a charged liquid microjet, which subsequently breaks up into a droplet spay, the solid material forming a liquid-solid interface; and c) supplying electrons to the charged liquid by contacting a spray stream of the charged liquid with an electron source. In one embodiment, where the liquid is water, hydrogen gas is formed and a streaming current is generated. The apparatus comprises a source of pressurized liquid, a microjet nozzle, a conduit for delivering said liquid to said microjet nozzle, and a conductive metal target sufficiently spaced from said nozzle such that the jet stream produced by said microjet is discontinuous at said target. In one arrangement, with the metal nozzle and target electrically connected to ground, both hydrogen gas and a streaming current are generated at the target as it is impinged by the streaming, liquid spray microjet.

42 ENGINEERING↗

Resonant dissociative electron transfer of the presolvated electron to CCl{sub 4} in liquid: Direct observation and lifetime of the CCl{sub 4}*{sup -} transition state

We report a pump-probe femtosecond transient absorption spectroscopic study on the electron transfer reaction of CCl{sub 4} in liquid ethanol. By direct observations of the presolvated electron and of the reaction transition state CCl{sub 4}*{sup -}, this study provides direct evidence of the resonant dissociative electron transfer (RDET) of the presolvated electron to CCl{sub 4}. Moreover, the lifetime of CCl{sub 4}*{sup -} in ethanol is directly obtained from the decay kinetics and its measured value is found to be nearly identical to its gas-phase value. Hence, these results also imply that RDET can be an efficient process in an aqueous environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualizing Millisecond Atomic Dynamics of Nanocrystals in Liquid

Atomic structures of nanomaterials are inherently dynamic and continuously reshaped through interactions with chemical species and external stimuli. Such dynamics are further amplified as the size and dimensionality of nanomaterials decrease. Despite advances in analytical methods, it remains challenging to capture the structural dynamics of nanomaterials in reactive environments with both atomic spatial resolution and commensurate temporal resolution. Here, in this study, we directly visualize atomic-scale dynamics of gold (Au) nanocrystals in reactive liquid environments with millisecond-speed liquid-cell electron microscopy (EM) and deep-learning denoising. We uncover reversible fluctuations in the local crystallinity of Au nanocrystals dependent on the surrounding chemical environment. These transient fluctuations, driven by interactions at nanocrystal–liquid interfaces, critically influence the dissolution kinetics and grain boundary relaxation. By overcoming the spatiotemporal limitations in conventional liquid-cell EM, our findings provide insights into how transient nanoscale structures dictate the stability and reactivity of nanomaterials.

Kang, Sungsu [University of Chicago, IL (United St↗

Liquid Extraction Surface Analysis (LESA) Electron-Induced Dissociation and Collision-Induced Dissociation Mass Spectrometry of Small Molecule Drug Compounds

Here, we present liquid extraction surface analysis (LESA) coupled with electron-induced dissociation (EID) mass spectrometry in a Fourier-transform ion cyclotron resonance mass spectrometer for the analysis of small organic pharmaceutical compounds directly from dosed tissue. First, the direct infusion electrospray ionisation EID and collision-induced dissociation (CID) behaviour of erlotinib, moxifloxacin, clozapine and olanzapine standards were compared. EID mass spectra were also compared with experimental or reference electron impact ionisation mass spectra. The results show that (with the exception of erlotinib) EID and CID result in complementary fragment ions. Subsequently, we performed LESA EID MS/MS and LESA CID MS/MS on singly charged ions of moxifloxacin and erlotinib extracted from a thin tissue section of rat kidney from a cassette-dosed animal. Both techniques provided structural information, with the majority of peaks observed for the drug standards also observed for the tissue-extracted species. Overall, these results demonstrate the feasibility of LESA EID MS/MS of drug compounds from dosed tissue and extend the number of molecular structures for which EID behaviour has been determined. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search for the Migdal effect in liquid xenon with keV-level nuclear recoils

The Migdal effect predicts that a nuclear recoil interaction can be accompanied by atomic ionization, allowing many dark matter direct detection experiments to gain sensitivity to sub-GeV masses. We report the first direct search for the Migdal effect for M- and L-shell electrons in liquid xenon using nuclear recoils produced by tagged neutron scatters. Despite an observed background rate lower than that of expected signals in the region of interest, we do not observe a signal consistent with predictions. We discuss possible explanations, including inaccurate predictions for either the Migdal rate or the signal response in liquid xenon. We comment on the implications for direct dark matter searches and future Migdal characterization efforts. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long life electrodes for large-area x-ray generators

This invention is directed to rugged, reliable, and long-life electrodes for use in large-area, high-current-density electron gun and x-ray generators which are employed as contamination-free preionizers for high-energy pulsed gas lasers. The electron source at the cathode is a corona plasma formed at the interface between a conductor, or semiconductor, and a high-permittivity dielectric. Detailed descriptions are provided of a reliable cold plasma cathode, as well as an efficient liquid-cooled electron beam target (anode) and x-ray generator which concentrates the x-ray flux in the direction of an x-ray window.

Rothe, Dietmar E.↗

Importance of interlayer H bonding structure to the stability of layered minerals

Layered (oxy) hydroxide minerals often possess out-of-plane hydrogen atoms that form hydrogen bonding networks which stabilize the layered structure. However, less is known about how the ordering of these bonds affects the structural stability and solubility of these minerals. Here, we report a new strategy that uses the focused electron beam to probe the effect of differences in hydrogen bonding networks on mineral solubility. In this regard, the dissolution behavior of boehmite (γ-AlOOH) and gibbsite (γ-Al(OH)3) were compared and contrasted in real time via liquid cell electron microscopy. Under identical such conditions, 2D-nanosheets of boehmite (γ-AlOOH) exfoliated from the bulk and then rapidly dissolved, whereas gibbsite was stable. Further, substitution of only 1% Fe(III) for Al(III) in the structure of boehmite inhibited delamination and dissolution. Factors such as pH, radiolytic species, and knock on damage were systematically studied and eliminated as proximal causes for boehmite dissolution. Instead, the creation of electron/hole pairs was considered to be the mechanism that drove dissolution. The widely disparate behaviors of boehmite, gibbsite, and Fe-doped boehmite are discussed in the context of differences in the OH bond strengths, hydrogen bonding networks, and the presence or absence of electron/hole recombination centers.

58 GEOSCIENCES↗

Latest results from Double Chooz

Double Chooz is a short-baseline neutrino disappearance experiment. It detects ν̄{sub e }produced in the power plant of Chooz, France, where is located. The main goal of the experiment is the measurement of θ{sub 13} mixing angle and in 2011 for the first time the experiment observed an indication for a non zero value of such an oscillation parameter. The mixing angle was successively measured using only the far detector finding the best fit value of sin{sup 2}(2θ{sub 13}) = 0.090{sup +0.032}{sub −0.029} . The near detector is under construction and will start data taking by the middle of 2014 allowing the reduction of the systematic errors. In this paper I make a review of the Double Chooz experiment, focusing in particular on the latest results of the measurement of the mixing angle θ{sub 13} relying on the neutron absorption on Gadolinium. I also present results proving the capability of Double Chooz to identify the ortho-positronium. This has been done in an event-by-event basis for the first time in a large liquid scintillator experiments, and can be an additional handle for the electron/positron discrimination in future detectors based on such technology.

42 ENGINEERING↗

Using Density-Corrected DFT to Understand Density-Driven and Functional-Dependent Errors in Ab Initio Simulations of the Hydrated Electron

The hydrated electron, an excess electron in liquid water, plays a crucial role in a plethora of chemical processes, motivating extensive research efforts to characterize its structure, dynamics, and reactivity in solution. Recent theoretical approaches to understanding this intriguing object have involved ab initio simulations based on density functional theory (DFT). Although DFT allows for the study of hydrated electron reactivity and quantum mechanical behavior, it is well-known that anionic systems can suffer from significant density-driven errors (DDEs). Density-corrected DFT (DC-DFT) provides a framework to mitigate such errors; the method reduces DDEs by replacing the self-consistent (SC) density associated with a given density functional with the Hartree–Fock (HF) density. Since HF densities tend to be more localized than DFT SC densities, the DC-DFT scheme significantly improves errors in calculations where the SC density is spuriously delocalized. Here, we investigate how the use of density correction affects the calculated properties of the DFT-simulated (PBEh) hydrated electron, a particularly challenging diffuse anionic system to simulate. First, we analyze charge delocalization in a system consisting of a model octahedral hydrated electron water cluster (the so-called Kevan structure) along with a spatially separated sulfur atom. We show that the use of density correction indeed reduces DDEs in comparison to a standard DFT global hybrid functional. We then propagate molecular dynamics trajectories of the hydrated electron using DC-DFT, where we find that DC further localizes electron density in the cavity region, a signature of reduced charge delocalization. Unfortunately, the decreased radius of gyration of the spin density and corresponding tightening of the local solvation structure from density correction causes predicted observables to deviate further from experimental measurements than when density correction is not employed. Here, we argue that DC’s worse agreement with experiment results from the removal of a fortuitous cancellation of errors that is intrinsic to the PBEh functional. This indicates that the difficulties with DFT to simulate hydrated electrons are primarily due to the inherent approximations in DFT rather than to density-driven errors.

Density functional theory↗

Calibration and simulation of ionization signal and electronics noise in the ICARUS liquid argon time projection chamber

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedure removes non-uniformities in the ICARUS TPC response to charge in space and time. This work leverages the copious number of cosmic ray muons available to ICARUS at the surface. The ionization signal shape simulation applies a novel procedure that tunes the simulation to match what is measured in data. The end result of the equalization procedure and simulation tuning allows for a comparison of charge measurements in ICARUS between Monte Carlo simulation and data, showing good performance with minimal residual bias between the two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗