Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A segmented ion engine design for solar electric propulsion systems

A new ion engine design, called a segmented ion engine, is described which is capable of reducing the required ion source life time for small body rendezvous missions from 18,000 h to about 8,000 h. The use of SAND ion optics for the engine accelerator system makes it possible to substantially reduce the cost of demonstrating the required engine endurance. It is concluded that a flight test of a 5-kW xenon ion propulsion system on the ELITE spacecraft would enormously reduce the cost and risk of using ion propulsion on a planetary vehicle by addressing systems level issues associated with flying a spacecraft radically different from conventional planetary vehicles.

Brophy, John R.↗

Molecular beam simulation of planetary atmospheric entry: Some recent results

Molecular beam sources for producing fast beams containing CO2 and atomic oxygen are discussed. Results pertinent to the design and calibration of mass spectrometer ion source for measurement of the Martian atmosphere during the free molecule portion of the entry trajectory are also presented. The shortcomings and advantages of the simulation technique are discussed. It is shown that an open cavity configuration retains sensitivity to atomic oxygen, provides reasonable signal enhancement from the stagnation effect, is not highly sensitive to pitch and yaw effects, and presents no unforeseen problems in measuring CO2 or atomic oxygen. The simulation techniques used provide assistance in designing, developing, and (potentially) in testing and calibrating the required flight instrument.

French, J. B.↗

Potential biomedical applications of ion beam technology

Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic pros-thesis fixtion, and dental implants.

Banks, B. A.↗

Potential biomedical applications of ion beam technology

Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic prosthesis fixation, and dental implants.

Banks, B. A.↗

Improved Hollow Cathode

Improved hollow cathode for neutral-beam injector ion sources rapidly started by dielectric breakdown of ignitor plug located at one end of open ended tube. Used in low-current ion implantation, milling, sputtering, and bombardment for surface treatment.

Aston, G.↗

A new approach to mass spectrometer measurements of thermospheric density

The gas sampling problem in satellite and high velocity probes was investigated by applying the theory of a drifting Maxwellian gas. A lens system using a free stream ion source was developed and experimentally evaluated over the pressure range of 0.00001 to 0.01 N/m sq (approx. 10 to the minus 7th power to 0.0001 torr). The source has high beam transparency, which minimizes gas-surface collisions within, or near, the ionization volume. It is shown that for high ion energy (60 eV), the extracted ion beam has an on-axis energy spread of less than 4 eV, and that 90 percent of the ions are within 2.5 deg of the beam axis. It is concluded that the molecular beam mass spectrometer concept, developed for gas density measurements in the upper atmosphere, substantially reduces gas-surface scattering and gas-surface reactions in the sample, and preserves the integrity of the gas sample during the analysis process. Studies show that both the Scout and Delta launch vehicles have adequate volume, control, velocity, and data acquisition capability necessary to obtain thermospheric number density in real time.

Melfi, L. T., Jr.↗

Multipole gas thruster design

The development of a low field strength multipole thruster operating on both argon and xenon is described. Experimental results were obtained with a 15-cm diameter multipole thruster and are presented for a wide range of discharge-chamber configurations. Minimum discharge losses were 300-350 eV/ion for argon and 200-250 eV/ion for xenon. Ion beam flatness parameters in the plane of the accelerator grid ranged from 0.85 to 0.93 for both propellants. Thruster performance is correlated for a range of ion chamber sizes and operating conditions as well as propellant type and accelerator system open area. A 30-cm diameter ion source designed and built using the procedure and theory presented here-in is shown capable of low discharge losses and flat ion-beam profiles without optimization. This indicates that by using the low field strength multipole design, as well as general performance correlation information provided herein, it should be possible to rapidly translate initial performance specifications into easily fabricated, high performance prototypes.

Isaacson, G. C.↗

Ion Dynamic Capture Experiments With The High Performance Antiproton Trap (HiPAT)

To take the first step towards using the energy produced from the matter-antimatter annihilation for propulsion applications, the NASA Marshall Space Flight Center (MSFC) Propulsion Research Center (PRC) has initiated a research activity examining the storage of low energy antiprotons. The High Performance Antiproton Trap (HiPAT) is an electromagnetic system (Penning-Malmberg design) consisting of a 4 Tesla superconductor, a high voltage electrode confinement system, and an ultra high vacuum test section. It has been designed with an ultimate goal of maintaining 10(exp 12) charged particles with a half-life of 18 days. Currently, this system is being evaluated experimentally using normal matter ions that are cheap to produce, relatively easy to handle, and provide a good indication of overall trap behavior (with the exception of assessing annihilation losses). The ions are produced via a positive hydrogen ion source and transported to HiPAT in a beam line equipped with electrostatic optics. The optics serve to both focus and gate the incoming ions, providing microsecond-timed beam pulses that are dynamically captured by cycling the HiPAT forward containment field like a "trap door". Initial dynamic capture experiments have been successfully performed with beam energy and currents set to 1.9 kV and 23 micro-amps, respectively. At these settings up to 2x10(exp 9) ions have been trapped during a single dynamic cycle.

Martin, James↗

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.↗

The plasma separator ion engine.

Plasma separator ion engine allowing optimization of ion source and accelerator system independently, showing gains in thrust and less propellant consumption

PLASMA ENGINE↗

Secondary Ion Mass Spectroscopy

Secondary Ion mass Spectroscopy (SIMS), as the name suggests, involves characterizing metallic and other materials trough the spectroscopic analysis of secondary ions emanating from the surface of the material to be characterized by the impact of the high energy primary ions. The primary ion source including the choice of its gun, voltage and current can be selected and used depending on the purpose of the analysis. In most instruments more than one primary ion gun is lined up to the sample stage and can be activated with selected accelerating parameters (voltage and beam intensity). The impingement of primary ions on to the sample surface generates positive, negative or neutral ions, electrons, atoms and atomic clusters. Majority of these sample fragments being neutral, could not be utilized as such fragments cannot be manipulated through the use of electromagnetic or electrostatic lenses. Secondary ions that are positively or negatively charged possess large variation in velocity, charge, and mass. These ionic fragments eventually travel through a system of several lenses in very high vacuum to reach detector/counter. Relative amounts of alloying elements or impurities in an alloy can be calculated from the counts of related ions accumulated in the detector/counter.

Panda, Binayak↗

Investigations of atomic and molecular processes of NBI-heated discharges in the MAST Upgrade Super-X divertor with implications for reactors

This experimental study presents an in-depth investigation of the performance of the MAST-U Super-X divertor during NBI-heated operation (up to 2.5 MW) focussing on volumetric ion sources and sinks as well as power losses during detachment. The particle balance and power loss analysis revealed the crucial role of Molecular Activated Recombination and Dissociation (MAR and MAD) ion sinks in divertor particle and power balance, which remain pronounced in the change from ohmic to higher power (NBI heated) L-mode conditions. The importance of MAR and MAD remains with double the absorbed NBI heating. MAD results in significant power dissipation (up to ${\sim} 20\%$ of $P_\textrm{SOL}$), mostly in the cold ($T_e \lt 5$ eV) detached region. Theoretical and experimental evidence is found for the potential contribution of $D^-$ to MAR and MAD, which warrants further study. These results suggest that MAR and MAD can be relevant in higher power conditions than the ohmic conditions studied previously. Post-processing reactor-scale simulations suggests that MAR and MAD can play a significant role in divertor physics and synthetic diagnostic signals of reactor-scale devices, which are currently underestimated in exhaust simulations. This raises implications for the accuracy of reactor-scale divertor simulations of particularly tightly baffled (alternative) divertor configurations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Factors controlling precision and accuracy in isotope-ratio-monitoring mass spectrometry

The performance of systems in which picomole quantities of sample are mixed with a carrier gas and passed through an isotope-ratio mass spectrometer system was examined experimentally and theoretically. Two different mass spectrometers were used, both having electron-impact ion sources and Faraday cup collector systems. One had an accelerating potential of 10kV and accepted 0.2 mL of He/min, producing, under those conditions, a maximum efficiency of 1 CO2 molecular ion collected per 700 molecules introduced. Comparable figures for the second instrument were 3 kV, 0.5 mL of He/min, and 14000 molecules/ion. Signal pathways were adjusted so that response times were <200 ms. Sample-related ion currents appeared as peaks with widths of 3-30 s. Isotope ratios were determined by comparison to signals produced by standard gases. In spite of rapid variations in signals, observed levels of performance were within a factor of 2 of shot-noise limits. For the 10-kV instrument, sample requirements for standard deviations of 0.1 and 0.5% were 45 and 1.7 pmol, respectively. Comparable requirements for the 3-kV instrument were 900 and 36 pmol. Drifts in instrumental characteristics were adequately neutralized when standards were observed at 20-min intervals. For the 10-kV instrument, computed isotopic compositions were independent of sample size and signal strength over the ranges examined. Nonlinearities of <0.04%/V were observed for the 3-kV system. Procedures for observation and subtraction of background ion currents were examined experimentally and theoretically. For sample/ background ratios varying from >10 to 0.3, precision is expected and observed to decrease approximately 2-fold and to depend only weakly on the precision with which background ion currents have been measured.

NASA Discipline Exobiology↗

Hollow cathode startup using a microplasma discharge

Attention is given to a microplasma discharge to initiate a hollow cathode discharge for such applications as plasma flow experiments, the electric propulsion of space vehicles, and as a replacement for filament cathodes in neutral beam injector ion sources. The technique results in a cathode that is easy to start, simple in design, and which does not require external RF exciters, inserts or heating elements. Future applications may include ion beam milling and ion implantation.

Aston, G.↗

Experimental and analytical ion thruster research

The results of further spectroscopic studies on the plume from a 3 cm ion source operated on an argon propellant is reported on. In particular, it is shown that it should be possible to use the spectroscopic technique to measure the plasma density of the ion plume close to the grids, where it is difficult to use electrical probe measurements. How the technique, along with electrical probe measurements in the far downstream region of the plume, can be used to characterize the operation of a three-grid, 15 cm diameter thruster from NASA JPL is outlined. Pumping speed measurements on the Vacuum Research Facility have shown that this facility should be adequate for testing the JPL thruster at pressures in the low 10(exp -5) Torr range. Finally, we describe a simple analytical model which can be used to calculate the grid impingement current which results from charge-exchange collisions in the ion plume.

Ruyten, Wilhelmus M.↗

Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting from Heavy Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation

Heavy ion, focused X-ray, pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. The transient shape characteristics depend on the source (ion, X-ray, or laser), even when similar amounts of charge are generated. The observed differences are examined and explained in terms of basic charge collection mechanisms.

Heavy ions↗

Advanced Characterization Techniques for Overcoming Challenges of Perovskite Solar Cell Materials

Abstract In the last 10 years, organic–inorganic hybrid perovskite solar cells have achieved unprecedented advances, to the point where they now exhibit extremely high efficiency. However, long‐term stability and areal scalability limitations impede the commercial application of perovskite materials, and appropriate diagnosistic tools have become necessary to evaluate perovskite materials. Characterization of perovskite materials is regularly misinterpretated, due to unique intrinsic and extrinsic factors: degradation from the measurement source, ion migration, phase transition, and separation. Herein, studies on perovskites are reviewed that have used advanced characterization tools to overcome characterization challenges. Cryogenic temperature assisted measurements mitigate degradation or phase transitions induced by the measurement source. In situ measurements can track the variation of perovskite materials depending on external stimuli. Spatial material properties are able to be evaluated by the use of multidimensional mapping techniques. An overview of these advanced characterization tools that can overcome the challenges associated with established tools provides the opportunity for further understanding perovskite materials and solving the remaining challenges on the road to commercialization.

Kim, Min‐cheol↗