Utility of Multi-institutional Pediatric Chart Rounds in the Age of Telemedicine
No abstract prepared.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
With the extensive application of IoT techniques, IoT devices have become ubiquitous in daily lives. Meanwhile, attacks against IoT devices have emerged to compromise IoT devices by tampering with system pre-installed programs or injecting new malware. To mitigate these attacks, integrity enforcement of IoT systems has been proposed. The integrity of an IoT device system includes load-time integrity and runtime integrity. In this paper, we design an IoT system based on ARM TrustZone to enforce the system integrity. First, we establish the root of trust and propose a hybrid booting approach consisting of both secure boot and trusted boot to enforce the system load-time integrity. Second, we investigate a paging-based process integrity measurement method to measure the NW processes and conduct remote attestation based on the measurement results ensuring the NW runtime process integrity. We implement an IoT prototype system on a NXP i.MX6Q SABRE SD development board to assess its feasibility. Finally, real-world experiment results demonstrate that our prototype introduces negligible performance overhead to the original system.
Chlorine incorporation in triple halide perovskites reduces trap density and enhances the efficiency of indoor light harvesting.
Not Available
Cyclic prefix direct sequence spread spectrum (CPDSSS) is a novel waveform with versatile characteristics that positions itself well as a secondary network to relieve the congested wireless spectrum. The underlying structure of CPDSSS allows for efficient and effective multi-access capabilites through frequency and time division schemes in a given system. The sum-rate capacity of the system is maximized when the spectrum is divided and allocated to users with the best signal-to-noise (SNR) ratio for the given channel slice. We propose an algorithm for dividing and allocating portions of the spectrum to multiple users with the final goal of maximizing the sumrate capacity of the network. We also propose and develop a precoding/equalization technique that reduces the length of the channel impulse response. This, when used along with a matched filter detector, leads to some improvement in the sum-rate capacity of the network
Not Available
As Radio Frequency Identification (RFID) methods continue to evolve to higher levels of complexity, one form of machine learning is making its appearance. The use of Neural Networks (NN) in the RFID field is steadily increasing, and in the fields of localization and activity recognition, promising results are being shown from a variety of research. RFID applications fall primarily under two types of problems including regression and classification. We analyze RIFD localization techniques which fall under regression, and activity recognition which falls under classification. Many works don’t classify themselves as activity recognition methods, but because they fall under the classification category, we still consider them as activity recognition techniques. This research overviews the Neural Network models in the localization field based on whether they can perform independently of the environment in which they were tested. For activity recognition and accessory fields, the major methods involve tag-based and tag-free approaches. In conclusion, after the models are surveyed, a comparison study is given to examine what may be the cause for increased accuracy between different Neural Network models.
Precision horticulture is evolving due to scalable sensor deployment and machine learning (ML) integration. These advancements boost the operational efficiency of individual farms, balancing the benefits of analytics with autonomy requirements. However, given concerns that affect wide geographic regions (e.g., climate change), there is a need to apply models that span farms. Federated learning (FL) has emerged as a potential solution. FL enables decentralized ML across different farms without sharing private data. Traditional FL assumes simple two-tier network topologies and, thus, falls short of operating on more complex networks found in real-world agricultural scenarios. Networks vary across crops and farms and encompass various sensor data modes, extending across jurisdictions. New hierarchical FL (HFL) approaches are needed for more efficient and context-sensitive model sharing, accommodating regulations across multiple jurisdictions. Here, we present the RuralAI architecture deployment for tomato crop monitoring, featuring sensor field units for soil, crop, and weather data collection. HFL with personalization is used to offer localized and adaptive insights. Model management, aggregation, and transfers are facilitated via a flexible approach, enabling seamless communication between local devices, edge nodes, and the cloud.
Machine condition monitoring has been proven to reduce machine downtime and increase productivity. The state-of-the-art research uses vibration monitoring for tasks such as maintenance and tool wear prediction. A less explored aspect is how vibration monitoring might be used to monitor equipment sensitive to vibration. In a manufacturing environment, one example of where this might be needed is in monitoring the vibration of optical linear encoders used in high-precision machine tools and coordinate measuring machines. Monitoring the vibration of sensitive equipment presents a unique case for vibration monitoring because an accurate calculation of the maximum sustained vibration is needed, as opposed to extracting trends from the data. To do this, techniques for determining sustained peaks in vibration signals are needed. Here, this work fills this gap by formalizing and testing methods for determining sustained vibration amplitudes. The methods are tested on simulated signals based on experimental data. Results show that processing the signal directly with the novel Expire Timer method produces the smallest amounts of error on average under various test conditions. Additionally, this method can operate in real-time on streaming vibration data.
This paper discusses the events leading up to, the instantiation in 1994 of the first permanent network connection between mainland China and the USA, and some of the impacts since.
Any major crisis such as the latest coronavirus disease pandemic will have a monumental effect on the worldwide economy and on the international supply chain. Much of the global supply chain relies on China, Germany, and the United States for manufacturing and distribution; this fragile system is subject to failure. Climactic changes in demand and rapid shortages in necessities are the results of the pandemic’s disruption. The recovery forecast for the ongoing pandemic is uncertain and, therefore, any recovery effort will need to be adaptable to build the supply chain resiliency. A wide adoption of flexible smart automated technologies in the manufacturing sector are helping to build robust supply chains and assisting in recovery. Here, a brief discussion of these smart manufacturing technologies is presented, along with a list of potential supply chain issues and corresponding solutions. Such smart manufacturing technologies possess the potential to empower and revolutionize the traditional manufacturing environment by enhancing its resiliency and flexibility. These smart technologies will play a crucial role in accelerating the worldwide supply chain recovery in and after a pandemic.
The percentage integration of photovoltaic (PV) inverters in the field has increased significantly in the past 5 years. Regardless of the size of the PV plants and the inverters (residential vs. commercial), it is becoming crucial that these devices have the capability to communicate with peers (other smart devices) and with components that are at a hierarchy above the inverters (e.g., supervisory control and data acquisition (SCADA) systems, distributed controllers, and data managers). This project aims to develop a standard SCADA software code for inverters’ embedded controllers that will enable interoperability with other components in the system. To achieve this, the code will be developed using two different protocols: Distributed Network Protocol 3 and International Electrotechnical Commission 61850. The developed code is aimed to be deployed in simple embedded controllers. It will be tested in the National Renewable Energy Laboratory’s (NREL’s) Energy Systems Integration Facility. The tested code will then be made available through Triangle MicroWorks’s (TMW’s) software platform. The primary objectives of this project include training the NREL team with TMW’s embedded controller libraries, developing an interoperable communication code for embedded controllers, successfully testing and deploying the code, and demonstrating the newly developed code in a conference.
Legacy devices across grid, transportation, and building systems present complex modernization challenges that extend far beyond simple equipment obsolescence. Pulling from presentations and break-out group discussions from this workshop on legacy devices across all three sectors, this report examines the interconnected factors driving replacement decisions, documents successful modernization initiatives from recent years, and provides strategic guidance for coordinating infrastructure transformation across these critical sectors.
Electric power systems provide the backbone of modern industrial societies. Enabling scalable grid analytics is the keystone to successfully operating large transmission and distribution systems. However, today's power systems are suffering from ever-increasing computational burdens in sustaining the expanding communities and deep integration of renewable energy resources, as well as managing huge volumes of data accordingly. These unprecedented challenges call for transformative analytics to support the resilient operations of power systems. Recently, the explosive growth of quantum computing techniques has ignited new hopes of revolutionizing power system computations. Quantum computing harnesses quantum mechanisms to solve traditionally intractable computational problems, which may lead to ultra-scalable and efficient power grid analytics. This paper reviews the newly emerging application of quantum computing techniques in power systems. We present a comprehensive overview of existing quantum-engineered power analytics from different operation perspectives, including static analysis, transient analysis, stochastic analysis, optimization, stability, and control. We thoroughly discuss the related quantum algorithms, their benefits and limitations, hardware implementations, and recommended practices. We also review the quantum networking techniques to ensure secure communication of power systems in the quantum era. Finally, we discuss challenges and future research directions. This paper will hopefully stimulate increasing attention to the development of quantum-engineered smart grids.
Existing approaches for allocating resources on edge environments are inefficient and lack the support of heterogeneous edge devices, which in turn fail to optimize the dependency on cloud infrastructures or datacenters. To this extent, we propose in this paper OpERA, a multi-layered edge-based resource allocation optimization framework that supports heterogeneous and seamless execution of offloadable tasks across edge, fog, and cloud computing layers and architectures. By capturing offloadable task requirements, OpERA is capable of identifying suitable resources within nearby edge or fog layers, thus optimizing the execution process. Throughout the paper, we present results which show the effectiveness of our proposed optimization strategy in terms of reducing costs, minimizing energy consumption, and promoting other residual gains in terms of processing computations, network bandwidth, and task execution time. We also demonstrate that by optimizing resource allocation in computation offloading, it is then possible to increase the likelihood of successful task offloading, particularly for computationally intensive tasks that are becoming integral as part of many IoT applications such robotic surgery, autonomous driving, smart city monitoring device grids, and deep learning tasks. The evaluation of our OpERA optimization algorithm reveals that the TOPSIS MCDM technique effectively identifies optimal compute resources for processing offloadable tasks, with a 96% success rate. Moreover, the results from our experiments with a diverse range of use cases show that our OpERA optimization strategy can effectively reduce energy consumption by up to 88%, and operational costs by 76%, by identifying relevant compute resources.
The convergence of Information Technologies and Operational Technology systems in industrial networks presents many challenges related to availability, integrity, and confidentiality. In this paper, we evaluate the various cybersecurity risks in industrial control systems and how they may affect these areas of concern, with a particular focus on energy-sector Operational Technology systems. There are multiple threats and countermeasures that Operational Technology and Information Technology systems share. Since Information Technology cybersecurity is a relatively mature field, this paper emphasizes on threats with particular applicability to Operational Technology and their respective countermeasures. We identify regulations, standards, frameworks and typical system architectures associated with this domain. We review relevant challenges, threats, and countermeasures, as well as critical differences in priorities between Information and Operational Technology cybersecurity efforts and implications. These results are then examined against the recommended National Institute of Standards and Technology framework for gap analysis to provide a complete approach to energy sector cybersecurity. We provide analysis of countermeasure implementation to align with the continuous functions recommended for a sound cybersecurity framework.
Fifth-generation networks promise wide availability of wireless communication with inherent security features. The 5G standards also outline access for different applications requiring low latency, machine-to-machine communication, or mobile broadband. These networks can be advantageous to numerous applications that require widespread and diverse communications. One such application is found in smart grids. Smart grid networks, and Operational Technology (OT) networks in general, utilize a variety of communication protocols for low-latency control, data monitoring, and reporting at every level. Transitioning these network communications from wired Wide Area Networks (WANs) to wireless communication through 5G can provide additional benefits to their security and network configurability. However, introducing these wireless capabilities may also result in a degradation of network latency. In this paper, we propose utilizing 5G for smart grid communications, and we evaluate the latency impacts of encapsulating GOOSE, Modbus, and DNP3 for transmission over a 5G network. The OpenAirInterface open-source library is utilized to deploy an in-lab 5G Core Network and gNB for testing with off-the-shelf User Equipment (UE). This creates an effective 5G test platform for experimenting with different OT protocols such as GOOSE. The results are validated by measuring two different Intelligent Electronic Devices’ contact closure times for each network configuration. These tests are also conducted for varying packet sizes in order to isolate different sources of network latency. Our study outlines the latency impact of communication over 5G for time-critical and non-critical applications regarding their transition toward private 5G-based OT network implementations. The conducted experiments illustrate that in the case of GOOSE packets, simple encapsulation may exceed the protocol’s time-critical nature, and, therefore, additional measures must be taken to ensure a viable transition of GOOSE to 5G services. However, non-critical applications are shown to be viable for migration to 5G.