Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid argon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Wire-cell 3D pattern recognition techniques for neutrino event reconstruction in large LArTPCs: algorithm description and quantitative evaluation with MicroBooNE simulation

Wire-Cell is a 3D event reconstruction package for liquid argon time projection chambers. Through geometry, time, and drifted charge from multiple readout wire planes, 3D space points with associated charge are reconstructed prior to the pattern recognition stage. Pattern recognition techniques, including track trajectory and dQ/dx (ionization charge per unit length) fitting, 3D neutrino vertex fitting, track and shower separation, particle-level clustering, and particle identification are then applied on these 3D space points as well as the original 2D projection measurements. A deep neural network is developed to enhance the reconstruction of the neutrino interaction vertex. Compared to traditional algorithms, the deep neural network boosts the vertex efficiency by a relative 30% for charged-current ν e interactions. Therefore, this pattern recognition achieves 80–90% reconstruction efficiencies for primary leptons, after a 65.8% (72.9%) vertex efficiency for charged-current ν e (ν μ ) interactions. Based on the resulting reconstructed particles and their kinematics, we also achieve 15-20% energy reconstruction resolutions for charged-current neutrino interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light detection with power and signal transmission over fiber

The Deep Underground Neutrino Experiment is a next generation long baseline (1300 km) neutrino oscillation experiment. The neutrino beam measurements will be performed by a near detector and far detector. The far detector will consist of four modules, installed 1.5 km deep underground, based on Liquid Argon Time Projection Chamber (LArTPC) technology to detect particles. The Vertical Drift (VD) LArTPC is a recent technology proposed by the DUNE collaboration for the second FD module. In VD, light collection will be optimized by embedding photon detectors within the LArTPC cathode, which is biased at −300 kV. As a result, power must arrive to the Photon Detection System and signal must be transmitted via non-conductive material. The proposed solution is to use Power-over-Fiber and Signal-over-Fiber. An intense validation of the system is being performed by the collaboration at the CERN Neutrino Platform. The design of the system and the results of the validation collected over the first half of 2022 are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection efficiency measurement and operational tests of the X-Arapuca for the first module of DUNE far detector

The Deep Underground Neutrino Experiment (DUNE) is a dual-site experiment for long-baseline neutrino oscillation studies, able to resolve the neutrino mass hierarchy and measure δ$_{CP}$. DUNE will also have sensitivity to supernova neutrinos and to processes beyond the Standard Model, such as nucleon decay searches. The Far Detector (FD) will consist of four liquid argon TPC (17.5 kt total mass) with systems for the detection of charge and scintillation light produced by an ionization event. The charge detection system permits both calorimetry and position determination. In addition, the photon-detection system (PDS) enhances the detector capabilities for all DUNE physics drivers. The PDS of the first FD module consists of light collector modules placed in the inactive space between the innermost wire planes of the TPC anode. The light collectors, the so-called X-ARAPUCAS, are functionally a light trap that captures wavelength-shifted photons inside boxes with highly reflective internal surfaces where they are guided to Silicon Photo-multipliers (SiPM) by wavelength-shifting (WLS) bars. Functionality and operational tests of the X-ARAPUCAS to be installed in ProtoDUNE-SP phase II (FD DUNE prototype at the scale 1:20), as well as the measurement of their absolute detection efficiency is reported in this publication.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

Production and testing of the large-area photon detector ArCLight

Compact large-area dielectric photon detectors that ensure modular noble liquid detectors can sense scintillation light signals for triggering and reconstruction purposes with minimal impact to the overall target volume. ArCLight is a small-volume, sizeable sensitive-area detector that consists of a light trap covered in a thin layer of TPB that can be placed inside a time projection chamber's electric field. These sensors are used in the Deep Underground Neutrino Experiment Near Detector liquid argon (DUNE ND-LAr). They are constructed and tested at the University of Bern and will be deployed in the prototype experiment ProtoDUNE-ND. The talk discusses the details of assembling ArCLights, the quality control methods, and the test studies done with LEDs to assess their performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon energy reconstruction for applications in neutrino astronomy in the DUNE far detector

Abstract DUNE (Deep Underground Neutrino Experiment) is a proposed long-baseline neutrino oscillation experiment located in the United States. The main physics objectives of DUNE are to measure neutrino oscillations and interactions, search for nucleon decay, observe supernova neutrino bursts and beyond Standard Model (BSM) effects. The DUNE far detector will be located 4850 feet underground at the Sanford Underground Research Facility in Lead, South Dakota. It will house the world's largest liquid-argon time projection chambers (TPC). The DUNE far detector can detect high-energy leptons that arise from interactions of cosmogenic neutrinos and search for neutrinos originating from the decay of weakly-interactive massive particles (WIMPs) annihilations occurring inside the Sun. Selecting upward-going muons reduces the background from cosmic-ray muons. The muon energy is estimated from the electromagnetic showers accompanying the muon, a technique that allows energy reconstruction up to a few hundred TeV.

Instruments & Instrumentation↗

Deep neural network uncertainty quantification for LArTPC reconstruction

We evaluate uncertainty quantification (UQ) methods for deep learning applied to liquid argon time projection chamber (LArTPC) physics analysis tasks. As deep learning applications enter widespread usage among physics data analysis, neural networks with reliable estimates of prediction uncertainty and robust performance against overconfidence and out-of-distribution (OOD) samples are critical for their full deployment in analyzing experimental data. While numerous UQ methods have been tested on simple datasets, performance evaluations for more complex tasks and datasets are scarce. Here we assess the application of selected deep learning UQ methods on the task of particle classification using the PiLArNet monte carlo 3D LArTPC point cloud dataset. We observe that UQ methods not only allow for better rejection of prediction mistakes and OOD detection, but also generally achieve higher overall accuracy across different task settings. We assess the precision of uncertainty quantification using different evaluation metrics, such as distributional separation of prediction entropy across correctly and incorrectly identified samples, receiver operating characteristic curves (ROCs), and expected calibration error from observed empirical accuracy. We conclude that ensembling methods can obtain well calibrated classification probabilities and generally perform better than other existing methods in deep learning UQ literature.

47 OTHER INSTRUMENTATION↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waveform resampling with LMN method

In this article, resampling is a common technique applied in digital signal processing. Based on the Fast Fourier Transformation (FFT), we apply an optimization called here the LMN method to achieve fast and robust re-sampling. In addition to performance comparisons with some other popular methods, we illustrate the effectiveness of this LMN method in a particle physics experiment: re-sampling of waveforms from Liquid Argon Time Projection Chambers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Updated parameters of the LArQL model

The need for a microscopic description of scintillation light generation in liquid argon becomes increasingly desirable with the upcoming operation of large scale LArTPCs in the next decade. While a detailed mathematical account of the process is still to be achieved, a phenomenological model for simultaneously treating ionization and scintillation, LArQL, has been successfully employed to describe the range of electric fields from 0 to 0.75 kV/cm and dE/dx from 2 to 40 MeV/cm providing the anti-correlation between the free ionization charge and scintillation light. A reanalysis of the original model parameter values has been performed within a global fit procedure and is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving ICARUS track reconstruction algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino program at Fermilab. Its primary objective is to explore the possible existence of sterile neutrinos in the O(1 eV) mass range and to clarify the anomalies observed in the Liquid Scintillator Neutrino Detector and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber, capable of producing high-resolution 3D images and precise calorimetric measurements of ionizing particles. This technology allows for a detailed study of neutrino interactions across a broad energy range, from a few keV to several hundred GeV. The track reconstruction is achieved through a software framework that applies a series of pattern recognition algorithms, transforming raw detector signals into fully reconstructed event topologies. This process involves identifying interaction vertices, particle tracks, and electromagnetic showers within the TPC. However, in certain cases, these algorithms may mistakenly break a single particle track into several shorter segments, interpreting each as a distinct particle. Since track length is used to estimate the particle's energy, such fragmentation can result in an energy underestimation of several hundred MeV. Furthermore, when a track is split into multiple segments, the particle identification (which relies on analyzing the energy loss as a function of the residual range) may fail, potentially leading to the loss of the entire event. To mitigate this problem, we have developed a dedicated algorithm designed to identify and reconnect (“stitch”) the tracks that were erroneously divided into multiple segments.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Preliminary design of a helium cryogenic system for SAND detector at LBNF-DUNE near site

The Long-Baseline Neutrino Facility (LBNF) is providing a helium cryogenic system to support the superconducting solenoid magnet of the System for on-Axis Neutrino Detection (SAND) for the Deep Underground Neutrino Experiment (DUNE) Near Site at Fermilab in Batavia, IL. The design started in 2020 and construction is set to begin in the mid 2020‘s.The helium cryogenic system primarily consists of a helium refrigerator system, distribution valve boxes, vacuum-jacketed helium and nitrogen transfer lines, warm gaseous helium transfer system, instruments and control system, and gaseous helium storage tanks. It is designed to provide supercritical helium at around 3 bara and 5 K with expansion from 3 to 1.2 bara in the SAND cryostat and 70K forced cold gas helium to cool the thermal shields of the SAND cryostat. The SAND superconductive magnet is indirectly cooled through a liquid helium thermosiphon cycle. A pair of 3 kA leads is cooled by the gas helium vaporized from the liquid helium reservoir in the cryostat turret. The helium system will share the liquid nitrogen tank and liquid nitrogen phase separator with the Near Site Liquid Argon system. The helium recycle compressor system, GHe tanks and LN2 tank will be located on the Surface. The cryogenic facilities including refrigerator cold box, valve boxes and LN2 phase separator will be located on the shaft cryo-mezzanine in the underground cavern. The shaft connecting surface and cavern is more than 60 meter deep. The helium vacuum-jacketed transfer line between the cold box and the SAND magnet is more than 50 meter long. This paper presents the preliminary design of the helium cryogenic system including the design scheme, process flow diagram, heat load estimates, layout plan and so on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results on the Search for Lepton Number Violating Neutrinoless Double-𝛽 Decay with the LEGEND-200 Experiment

The LEGEND Collaboration is searching for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay by operating high-purity germanium detectors enriched in 76 Ge in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0⁢𝜈⁢𝛽⁢𝛽 decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5$^{+0.3}_{−0.2}$ ⁢cts/(keV ton yr) in the 0⁢𝜈⁢𝛽⁢𝛽 decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 ×10 26 yr on the half-life of 0⁢𝜈⁢𝛽⁢𝛽 decay, reveals no evidence for a signal and sets a new observed lower limit at 𝑇$^{⁢0𝜈}_{1/2}$ > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range 𝑚 𝛽⁢𝛽 < 75–200 meV, depending on the adopted nuclear matrix element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward a Robust Confirmation or Refutation of the Sterile-Neutrino Explanation of Short-Baseline Anomalies

The sterile neutrino interpretation of the LSND and MiniBooNE neutrino anomalies is currently being tested at three liquid argon detectors: MicroBooNE, SBND, and ICARUS. It has been argued that a degeneracy between 𝜈 𝜇 → 𝜈 𝑒 and 𝜈 𝑒 → 𝜈 𝑒 oscillations significantly degrades their sensitivity to sterile neutrinos. Through an independent study, we show two methods to eliminate this concern. First, we resolve this degeneracy by including external constraints on 𝜈𝑒 disappearance from the PROSPECT reactor experiment. Second, by properly analyzing the full three-dimensional parameter space, we demonstrate that the stronger-than-sensitivity exclusion from MicroBooNE alone already covers the entire 2⁢𝜎 preferred regions of MiniBooNE at the level of 2−3⁢𝜎. We show that upcoming searches at SBND and ICARUS can improve on this beyond the 4⁢𝜎 level, thereby providing a rigorous test of short-baseline anomalies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of magnetic dipole strength in 40 Ar between 9.3 and 10.3 MeV excitation energy and impact on neutral current neutrino interaction

The magnetic dipole strength 𝐵⁡(𝑀⁢1 ↑) of 40 Ar was measured in the excitation energy range between 9.3 and 10.3 MeV. The nuclear resonance fluorescence technique was used with monoenergetic, linearly polarized incident photon beams. The new data increase the known 𝐵⁡(𝑀⁢1 ↑) strength in this important excitation energy range by a factor of 2, resulting in an equivalent increase of the calculated neutral current neutrino cross section of 40 Ar . This observation is of special interest for liquid-argon (LAr)-based neutrino detectors. 𝐵⁡(𝑀⁢1 ↑) strength has not been found between 10.3 and 11.7 MeV excitation energy. In conclusion, with the new data, a more reliable detection capability of the large Deep Underground Neutrino Experiment LAr detectors can be derived for potential core-collapse supernova neutrinos via the neutral current interaction.

Energy levels↗

Search for the production of Higgs-portal scalar bosons in the NuMI beam using the MicroBooNE detector

We present the strongest experimental limits to date on the mixing angle, 𝜃, with which a new scalar particle, 𝑆, mixes with the Higgs field in the mass range 110 MeV < 𝑚 𝑆 <155 MeV. This result uses the MicroBooNE liquid argon time projection chamber to search for decays of these Higgs-portal scalar particles through the 𝑆 → 𝑒 + ⁢𝑒 − channel with the decays of kaons in the NuMI neutrino beam acting as the source of the scalar particles. The analysis uses an exposure of 2.01 × 10 21 protons on target of NuMI beam data including periods when the beam focusing system was configured to focus positively charged hadrons and separate periods when negatively charged hadrons were focused. The analysis searches for scalar particles produced from kaons decaying in flight in the beam’s decay volume and at rest in the target and absorber. At 𝑚 𝑆 =125 MeV (𝑚 𝑆 =150 MeV) we set a limit of 𝜃 < 3.19 ×10 −4 (𝜃 < 2.79 ×10 −4 ) at the 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimal transport for 𝑒/𝜋 0 particle classification in LArTPC neutrino experiments

The efficient classification of electromagnetic activity from 𝜋 0 and electrons remains an open problem in the reconstruction of neutrino interactions in liquid argon time projection chamber (LArTPC) detectors. We address this problem using the mathematical framework of optimal transport (OT), which has been successfully employed for event classification in other high energy physics contexts and is ideally suited to the high-resolution calorimetry of LArTPCs. Using a publicly available simulated dataset from the MicroBooNE Collaboration, we show that OT methods achieve state-of-the-art reconstruction performance in 𝑒/𝜋 0 classification. The success of this first application indicates the broader promise of OT methods for LArTPC-based neutrino experiments.

Neutrino detection↗