Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

(S)TEM/EDS study of native precipitates and irradiation induced Nb-rich platelets in high-burnup M5®

We have investigated microstructure and microchemistry of precipitates and dislocation loops in high-burnup M5® using (scanning) transmission electron microscopy ((S)TEM) equipped with energy dispersive X-ray spectroscopy (EDS). Two (S)TEM lamellae were made by cryo-FIB from the same cladding sample. The Nb-rich native precipitates were found in the metal, in the suboxide and in the oxide. Upon diffraction analysis, most of the Nb-rich native precipitates in the metal matrix remain as β-Nb phase, while no β-Nb native precipitates were found in the oxide. Nearby the oxide and metal (O/M) interface, the native precipitates in the oxide were already oxidized into t-NbO2 phase. At further distance away from the O/M interface, the Nb-rich native precipitates were gradually oxidized and became amorphous. Besides the native precipitates, Nb-rich irradiation induced precipitates (IIPs) were found in the metal matrix. Using g = <0002> vector for imaging, the length of the IIPs was aligned with dislocation loops. However, no Nb segregation to the dislocation loops themselves was observed. For the first time, we report that IIPs indeed exist in the oxide but only within about 1.5 µm away from O/M interface. However, the oxidation state of the IIPs in the oxide is still unclear. The presence of both native precipitates and IIPs in the oxide may indicate the Nb concentration in the oxide solid solution remain low nearby the O/M interface, which may explain the reduced corrosion kinetics of in-pile M5®. On the other hand, no IIPs were observed in the oxide at further distance and this may indicate that they have eventually dissolved back into the oxide. A few mechanisms related to IIPs stability in the oxide are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of a 3D Diode Array Dosimeter for Helical Tomotherapy Delivery QA

The Delta4 biplanar diode array dosimeter was validated for helical tomotherapy delivery QA. The basic detector characteristics were found to be satisfactory in terms of short-term reproducibility (0.1%), linearity (<0.1%), dose rate dependence (0.4%), and absolute calibration accuracy (0.4% in the center of the phantom compared with the independently calibrated diode). Relative calibration of the arrays was verified by comparison with film and by rotating the detector 180{sup o}. The dosimeter response to rotational irradiation changed by no more than 0.2% when one of the detector boards was replaced by the homogeneous phantom material. The daily output correction factor can be derived from a Delta4 measurement in a uniform cylindrical field. The {gamma}(3%, 3 mm) passing rate (absolute dose) was above 90% for all 9 evaluated clinical plans, and above 96% for all but one. The mean passing rate was 97 {+-} 2.7%. The plans varied in modulation factor, pitch, and calculation grid size. For best results, the phantom needs to be aligned carefully, preferably by megavoltage computed tomography imaging.

07 ISOTOPE AND RADIATION SOURCES↗

Collimation of laser-produced plasmas using axial magnetic field

We investigated the expansion dynamics of laser-produced plasmas expanding into an axial magnetic field. Plasmas were generated by focusing 1.064 µm Nd:YAG laser pulses onto a planar tin target in vacuum and allowed to expand into a 0.5 T magnetic-filed where field lines were aligned along the plume expansion direction. Gated images employing intensified CCD showed focusing of the plasma plume, which were also compared with results obtained using particle-in-cell modelling methods. The estimated density and temperature of the plasma plumes employing emission spectroscopy revealed significant changes in the presence and absence of the 0.5T magnetic field. In the presence of the field, the electron temperature is increased with distance from the target, while the density showed opposite effects.

laser produced plasma↗

Anisotropic impurity states, quasiparticle scattering and nematic transport in underdoped Ca(Fe1-xCo x )2As2

Iron-based high-temperature superconductivity develops when the ‘parent’ antiferromagnetic/orthorhombic phase is suppressed, typically by introduction of dopant atoms1. But their impact on atomic-scale electronic structure, although in theory rather complex2,3,4,5,6,7,8,9,10,11,12,13, is unknown experimentally. What is known is that a strong transport anisotropy14,15,16,17,18,19,20,21,22,23,24,25 with its resistivity maximum along the crystal b axis14,15,16,17,18,19,20,21,22,23,24,25, develops with increasing concentration of dopant atoms14,20,21,22,23,24,25; this ‘nematicity’vanishes when the parent phase disappears near the maximum superconducting Tc. The interplay between the electronic structure surrounding each dopant atom, quasiparticle scattering therefrom and the transport nematicity has therefore become a pivotal focus7,8,12,22,23 of research into these materials. Here, by directly visualizing the atomic-scale electronic structure, we show that substituting Co for Fe atoms in underdoped Ca(Fe1-xCox)2As2 generates a dense population of identical anisotropic impurity states. Each is ~ 8 Fe–Fe unit cells in length, and all are distributed randomly but aligned with the antiferromagnetic a axis. By imaging their surrounding interference patterns, we further demonstrate that these impurity states scatter quasiparticles in a highly anisotropic manner, with the maximum scattering rate concentrated along the b axis. These data provide direct support for the recent proposals7,8,12,22,23 that it is primarily anisotropic scattering by dopant-induced impurity states that generates the transport nematicity; they also yield simple explanations for the enhancement of the nematicity proportional to the dopant density14,20,21,22,23,24,25 and for the occurrence of the highest resistivity along the b axis14,15,16,17,18,19,20,21,22,23,24,25.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CHANDRA AND HUBBLE SPACE TELESCOPE OBSERVATIONS OF THE SUPERSOFT ULX IN NGC 247: CANDIDATE FOR STANDARD DISK EMISSION

We report on multiwavelength observations of the supersoft ultraluminous X-ray source (ULX) in NGC 247 made with the Chandra X-Ray Observatory and Hubble Space Telescope. We aligned the X-ray and optical images using three objects present on both and identified a unique, point-like optical counterpart to the ULX. The X-ray to optical spectrum is well fitted with an irradiated disk model if the extinction measured for Cepheids in NGC 247 is used. Assuming only Galactic extinction, the spectrum can be modeled as a standard thin accretion disk. Either result leads to the conclusion that a disk interpretation of the X-ray spectrum is valid, thus the source may be in the X-ray thermal state and contain an intermediate-mass black hole of at least 600 M {sub Sun }. In contrast to other supersoft ULXs that are transient and exhibit a luminosity temperature relation inconsistent with a disk interpretation of the X-ray emission, the NGC 247 ULX has a relatively steady flux and all available X-ray data are consistent with emission from a disk in the thermal state.

79 ASTRONOMY AND ASTROPHYSICS↗

DOPPLER SHIFTS IN ACTIVE REGION MOSS USING SOHO/SUMER

The velocity of the plasma at the footpoint of hot loops in active region cores can be used to discriminate between different heating frequencies. Velocities on the order of a few kilometers per second would indicate low-frequency heating on sub-resolution strands, while velocities close to zero would indicate high-frequency (steady) heating. To discriminate between these two values requires accurate velocity measurements; previous velocity measurements suffer from large uncertainties, mainly due to the lack of an absolute wavelength reference scale. In this paper, we determine the velocity in the loop footpoints using observations from Solar Ultraviolet Measurements of Emitted Radiation (SUMER) on Solar and Heliospheric Observatory. We use neutral spectral lines to determine the wavelength scale of the observations with an uncertainty in the absolute velocity of <3.5 km s{sup -1} and co-aligned Transition Region and Coronal Explorer (TRACE) images to identify footpoint regions. We studied three different active regions and found average redshifts in the Ne VIII 770 A emission line (formed at 6 Multiplication-Sign 10{sup 5} K) of 5.17 {+-} 5.37 km s{sup -1} and average redshifts in the C IV 1548 and 1550 A emission lines (formed at 1 Multiplication-Sign 10{sup 5} K) of 13.94 {+-} 4.93 km s{sup -1} and 14.91 {+-} 6.09 km s{sup -1}, respectively. We find no correlation between the brightness in the spectral line and the measured velocity, nor do we find correlation between the Ne VIII and C IV velocities measured co-spatially and co-temporally. SUMER scanned two of the active regions twice; in those active regions we find positive correlation between the co-spatial velocities measured during the first and second scans. These results provide definitive and quantitative measurements for comparisons with simulations of different coronal heating mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

VLBI FOR GRAVITY PROBE B. VII. THE EVOLUTION OF THE RADIO STRUCTURE OF IM PEGASI

We present measurements of the total radio flux density as well as very long baseline interferometry images of the star, IM Pegasi, which was used as the guide star for the NASA/Stanford relativity mission Gravity Probe B. We obtained flux densities and images from 35 sessions of observations at 8.4 GHz ({lambda} = 3.6 cm) between 1997 January and 2005 July. The observations were accurately phase-referenced to several extragalactic reference sources, and we present the images in a star-centered frame, aligned by the position of the star as derived from our fits to its orbital motion, parallax, and proper motion. Both the flux density and the morphology of IM Peg are variable. For most sessions, the emission region has a single-peaked structure, but 25% of the time, we observed a two-peaked (and on one occasion perhaps a three-peaked) structure. On average, the emission region is elongated by 1.4 {+-} 0.4 mas (FWHM), with the average direction of elongation being close to that of the sky projection of the orbit normal. The average length of the emission region is approximately equal to the diameter of the primary star. No significant correlation with the orbital phase is found for either the flux density or the direction of elongation, and no preference for any particular longitude on the star is shown by the emission region.

79 ASTRONOMY AND ASTROPHYSICS↗

Auto calibration of a cone-beam-CT

Purpose: This paper introduces a novel autocalibration method for cone-beam-CTs (CBCT) or flat-panel CTs, assuming a perfect rotation. The method is based on ellipse-fitting. Autocalibration refers to accurate recovery of the geometric alignment of a CBCT device from projection images alone, without any manual measurements. Methods: The authors use test objects containing small arbitrarily positioned radio-opaque markers. No information regarding the relative positions of the markers is used. In practice, the authors use three to eight metal ball bearings (diameter of 1 mm), e.g., positioned roughly in a vertical line such that their projection image curves on the detector preferably form large ellipses over the circular orbit. From this ellipse-to-curve mapping and also from its inversion the authors derive an explicit formula. Nonlinear optimization based on this mapping enables them to determine the six relevant parameters of the system up to the device rotation angle, which is sufficient to define the geometry of a CBCT-machine assuming a perfect rotational movement. These parameters also include out-of-plane rotations. The authors evaluate their method by simulation based on data used in two similar approaches [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004); K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)]. This allows a direct comparison of accuracy. Furthermore, the authors present real-world 3D reconstructions of a dry human spine segment and an electronic device. The reconstructions were computed from projections taken with a commercial dental CBCT device having two different focus-to-detector distances that were both calibrated with their method. The authors compare their reconstruction with a reconstruction computed by the manufacturer of the CBCT device to demonstrate the achievable spatial resolution of their calibration procedure. Results: Compared to the results published in the most closely related work [K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)], the simulation proved the greater accuracy of their method, as well as a lower standard deviation of roughly 1 order of magnitude. When compared to another similar approach [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004)], their results were roughly of the same order of accuracy. Their analysis revealed that the method is capable of sufficiently calibrating out-of-plane angles in cases of larger cone angles when neglecting these angles negatively affects the reconstruction. Fine details in the 3D reconstruction of the spine segment and an electronic device indicate a high geometric calibration accuracy and the capability to produce state-of-the-art reconstructions. Conclusions: The method introduced here makes no requirements on the accuracy of the test object. In contrast to many previous autocalibration methods their approach also includes out-of-plane rotations of the detector. Although assuming a perfect rotation, the method seems to be sufficiently accurate for a commercial CBCT scanner. For devices which require higher dimensional geometry models, the method could be used as a initial calibration procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SINGLE: Atomic-resolution structure identification of nanocrystals by graphene liquid cell EM

Analysis of the three-dimensional (3D) structures of nanocrystals with solution-phase transmission electron microscopy is beginning to reveal their unique physiochemical properties. We developed a “one-particle Brownian 3D reconstruction method” based on imaging of ensembles of colloidal nanocrystals using graphene liquid cell electron microscopy. Projection images of differently rotated nanocrystals are acquired using a direct electron detector with high temporal (<2.5 ms) resolution and analyzed to obtain an ensemble of 3D reconstructions. Here, we introduce computational methods required for successful atomic-resolution 3D reconstruction: (i) tracking of the individual particles throughout the time series, (ii) subtraction of the interfering background of the graphene liquid cell, (iii) identification and rejection of low-quality images, and (iv) tailored strategies for 2D/3D alignment and averaging that differ from those used in biological cryo–electron microscopy. Our developments are made available through the open-source software package SINGLE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ALS/Milo: BL402 RSXD data analysis

Suite of tools designed to simply data collection, extraction, reduction, and plotting for resonant soft x-ray scattering experiments performed at ALS beamline 4.0.2; speeds up the process of converting data into meaningful information for users to publish experimental results. * Python software routines for processing CCD images, including reciprocal space maps, diffraction peak alignment, resonant spectral profiles, line-cut comparisons, coordinate transforms, etc. * Scan file generator, optimized for typical uses cases, reduces burden on users by handling complex operations behind the scenes of a simplified user interface * Deployed at beamline endstation computers; packaged and deployable as standardized PyPI package * Under version control (git) and hosted on LBL-sponsored repository (bitbucket)

Shafer, Padraic↗

Development and Applications of a Two-dimensional Tip-Tilting Stage System with Nanoradian-Level Positioning Resolution

In this paper, designs of a novel rotary weak-link stage for a vertical rotation axis and a two-dimensional tip-tilting system are presented. Applications of these new stage systems include: an advanced X-ray stereo imaging instrument for particle tracking velocimetry, an alignment stage system for hard X-ray nano-focusing Montel mirror optics, and an ultra-precision crystal manipulator for cryo-cooling optical cavities of an X-ray free-electron-laser oscillator (XFELO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Properties of YBCO on LaMnO3-capped IBAD MgO-templates without Homo-epitaxial MgO layer.

Previously, it has been well established that in an IBAD architecture for coated conductors, (1) LaMnO3 (LMO) buffer layers are structurally and chemically compatible with an underlying homo-epitaxial MgO layer and (2) high current density YBCO films can be grown on these LMO templates. In the present work, the homo-epi MgO layer has been successfully eliminated and a LMO cap layer was grown directly on the IBAD (MgO) template. The performance of the LMO/IBAD (MgO) samples has been qualified by depositing 1 m-thick YBCO coatings by pulsed laser deposition. Electrical transport measurements of YBCO films on the standard (with homo-epi MgO) and simplified (without homo-epi MgO) IBAD architectures were carried out. The angular dependencies of critical current density (Jc) are similar for both IBAD architectures. XRD measurements indicate good, c-axis aligned YBCO films. Transmission electron microscopy (TEM) images reveal that microstructures of YBCO/LMO/IBAD (MgO) and YBCO/LMO/homo-epi MgO/IBAD (MgO) templates are similar. These results demonstrate the strong potential of using LMO as a single cap layer directly on IBAD (MgO) for the development of a simplified IBAD architecture.

36 MATERIALS SCIENCE↗

SU-E-J-119: What Effect Have the Volume Defined in the Alignment Clipbox for Cervical Cancer Using Automatic Registration Methods for Cone- Beam CT Verification?

Purpose: To investigate the impact of different clipbox volumes with automated registration techniques using commercially available software with on board volumetric imaging(OBI) for treatment verification in cervical cancer patients. Methods: Fifty cervical cancer patients received daily CBCT scans(on-board imaging v1.5 system, Varian Medical Systems) during the first treatment week and weekly thereafter were included this analysis. A total of 450 CBCT scans were registered to the planning CTscan using pelvic clipbox(clipbox-Pelvic) and around PTV clip box(clipbox- PTV). The translations(anterior-posterior, left-right, superior-inferior) and the rotations(yaw, pitch and roll) errors for each matches were recorded. The setup errors and the systematic and random errors for both of the clip-boxes were calculated. Paired Samples t test was used to analysis the differences between clipbox-Pelvic and clipbox-PTV. Results: . The SD of systematic error(σ) was 1.0mm, 2.0mm,3.2mm and 1.9mm,2.3mm, 3.0mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. The average random error(Σ)was 1.7mm, 2.0mm,4.2mm and 1.7mm,3.4mm, 4.4mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. But, only the SI direction was acquired significantly differences between two image registration volumes(p=0.002,p=0.01 for mean and SD). For rotations, the yaw mean/SD and the pitch SD were acquired significantly differences between clipbox-Pelvic and clipbox-PTV. Conclusion: The defined volume for Image registration is important for cervical cancer when 3D/3D match was used. The alignment clipbox can effect the setup errors obtained. Further analysis is need to determine the optimal defined volume to use the image registration in cervical cancer. Conflict of interest: none.

60 APPLIED LIFE SCIENCES↗

Development of an x-ray prism for analyzer based imaging systems

Analyzer crystal based imaging techniques such as diffraction enhanced imaging (DEI) and multiple imaging radiography (MIR) utilize the Bragg peak of perfect crystal diffraction to convert angular changes into intensity changes. These x-ray techniques extend the capability of conventional radiography, which derives image contrast from absorption, by providing large intensity changes for small angle changes introduced from the x-ray beam traversing the sample. Objects that have very little absorption contrast may have considerable refraction and ultrasmall angle x-ray scattering contrast improving visualization and extending the utility of x-ray imaging. To improve on the current DEI technique an x-ray prism (XRP) was designed and included in the imaging system. The XRP allows the analyzer crystal to be aligned anywhere on the rocking curve without physically moving the analyzer from the Bragg angle. By using the XRP to set the rocking curve alignment rather than moving the analyzer crystal physically the needed angle sensitivity is changed from submicroradians for direct mechanical movement of the analyzer crystal to tens of milliradians for movement of the XRP angle. However, this improvement in angle positioning comes at the cost of absorption loss in the XRP and depends on the x-ray energy. In addition to using an XRP for crystal alignment it has the potential for scanning quickly through the entire rocking curve. This has the benefit of collecting all the required data for image reconstruction in a single measurement thereby removing some problems with motion artifacts which remain a concern in current DEI/MIR systems especially for living animals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPECKLE CAMERA OBSERVATIONS FOR THE NASA KEPLER MISSION FOLLOW-UP PROGRAM

We present the first results from a speckle imaging survey of stars classified as candidate exoplanet host stars discovered by the Kepler mission. We use speckle imaging to search for faint companions or closely aligned background stars that could contribute flux to the Kepler light curves of their brighter neighbors. Background stars are expected to contribute significantly to the pool of false positive candidate transiting exoplanets discovered by the Kepler mission, especially in the case that the faint neighbors are eclipsing binary stars. Here, we describe our Kepler follow-up observing program, the speckle imaging camera used, our data reduction, and astrometric and photometric performance. Kepler stars range from R = 8 to 16 and our observations attempt to provide background non-detection limits 5-6 mag fainter and binary separations of {approx}0.05-2.0 arcsec. We present data describing the relative brightness, separation, and position angles for secondary sources, as well as relative plate limits for non-detection of faint nearby stars around each of 156 target stars. Faint neighbors were found near 10 of the stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a one-stop beam verification system using electronic portal imaging devices for routine quality assurance

In this study, a computer-based system for routine quality assurance (QA) of a linear accelerator (linac) was developed by using the dosimetric properties of an amorphous silicon electronic portal imaging device (EPID). An acrylic template phantom was designed such that it could be placed on the EPID and be aligned with the light field of the collimator. After irradiation, portal images obtained from the EPID were transferred in DICOM format to a computer and analyzed using a program we developed. The symmetry, flatness, field size, and congruence of the light and radiation fields of the photon beams from the linac were verified simultaneously. To validate the QA system, the ion chamber and film (X-Omat V2; Kodak, New York, NY) measurements were compared with the EPID measurements obtained in this study. The EPID measurements agreed with the film measurements. Parameters for beams with energies of 6 MV and 15 MV were obtained daily for 1 month using this system. It was found that our QA tool using EPID could substitute for the film test, which is a time-consuming method for routine QA assessment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Smart quantum statistical imaging beyond the Abbe-Rayleigh criterion

The wave nature of light imposes limits on the resolution of optical imaging systems. For over a century, the Abbe-Rayleigh criterion has been utilized to assess the spatial resolution limits of imaging instruments. Recently, there has been interest in using spatial projective measurements to enhance the resolution of imaging systems. Unfortunately, these schemes require a priori information regarding the coherence properties of “unknown” light beams and impose stringent alignment conditions. Here, we introduce a smart quantum camera for superresolving imaging that exploits the self-learning features of artificial intelligence to identify the statistical fluctuations of unknown mixtures of light sources at each pixel. This is achieved through a universal quantum model that enables the design of artificial neural networks for the identification of photon fluctuations. Our protocol overcomes limitations of existing superresolution schemes based on spatial mode projections, and consequently provides alternative methods for microscopy, remote sensing, and astronomy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

AstroCLIP: a cross-modal foundation model for galaxies

ABSTRACT We present AstroCLIP, a single, versatile model that can embed both galaxy images and spectra into a shared, physically meaningful latent space. These embeddings can then be used – without any model fine-tuning – for a variety of downstream tasks including (1) accurate in-modality and cross-modality semantic similarity search, (2) photometric redshift estimation, (3) galaxy property estimation from both images and spectra, and (4) morphology classification. Our approach to implementing AstroCLIP consists of two parts. First, we embed galaxy images and spectra separately by pre-training separate transformer-based image and spectrum encoders in self-supervised settings. We then align the encoders using a contrastive loss. We apply our method to spectra from the Dark Energy Spectroscopic Instrument and images from its corresponding Legacy Imaging Survey. Overall, we find remarkable performance on all downstream tasks, even relative to supervised baselines. For example, for a task like photometric redshift prediction, we find similar performance to a specifically trained ResNet18, and for additional tasks like physical property estimation (stellar mass, age, metallicity, and specific-star-formation rate), we beat this supervised baseline by 19 per cent in terms of R2. We also compare our results with a state-of-the-art self-supervised single-modal model for galaxy images, and find that our approach outperforms this benchmark by roughly a factor of two on photometric redshift estimation and physical property prediction in terms of R2, while remaining roughly in-line in terms of morphology classification. Ultimately, our approach represents the first cross-modal self-supervised model for galaxies, and the first self-supervised transformer-based architectures for galaxy images and spectra.

Parker, Liam (ORCID:0009000749521674)↗