Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Feasibility and Utility of a Cryogenic Integrated RCS

Traditional in-space propulsion systems use storable propellants, such as MMH/NTO, for applications beyond Low Earth Orbit (LEO). Modern advancements in Cryogenic Fluid Management (CFM) technologies opens the door for use of more efficient cryogenic propellants, such as LOX/LCH4 or LOX/LH2, in these long-duration missions beyond LEO. As these Main Propulsion Systems (MPS) transition to cryogenic propellants, a cryogenic solution for Reaction Control Systems (RCS) becomes attractive for several reasons. A mixed-fluid vehicle solution with cryogenic (cool) MPS and storable (warm) RCS complicates thermal management. Additionally, a vehicle with common cryogenic propellant across the MPS and RCS could take advantage of shared hardware such as tanks, thermal management equipment, and pressurization system, reducing mass and development time. The fluid system design proposed in this presentation features shared hardware, leading to the designation of Cryogenic Integrated Reaction Control System (iRCS). The iRCS design stores cryogenic propellant in the low-pressure (10’s psia) MPS tanks, creates steady high-pressure (100’s psia) flow through an electric pump (e-pump), feeds pulse-firing RCS thrusters, and returns any excess flow to the tank through a pressure control device on a recirculation line. This iRCS design is inspired by the automotive fuel-rail, where similar elevated-pressure and pulse-firing requirements are levied. This design has several inherent advantages. Because this design is pump-fed rather than pressure-fed, heavy, high-pressure propellant storage is not required. The RCS propellant can therefore be stored by increasing MPS tank volume. Furthermore, by increasing the pressure of the circulated fluid through an e-pump, the propellant quality moves further into the sub-cooled regime. Sub-cooled liquid is desirable for accurate pressure and flow control at the thruster inlet. Lastly, the iRCS allows the distribution system hardware to maintain cryogenic temperatures by slowly recirculating liquid in a low-energy “Idle Mode”. Altogether, the iRCS concept enables a more efficient cryogenic vehicle design.

Integrated↗

Application of Analytical Hierarchy Process for Narrowing Down Nep Candidate Reactor Designs

Nuclear electric propulsion (NEP)-powered vehicles have been contemplated for human Mars missions. The nuclear power system contemplates using a high temperature light-weight nuclear reactor for the production of electrical power in the range of 2-5 MWe with a 3-10 year service life. A myriad of technology options exist for achieving these mission objectives. The analytic hierarchy process (AHP), a multi-attribute decision method, is being used to narrow down the candidate designs. The AHP is a structured decision process that fuses model-supplied quantitative data with subjective assessments to facilitate decisions that involve multiple competing criteria. Proven end-to-end nuclear design and systems analysis tools will be used to provide quantitative performance data such as end-to-end system reliability, system robustness to recover from off-normal conditions, system specific weight (α in kg/kWe), and the ability to meet the service life-time and power level requirements. Three high assay low enriched uranium (HALEU) reactor concepts, namely, gas-, heat pipe- and pumped liquid-cooled nuclear cores coupled to a He/Xe gas or supercritical CO2- Brayton power conversion system are being modeled using the AHP to understand the trade-offs associated with these design combinations. In addition to the reactor and power conversion options, there are a myriad of additional components and subsystems – e.g., radiators, heat exchangers, and recuperators – that also figure into the evaluation process. The choice of the right overall system is a multidimensional problem that has to include not only quantitative data, but also the so called “external factors”, examples of which include the component and subsystem Technology Readiness Levels (TRLs), the associated Advancement Degrees of Difficulty (AD2), the cost and schedule required to achieve a technical maturity consistent with mission infusion, alignment with the priorities of NASA’s Space Nuclear Propulsion program, and alignment with other ongoing government and commercial investments in micro reactors. Focused expert elicitations form the basis for qualitative data set. As a final step, decision-makers individually express their opinions regarding the relative importance of the criteria and preferences among the alternatives through pairwise comparisons. The paper will describe the AHP approach, progress to-date applying it to the NEP human Mars mission problem, and preliminary results. Use of AHP provides sufficient flexibility for incorporating industry input at different stages as the technologies evolve through additional research and development. It is expected that the decision process will be ongoing and expanded to examine additional options and technology choices, culminating in a defensible set of candidate reactor concepts that will form the basis for developing a multi-year NEP technology maturation strategy. .

Dasari V Rao↗

Development and Integration of a Thermal Management Simulation for a Quadrotor Parallel Hybrid Propulsion System

This paper details the development of a propulsion system simulation for a six-passenger parallel hybrid quadrotor and utilizes the Numerical Propulsion System Simulation (NPSS) along with the NPSS Power System Library as the development environment. This simulation integrates an engine power plant with an electrical generation and distribution system and includes the required thermal management system. The thermal management system is comprised of liquid cooling loops that reject the heat load through air to coolant heat exchangers and utilizes a map-based performance estimation method. This method is developed within NPSS and detailed in this paper. The full system model is designed to predict system weight, range, and performance through a proposed mission profile. Results of the paper show an all-engine system maintains the best range, while a mostly electric system that utilizes an engine as a backup or a conditional power contributor offers range benefit.

Vertical lift and take off vehicle↗

Development and Integration of a Thermal Management Simulation for a Quadrotor Parallel Hybrid Propulsion System

This paper details the development of a propulsion system simulation for a six-passenger parallel hybrid quadrotor and utilizes the Numerical Propulsion System Simulation (NPSS) along with the NPSS Power System Library as the development environment. This simulation integrates an engine power plant with an electrical generation and distribution system and includes the required thermal management system. The thermal management system is comprised of liquid cooling loops that reject the heat load through air to coolant heat exchangers and utilizes a map-based performance estimation method. This method is developed within NPSS and detailed in this paper. The full system model is designed to predict system weight, range, and performance through a proposed mission profile. Results of the paper show an all-engine system maintains the best range, while a mostly electric system that utilizes an engine as a backup or a conditional power contributor offers range benefit.

Vertical lift and take off vehicle↗

NASA Advanced Space Suit xEMU Development Report – Components

For the past several years, the Exploration Extra-Vehicular Mobility Unit (xEMU) team at NASA’s Johnson Space Center has focused on the development and detailed design of the xEMU to support missions to the International Space Station (ISS) and a moon landing in 2024. In that context, this paper examines the development and baseline detailed design of the xEMU helmet, extra-vehicular visor assembly (EVVA), hard upper torso (HUT), shoulders, liquid cooling and ventilation garment (LCVG), boots, waist brief hip (WBH), ancillary hardware, and environmental protection garment (EPG) . This paper will outline the challenging technical requirements, significant architectural trades, technical solutions required to overcome these challenges, and a current status of the detailed design. The preliminary results of Design Verification Testing (DVT) as it relates specifically to these components will also be provided, along with a forward strategy for final maturation into a flight-ready design.

Shane McFarland↗

Human Thermal Assessment of Traverse and Geology Task Iterations During Simulated Lunar Extravehicular Activity

Spacewalks or extravehicular activities (EVA) in microgravity are mentally and physically demanding. Current microgravity EVAs are predominantly focused on upper body tasks on engineered surfaces; however, the introduction of gravity means that crew members during future lunar EVAs will be required to perform tasks that generate full body workloads such as navigating natural lunar terrain while conducting geological sampling. To date, only 12 people have walked on the surface of the Moon resulting in limited knowledge of suited thermal regulation under lunar-relevant physical workloads. To address this gap, a study is underway to focus on spacesuit operations with simulated lunar EVA workloads. This study presents methodology for collecting standard thermal measures during suit testing. In this pilot study, two suited subjects underwent simulated lunar EVAs using the NASA Active Response Gravity Offload System (ARGOS) to simulate the effects of partial gravity. Each lunar EVA, lasting three to five hours, included various metabolically demanding EVA tasks. Subjects donned the NASA Mark III (MK III) space suit and were offloaded to 1/6th G (lunar gravity). A subset task circuit from one of these simulations replicated an EVA traverse to a lunar crater, taking a geological sample, and returning to base. The suited subject walked one 1500 m (0% grade) and three 500 m traverses at three different grades (10, 20, 30%). Between each traverse, subjects performed geology sampling tasks (0 and 10% grade). Thermal measurements included core and skin temperature, liquid cooling garment (LCG) inlet and outlet temperature, and spacesuit gas inlet and outlet temperature and humidity. Compared to baseline core temperature (S1 = 37.07±0.32 °C, S2 = 37.27±0.01 °C) and mean skin temperature (S1 = 32.38±0.34 °C, S2 = 33.62±0.03 °C), after a 1500 m traverse, each suited subject showed an increased core temperature (S1 = 37.23±0.12 °C, S2 = 37.41±0.11°C) and decreased mean skin temperature (S1 = 32.16±0.17 °C, S2 = 31.53±1.15 °C) at a delta LCG temperature (S1 = 1.86±0.24 °C, S2 = 2.20±0.76 °C) and delta suit humidity (S1 = 9.66±1.49 %, S2 = 11.50±1.58 %). Core temperature continued to increase from compounding traverse and geology tasks (S1 = 38.04±0.03 °C, S2 = 38.1±0.02 °C) accompanied by an increase in delta LCG temperature (S1 = 2.24±0.13 °C, S2 = 2.67±0.12 °C) and delta suit humidity (S1 = 28±2.42 %, S2 = 31±2.13 %). Conversely, as the circuit progressed, mean skin temperature continued to decrease due to sustained LCG heat rejection (S1 = 30.08±0.15 °C, S2 = 30.28±0.07 °C). During the simulated EVA circuit core temperature increased to elevated values and remained elevated as heat was retained while mean skin temperature decreased due to peripheral heat offloaded to the LCG. The thermal measures collected during this study provided critical heat loading dynamics during lunar EVA tasks. Including core and skin temperatures along with suited thermal measures provides a standard data collection scheme for human thermal metrics during EVA task management. Data collected in this configuration can be used to build future lunar EVA task circuits and human thermal predictions.

Bradley Hoffmann↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A pervious TCV version with a linear actuator and diverter valve has been tested extensively to attempt to control the flow accurately. The previous TCV diverter valve has a non-linear flow response relative to valve position and has struggled to accurately meet the setpoints desired for precision thermal control. While many diverter valve design variations have been attempted, previous designs have all had difficulty in meeting set points. Additionally, high precision machining is required for these diverter valves to create a metal-on-metal seal which has its own drawbacks and doesn’t always meet requirements for internal leakage. This metal compression seal also requires stalling the linear actuator to load the seal in compression or tension which has demonstrated valve sticking failures when stalled. The xEMU PLSS TCV implements a new approach and design for a TCV which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. A new geometric design modification to the ball outlet can create a set-able orifice like hole which is more predictable at controlling flow than using an annulus with the previous diverter valve. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

High Speed Data Investigation of an LOX/LNG Combustor Assisted by Non-linear Acoustic Simulations

During testing of a regenerative cooled liquid oxygen/liquid natural gas combustor large amplitude combustion instabilities were observed in half of the series conducted. These instabilities produced an unsteady pressure Root Mean Square (RMS) value greater than the chamber steady state pressure. Quick look investigations of the test data presented some standard indications of non-linear tangential instability such as a non-sinusoidal time series, and larger peaks than trough. Also observed in the data quick look were some atypical findings including a first harmonic amplitude larger than the fundamental, and numerous side bands on the fundamental and subsequent harmonics. A simplified model of the combustor was created using a commercially available finite element software. The first tangential acoustic mode was then simulated using a non-linear wave equation in conjunction with a time explicit discontinuous Gelarkin flow solver. Numerous simulations were evaluated providing valuable insight and reproducing the atypical findings in the data. Side bands were created through non-linear signal modulation like an AM radio. This happens due to the non-linear steepening and relaxing that occurs in large amplitude oscillations. The simulation was also able to reproduce a signal with a first harmonic amplitude larger than the fundamental. Investigating the pressure signal at multiple locations across the chamber head end revealed radial dependent frequency content. A literature review of the topic revealed corroboration of these effect in idealized geometries.

Combustion Stability↗

Updates and Correlation of EMU System-Level Model (SINDA EMU)

During United States Extravehicular Activity 80 (US EVA 80), water was observed in the helmet of an Extravehicular Mobility Unit (EMU) during cabin repressurization. One of the primary methods of determining the likely cause of this failure was through a comparison of EVA 80 to other historical EVAs using an analytical approach. The Systems Improved Numerical Differential Analysis EMU model (SINDA EMU) is a system-level model of the EMU that was used in this investigation. SINDA EMU was initially developed and correlated to test data in the 1980s. Since its conception, SINDA EMU has been continually adjusted based on new test data and changes to the EMU design. To support the water in the helmet investigation, SINDA EMU needed to be further updated and recorrelated to ensure accurate results. These changes included changing the primary carbon dioxide (CO2) removal technology, implementing logic to allow for re-evaporation of sweat runoff from the liquid cooling and ventilation garment (LCVG), and improving the transient modeling capabilities. To validate the implementation of these adjustments, SINDA EMU was correlated to test data from the 1990s and human-in-the-loop (HITL) testing from 2014. These updates and correlation efforts proved that SINDA EMU is an effective tool for investigating the EVA 80 water in the helmet failure event.

Noah Lial Andersen↗

High Speed Data Investigation of an LOX/LNG Combustor Assisted by Non-linear Acoustic Simulations

During testing of a regenerative cooled liquid oxygen/liquid natural gas combustor large amplitude combustion instabilities were observed in half of the series conducted. These instabilities produced an unsteady pressure Root Mean Square (RMS) value greater than the chamber steady state pressure. Quick look investigations of the test data presented some standard indications of non-linear tangential instability such as a non-sinusoidal time series, and larger peaks than trough. Also observed in the data quick look were some atypical findings including a first harmonic amplitude larger than the fundamental, and numerous side bands on the fundamental and subsequent harmonics. A simplified model of the combustor was created using a commercially available finite element software. The first tangential acoustic mode was then simulated using a non-linear wave equation in conjunction with a time explicit discontinuous Gelarkin flow solver. Numerous simulations were evaluated providing valuable insight and reproducing the atypical findings in the data. Side bands were created through non-linear signal modulation like an AM radio. This happens due to the non-linear steepening and relaxing that occurs in large amplitude oscillations. The simulation was also able to reproduce a signal with a first harmonic amplitude larger than the fundamental. Investigating the pressure signal at multiple locations across the chamber head end revealed radial dependent frequency content. A literature review of the topic revealed corroboration of these effect in idealized geometries.

Combustion Stability↗

Developing a Hybrid Spacesuit Simulator as a Research Tool for Assessing Extravehicular Activity Relevant Workload

Conducting human tests in a pressurized spacesuit is limited by availability, cost, and manpower; however, pressurized spacesuits are not always needed depending on the objectives of testing, including the development and testing of new informatics capabilities. The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA is developing a Hybrid Spacesuit Simulator (HS3) to support testing and characterization of human performance during analog planetary exploration extravehicular activities (EVAs). The goal of HS3 is to create a low-cost, modular, and unpressurized spacesuit simulator as a research tool that provides relevant physical and cognitive workload approximations with EVA-like immersion. HS3 consists of a soft outer suit, thermal control, gloves, boots, helmet, and integrated bioinformatics and communications. Baseline HS3 assessments were performed during 3-hour EVA simulations in two different subjects (DEMO1 and DEMO2) that included traverses at variable resistances and geological sampling activities. Liquid cooling garment (LCG) temperature, mean skin temperature, heart rate, motion capture, and metabolic rate were collected during each 3-hour simulated EVA. During DEMO1 and DEMO2, baseline metabolic rates at rest were 836 ± 327 BTU/hr and 869 ± 207 BTU/hr and increased to 2124 ± 548 BTU/hr and 2269 ± 559 BTU/hr, respectively, during 500m traverse. Average inlet LCG temperatures were 29.57 ± 6.62 °C and 25.63 ± 6.48 °C for DEMO1 and DEMO2 with increased outlet LCG temperatures of 33.53 ± 6.62 °C and 29.21 ± 4.79 °C, respectively. Overall, HS3 will enable future studies to characterize EVA tasks, human performance, and test future EVA capabilities in analog test environments without the need for pressurized suited environments.

Monica Hew↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Developing A Hybrid Spacesuit Simulator as A Research Tool for Assessing Extravehicular Activity Relevant Workload

Conducting human tests in a pressurized spacesuit is limited by availability, cost, and manpower; however, pressurized spacesuits are not always needed depending on the objectives of testing, including the development and testing of new informatics capabilities. The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA is developing a Hybrid Spacesuit Simulator (HS3) to support testing and characterization of human performance during analog planetary exploration extravehicular activities (EVAs). The goal of HS3 is to create a low-cost, modular, and unpressurized spacesuit simulator as a research tool that provides relevant physical and cognitive workload approximations with EVA-like immersion. HS3 consists of a soft outer suit, thermal control, gloves, boots, helmet, and integrated bioinformatics and communications. Baseline HS3 assessments were performed during 3-hour EVA simulations in two different subjects (DEMO1 and DEMO2) that included traverses at variable resistances and geological sampling activities. Liquid cooling garment (LCG) temperature, mean skin temperature, heart rate, motion capture, and metabolic rate were collected during each 3-hour simulated EVA. During DEMO1 and DEMO2, baseline metabolic rates at rest were 836 ± 327 BTU/hr and 869 ± 207 BTU/hr and increased to 2124 ± 548 BTU/hr and 2269 ± 559 BTU/hr, respectively, during 500m traverse. Average inlet LCG temperatures were 29.57 ± 6.62 °C and 25.63 ± 6.48 °C for DEMO1 and DEMO2 with increased outlet LCG temperatures of 33.53 ± 6.62 °C and 29.21 ± 4.79 °C, respectively. Overall, HS3 will enable future studies to characterize EVA tasks, human performance, and test future EVA capabilities in analog test environments without the need for pressurized suited environments.

Suit simulator↗

Core Body Temperature Predictions Using Metabolic Energy Expenditure and Heart Rate During Simulated Extravehicular Activity

Long duration spaceflight missions will require crew to become more autonomous in conducting extravehicular activities (EVA) without direct communication with Mission Control for biomedical support. To enable such autonomy, we are developing a Crew State and Risk Model (CSRM) as a collection of key physiology domains that drive EVA crew capabilities and workloads. One model component of CSRM is human thermal regulation. In this paper, customized development of a baseline model to predict core body temperature is presented using physiology inputs of heart rate and metabolic rate. The model development dataset included a baseline study where participants (n=6, equal male and female) performed a 5-hour EVA in a two-part session while wearing a hybrid space suit simulator (HS3). The first session included an end-to-end EVA traversing 1500 meters to a geology site and traversing back to a habitat conducting geology, payload relocation, and maintenance operations every 500 meters. The second session included standalone tasks of a 2000-meter traverse followed by geology tasks. Thermal measures of core body temperature, local skin temperature, liquid cooling garment temperature, heart rate, and metabolic rate were collected through the test duration. Multiple regression was used to build a linear equation to predict core body temperature from inputs of heart rate and metabolic rate. Heat storage was calculated via predicted core body temperature plus LCG and skin temperatures. The model was tested against a dataset from a pressurized suited test (n=6, equal male and female) in the NASA Active Response Gravity Offload System (ARGOS) conducting similar end-to-end EVA and standalone tasks. Predicted error of the model against the raw test cases was 0.2±0.15 °C. The baseline prediction of core body temperature using heart rates and metabolic rates allows for simple real-time tracking from data collected in-flight to monitor crew consumables and thermal flight limits during EVA.

Bradley Hoffmann↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the QUEEN V2 Test

A liquid-cooled electric ducted fan system was designed, built, and tested at the NASA Glenn Research Center. Main components of the system include a Commercial-Off- the-Shelf (COTS) fan and motor, and a custom-designed heat exchanger integrated into the fan duct. Fan speed, thrust, and cooling system thermal performance was measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V2.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for regional single-aisle aircraft. This test demonstrated the functionality of the QUEEN V2, quantified the thrust produced by the electrofan, and characterized the electrical and thermal performance of the system. Lessons learned will be used to guide development of future QUEEN prototypes.

Aerodynamics↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the QUEEN V2 Test

A liquid-cooled electric ducted fan system was designed, built, and tested at the NASA Glenn Research Center. Main components of the system include a Commercial-Off- the-Shelf (COTS) fan and motor, and a custom-designed heat exchanger integrated into the fan duct. Fan speed, thrust, and cooling system thermal performance was measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V2.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for regional single-aisle aircraft. This test demonstrated the functionality of the QUEEN V2, quantified the thrust produced by the electrofan, and characterized the electrical and thermal performance of the system. Lessons learned will be used to guide development of future QUEEN prototypes.

Aeronautics-General↗

Short xEMU Pressure Garment Thermal Vacuum Test Results

NASA performed a thermal-vacuum test of the Exploration Extravehicular Mobility Unit (xEMU) to demonstrate the performance of the government reference design in a relevant space-like environment. One of the spacesuit test articles was configurated as a Short-xEMU (SxEMU). This unmanned configuration provided an excellent test to evaluate the Exploration Portable Life Support System (xPLSS), however it posed some challenges with the Exploration Pressure Garment (xPGS) components involved due to the lack of a human wearing a Liquid Cooling and Ventilation Garment (LCVG), which significantly contributes to the thermal performance of the suit. This paper provides an overview of the pressure garment components that made up this portion of the test article, the test configuration, test results, and lessons learned from this very unique spacesuit test.

xemu↗