Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging and visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Real-time imaging of acoustic waves in bulk materials with X-ray microscopy

The dynamics of lattice vibrations govern many material processes, such as acoustic wave propagation, displacive phase transitions, and ballistic thermal transport. The maximum velocity of these processes and their effects is determined by the speed of sound, which therefore defines the temporal resolution (picoseconds) needed to resolve these phenomena on their characteristic length scales (nanometers). Here, we present an X-ray microscope capable of imaging acoustic waves with subpicosecond resolution within mm-sized crystals. We directly visualize the generation, propagation, branching, and energy dissipation of longitudinal and transverse acoustic waves in diamond, demonstrating how mechanical energy thermalizes from picosecond to microsecond timescales. Bulk characterization techniques capable of resolving this level of structural detail have previously been available on millisecond time scales—orders of magnitude too slow to capture these fundamental phenomena in solid-state physics and geoscience. As such, the reported results provide broad insights into the interaction of acoustic waves with the structure of materials, and the availability of ultrafast time-resolved dark-field X-ray microscopy opens a vista of new opportunities for 3D imaging of materials dynamics on their intrinsic submicrosecond time scales.

36 MATERIALS SCIENCE↗

Disentangling ferroelectric domain wall geometries and pathways in dynamic piezoresponse force microscopy via unsupervised machine learning

In this work, domain switching pathways in ferroelectric materials visualized by dynamic piezoresponse force microscopy (PFM) are explored via variational autoencoder, which simplifies the elements of the observed domain structure, crucially allowing for rotational invariance, thereby reducing the variability of local polarization distributions to a small number of latent variables. For small sampling window sizes the latent space is degenerate, and variability is observed only in the direction of a single latent variable that can be identified with the presence of domain wall. For larger window sizes, the latent space is 2D, and the disentangled latent variables can be generally interpreted as the degree of switching and complexity of domain structure. Applied to multiple consecutive PFM images acquired while monitoring domain switching, the polarization switching mechanism can thus be visualized in the latent space, providing insight into domain evolution mechanisms and their correlation with the microstructure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Coupling dynamic in situ X-ray micro-imaging and indentation: A novel approach to evaluate micromechanics applied to oil shale

Oil and gas shales are a system where understanding the mechanical properties at the microscale is of paramount importance, e.g. to better understand the behavior of proppant-shale contacts and their role in the evolution of propped fractures in unconventional reservoirs. Here we show for the first time an experiment coupling indentation testing with in situ X-ray imaging in a Green River shale sample. A full compliance curve has been measured with the sample in water, allowing to visualize the indentation of the sample in function of axial load, in a purpose-built system for combined in situ indentation and X-ray imaging. A series of 3D datasets were used for a digital volume correlation study to obtain local strain fields. This analysis has been complemented with the analysis of cracks. Finally, geomechanical modeling has been carried out to replicate and generalize the observed behavior in the shale. This study validated this experimental approach, providing a breakthrough in understanding micro-mechanics in shales, and demonstrates how this class of experiments can be important for studies involving the prediction of the evolution of propped fractures in shale reservoirs, with possible applications in a much larger number of application fields (geothermal, materials science, etc.)

04 OIL SHALES AND TAR SANDS↗

Machine-learning-enabled on-the-fly analysis of RHEED patterns during thin film deposition by molecular beam epitaxy

Thin film deposition is a fundamental technology for the discovery, optimization, and manufacturing of functional materials. Deposition by molecular beam epitaxy (MBE) typically employs reflection high-energy electron diffraction (RHEED) as a real-time in situ probe of the growing film. However, the state-of-the-art for RHEED analysis during deposition requires human observation. Here, we present an approach using machine learning (ML) methods to monitor, analyze, and interpret RHEED images on-the-fly during thin film deposition. In the analysis workflow, RHEED pattern images are collected at one frame per second and featurized using a pretrained deep convolutional neural network. The feature vectors are then statistically analyzed to identify changepoints; these changepoints can be related to changes in the deposition mode from initial film nucleation to a transition regime, smooth film deposition, and in some cases, an additional transition to a rough, islanded deposition regime. The feature vectors are additionally analyzed via graph analysis and community classification. The graph is quantified as a stabilization plot, and we show that inflection points in the stabilization plot correspond to changes in the growth regime. The full RHEED analysis workflow is termed RHAAPsody and includes data transfer and output to a visual dashboard. We demonstrate the functionality of RHAAPsody by analyzing the precaptured RHEED images from epitaxial depositions of anatase TiO2 on SrTiO3(001) and show that the analysis workflow can be executed in less than 1 s. Our approach shows promise as one component of ML-enabled real-time feedback control of the MBE deposition process.

36 MATERIALS SCIENCE↗

Unimodal Imaging of Monovalent Metal-Chelator Complexes and Lipids by MALDI Imaging Mass Spectrometry

Careful regulation of monovalent metal ions (M + ) is necessary to maintain a functional cellular system. Of these ions, appropriate sodium (Na + ) and potassium (K + ) concentrations are particularly integral for electrochemical signaling, as well as the secondary transport of nutrients and waste. Dysregulation of M + homeostasis can disrupt these mechanisms, potentially influencing the metabolism of downstream biomolecules such as lipids. Thus, the relationship between M + abundances and related biomolecular distributions must be elucidated to better understand the physiology of healthy and disordered tissues. Traditional techniques for imaging biological metal distributions include SIMS, LA-ICP-MS, and XRF; however, these capabilities are limited to elemental analysis or the analysis of molecular fragments and must be paired with other modalities to visualize distributions of more complex biomolecules within the same or similar samples. Conversely, matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) is a powerful tool often used for mapping such biomolecular distributions, but current methods are unable to detect metals within tissue. This study illustrates a novel methodology that adds metal detection to the MALDI IMS repertoire through which the simultaneous detection of M + metals and lipids is achievable. Using a robotic sprayer for homogeneous application, on-tissue deposition of the chelator deferiprone (DEF) enables subsequent detection of the ionizable metal-chelator complex by MALDI without hindering lipid detection. Our work provides proof-of-concept data for the simultaneous detection of K + , Na + , and intact lipids using MALDI IMS.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of time-dependent strain heterogeneity in shales using X-ray microscopy and digital volume correlation

In this paper, we report the results of a 4-dimensional (3 spatial dimensions plus time) in-situ creep experiment on a milli-core shale plug from Barnett formation in Texas. An outstanding challenge in shale mechanics is connecting observable characteristics to predictable mechanical and hydraulic behavior. We employ novel imaging and analysis techniques to statistically link sample mineralogy and structure to observed deformation. In particular, we focus on mechanisms of porosity reduction during transient response to step changes in stress, analogous to the aseismic deformation that occurs after an episode of fracturing. Our main goal in this study is to take the first steps to visualize and capture the small-scale deformation mechanisms involved in creep of shales, using imaging techniques. To do so, we conducted a uniaxial creep experiment inside an Xradia Versa 520 micro-CT system for 12 h at room temperature under a constant uniaxial stress of 25 MPa. We employed a Digital Volume Correlation (DVC) method to measure micro-scale deforspmation of the sample by comparing the resulting volumetric images with a high-resolution scan of the sample obtained prior to the creep experiment. The results indicate that the time-dependent deformation in the compliant clay plus kerogen matrix constituents facilitates rigid grain rotation and compaction of intergranular porosity at the boundary between rigid grains and matrix.

58 GEOSCIENCES↗

Optical coherence tomography imaging of plant root growth in soil

Complex interactions between roots and soil provide the nutrients and physical support required for robust plant growth. Yet, visualizing the root-soil interface is challenged by soil’s opaque scattering characteristics. In this paper, we describe methods for using optical coherence tomography (OCT) to provide non-destructive 3D and cross-sectional root imaging not available with traditional bright field microscopy. OCT is regularly used for bioimaging, especially in ophthalmology where it can detect retinal abnormalities. Prior use of OCT in plant biology has focused on surface defects of above ground tissues, predominantly in food crops. Our results show OCT is also viable for detailed, in situ study of living plant roots.

59 BASIC BIOLOGICAL SCIENCES↗

Spectroscopy imaging and analysis of live cells

Disclosed herein are systems, methods, systems and devices for measurement and visualization of chemical dynamics in living cells or tissues for diagnostic pathology. Devices can be open- or closed-channel microfluidic membrane devices for long-term IR spectroscopy of live adherent cells and ultimately for rapidly identifying time-dependent spectral features indicative of chemical abnormality in individual cells.

Holman, Hoi-Ying N.↗

Exploration of Electrochemical Reactions at Organic–Inorganic Halide Perovskite Interfaces via Machine Learning in In Situ Time-of-Flight Secondary Ion Mass Spectrometry

The instability of hybrid organic–inorganic perovskite (HOIP) devices is one of the significant challenges preventing commercialization. Exploring these phenomena is severely limited by the complexity of the intrinsic electrochemistry of HOIPs, the presence of multiple volatile and mobile ionic species, and the possible role of environmentally induced reactions at surfaces and triple-phase junctions. Here, in situ studies of the electrochemistry of methylammonium lead bromide perovskite with the Au electrode interface are reported via light- and voltage-dependent time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging of lateral perovskite heterostructures. While ToF-SIMS allows for the visualization of the chemical composition along the surface and its evolution with light and electrical bias, the interpretation of the multidimensional data obtained is often limited due to strong correlations between chemical signatures and the need to track multiple peaks at once. Here, a machine learning workflow combining the Hough transform and non-negative matrix factorization and no-negative tensor decomposition is developed to avoid this limitation and extract salient features of associated chemical changes and to separate the light- and voltage-dependent dynamics. Finally, combining these in situ characterizations and the machine learning workflow provides comprehensive information on the chemical nature of moving species, ion accumulation, and interfacial electrochemical reactions in HOIP devices.

36 MATERIALS SCIENCE↗

Crafting pixels in wood: understanding the interplay of technologies and visual perception in wooden photo engraving

This paper delves into the realm of laser engraving of photographs on wooden surfaces and explores the diferences between mathematical and human perception. A comprehensive quality study was conducted to explore the results achieved by 27 diferent realizations. The evaluation process involves both objective analyses and subjective assessments from hundreds of ratings of 60 evaluators, with the aim of unravelling the intricate interplay between technology and visual perception. The study also poses the intriguing question of whether the image most accurately transferred onto a wooden surface is also the most favourably perceived by potential customers and what are their preferences for laser engraved products.

Jurek, Martin [Ostrava, Tech. U.]↗

Nanoparticle Tracking to Probe Transport in Porous Media

From the granular and fractured subsurface environment to highly engineered polymer membranes used in pharmaceutical purification, porous materials are ubiquitous in nature and industrial applications. In particular, porous media are used extensively in processes including water treatment, pharmaceutical sterilization, food/beverage processing and heterogeneous catalysis, where hindered mass transport is either essential to the process or a necessary, but undesirable limitation. Unfortunately, there are currently no universal models capable of predicting mass transport based on a description of the porous material because real porous materials are complex, and because many coupled dynamic mechanisms (e.g. adsorption, steric effects, hydrodynamic effects, electrostatic interactions, etc.) give rise to the observed macroscopic transport phenomena. While classical techniques, like nuclear magnetic resonance and dynamic light scattering, provide useful information about mass transport in porous media at the ensemble level, they provide limited insight into the microscopic mechanisms that give rise to complex phenomena such as anomalous diffusion, hindered pore-space accessibility, and unexpected retention under flow, among many others. To address this issue, we have developed refractive index matching imaging systems, combined with single-particle tracking methods, allowing the direct visualization of single particle motion within a variety of porous materials. Here, we summarize our recent efforts to advance the understanding of nanoparticle transport in porous media using single-particle tracking methods in both fundamental and applied scenarios. First, we describe the basic principles for two-dimensional and three-dimensional single-particle tracking in porous materials. Then, we describe concrete examples of nanoparticle transport in porous materials from two perspectives: (1) understanding fundamental elementary particle transport processes in porous media, including pore accessibility and cavity escape, which limit transport in porous media; (2) facilitating applications in industrial processes, e.g. by understanding the mechanisms of particle fouling and remobilization in filtration membranes. Finally, we provide an outlook of opportunities associated with investigating other types of mass transport in confined environments using single-particle tracking methods, including electrophoretic and self-propelled motion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical Structure of the Plasma–Liquid Interface

Nonthermal atmospheric pressure plasma in contact with a liquid yields a variety of energetic photons, ions, and electrons, which can be transported into the plasma–liquid interface (PLI). Similar to the electrochemical interface formed between a solid electrode and electrolyte in conventional electrochemical systems, the charge-transfer process across the PLI is able to promote reduction–oxidation (redox) reactions. However, in the case of free plasma jets in contact with liquids, the absence of solid electrodes obscures the spatial locations of the electrochemical half-reactions. Herein, we present a spatial electrochemical measurement technique used to characterize an aqueous solution in contact with an atmospheric pressure plasma jet. The technique is based on measuring the potential difference between two identical Ag/AgCl electrochemical electrodes positioned at different locations within the solution. More specifically, electrochemical maps were made by measuring the potential of one electrochemical electrode positioned at different locations near the PLI with respect to the other electrochemical electrode positioned far away from the PLI in the bulk solution. Regions in the map with negative and positive potential differences between these electrochemical electrodes were used to identify the electrodeless cathode and anode, respectively. Here, visualization of the spatial distribution of molecular colorimetric redox indicators by multispectral imaging revealed that reduction was occurring near the plasma jet centerline while oxidation was occurring further away in solution, which constitutes an independent confirmation of the electrochemical maps.

Absorption↗

Stroboscopic x-ray diffraction microscopy of dynamic strain in diamond thin-film bulk acoustic resonators for quantum control of nitrogen-vacancy centers

Bulk-mode acoustic waves in a crystalline material exert lattice strain through the thickness of the sample, which couples to the spin Hamiltonian of defect-based qubits such as the nitrogen-vacancy (N-V) center defect in diamond. This mechanism has previously been harnessed for unconventional quantum spin control, spin decoherence protection, and quantum sensing. Bulk-mode acoustic wave devices are also important in the microelectronics industry as microwave filters. A key challenge in both applications is a lack of appropriate operando microscopy tools for quantifying and visualizing gigahertz-frequency dynamic strain. Here, in this work, we directly image acoustic strain within N-V center-coupled diamond thin-film bulk acoustic wave resonators using stroboscopic scanning hard x-ray diffraction microscopy at the Advanced Photon Source. The far-field scattering patterns of the nanofocused x-ray diffraction encode strain information entirely through the illuminated thickness of the resonator. These patterns have a real-space spatial variation that is consistent with the bulk strain’s expected modal distribution and a momentum-space angular variation from which the strain amplitude can be quantitatively deduced. We also perform optical measurements of strain-driven Rabi precession of of the N-V center spin ensemble, providing an additional quantitative measurement of the strain amplitude. As a result, we directly measure one of the six N-V spin-stress coupling parameters, 𝑏 =2.73⁢(2) MHz/GPa, by correlating these measurements at the same spatial position and applied microwave power. Our results demonstrate a unique technique for directly imaging ac lattice strain in micromechanical structures and provide a direct measurement of a fundamental constant for the N-V center defect spin Hamiltonian.

acoustic techniques↗

In situ characterization of foreign object damage (FOD) in environmental-barrier-coated silicon carbide (SiC) ceramic

Environmental barrier coatings (EBCs) protect advanced ceramics and ceramic matrix composites (CMCs) from oxidation and corrosion in gas turbine engine environments. Foreign object damage (FOD), where debris impact the protective coatings, is a critical hazard which limits the turbine durability. Despite previous efforts to understand FOD in EBCs, a detailed understanding of the fundamental transient damage mechanisms is still lacking. In the current work, the real-time FOD behavior of a Mullite / Silicon EBC was visualized via a dynamic synchrotron X-ray source in phase contrast imaging (PCI) configuration. Prior to the in situ FOD experiments, the microstructure and composition of the coating were respectively characterized using a scanning electron microscope (SEM) and X-ray diffraction (XRD). The variation in the properties of the debris was modeled by ~ 1.5 mm diameter Partially Stabilized Zirconia (PSZ) and Silicon Nitride (Si 3 N 4 ) spheres. A modified light-gas gun setup, synchronized with the X-ray beam, was used to propel the projectiles at velocities ranging between 300 and 355 m·s -1 . Coated samples were impacted under a fully backed support configuration and at normal incidence. Coating penetration and delamination, as well as projectile deformation at the bond coat resulted for FOD by PSZ spheres. Comparatively, projectile fracture, with subsequent rebound of fragments, as well as complete coating penetration and delamination at the substrate interface occurred for FOD by Si 3 N 4 spheres. It should be noted that only cone cracking was observed for FOD by PSZ spheres while back surface cracking was present for both projectile types. Qualitative understanding of the driving forces for the observed damage mechanisms were provided.

36 MATERIALS SCIENCE↗

Deep Learning for Intelligent Bubble Size Detection in the Spallation Neutron Source Visual Target

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) will undergo proton power upgrade (PPU), increasing the proton beam power from 1.4 MW to 2.8 MW. From 2.8 MW, 2.0 MW will go to the current First Target Station and the rest will go to the future Second Target Station (STS). The First Target Station uses a liquid mercury target that is contained in a 316L stainless steel vessel. The proton beam is pulsed at 60 Hz, with a pulse of about 0.7μs. When the proton beam hits the target, the intense energy deposition leads to a rapid rise in temperature in the mercury. This temperature rise creates pressure waves that propagate through the mercury and cause cavitation erosion. The power upgrade will cause stronger pressure waves that will further increase damage because of cavitation. Injecting small helium bubbles in the mercury has been an efficient method of mitigating the pressure wave at 1.4 MW. However, at higher power, additional mitigation is necessary. Therefore, the 2 MW target vessel will be equipped with swirl bubblers and an additional gas injection port near the nose to inject more gas in the target. To develop a gas injection strategy and design, flow visualization in water with a transparent prototypical target (“visual target”) was performed. Bubble sizes and their spatial distribution in the flow loop are crucial to understanding the effectiveness of the bubbles in mitigating pressure waves. Bubbles were generated in the visual target under varied conditions of input pressures with helium and air. Images were captured using a high-speed camera at varied frame rates at different positions away from the swirl bubbler and different depths in the flow loop under varying lighting conditions. Initially, methods such as circular Hough transforms were applied after a series of images processing to obtain a general distribution of bubble sizes. Bubbles smaller than 500 μm are preferred to effectively mitigate the effect of pressure waves, which demands an accurate bubble detection and sizing system. Intelligent detection and identification of bubble sizes alleviate misdetection and improves accuracies. Employing neural networks, intelligent detection of bubble sizes and their distribution was developed and provides a robust alternative to traditional techniques. Human intervention was employed to label in-focus and out-of-focus bubbles in the set of training images. An object detection network using a pretrained convolutional neural network was created that extracted the features from the training images. Data augmentation was used to improve network accuracy through a random transformation of the original data.

Rasheed, Fayaz↗

Evaluating Image Classification Deep Convolutional Neural Network Architectures for Remaining Useful Life Estimation of Turbofan Engines

Accurate estimation of the remaining useful life (RUL) is a key component of condition-based maintenance (CBM) and prognosis and health management (PHM). Data-based models for the estimation of RUL are of particular interest because expert knowledge of systems is not always available, and physical modeling is often not feasible. Additionally, using data-based models, which make decisions based on raw sensor data, allow features to be learned instead of manually determined. In this work, deep convolutional neural network (CNN) architectures are investigated for their ability to estimate the RUL of turbofan engines. To improve the accuracy of the models, CNN architectures, which have proven successful in image classification, are implemented and tested. Specifically, the blocks used in the Visual Geometry Group (VGG) architecture, inception modules used in the GoogLeNet architecture, and residual blocks used in the ResNet architecture are incorporated. To account for varying flight lengths, the input to the models is a window of time series data collected from the engine under test. Window locations at the climb, cruise, and descent stages are considered. To further improve the RUL estimations, multiple overlapping windows at each location are used. This increases the amount of training data available and is found to increase the accuracy of the resulting RUL estimations by averaging the estimates from all overlapping segments. The model is trained and tested using the new Commercial Modular Aero-Propulsion System Simulation (N-CMAPSS) data set, and high prognosis accuracy was achieved. Furthermore, this work expands on the model developed and used in the 2021 PHM Society Data Challenge, which received second place.

convolutional neural networks↗

An Extensive Catalog of Early-type Dwarf Galaxies in the Local Universe: Morphology and Environment

We present an extensive catalog of 5405 early-type dwarf (dE) galaxies located in the various environments, i.e., clusters, groups, and fields, of the local universe (z < 0.01). The dEs are selected through visual inspection of the Legacy survey's g–r–z combined tricolor images. The inspected area, covering a total sky area of 7643 deg 2 , encompasses two local clusters (Virgo and Fornax), 265 groups, and the regions around 586 field galaxies of M K < -21 mag. The catalog aims to be one of the most extensive and publicly accessible collections of data on dEs, despite its complex completeness limits, which may not accurately represent its statistical completeness. The strength of the catalog lies in the morphological characteristics, including nucleated, tidal, and ultradiffuse dEs. The two clusters contribute nearly half (2437 out of 5405) of the dEs, and the 265 groups contribute 2103 dEs. There are 864 dEs in 586 fields, i.e., ~1.47 dEs per field. Using a standard definition commonly used in literature, we identify 100 ultradiffuse galaxies (UDGs), which compose ~2% of the dE population. We find that 40% of our sample dEs harbor a central nucleus, and among the UDG population, a majority (79%) are nonnucleated. About 1.3% of dEs suffer from ongoing tidal disturbance by nearby massive galaxies, and only 0.03% show a sign of recent dwarf–dwarf mergers. The association between dEs and their nearest bright neighbor galaxies suggests that dEs are more likely created where their neighbors are non-star-forming ones.

79 ASTRONOMY AND ASTROPHYSICS↗

Shallow cumuli cover and its uncertainties from ground-based lidar–radar data and sky images

Cloud cover estimates of single-layer shallow cumuli obtained from narrow field-of-view (FOV) lidar–radar and wide-FOV total sky imager (TSI) data are compared over an extended period (2000–2017 summers) at the established United States Atmospheric Radiation Measurement mid-continental Southern Great Plains site. We quantify the impacts of two factors on hourly and sub-hourly cloud cover estimates: (1) instrument-dependent cloud detection and data merging criteria and (2) FOV configuration. Enhanced observations at this site combine the advantages of the ceilometer, micropulse lidar (MPL) and cloud radar in merged data products. Data collected by these three instruments are used to calculate narrow-FOV cloud fraction (CF) as a temporal fraction of cloudy returns within a given period. Sky images provided by TSI are used to calculate the wide-FOV fractional sky cover (FSC) as a fraction of cloudy pixels within a given image. To assess the impact of the first factor on CF obtained from the merged data products, we consider two additional subperiods (2000–2010 and 2011–2017 summers) that mark significant instrumentation and algorithmic advances in the cloud detection and data merging. We demonstrate that CF obtained from ceilometer data alone and FSC obtained from sky images provide the most similar and consistent cloud cover estimates; hourly bias and root-mean-square difference (RMSD) are within 0.04 and 0.12, respectively. However, CF from merged MPL–ceilometer data provides the largest estimates of the multiyear mean cloud cover, about 0.12 (35 %) and 0.08 (24 %) greater than FSC for the first and second subperiods, respectively. CF from merged ceilometer–MPL–radar data has the strongest subperiod dependence with a bias of 0.08 (24 %) compared to FSC for the first subperiod and shows no bias for the second subperiod. The strong period dependence of CF obtained from the combined ceilometer–MPL–radar data is likely results from a change in what sensors are relied on to detect clouds below 3 km. After 2011, the MPL stopped being used for cloud top height detection below 3 km, leaving the radar as the only sensor used in cloud top height retrievals. To quantify the FOV impact, a narrow-FOV FSC is derived from the TSI images. We demonstrate that FOV configuration does not modify the bias but impacts the RMSD (0.1 hourly, 0.15 sub-hourly). In particular, the FOV impact is significant for sub-hourly observations, where 41 % of narrow- and wide-FOV FSC differ by more than 0.1. A new “quick-look” tool is introduced to visualize impacts of these two factors through integration of CF and FSC data with novel TSI-based images of the spatial variability in cloud cover. The influence of cloud field organization, such cloud streets parallel to the wind direction, on narrow- and wide-FOV cloud cover estimates can be visually assessed.

54 ENVIRONMENTAL SCIENCES↗