Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Real-Time Vehicle-Mounted Multistatic Ground Penetrating Radar Imaging System for Buried Object Detection

A multistatic ground penetrating radar system is described, capable of real-time imaging and object detection. The radar consists of 16 transmitter and receiver pairs mounted across the front of a vehicle. The transmitters operate sequentially with all receivers activated for each transmit pulse. The resulting frame of 256 multistatic time signals is processed into an image using a tomographic reconstruction technique. In this paper we describe the system architecture, signal conditioning, and reconstruction algorithm for producing a sequence of images in real time as the vehicle travels across the ground. We demonstrate a robust image post-processing method that separates the bright spot corresponding to the dominant buried object in an image frame from the background. This is essential before calculating an energy-based statistic for automatic detection of buried objects. This spot ratio detection statistic, based on energy both inside and outside the spot, is shown to be not only more stationary than spot energy (i.e. mostly free of localized trends due to changing ground conditions), but also more powerful as a detection statistic. Finally, we demonstrate that multistatic imaging significantly improves the detection performance over more conventional monostatic array processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of radar imaging system parameters for geological analysis

The use of radar image simulation to model terrain variation and determine optimum sensor parameters for geological analysis is described. Optimum incidence angle is determined by the simulation, which evaluates separately the discrimination of surface features possible due to terrain geometry and that due to terrain scattering. Depending on the relative relief, slope, and scattering cross section, optimum incidence angle may vary from 20 to 80 degrees. Large incident angle imagery (more than 60 deg) is best for the widest range of geological applications, but in many cases these large angles cannot be achieved by satellite systems. Low relief regions require low incidence angles (less than 30 deg), so a satellite system serving a broad range of applications should have at least two selectable angles of incidence.

Waite, W. P.↗

Design, Testing, and Implementation of the Marshall Grazing Incidence X-ray Spectrometer Slit-Jaw Context Imaging System

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket payload providing a 0.6 – 2.5 nm spectrum with unprecedented spatial and spectral resolution. The instrument is comprised of a novel optical design, featuring a Wolter 1 grazing mirror in the telescope module focusing the solar image on a slit plate; two corrective optics, a diffraction grating and a low-noise detector make up the spectrometer module. When MaGIXS flies on a suborbital launch in 2020, a slit-jaw camera system will image the sun in extreme ultraviolet (EUV) to soft x-ray wavelengths, providing a reference for pointing the telescope and aligning the data to supporting observations from satellites.

Phillip Wilkerson↗

Preliminary Design Needs for High-Temperature Heat Pipe Imaging System

This report provides preliminary design needs for radiological imaging heat pipes to perform in operando assessment for high-temperature alkaline metal charged heat pipes (HPs). The measurement parameters of interest have been summarized for characterizing the operando HP behavior. Based on the current SPHERE experimental facility, the needs and modifications required for the experimental setup have also been identified to enable the X-ray-assisted visualizations for the single HP during its operating conditions.

42 ENGINEERING↗

A new ultrasonic imaging system using time delay spectrometry

A new method of forming a visual image by ultrasound is described. A shadowgraphic transmission image similar to an X-ray radiograph is produced by the application of a technique known as Time Delay Spectrometry. The system uses a repetitive frequency sweep with a linear relationship between frequency and time and the transmitting and receiving crystal are scanned in raster fashion about the subject. By electronic processing, an image may be built up which represents the energy transmitted through the specimen with a given time delay. An intensity modulated picture encompassing the full shades-of-gray capability of the recording system can be produced. A second type of image showing transmission time through the specimen may also be formed. Brightness changes in the displayed image in this case correspond to changes in the ultrasonic transmission time through the specimen.

Heyser, R. C.↗

A monochromatic x-ray imaging system for characterizing low-density foams

In High Energy Density (HED) laser experiments, targets often require small, low-density, foam components. However, their limited size can preclude single component characterization, forcing one to rely solely on less accurate bulk measurements. We have developed a monochromatic imaging a system to characterize both the density and uniformity of single component low-mass foams. This x-ray assembly is capable of determining line-averaged density variations near the 1% level, and provides statistically identical results to those obtained at the Brookhaven's NSLS. This system has the added benefit of providing two-dimensional density data, allowing an assessment of density uniformity.

47 OTHER INSTRUMENTATION↗

WE-EF-210-07: Development of a Minimally Invasive Photo Acoustic Imaging System for Early Prostate Cancer Detection

Purpose: The objective of this work is to design, implement and characterize a catheter-based ultrasound/photoacoustic imaging probe for early-diagnosis of prostate cancer and to aid in image-guided radiation therapy. Methods: The need to image across 6–10cm of tissue to image the whole prostate gland limits the resolution achievable with a transrectal ultrasound approach. In contrast, the urethra bisects the prostate gland, providing a minimally invasive pathway for deploying a high resolution ultrasound transducer. Utilizing a high-frequency (20MHz) ultrasound/photoacoustic probe, high-resolution structural and molecular imaging of the prostate tissue is possible. A custom 3D printed probe containing a high-frequency single-element ultrasound transducer is utilized. The diameter of the probe is designed to fit inside a Foley catheter and the probe is rotated around the central axis to achieve a circular B-scan. A custom ultrasound amplifier and receiver was set up to trigger the ultrasound pulse transmission and record the reflected signal. The reconstructed images were compared to images generated by traditional 5 MHz ultrasound transducers. Results: The preliminary results using the high-frequency ultrasound probe show that it is possible to resolve finely detailed information in a prostate tissue phantom that was not achievable with previous low-frequency ultrasound systems. Preliminary ultrasound imaging was performed on tissue mimicking phantom and sensitivity and signal-to-noise ratio of the catheter was measured. Conclusion: In order to achieve non-invasive, high-resolution, structural and molecular imaging for early-diagnosis and image-guided radiation therapy of the prostate tissue, a transurethral catheter was designed. Structural/molecular imaging using ultrasound/photoacoustic of the prostate tissue will allow for localization of hyper vascularized areas for early-stage prostate cancer diagnosis.

60 APPLIED LIFE SCIENCES↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

SU-E-J-134: An Augmented-Reality Optical Imaging System for Accurate Breast Positioning During Radiotherapy

Purpose: Breast radiotherapy, particularly electronic compensation, may involve large dose gradients and difficult patient positioning problems. We have developed a simple self-calibrating augmented-reality system, which assists in accurately and reproducibly positioning the patient, by displaying her live image from a single camera superimposed on the correct perspective projection of her 3D CT data. Our method requires only a standard digital camera capable of live-view mode, installed in the treatment suite at an approximately-known orientation and position (rotation R; translation T). Methods: A 10-sphere calibration jig was constructed and CT imaged to provide a 3D model. The (R,T) relating the camera to the CT coordinate system were determined by acquiring a photograph of the jig and optimizing an objective function, which compares the true image points to points calculated with a given candidate R and T geometry. Using this geometric information, 3D CT patient data, viewed from the camera's perspective, is plotted using a Matlab routine. This image data is superimposed onto the real-time patient image, acquired by the camera, and displayed using standard live-view software. This enables the therapists to view both the patient's current and desired positions, and guide the patient into assuming the correct position. The method was evaluated using an in-house developed bolus-like breast phantom, mounted on a supporting platform, which could be tilted at various angles to simulate treatment-like geometries. Results: Our system allowed breast phantom alignment, with an accuracy of about 0.5 cm and 1 ± 0.5 degree. Better resolution could be possible using a camera with higher-zoom capabilities. Conclusion: We have developed an augmented-reality system, which combines a perspective projection of a CT image with a patient's real-time optical image. This system has the potential to improve patient setup accuracy during breast radiotherapy, and could possibly be used for other disease sites as well.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Minimally Invasive Magnetic Resonance Imaging-Guided Free-Hand Aspiration of Symptomatic Nerve Route Compressing Lumbosacral Cysts Using a 1.0-Tesla Open Magnetic Resonance Imaging System

Purpose: To evaluate the feasibility of minimally invasive magnetic resonance imaging (MRI)-guided free-hand aspiration of symptomatic nerve route compressing lumbosacral cysts in a 1.0-Tesla (T) open MRI system using a tailored interactive sequence. Materials and Methods: Eleven patients with MRI-evident symptomatic cysts in the lumbosacral region and possible nerve route compressing character were referred to a 1.0-T open MRI system. For MRI interventional cyst aspiration, an interactive sequence was used, allowing for near real-time position validation of the needle in any desired three-dimensional plane. Results: Seven of 11 cysts in the lumbosacral region were successfully aspirated (average 10.1 mm [SD {+-} 1.9]). After successful cyst aspiration, each patient reported speedy relief of initial symptoms. Average cyst size was 9.6 mm ({+-}2.6 mm). Four cysts (8.8 {+-} 3.8 mm) could not be aspirated. Conclusion: Open MRI systems with tailored interactive sequences have great potential for cyst aspiration in the lumbosacral region. The authors perceive major advantages of the MR-guided cyst aspiration in its minimally invasive character compared to direct and open surgical options along with consecutive less trauma, less stress, and also less side-effects for the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aperture design for the third neutron and first gamma-ray imaging systems for the National Ignition Facility

The current construction of a new nuclear-imaging view at the National Ignition Facility will provide a third line of sight for hotspot and cold fuel imaging and the first dedicated line of sight for 4.4-MeV γ-ray imaging of the remaining carbon ablator. To minimize the effort required to hold and align apertures inside the vacuum chamber, the apertures for the two lines of sight will be contained in the same array. We discuss the system requirements for neutron and γ-ray imaging and the resulting aperture array design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid crystal polymer substrate MMIC receiver modules for the ECE Imaging system on the DIII-D

A new generation of millimeter-wave heterodyne imaging receiver arrays has been developed and demonstrated on the DIII-D ECEI system. Improved circuit integration, allowing for absolute calibration, improved noise performance, and shielding from out-of-band emission, is made possible by using advanced liquid crystal polymer (LCP) substrates and MMIC (Monolithic Microwave Integrated Circuit) receiver chips. This array exhibits ~ 15 dB additional gain and > 30x reduction in noise temperature compared to the previous generation and provide ECEI capability for absolute 2-D electron temperature profile measurements. Each LCP horn-waveguide module houses a 3x3 mm GaAs MMIC receiver chip, which consists of a low noise amplifier (LNA), balanced mixer, local oscillator multiplier chain driven by ~12 GHz input via an RF cable to the enclosure box, and IF amplifier. A proof-of-principle instrument with 5 poloidal channels was installed on DIII-D in 2017. The full proof-of-principle system installation (20 poloidal x 8 radial channels) was commissioned early in 2018. The LCP ECEI system is used for pedestal region measurements, especially focusing on temperature evolution during ELM bursting. The DIII-D ECE Imaging signal has been significantly improved with extremely effective shielding of out-of-band microwave noise which plagued previous ECE Imaging studies on DIII-D. In H-mode ELM bursting, the radial propagation of electron heat flow has been detected on DIII-D. The LCP ECE Imaging is expected to be a valuable diagnostic tool for ELM physics investigations.

Zhu, Y.↗