Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Cryogenic X-ray crystallographic studies of biomacromolecules at Turkish Light Source " Turkish DeLight "

X-ray crystallography is a robust and powerful structural biology technique that provides high-resolution atomic structures of biomacromolecules. Scientists use this technique to unravel mechanistic and structural details of biological macromolecules (e.g., proteins, nucleic acids, protein complexes, protein-nucleic acid complexes, or large biological compartments). Since its inception, single-crystal cryocrystallography has never been performed in Türkiye due to the lack of a single-crystal X-ray diffractometer. The X-ray diffraction facility recently established at the University of Health Sciences, Istanbul, Türkiye will enable Turkish and international researchers to easily perform high-resolution structural analysis of biomacromolecules from single crystals. Here, we describe the technical and practical outlook of a state-of-the-art home-source X-ray, using lysozyme as a model protein. The methods and practice described in this article can be applied to any biological sample for structural studies. Therefore, this article will be a valuable practical guide from sample preparation to data analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Preliminary Commissioning and Performance of the Soft X-ray Micro-characterization Beamline at the Canadian Light Source

The Soft X-ray Micro-characterization Beamline (SXRMB) is a medium energy, bending magnet based beamline, designed to cover an energy range of 1.7-10 keV using two sets of crystals--InSb(111) and Si(111). The design goal is to deliver a flux of 2x10{sup 11} photons sec{sup -1}/100 mA with a resolution up to 10,000 for X-ray Absorption Spectroscopy. A KB mirror stage is designed to provide microprobe capability, with a spot size of 10x10 {mu}m{sup 2} and a flux of >10{sup 9} at the microprobe station. The beamline has been in the commissioning phase since 2008, and access to the X-ray absorption endstation is now open to general users. The optical commissioning and performance of the beamline is presented with some early experimental results.

43 PARTICLE ACCELERATORS↗

2-3 {mu}m mid infrared light sources using InGaAs/GaAsSb ''W'' type quantum wells on InP substrates

We have investigated the InGaAs/GaAsSb/InAlGaAs/InAlAs type-II ''W'' quantum wells (QWs) grown on InP substrates by molecular beam epitaxy. The photoluminescence (PL) emission wavelength longer than 2.56 {mu}m at room temperature (RT) is demonstrated for the first time in this material system. The PL emission peaks of our designed samples can cover a wide range from 2 to 2.5 {mu}m at cryogenic temperature. The samples show good optical quality that the reduction in integrated PL intensity is only around one order of magnitude from 35 K to RT. We found that the integrated PL intensity decreased as the emission wavelength increased, which is due to the reduction in the electron-hole wave function overlap. This is consistent with the calculated result. In the power dependent PL measurements, the emission peak of ''W'' type QWs show blue shifts with the excitation power (P{sub ex}) but does not follow the P{sub ex}{sup 1/3} rule as predicted by type-II band bending model. The localized states filling effect gives reasonable explanations for the observed phenomena.

36 MATERIALS SCIENCE↗

Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II

In this work, we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.

36 MATERIALS SCIENCE↗

Plasma dynamics of a confined extreme ultraviolet light source

Laser plasmas were generated by ablation of aluminum targets via a Nd:YAG glass laser, of pulse energy 0.8 J, and duration 15 ns (full width at half maximum) at the fundamental wavelength (1.064 {mu}m). Emission lines in the wavelength range of 27-32 nm (45-37.8 eV) were mapped over a spatial range extending out 1.8 mm from the target surface and for a temporal range of 42 ns after the termination of the laser pulse. Two targets were utilized: a planar surface and a rectangular cavity. The latter was composed of a rectangular shaped cavity of depth 3 mm and height 1.2 mm, cut into an aluminum massive. An irradiance of I{sub p{approx}}10{sup 11} W/cm{sup 2} was delivered to both targets and the confining influence of the rectangular cavity upon plasma formation and expansion was studied. Diagnostics of the emitted spectra reveal the unique dynamics of restricted plasma plume expansion, which results in plasma-surface collisions and subsequent plasma rebound within the cavity. These effects give rise to strong enhancement of both continuum and line emission in the contained plasma plume. These enhancements are especially evident for the more highly charged ions. Superior emission from plasma-surface collisions are associated with ''forced recombination'' during early time scales, while enhanced emission at later stages are associated with plasma plume component rebound and collision.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser Safety for the Experimental Halls at SLAC_s Linac Coherent Light Source (LCLS)

The LCLS at the SLAC National Accelerator Laboratory will be the world's first source of an intense hard x-ray laser beam, generating x-rays with wavelengths of 1nm and pulse durations less than 100fs. The ultrafast x-ray pulses will be used in pump-probe experiments to take stop-motion pictures of atoms and molecules in motion, with pulses powerful enough to take diffraction images of single molecules, enabling scientists to elucidate fundamental processes of chemistry and biology. Ultrafast conventional lasers will be used as the pump. In 2009, LCLS will deliver beam to the Atomic Molecular and Optical (AMO) Experiment, located in one of 3 x-ray Hutches in the Near Experimental Hall (NEH). The NEH includes a centralized Laser Hall, containing up to three Class 4 laser systems, three x-ray Hutches for experiments and vacuum transport tubes for delivering laser beams to the Hutches. The main components of the NEH laser systems are a Ti:sapphire oscillator, a regen amplifier, green pump lasers for the oscillator and regen, a pulse compressor and a harmonics conversion unit. Laser safety considerations and controls for the ultrafast laser beams, multiple laser controlled areas, and user facility issues are discussed.

43 PARTICLE ACCELERATORS↗

The Physics of the Gas Attenuator for the Linac Coherent Light Source (LCLS)

A systematic assessment of a variety of physics issues affecting the performance of the LCLS X-ray beam attenuator is presented. Detailed analysis of the gas flow in the gas attenuator and in the apertures is performed. A lot of attention is directed towards the gas ionization and heating by intense X-ray pulses. The role of these phenomena in possible deviations of the attenuation coefficient from its 'dialed in' value is evaluated and found small in most cases. Other sources of systematic and statistical errors are also discussed. The regimes where the errors may reach a few percent correspond to the lower X-ray energies (less than 2 keV) and highest beam intensities. Other effects discussed include chemical interaction of the gas with apertures, shock formation in the transonic flow in the apertures of the attenuator, generation of electromagnetic wakes in the gas, and head-to-tail variation of the attenuation caused by the ionization of gas or solid. Possible experimental tests of the consistency of the physics assumptions used in the concept of the gas attenuator are discussed. Interaction of X-rays with the solid attenuator (that will be used at higher X-ray energies, from 2.5 to 8 keV) is considered and thermo-mechanical effects caused by the beam heating are evaluated. Wave-front distortions induced by non-uniform heating of both the solid and the gas are found to be small. An overall conclusion drawn from the analysis presented is that the attenuator will be a reliable and highly versatile device, provided that some caution is exercised in its use for highest beam intensities at lowest X-ray energies.

43 PARTICLE ACCELERATORS↗

Light sources with bias tunable spectrum based on van der Waals interface transistors

Light-emitting electronic devices are ubiquitous in key areas of current technology, such as data communications, solid-state lighting, displays, and optical interconnects. Controlling the spectrum of the emitted light electrically, by simply acting on the device bias conditions, is an important goal with potential technological repercussions. However, identifying a material platform enabling broad electrical tuning of the spectrum of electroluminescent devices remains challenging. Here, we propose light-emitting field-effect transistors based on van der Waals interfaces of atomically thin semiconductors as a promising class of devices to achieve this goal. We demonstrate that large spectral changes in room-temperature electroluminescence can be controlled both at the device assembly stage –by suitably selecting the material forming the interfaces– and on-chip, by changing the bias to modify the device operation point. Even though the precise relation between device bias and kinetics of the radiative transitions remains to be understood, our experiments show that the physical mechanism responsible for light emission is robust, making these devices compatible with simple large areas device production methods.

36 MATERIALS SCIENCE↗

Optimizing spectral and morphological match of nonfullerene acceptors toward efficient indoor organic photovoltaics with enhanced light source adaptability

High-performance indoor organic photovoltaics (IOPV) require large-bandgap material systems to absorb visible light efficiently and reduce energy loss. However, state-of-the-art non-fullerene acceptors (NFAs) have absorptions in the near-infrared region and are thus not suitable for IOPV applications. Herein, we report a series of large-bandgap (>1.70 eV) NFAs named FCC-Cl-C8, FCC-Cl-4Ph and FCC-Cl-6Ph by modifying the alkyl side chains with alkylphenyl chains partially or completely. Results show that the bulky alkylphenyl side chains can finely tune the absorption properties of the NFAs and also affect their morphological properties. Interestingly, the best-performing NFA is the one (named FCC-Cl-4Ph) with partial alkyl and alkylphenyl substitutions, which blue-shift the absorption of the NFAs while minimizing the negative morphological effect of the bulky alkylphenyl chains. As a result, FCC-Cl-4Ph can achieve excellent indoor efficiencies over 29% under a 3000 K LED lamp at 1000 lux and show better solution processability over FCC-Cl-C8. More importantly, FCC-Cl-4Ph can maintain high indoor performance (29.7–26.8% at 1000 lux) under a wide range of indoor lighting spectra (2600, 3000, 4000, and 6500 K LED lamps), which should be due to the blue-shifted spectra of FCC-Cl-4Ph and better matching with various indoor conditions. Finally, this work reveals an interesting structure-property relationship and offers useful strategies for the further design of NFAs toward efficient IOPV devices.

14 SOLAR ENERGY↗

Metasurface-based multi-harmonic free-electron light source

Metasurfaces are subwavelength spatial variations in geometry and material where the structures are of negligible thickness compared to the wavelength of light and are optimized for far-field applications, such as controlling the wavefronts of electromagnetic waves. Here, we investigate the potential of the metasurface near-field profile, generated by an incident few-cycle pulse laser, to facilitate the generation of high-frequency light from free electrons. In particular, the metasurface near-field contains higher-order spatial harmonics that can be leveraged to generate multiple higher-harmonic X-ray frequency peaks. We show that the X-ray spectral profile can be arbitrarily shaped by controlling the metasurface geometry, the electron energy, and the incidence angle of the laser input. Using ab initio simulations, we predict bright and monoenergetic X-rays, achieving energies of 30 keV (with harmonics spaced by 3 keV) from 5-MeV electrons using 3.4-eV plasmon polaritons on a metasurface with a period of 85 nm. As an example, we present the design of a four-color X-ray source, a potential candidate for tabletop multicolor hard X-ray spectroscopy. Our developments could help pave the way for compact multi-harmonic sources of high-energy photons, which have potential applications in industry, medicine, and the fundamental sciences.

36 MATERIALS SCIENCE↗

Polymer and small molecule based hybrid light source

An organic electroluminescent device, includes: a substrate; a hole-injecting electrode (anode) coated over the substrate; a hole injection layer coated over the anode; a hole transporting layer coated over the hole injection layer; a polymer based light emitting layer, coated over the hole transporting layer; a small molecule based light emitting layer, thermally evaporated over the polymer based light emitting layer; and an electron-injecting electrode (cathode) deposited over the electroluminescent polymer layer.

Choong, Vi-En↗

Configurable luminaire with light sources variably oriented with respect to an array of concave mirrors

An array of LEDs is supported by a support mechanism that both supports conductors leading to the LEDs and sinks heat from the LEDs. The support mechanism may be a transparent heat-conducting sheet or an array of cantilevered arms at different angles that support the LEDs and sink heat. This reduces the blockage of light. The LEDs are positioned generally in the focal plane of an array of concave mirrors that collimate the light. The LEDs and array of mirrors are translatable with respect to one another to steer the aggregate light beam to customize the emission. The LEDs may be variably oriented with respect to the associated mirror apertures so as to create different light beams emitted from different ones of the mirrors.

42 ENGINEERING↗

Theoretical investigation of the spectrum and conversion efficiency of short wavelength extreme-ultraviolet light sources based on terbium plasmas

The emission spectrum and conversion efficiency of laser-produced terbium plasmas are theoretically investigated on the basis of computational atomic data. The theoretically calculated spectrum reproduces the main peak of observed spectrum at {lambda}=6.5 nm, which originates from 4d-4f transitions of near palladiumlike ions (Tb{sup 19+}). A simple model of the isothermal expansion of terbium plasma suggests that efficient emission can be achieved by pumping the plasma with a laser pulse at an intensity of approximately one order of magnitude greater than that used with tin sources at {lambda}=13.5 nm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vacuum-ultraviolet light source for enhanced production of metastable krypton and xenon beams

Here, we demonstrate excitation of metastable krypton and xenon beams using a vacuum ultraviolet lamp and directly compare the performance of this method to metastable excitation based on a radio-frequency-driven plasma discharge. In our apparatus, lamp-based metastable excitation outperforms the plasma discharge across a wide range of beam flux values relevant for atom trap trace analysis (ATTA). Moreover, we do not observe significant degradation in lamp performance after over 160 h of operation. We find that lamp-based excitation is particularly advantageous at the smallest and largest beam fluxes tested, demonstrating the utility of this approach both for improving krypton ATTA and for enabling the detection of radioactive xenon isotopes using ATTA. Finally, we demonstrate an additional enhancement to lamp-based metastable excitation efficiency and stability by applying an external magnetic field.

Metastable noble gases↗