Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “homes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A New Look For Greenbelt

Greenbelt, Maryland, 12 miles from the nation's capital, is an efficiently planned model town and most of its 1600 homes are almost identical in appearance. Four of them, however, stand out from their neighbors; they have distinctive blue glass rooftop superstructures made up of a series of solar collectors. They are part of a NASA community aid program, a joint energy research project involving the Greenbelt housing cooperative and NASA's Goddard Space Flight Center, located near the community. Built in 1935, Greenbelt is one of three government-planned communities of President Franklin D. Roosevelt's first administration; the others are Greendale, Wisconsin and Greenhills, Ohio. The government built the towns to make available low-cost housing, provide employment for workers on relief in the Great Depression era, and to establish models designed to encourage construction of similar developments by private industry. In 1952, the residents of Greenbelt formed a nonprofit cooperative called Greenbelt Homes, Inc., which bought the dwellings, facilities and a large part of the land from the government. The homes are individually owned but collectively maintained by the co-op, with each owner paying a prorated share of utility and maintenance costs. Greenbelt residents are mostly in the low and medium income brackets, and one of every three families lives on a fixed retirement income. For that reason, the sharp escalation of fuel oil prices that began in 1973 imposed particular hardship on the co-op community. So Greenbelt Homes' management asked its NASA neighbor, Goddard Space Flight Center, for assistance in setting up a solar energy research project. The idea was to conduct a small scale demonstration to show what savings could be realized by solar heating Greenbelt homes, with an eye toward possible future expansion of solar energy systems as a means of combating rising fuel costs. Goddard undertook the project as part of the federal government's effort to research and demonstrate ways of conserving energy. The Center was well qualified for the assignment, having acquired extensive expertise in designing thermal control systems for satellites, which must maintain stable temperatures for successful operation.

Source record↗

Tech House

The members of the Swain family- Dr. Charles "Bill" Swain, wife Elaine, daughter Carol, 17, son "Chuck", 12, and dog Susie have an interesting assignment. They are active participants in an important NASA research program involving the application of space-age technology to home construction. b' Transplanted Floridians, the Swains now reside in NASA's Tech House, lo~atedat Langley Research Center, Hampton, Virginia. Their job is to use and help evaluate the variety of advanced technology systems in Tech House. A contemporary three-bedroom home, Tech House incorporates NASA technology, the latest commercial building techniques and other innovations, all designed to reduce energy and water consumption and to provide new levels of comfort, convenience, security and fire safety. Tech House equipment performed well in initial tests, but a house is not a home until it has people. That's where the Swains come in. NASA wants to see how the various systems work under actual living conditions, to confirm the effectiveness of the innovations or to determine necessary modifications for improvement. The Swains are occupying the house for a year, during which NASA engineers are computer monitoring the equipment and assembling a record of day-to-day performance. . Tech House is a laboratory rather than a mass production prototype, but its many benefits may influence home design and construction. In a period of sharply rising utility costs, widespread adoption of Tech House features could provide large-scale savings to homeowners and potentially enormous national benefit in resources conservation. Most innovations are aerospace spinoffs: Some of the equipment is now commercially available; other systems are expected to be in production within a few years. Around 1980, a Tech House-type of home could be built for $45-50,000 (1 976 dollars). It is estimated that the homeowner would save well over $20,000 (again 1976 dollars) in utility costs over the average mortgage span of 20 years.

Source record↗

Metrics and Analytical Frameworks for Valuing Energy Efficiency and Distributed Energy Resources in the Built Environment: Preprint

This paper summarizes efforts to develop new—and enhance existing—analytical frameworks and metrics to quantify the value that grid-interactive efficient homes with solar (GEB-solar homes) can provide. Industry is working to characterize and understand these capabilities and benefits, but existing analytical frameworks for evaluating energy efficiency (EE) are often siloed from those that evaluate distributed energy resources (DERs). Five metrics were adapted from an extensive literature review and applied to case studies of a modeled home in Riverside, California: ramp up/down, cover factor demand/supply, and curtailable load. Eight different technology scenarios were analyzed using a more tightly connected suite of building-to-grid models (BEopt, REopt, ReEDS, and PLEXOS). Additionally, an initial version of the Cambium tool was developed, characterizing the marginal prices and emissions from NREL’s 2018 Standard Scenarios. These grid costs were extended to a time-varying proxy retail rate and applied as part of a new grid alignment metric. In the results, a more integrated combination of GEB-solar technologies led to a higher cover factor demand—the percentage of gross home load covered by on-site solar—however, a benchmark was required to determine what range of cover factor was “best” for given grid conditions. To that end, a grid alignment cost metric was applied to the case study scenarios. The average cost to serve the net load of the home decreased from a median of ~$0.24/kWh to ~$0.10/kWh when the most integrated technology scenario was optimized towards the grid pricing proxy versus the time-of-use (TOU) rate.

41 EE - Solar Energy Technologies Office (EE-4S)↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

In cooperation with the Building America Program, The Levy Partnership explored a variety of options to reduce space-conditioning energy consumption, working with partners to design, manu- facture, and build test homes in three states. The Levy Partnership tested the use of minisplit ductless heat pumps in combi- nation with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The team set out to achieve 50% less energy consumption, compared to the 2009 International Energy Conservation Code, while maintaining home afford- ability and thermal comfort. The strategy also included a highly efficient thermal envelope to reduce space-conditioning loads.

30 DIRECT ENERGY CONVERSION↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

This project explored the use of minisplit ductless heat pumps in combination with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The objectives were to reduce space-conditioning energy consumption by 50% compared to the 2009 International Energy Conservation Code (ICC 2009) while maintaining home affordability and thermal comfort. The strategy to achieve this goal also included a highly efficient thermal envelope to reduce space-conditioning loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Energy Justice in Alaska

NREL works with remote and rural communities across Alaska and the world to develop energy and building technologies that enhance culture, strengthen economies, and improve resilience in a changing environment. Alaska and Arctic communities not only face one of the harshest climates on earth; they also pay some of the highest energy and housing costs in the nation. NREL's Alaska Campus collaborates with communities and tribes to develop affordable, culturally appropriate homes and buildings that combine traditional knowledge and twenty-first century technology. Demonstration homes deployed all over Alaska prove out new technologies in energy efficiency, foundations, indoor air quality, and clean energy. Local workforce development is incorporated into every project: new homes are built by local workers, often including the home's future occupant. With the Arctic warming twice as fast as the rest of the planet, coastal erosion and thawing permafrost are wreaking havoc on roads, buildings, and infrastructure across Alaska. With an inclusive approach to R&D, NREL is helping communities adapt to a changing environment and advancing energy justice in the world's extremes.

Alaska housing prototypes↗

Uplifting winds: The surprisingly positive community-wide impact of wind energy installations on property values

A primary concern of stakeholders when considering a new wind project is the potential negative effects wind turbines may have on home values. Yet, what has been surprisingly overlooked in the literature and general discourse around wind energy is that the well-researched positive economic development and fiscal and amenity benefits of wind energy (e.g., increased tax base, tax revenue, better public services and employment gains) might positively affect jurisdiction-wide housing values. With a focus on school districts in the United States, we compare home values in school districts with wind energy installations, before and after a wind energy installation becomes operational, to home values in other school districts located in the same county but without a wind energy installation to provide some of the first causal evidence on the relationship between wind energy projects and district-wide property values. We find that wind projects lead to economically meaningful increases in district-wide housing values of approximately 3 %, when those values are compared to similar homes located in school districts in same-county without wind energy. The effect is strongly correlated with wind project size. The mechanisms, our research suggests, are likely related to relatively large increases in school district per-pupil revenues and expenditures, which are also correlated with wind project size. We suggest other possible mechanisms for the increased values as well.

Attitudes↗

A dataset for understanding self-reported patterns influencing residential energy decisions

Household occupant behavior and decision-making dynamics substantially impact technology uptake and residential building energy performance. Although significant research underscores the importance of social science in energy studies, few public data with representative samples on household energy decision-making patterns are available. The dataset (UPGRADE-E: Understanding Patterns Guiding Residential Adoption and Decisions about Energy Efficiency) presents 9,919 responses from U.S. residents of single-family and small multifamily homes. Derived from a national-scale internet survey, the dataset contains 391 variables: demographics, building characteristics, home modifications, willingness to adopt new technologies, motivations for making changes, barriers, program participation, trusted information sources, and energy scenarios. Responses were validated via internal consistency checks and comparison with other U.S. national scale datasets. UPGRADE-E advances knowledge of household energy related decision-making, tying demographics, home modifications, and self-reported cognitive drivers together at a scale and breadth that has not been previously achieved. Policymakers and researchers at local, regional, and national levels may leverage this dataset to understand drivers influencing the adoption of key technologies in U.S. homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance Windows -- More than just a Pretty Hole in the Wall

As more stringent building energy codes and better insulation products combine to yield better performing walls, window efficiency is coming into sharper focus. The U.S. Department of Energy has supported several projects through its national laboratories to improve the thermal performance of windows. At Pacific Northwest National Laboratory (PNNL) in Richland, Washington, the PNNL Lab Homes, two fully monitored identical side-by-side manufactured homes, have been used to test the performance of several window improvements including triple-pane windows, storm windows with low-emissivity (low-e) coatings, smart automated interior insulated shades, and exterior shading products. Findings will be presented on these studies, along with impacts. For example, PNNL’s Lab Home research on low-e storm windows has helped to support a new ENERGY STAR certification, industry standards, and utility incentives. Preliminary findings will also be presented on current Lab Homes experiments focusing on exterior shades. The session will also present findings from related field studies and a market assessment of emerging high-efficiency windows technologies and discuss some of PNNL’s planned field studies that will focus on validating the benefits and costs of the emerging thin triple-pane high-R window.

windows, high-r windows, insulating windows, windo↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical evidence that mean soil contaminant concentration is not a conservative indicator of external exposure to wildlife

Adequate information on external exposure is often a limiting factor in ecological risk assessments because of a lack of exposure data for free-ranging animals as they interact with a heterogeneous distribution of contaminants. Instead, most wildlife exposure data are estimated from model simulations. However, empirical exposure data are rarely available to verify model results, or to test fundamental assumptions inherent in exposure assessments. We used novel, GPS-coupled radiation dosimeters on reindeer (Rangifer tarandus) to quantify their external exposure for five months in a Chernobyl fallout affected mountainous area of Norway. The exposure data were then used to test a fundamental assumption in screening-level risk assessments: Mean soil contaminant concentrations can be used to conservatively estimate chronic external exposures to representative animals. External exposure and GPS coordinates were obtained hourly and compared to model simulations of exposure based on airborne surveys of 137 Cs soil contamination. Our objectives were to determine 1) if modelled dose estimates based on mean 137 Cs soil concentrations were conservative, and 2) if modelled dose estimates could be improved by adjusting for spatial–temporal heterogeneity of contaminants using 137 Cs concentrations within reindeers’ GPS-defined home ranges and core areas. We found that external exposure modelled from mean soil contaminant concentrations underestimated exposure by 70% compared to empirical measurements from GPS-dosimeter collars worn on individual animals. Using area-weighted mean contaminant levels within the animals’ home range improved the model estimates, but still underestimated the field dosimeter data by 53%. The best estimate of external exposure was obtained when high-use areas within their home range, along with spatial heterogeneity of the contaminant, was accounted for by using area-weighted mean soil contaminant levels within GPS-derived core areas. Accounting for temporal use of core areas within animals’ home range provided a 24% improvement. Here, a comparison of our analyses to similar work performed on Chernobyl wolves found the two studies concur that risk assessors should be cautious in relying on the paradigm of using averaged soil contaminant levels to provide conservative estimates of external exposure to representative individuals. Results of modelled external exposure based on mean soil contaminant concentrations could misguide assessors and cause inappropriate management decisions.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

The role of above-code labeling programs in reducing CO 2 e emissions in residential buildings

Residential buildings account for 15 % of total U.S. carbon dioxide (CO 2 ) emissions. Voluntary, above-code labeling programs, such as the ENERGY STAR and Zero Energy Ready Home programs, can play a crucial role in reducing the carbon footprint of the new construction residential building sector by encouraging adoption of more energy-efficient and lower emissions building practices and technologies. It's important for the industry to understand the carbon dioxide equivalent (CO 2 e) and energy cost savings potential of these programs. Here, to estimate the potential CO 2 e emissions savings for homes built to above-code labeling program levels, it is imperative to have reliable and accurate tools for estimating emissions from buildings. The open-source OpenStudio-ERI workflow employs detailed physics-based building energy modeling (BEM) to estimate energy usage and operational CO 2 e emissions. In this study we use the OpenStudio-ERI workflow and regional, time-varying emissions factors from the Cambium database to compare the CO 2 e emissions and energy costs of homes built to performance levels required by these above-code labeling programs relative to homes built to model energy codes. We present the results of our analysis and provide a range of emissions and annual energy cost savings for the above-code labeling programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of autonomous vehicles on commute ridesharing with uncertain work end time

The uncertainty in work end time can prevent ridesharing between two commuters with identical home and work locations. This effect can be alleviated by autonomous vehicles (AV): when two commuters share a ride from home to work, if the realized work end times result in a long wait between the two, an additional AV can be easily repositioned from home to work, whereas with regular human-driven vehicles one has to either bear the long wait or request expensive taxi service. This observation implies that AVs have great potential for increasing commute ridesharing. To study this effect, we develop evening commute bottleneck models with uncertain work end time and establish mode choice equilibrium for the round-trip commute. We find that, with regular vehicles, because of the expected waiting cost caused by work end time uncertainty, commuters typically do not share rides even though they have the same home and work locations. With AVs, commuters always share rides for the morning commute, and they also share rides for the evening commute if their work end times turn out to be close; otherwise, they reposition an additional AV to pick one of them up. Finally, our numerical examples show that AVs can encourage commute ridesharing and significantly reduce the expected round-trip travel costs for commuters.

97 MATHEMATICS AND COMPUTING↗

A Hierarchical Optimization Method for Electric Vertical Takeoff and Landing Aircraft Network Design

Electric vertical takeoff and landing aircraft (eVTOLs) are expected to serve urban air mobility in a station-to-station configuration, which makes the optimal network design of eVTOL stations a critical question to explore. Existing approaches often face limitations, such as the inability to interact station locations with demand or difficulty in finding the optimal solution for large study regions. Here, this paper first proposes a mathematical model to generate optimal eVTOL station locations while considering associated potential eVTOL demand, and then proposes a heuristic algorithm, Hierarchical Optimization MEthod (HOME), to efficiently solve the model. With a case study of Southern California, HOME was compared to 1) directly solving the original integer linear programming-based network design problem, and 2) employing the widely used genetic algorithm. Results suggest that HOME can find optimal solutions with limited computational resources. The proposed framework powered by HOME provides a computationally efficient way to support urban air mobility planning.

97 MATHEMATICS AND COMPUTING↗

Contact patterns in wild pigs ( Sus scrofa ) from GPS tracking reveal spatial and temporal dynamics of social behaviour

Wild pig ( Sus scrofa Linnaeus, 1758) social behaviour affects disease transmission and landscape-level population management. Recent research has incorporated analysis of social structure to better understand the risk of disease transmission in wild pigs, although the relationship between overall social structure of wild pigs remains unclear. Here, we seek to improve understanding of the spatial and temporal dynamics of wild pig social structure and contact rates to better inform management strategies. Using GPS tracking data, we measured home range overlap, and estimated contact rates of wild pigs at four study sites in the southern USA to identify pairwise social associations (i.e., contacts) based on synchronous movement. Contact rate was strongly associated with home range overlap, but exhibited substantial variation, especially at moderate levels of home range overlap. We found that female–female dyads had higher contact rates and longer duration phases of social association compared to female–male and male–male dyads. We found male–male dyads tended to experience social associations farther from their home range centers than female–female or female–male dyads. Social associations between wild pig dyads are highly dynamic in their spatial and temporal structure. Further, dyads with strong social associations still experience substantial time apart. Our findings highlight the challenges of predicting spatial and social associations in wild pig social pairs due to their dynamic social structure over space and time.

McIlraith, Jack R.↗

Weatherization Assistant NEAT/MHEA

The software provides a measure selection technique indicating cost effective retrofit activities that can be applied to a home using a standard Savings to Investment Ratio (SIR). Users must provide an input file describing the characteristics of the home to be evaluated. The software takes the input data provided and calculates energy savings and cost savings predicted for a standard set of measures given the input parameters. The Weatherization Assistant computes estimates of pre-retrofit whole building space heating and cooling energy consumptions based on the house description data supplied by the user. The consumptions are computed using a monthly heating and cooling variable base degree-day method by algorithms similar to those developed for the CIRA program [LBL, 1982]. The building consumptions are needed in computing the energy savings from measures affecting the efficiencies of the heating and cooling equipment. Weatherization Assistant then computes the energy savings and costs for each individual measure applicable to the building described as if it were the only measure installed in the house. From these energy savings, a discounted dollar savings over the life of each measure is computed. The ratio of this dollar savings to the cost of installing the measure, the "savings-to-investment ratio" (SIR), is used in an initial ranking of the measures' effectiveness. The "interacted" savings and SIR of measures are then determined assuming the measures are added to the house collectively, in order of their ranking, e.g., the second ranked measure is installed in the house initially described by the user after having been modified by the first ranked measure. If this second-ranked measure's updated SIR is greater than a user-defined limit, the measure is left implemented, else it is removed so that the next measure's effectiveness is not dependent on it. The choice between two mutually exclusive measures (such as different levels of insulation) is made on the basis of their "net present value" (NPV), the difference of life-time savings and installation cost, rather than their SIR. This has been shown to be the more correct criterion on which to base the selection between two measures, both of which cannot be installed. The audit computes and reports to the user the energy savings, discounted dollar savings, installation cost, and SIR for each measure considered cost-effective. For those with SIR greater than the user-designated cutoff, a materials list gives the material name, type, and quantity required for installation of the measure. Weatherization Assistant permits entry of pre-retrofit billing data for gas or electrically heated homes or homes with electric air-conditioning. The user may then make the decision to have the savings of the measures adjusted to reflect the difference in billed consumption and that predicted by the program.

Gettings, Michael↗

Simulations of short-term exposure to NO 2 and PM 2.5 to inform capture efficiency standards

The California building code requires all new or renovated residential dwelling units to have kitchen exhaust ventilation to manage air pollutants and moisture generated during cooking. Current performance requirements are specified as a minimum airflow and maximum sound level. This report presents an analysis to support consideration of adding a capture efficiency requirement to the code. The analysis uses a physics-based simulation model to calculate air pollutant concentrations in homes that result from cooking and the inflow of outdoor air, mediated by loss and removal process including deposition, dwelling unit ventilation, and the use of a range hood with varying levels of capture efficiency. Calculated pollutant concentrations are compared to relevant, health-based guidelines. The analysis considers the highest 1-hour concentration of nitrogen dioxide (NO 2 ), which is a product of natural gas combustion and the highest 24-hour concentrations of fine particulate matter (PM 2.5 ) which is emitted in substantial quantities from frying, broiling and grilling among other cooking activities. For NO 2 , the analysis considers cooking of a dinner for 3-4 persons consisting of pasta, meat sauce, a par-boiled vegetable, and baked garlic bread. For PM 2.5 , the analysis considers a day in which breakfast emitted particles at the 80th percentile and lunch and dinner entailed particle emissions at the 50th percentile of cooking emission events reported in the literature. Model simulations were performed to determine the level of range hood capture efficiency that will allow these cooking scenarios to occur in the vast majority (>99%) of new homes being built in California while maintaining pollutant concentrations below the health-based guidelines, if the range hood is used throughout cooking. All homes were assumed to have dwelling unit ventilation at the rate required in the building code. Simulation model input parameters were specified using a Monte Carlo approach to represent a range of housing characteristics, outdoor conditions, and indoor pollutant dynamics. Simulation results suggest that requiring a minimum capture efficiency of at least 70% is needed to avoid unacceptably high NO 2 (1-h average concentration of 100 ppb or higher) and at least 60% to avoid unacceptably high PM 2.5 (24-h average of 25 μg/m³ or higher). These results were driven by multi-family homes, which have a smaller volume of air to dilute any pollutants not captured and removed at the cooking area, resulting in higher concentrations.

54 ENVIRONMENTAL SCIENCES↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

This project explored the use of minisplit ductless heat pumps in combination with small through-wall transfer fans to provide space conditioning in small single-story homes including manufactured homes and homes built by Habitat for Humanity. The objectives were to reduce space conditioning energy consumption by 50% compared to the 2009 International Energy Conservation Code while maintaining home affordability and thermal comfort. The strategy to achieve this goal also included a highly efficient thermal envelope to reduce space conditioning loads.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗