Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lasers sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Surface-binding molecular multipods strengthen the halide perovskite lattice and boost luminescence

Reducing the size of perovskite crystals to confine excitons and passivating surface defects has fueled a significant advance in the luminescence efficiency of perovskite light-emitting diodes (LEDs). However, the persistent gap between the optical limit of electroluminescence efficiency and the photoluminescence efficiency of colloidal perovskite nanocrystals (PeNCs) suggests that defect passivation alone is not sufficient to achieve highly efficient colloidal PeNC-LEDs. Here, we present a materials approach to controlling the dynamic nature of the perovskite surface. Our experimental and theoretical studies reveal that conjugated molecular multipods (CMMs) adsorb onto the perovskite surface by multipodal hydrogen bonding and van der Waals interactions, strengthening the near-surface perovskite lattice and reducing ionic fluctuations which are related to nonradiative recombination. The CMM treatment strengthens the perovskite lattice and suppresses its dynamic disorder, resulting in a near-unity photoluminescence quantum yield of PeNC films and a high external quantum efficiency (26.1%) of PeNC-LED with pure green emission that matches the Rec.2020 color standard for next-generation vivid displays.

36 MATERIALS SCIENCE↗

Colloidal quantum dot lasers

We report semiconductor nanocrystals represent a promising class of solution-processable optical-gain media that can be manipulated via inexpensive, easily scalable colloidal techniques. Due to their extremely small sizes (typically <10 nm), their properties can be directly controlled via effects of quantum confinement; therefore, they are often termed colloidal quantum dots (CQDs). In addition to size-tunable emission wavelengths, CQDs offer other benefits for lasing applications, including low optical-gain thresholds and high temperature stability of lasing characteristics. Recent progress in understanding and practical control of processes impeding light amplification in CQDs has resulted in several breakthroughs, including the demonstration of optically pumped continuous-wave lasing, the realization of optical gain with direct current electrical injection and the development of dual-function electroluminescent devices that also operate as optically pumped lasers. The purpose of this Review is to assess the status of the field of CQD lasing and discuss the existing challenges and opportunities. A particular focus is on approaches for suppressing nonradiative Auger recombination, novel optical-gain concepts enabled by strong exciton-exciton interactions and controlled CQD charging, effects of nanocrystal form factors on light amplification and practical architectures for realizing electrically pumped CQD lasers. This overview suggests that the accumulated knowledge, along with the approaches developed for manipulating the optical-gain properties of colloidal nanostructures, perfectly position the CQD field for successfully addressing a long-standing challenge: the realization of CQD-based laser diodes. Colloidal quantum dots are promising materials for realizing versatile, wavelength-tunable, solution-processed lasers. This Review surveys recent advances in colloidal quantum dot lasing, provides an in-depth analysis of outstanding challenges and discusses a path forward to implementing technologically viable lasing devices.

36 MATERIALS SCIENCE↗

A database of thermally activated delayed fluorescent molecules auto-generated from scientific literature with ChemDataExtractor

A database of thermally activated delayed fluorescent (TADF) molecules was automatically generated from the scientific literature. It consists of 25,482 data records with an overall precision of 82%. Among these, 5,349 records have chemical names in the form of SMILES strings which are represented with 91% accuracy; these are grouped in a subsidiary database. Each data record contains one of the following four properties: maximum emission wavelength (λ EM ), photoluminescence quantum yield (PLQY), singlet-triplet energy splitting (ΔE ST ), and delayed lifetime (τ D ). The databases were created through text mining using ChemDataExtractor, a chemistry-aware natural-language-processing toolkit, which has been adapted for TADF research. The text-mined corpus consisted of 2,733 papers from the Royal Society of Chemistry and Elsevier. To the best of our knowledge, these databases are the first databases that have been auto-generated for TADF molecules from existing publications. The databases have been publicly released for experimental and computational applications in the TADF research field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlated color temperature is not a suitable proxy for the biological potency of light

Using a simulation based on a real, five-channel tunable LED lighting system, we show that Correlated Color Temperature (CCT) is not a reasonable predictor of the biological potency of light, whether characterized with CIE melanopic Equivalent Daylight Illuminance (mel-EDI), Equivalent Melanopic Lux (EML) (a scalar multiple of mel-EDI), or Circadian Stimulus (CS). At a photopic corneal illuminance of 300 lx and Rf ≥ 70, spectra can vary in CS from 17 to 41% across CCTs from 2500 to 6000 K, and up to 23% at a single CCT, due to the choice of spectrum alone. The CS range is largest, and notably discontinuous, at a CCT of 3500 K, the location of the inflection point of the CS model. At a photopic corneal illuminance of 300 lx and Rf ≥ 70, mel-EDI can vary from 123 to 354 lx across CCTs from 2500 to 6000 K and can vary by up to 123 lx at a fixed CCT (e.g., 196 to 319 lx at 5000 K). The range of achievable mel-EDI increases as CCT increases and, on average, decreases as color fidelity, characterized with IES TM-30 Rf, increases. These data demonstrate that there is no easy mathematical conversion between CS and mel-EDI when a spectrally diverse spectra set of spectral power distributions is considered.

60 APPLIED LIFE SCIENCES↗

New reflections on hard X-ray photon-in/photon-out spectroscopy

Analysis of the electronic structure and local coordination of an element is an important aspect in the study of the chemical and physical properties of materials. This is particularly relevant at the nanoscale where new phases of matter may emerge below a critical size. X-ray emission spectroscopy (XES) at synchrotron radiation sources and free electron lasers has enriched the field of X-ray spectroscopy. Additionally, the spectroscopic techniques derived from the combination of X-ray absorption and emission spectroscopy (XAS–XES), such as resonant inelastic X-ray scattering (RIXS) and high energy resolution fluorescence detected (HERFD) XAS, are an ideal tool for the study of nanomaterials. New installations and beamline upgrades now often include wavelength dispersive instruments for the analysis of the emitted X-rays. With the growing use of XAS–XES, scientists are learning about the possibilities and pitfalls. We discuss some experimental aspects, assess the feasibility of measuring weak fluorescence lines in dilute, radiation sensitive samples, and present new experimental approaches for studying magnetic properties of colloidal nanoparticles directly in the liquid phase.

47 OTHER INSTRUMENTATION↗

Coherence imaging spectroscopy at Wendelstein 7-X for impurity flow measurements

In the last decade, Coherence Imaging Spectroscopy (CIS) has shown distinctive results in measuring ion flow velocities in the edge of magnetically confined plasma devices. Its 2D spatially resolved measurement capabilities and its high optical throughput are ideal for investigating the impurity behavior in the complex 3D magnetic island topology edge of Wendelstein 7-X (W7-X). However, a highly precise and stable calibration method is required for a reliable diagnostic operation. A new level of precision and stability has been achieved for the two CIS systems installed at W7-X with the use of a new calibration source, a continuous tunable laser commercially available only since 2015. A specific prototype model was successfully adapted to the challenging requirements of W7-X, granting high accuracy (±0.01 pm) and flexibility (spectral range: 450–650 nm) in the wavelength calibration required for measuring low-Z impurity ion flow velocities. These features opened up new investigation possibilities on temperature stability and wavelength response of the CIS components, allowing to fully characterize and validate the W7-X systems. The CIS diagnostic was operational throughout the last W7-X experimental campaign. Measured velocities on the order of ~20–30 km/s were observed, corroborated by comparisons with measurements with Mach probes.

47 OTHER INSTRUMENTATION↗

Wehnelt photoemission in an ultrafast electron microscope: Stability and usability

We tested and compared the stability and usability of three different cathode materials and configurations in a thermionic-based ultrafast electron microscope: (1) on-axis thermionic and photoemission from a custom 100 μm diameter LaB 6 source with a graphite guard ring, (2) off-axis photoemission from the Ni aperture surface of the Wehnelt electrode, and (3) on-axis thermionic and photoemission from a custom 200 μm diameter polycrystalline Ta source. For each cathode type and configuration, including the Ni Wehnelt aperture, we illustrate how the photoelectron beam-current stability is deleteriously impacted by simultaneous cooling of the source following thermionic heating. Furthermore, we demonstrate usability via collection of parallel- and convergent-beam electron diffraction patterns and by formation of the optimum probe size. We find that usability of the off-axis Ni Wehnelt-aperture photoemission is at least comparable to on-axis LaB 6 thermionic emission, as well as to on-axis photoemission [the heretofore conventional approach to ultrafast electron microscopy (UEM) in thermionic-based instruments]. However, the stability and achievable beam currents for off-axis photoemission from the Wehnelt aperture were superior to that of the other cathode types and configurations, regardless of the electron-emission mechanism. Beam-current stability for this configuration was found to be ±1% (one standard deviation from the mean) for 70 min (longest duration tested), and steady-state beam current was reached within the sampling-time resolution used here (~1 s) for 15 pA beam currents (i.e., 460 electrons per packet for a 200 kHz repetition rate). Repeatability and robustness of the steady-state condition were also found to be within ±1% of the mean. We discuss the implications of these findings for UEM imaging and diffraction experiments, for pulsed-beam damage measurements, and for practical switching between optimum conventional TEM and UEM operation within the same instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A database and meta-analysis on the performance of exploding pusher implosions conducted at OMEGA

A database of 222 exploding pusher implosions conducted at the OMEGA Laser Facility is presented. The dataset consists of glass-shell capsules filled with varying pressures of D 2 , T 2 , and 3 He, which were imploded using square laser pulses with intensities ranging from 1 to 1 × 10 15 W/cm 2 . The database includes measurements of bang times, ion temperatures, and yields from the DD, D 3 He, and DT fusion reactions. A semi-analytic exploding pusher model is introduced, which effectively captures the observed trends in the data. This model predicts that the measurements scale according to a power-law relation based on the initial capsule and laser conditions. A generalized power-law scaling relation is directly fit to each dataset, providing a useful interpolation of the entire database. Overall, the database provides a valuable resource to estimating bang times, temperatures, and yields for the design of future experiments. Additionally, it provides a diverse set of data for validating more advanced implosion physics models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RF antenna helicity dependent particle heating in a helicon source

Experiments have demonstrated that ion phenomena, such as the lower hybrid resonance, play an important role in helicon source operation. Damping of the slow branch of the bounded whistler wave at the edge of a helicon source (i.e. the Trivelpiece-Gould mode) has been correlated with the creation of energetic electrons, heating of ions at the plasma edge, and anisotropic ion heating. Here we present ion velocity distribution function measurements, electron density and temperature measurements, and magnetic fluctuation measurements on both sides of an m = |1| helical antenna in a helicon source as a function of the driving frequency, magnetic field strength, and magnetic field orientation relative to the antenna helicity. Significant electron and ion heating (up to two times larger) occurs on the side of the antenna consistent with the launch of the m = +1 mode. The electron and ion heating occurs within one electron skin depth of the plasma edge, where slow wave damping is expected. The source parameters for enhanced particle heating are also consistent with lower hybrid resonance effects, which can only occur for Trivelpiece-Gould wave excitation.

wave modes↗

Intrinsic nonlocality of spin- and polarization-resolved probabilities in strong-field quantum electrodynamics

Spin and polarization are central to precision tests of fundamental physics and for interpreting radiation from astrophysical sources and ultraintense laser-matter experiments. Here, focusing on the fundamental process of nonlinear Compton scattering, we demonstrate that a key assumption underlying current strong-field quantum electrodynamics models, i.e., that emission can be treated as an instantaneous random event sampled from a local differential rate, is inconsistent once emission angles, electron spin, and/or photon polarization are resolved. Namely, even in strictly constant and uniform fields , the resulting fully differential distribution is sign indefinite, yielding negative inferred probabilities. The physical reason is that the photon emission probability builds up over a finite length of the electron trajectory, the formation region, during which the electron direction changes by roughly the same small angle that defines the radiation cone. Therefore, we put forward a new method where we integrate over this formation region analytically to obtain a physically consistent electron spin and photon polarization model. We show that the implementation of our model is compatible with existing Monte Carlo and particle-in-cell workflows. Simulations of a GeV-class electron-laser collision accessible at current petawatt facilities and of emission in a pulsarlike magnetic field are shown to reveal spin and polarization patterns that differ even qualitatively from state-of-the-art local models. In particular, our new model predicts substantial angle-dependent circular photon polarization where the well-known collinear-emission approach yields none, and a pronounced helicity bias in the recoiling electrons absent from current predictions. These findings have direct implications for upcoming strong-field QED experiments and for interpreting polarized radiation from extreme astrophysical environments.

astrophysical electromagnetic fields↗

Optimizing MeV photon dose generation in laser-solid interactions via stable beam propagation

Bremsstrahlung MeV x rays with high doses are essential for radiography of dense objects. Intense, short-pulse laser-driven MeV x-ray sources offer a promising solution, but understanding how the dose scales with laser intensity is crucial for their development. While theory predicts a square root scaling with laser intensity, experimental verification has been hindered by significant shot-to-shot variations, often exacerbated by long preplasma scale lengths from low laser contrast. Here, we demonstrate low shot-to-shot dose variation and confirm the theoretical scaling using high-contrast OMEGA EP laser interactions with millimeter-thick tantalum foils, achieving MeV x-ray doses up to 5.4 rad at 1 m for E photon > 500 keV. Simulations reveal that the unique focal spot of the OMEGA EP laser enables efficient x-ray generation and reduced variability by facilitating deeper laser penetration into dense plasma, even with shorter preplasma scale lengths. Published by the American Physical Society 2025

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of < 200 µm as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade ( maximum $ρr$ = 139 g/cm 2 ) with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

47 OTHER INSTRUMENTATION↗

A multi-MeV alpha particle source via proton-boron fusion driven by a 10-GW tabletop laser

Nuclear fusion between protons and boron-11 nuclei has undergone a revival of interest thanks to the rapid progress in pulsed laser technology. Potential applications of such reaction range from controlled nuclear fusion to radiobiology and cancer therapy. A laser-driven fusion approach consists in the interaction of high-power, high-intensity pulses with H- and B-rich targets. We report on an experiment exploiting proton-boron fusion in CN-BN targets to obtain high-energy alpha particle beams (up to 5 MeV) using a very compact approach and a tabletop laser system with a peak power of ~10 GW, which can operate at high-repetition rate (up to 1 kHz). The secondary resonance in the cross section of proton-boron fusion (~150 keV in the center-of-mass frame) is exploited using a laser-based approach. The generated alpha particles are characterized in terms of energy, flux, and angular distribution using solid-state nuclear-track detectors, demonstrating a flux of ~10 5 particles per second at 10 Hz, and ~10 6 per second at 1 kHz. Hydrodynamic and particle-in-cell numerical simulations support our experimental findings. Potential impact of our approach on future spread of ultra-compact, multi-MeV alpha particle sources driven by moderate intensity (10 16 -10 17 W/cm 2 ) laser pulses is anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using statistical modeling to predict and understand fusion experiments

Over 300 cryogenic layered direct-drive inertial confinement fusion implosions have been successfully executed on the OMEGA Laser System in the last decade. However, extracting sufficient understanding from these experiments to develop new designs or to identify or mitigate degradation sources remains challenging. Recently, a statistical modeling approach was developed to successfully design and predict improved implosion experiments on OMEGA. Here, we show that one-dimensional simulations can be used to predict the outcomes of systematically perturbed three-dimensional simulations and that this statistical modeling approach can be used to identify or rule out physical mechanisms for some of the degradation sources observed on the OMEGA Laser System for direct-drive cryogenic inertial confinement fusion. In this instance, we investigate the fusion yield dependencies on the ion temperature asymmetries and laser beam size observed in experiments by comparing with trends in three-dimensional synthetic simulation databases. Using the statistical model on these systematically perturbed simulations, we find that the statistically inferred dependency on the measured ion temperature asymmetries is well explained by imposed ℓ =1 modes. However, we find that the dependency on the laser beam size is only dominated by the illumination non-uniformity for some extreme cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra-compact x-ray spectrometer for high-repetition-rate laser–plasma experiments

Here, we present in this work the development of an ultra-compact, multi-channel x-ray spectrometer (UCXS). This diagnostic has been specially built and adapted to perform at high-repetition-rate (>1 Hz) for high-intensity, short-pulse laser plasma experiments. X-ray filters of varying materials and thicknesses are chosen to provide spectral resolution up to ΔE ≈ 1 keV over the x-ray energy range of 1–30 keV. These filters are distributed over a total of 25 channels, where each x-ray filter is coupled to a single scintillator. The UCXS is designed to detect and resolve a large variety of laser-driven x-ray sources such as low energy bremsstrahlung emission, fluorescence, and betatron radiation (up to 30 keV). Preliminary results from commissioning experiments at the ABL laser facility at Colorado State University are provided.

47 OTHER INSTRUMENTATION↗

Streaked optical pyrometer for proton-driven isochoric heating experiments of solid and foam targets

We have designed, built, and calibrated an ultrafast streaked optical pyrometer (SOP) with ~5 ps resolution for measuring the time-resolved surface blackbody temperature of an isochorically heated plasma. The pyrometer is calibrated to measure temperatures from 0.5 eV to 25 eV, with the option of adding calibrated neutral density filters to observe hotter plasmas. We demonstrated the use of this pyrometer on isochoric heating experiments using laser-accelerated proton beams as an energy source at the $f$ /40 beamline of the Texas Petawatt Laser. We used the large focal spot size (~80 μm radius) of the $f$ /40 pulses to accelerate high numbers of ~MeV protons off 5 μm thick solid gold targets. During our experimental campaign, we heated 10 μm thick aluminum foil targets to 1–10 eV over a duration of 50 ps and also observed heating to ~2 eV in 100 μm thick 60 mg/cm 3 carbon foams using the SOP to measure both the temperature and heating timescale.

Equations of state↗

High Intensity Gamma-Ray Source(HIγS) Radiographic Experiments

High Intensity Gamma-ray Source (HIGS) is a Free-Electron Laser (FEL) based Compton back-scattering γ-ray source. The HIGS facility is located on the campus of Duke University and operated by Triangle Universities Nuclear Laboratory (TUNL).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗