Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high performance visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Target Diagnostics Supports NIF's Path to Ignition

The physics requirements derived from the National Ignition Facility (NIF) experimental campaigns are leading to a wide variety of target diagnostics. Software development for the control and analysis of these diagnostics is included in the NIF Integrated Computer Control System, Diagnostic Control System and Data Visualization. These projects implement the configuration, controls, data analysis and visual representation of most of these diagnostics. To date, over 40 target diagnostics have been developed to support NIF experiments. In 2011 diagnostics were developed or enhanced to measure Ignition performance in a high neutron yield environment. Performance is optimized around four key variables: Adiabat (a) which is the strength and timing of four shocks delivered to the target, Velocity (V) of the imploding target, Mix (M) is the uniformity of the burn, and the Shape (S) of the imploding Deuterium Tritium (DT) hot spot. The diagnostics used to measure each of these parameters is shown in figure 1. Adiabat is measured using the Velocity Interferometer System for Any Reflector (VISAR) diagnostic consisting of three streak cameras. To provide for more accurate adiabat measurements the VISAR streak cameras were enhanced in FY11 with a ten comb fiducial signal controller to allow for post shot correction of the streak camera sweep non-linearity. Mix is measured by the Neutron Time of Flight (NTOF) and Radiochemical Analysis of Gaseous Samples (RAGS) diagnostics. To accommodate high neutron yield shots, NTOF diagnostic controls are being modified to use Mach Zehnder interferometer signals to allow the digitizers to be moved from near the target chamber to the neutron shielded diagnostic mezzanine. In December 2011 the first phase of RAGS diagnostic commissioning will be completed. This diagnostic will analyze the tracers that are added to NIF target capsules that undergo nuclear reactions during the shot. These gases are collected and purified for nuclear counting by the RAGS system. Three new instrument controllers were developed and commissioned to support this diagnostic. A residual-gas analyzer (RGA) instrument measures the gas content at various points in the system. The Digital Gamma Spectrometer instrument measures the radiological spectrum of the decaying gas isotopes. A final instrument controller was developed to interface to a PLC based Gas collection system. In order to support the implosion velocity measurements an additional Gated X-ray Detector (GXD) diagnostic was tested and commissioned. This third GXD views the target through a slit contained in its snout and allows the other GXD diagnostics to be used for measuring the shape on the same shot. In order to measure the implosion shape in a high neutron environment, Actide Readout In A Neutron Environment (ARIANE) and Neutron Imaging (NI) diagnostics were commissioned. The controls for ARIANE, a fixed port gated x-ray imager, contain a neutron shielded camera and micro channel plate pulser with its neutron sensitive electronics located in the diagnostic mezzanine. The NI diagnostic is composed of two Spectral Instruments SI-1000 cameras located 20M from the target and provides neutron images of the DT hot spot for high yield shots. The development and commissioning of these new or enhanced diagnostics in FY11 have provided meaningful insight that facilitates the optimization of the four key Ignition variables. In FY12 they will be adding three new diagnostics and enhancing four existing diagnostics in support of the continuing optimization series of campaigns.

42 ENGINEERING↗

Early Experiences Porting the NAMD and VMD Molecular Simulation and Analysis Software to GPU-Accelerated OpenPOWER Platforms, In: ISC High Performance 2016: High Performance Computing

All-atom molecular dynamics simulations of biomolecules provide a powerful tool for exploring the structure and dynamics of large protein complexes within realistic cellular environments. Unfortunately, such simulations are extremely demanding in terms of their computational requirements, and they present many challenges in terms of preparation, simulation methodology, and analysis and visualization of results. We describe our early experiences porting the popular molecular dynamics simulation program NAMD and the simulation preparation, analysis, and visualization tool VMD to GPU-accelerated OpenPOWER hardware platforms. We report our experiences with compiler-provided autovectorization and compare with hand-coded vector intrinsics for the POWER8 CPU. We explore the performance benefits obtained from unique POWER8 architectural features such as 8-way SMT and its value for particular molecular modeling tasks. Finally, we evaluate the performance of several GPU-accelerated molecular modeling kernels and relate them to other hardware platforms.

Computer Science↗

Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stable, high-performance, dendrite-free, seawater-based aqueous batteries

Metal anode instability, including dendrite growth, metal corrosion, and hetero-ions interference, occurring at the electrolyte/electrode interface of aqueous batteries, are among the most critical issues hindering their widespread use in energy storage. Herein, a universal strategy is proposed to overcome the anode instability issues by rationally designing alloyed materials, using Zn-M alloys as model systems (M = Mn and other transition metals). An in-situ optical visualization coupled with finite element analysis is utilized to mimic actual electrochemical environments analogous to the actual aqueous batteries and analyze the complex electrochemical behaviors. The Zn-Mn alloy anodes achieved stability over thousands of cycles even under harsh electrochemical conditions, including testing in seawater-based aqueous electrolytes and using a high current density of 80 mA cm –2 . The proposed design strategy and the in-situ visualization protocol for the observation of dendrite growth set up a new milestone in developing durable electrodes for aqueous batteries and beyond.

25 ENERGY STORAGE↗

Exploration of High-Dimensional Scalar Function for Nuclear Reactor Safety Analysis and Visualization

The next generation of methodologies for nuclear reactor Probabilistic Risk Assessment (PRA) explicitly accounts for the time element in modeling the probabilistic system evolution and uses numerical simulation tools to account for possible dependencies between failure events. The Monte-Carlo (MC) and the Dynamic Event Tree (DET) approaches belong to this new class of dynamic PRA methodologies. A challenge of dynamic PRA algorithms is the large amount of data they produce which may be difficult to visualize and analyze in order to extract useful information. We present a software tool that is designed to address these goals. We model a large-scale nuclear simulation dataset as a high-dimensional scalar function defined over a discrete sample of the domain. First, we provide structural analysis of such a function at multiple scales and provide insight into the relationship between the input parameters and the output. Second, we enable exploratory analysis for users, where we help the users to differentiate features from noise through multi-scale analysis on an interactive platform, based on domain knowledge and data characterization. Our analysis is performed by exploiting the topological and geometric properties of the domain, building statistical models based on its topological segmentations and providing interactive visual interfaces to facilitate such explorations. We provide a user’s guide to our software tool by highlighting its analysis and visualization capabilities, along with a use case involving dataset from a nuclear reactor safety simulation.

97 MATHEMATICS AND COMPUTING↗

Effects of thermal and athermal processing on the formation of buried SiC layers

In the present study, systematic investigations on 100 keV C ion implanted Si (100) substrates annealed subsequently at a temperature of 1000 deg. C for 2 h or athermally processed using 110 MeV Ni{sup 8+} ion irradiation have been performed. A detailed analysis using the techniques of x-ray diffraction, Fourier transform infrared spectroscopy, and transmission electron microscopy (TEM) at high resolutions is performed. The observations suggest the formation of cubic silicon carbide ({beta}-SiC) crystallites surrounded by an amorphous background in the samples thermally annealed at 1000 deg. C. However, ion irradiation did not influence the as-implanted layers to any significant extent. Various defects formed after annealing inside C implanted Si such as missing planes, edge dislocations, and grain boundaries during thermal crystallization are visualized through high resolution TEM.

36 MATERIALS SCIENCE↗

Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 {+-} 9 min in the gadolinium-enhanced saline solution group and 22 {+-} 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping Metals Incorporation of a Whole Single Catalyst Particle Using Element Specific X-ray Nanotomography

Full-field transmission X-ray microscopy has been used to determine the 3D structure of a whole individual fluid catalytic cracking (FCC) particle at high spatial resolution and in a fast, noninvasive manner, maintaining the full integrity of the particle. Using X-ray absorption mosaic imaging to combine multiple fields of view, computed tomography was performed to visualize the macropore structure of the catalyst and its availability for mass transport. We mapped the relative spatial distributions of Ni and Fe using multiple-energy tomography at the respective X-ray absorption K-edges and correlated these distributions with porosity and permeability of an equilibrated catalyst (E-cat) particle. Both metals were found to accumulate in outer layers of the particle, effectively decreasing porosity by clogging of pores and eventually restricting access into the FCC particle.

02 PETROLEUM↗

Sim-Situ: A Framework for the Faithful Simulation of in situ Processing

The amount of data generated by numerical simulations in various scientific domains led to a fundamental redesign of how the analysis and visualization of simulation outputs are performed. The throughput and capacity of storage subsystems have not evolved as fast as the computing power in extreme-scale supercomputers, making the classical post-hoc approach highly inefficient. In situ processing has then emerged as a solution in which simulation and data analysis/visualization are intertwined for better performance and greater interactivity.Determining the best allocation, i.e., how many resources to allocate to simulation and analysis respectively, mapping, i.e., where and at which frequency to run the analysis/visualization, and data transfer mode is a complex task whose performance assessment is crucial to the efficient execution of in situ processing. However, such a performance evaluation of different strategies usually relies either on directly running them on the targeted execution environments, which can rapidly become extremely time- and resource-consuming, or on resorting to simplified models of the components of an in situ application, which can lack of realism. In both cases, the validity of the performance evaluation is limited.In this paper, we present Sim-Situ, a simulation-based framework for the faithful performance evaluation of in situ processing strategies. We designed Sim-Situ to reflect the typical features of in situ processing systems. Thanks to its modular design, Sim-situ has the necessary flexibility to easily and faithfully evaluate the behavior and performance of various allocation, mapping, and data transfer strategies. We illustrate the simulation capabilities of Sim-Situ on a Molecular Dynamics use case. We study the impact of different strategies on performance and show how users can leverage Sim-Situ to determine interesting tradeoffs when adding analysis/visualization components to their application.

Honoré, Valentin↗

TU-CD-207-08: Intrinsic Image Quality Comparison of Synthesized 2-D and FFDM Images

Purpose: With the combined interest of managing patient dose, maintaining or improving image quality, and maintaining or improving the diagnostic utility of mammographic data, this study aims to compare the intrinsic image quality of Hologic’s synthesized 2-D (C-View) and 2-D FFDM images in terms of resolution, contrast, and noise. Methods: This study utilized a novel 3-D printed anthropomorphic breast phantom in addition to the American College of Radiology (ACR) mammography accreditation phantom. Analysis of the 3-D anthropomorphic phantom included visual assessment of resolution and analysis of the normalized noise power spectrum. Analysis of the ACR phantom included both visual inspection and objective automated analysis using in-house software. The software incorporates image- and object-specific CNR visibility thresholds which account for image characteristics such as noise texture which affect object visualization. T- test statistical analysis was also performed on ACR phantom scores. Results: The spatial resolution of C-View images is markedly lower (at least 50% worse) than that of FFDM. And while this is generally associated with the benefit of reduced relative noise magnitude, the noise in C-View images tends to have a more mottled (predominantly low-frequency) texture. In general, for high contrast objects, C-View provides superior visualization over FFDM; however this benefit diminishes for low contrast objects and is applicable only to objects that are sufficiently larger than the spatial resolution threshold. Based on both observer and automated ACR phantom analysis, between 50–70% of C-View images failed to meet ACR minimum accreditation requirements – primarily due to insufficient (unbroken) fiber visibility. Conclusion: Compared to FFDM, C-View offers better depiction of objects of certain size and contrast, but provides poorer overall resolution and noise properties. Based on these findings, the utilization of C-View images in the clinical setting requires careful consideration, especially if considering the discontinuation of FFDM imaging.

60 APPLIED LIFE SCIENCES↗

Naturalistic Decision Making For Power System Operators

Abstract: Motivation -- As indicated by the Blackout of 2003, the North American interconnected electric system is vulnerable to cascading outages and widespread blackouts. Investigations of large scale outages often attribute the causes to the three T’s: Trees, Training and Tools. A systematic approach has been developed to document and understand the mental processes that an expert power system operator uses when making critical decisions. The approach has been developed and refined as part of a capability demonstration of a high-fidelity real-time power system simulator under normal and emergency conditions. To examine naturalistic decision making (NDM) processes, transcripts of operator-to-operator conversations are analyzed to reveal and assess NDM-based performance criteria. Findings/Design -- The results of the study indicate that we can map the Situation Awareness Level of the operators at each point in the scenario. We can also identify clearly what mental models and mental simulations are being performed at different points in the scenario. As a result of this research we expect that we can identify improved training methods and improved analytical and visualization tools for power system operators. Originality/Value -- The research applies for the first time, the concepts of Recognition Primed Decision Making, Situation Awareness Levels and Cognitive Task Analysis to training of electric power system operators. Take away message -- The NDM approach provides an ideal framework for systematic training management and mitigation to accelerate learning in team-based training scenarios with high-fidelity power grid simulators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding failure in austenitic steels: Key considerations for molten salt storage in CSP applications

Owing to their excellent properties, austenitic stainless steels are extensively used in boilers, furnaces, molten salt tanks, and other applications that are subjected to extreme mechanical loads and high-temperature conditions. Their high corrosion and creep resistance make them suitable for high-temperature operating environments. Additionally, good fatigue resistance and favorable mechanical and visual properties are essential. However, the premature failure of several components at elevated temperatures has been previously reported. Although the failure analysis of components in service is complex, processes such as cold work and welding have been identified as contributing factors to the performance degradation of these steels. This study aims to analyze the various documented failure modes and mechanisms in austenitic steels, including creep, cracking, stress relaxation cracking, and fatigue, to better understand the multi-objective design requirements for these alloys as structural materials for high-temperature molten salt tanks in Concentrating Solar Power (CSP) plants. Stabilized austenitic grades, such as AISI 347H, demonstrate superior resistance to creep and corrosion-related degradation when compared to non-stabilized grades like AISI 316L at temperatures relevant to concentrated solar power (CSP) applications. In contrast, nickel-based alloys offer enhanced corrosion resistance, albeit at a higher cost. This review underscores that creep, stress relaxation cracking, and thermo-mechanical fatigue are the predominant long-term failure risks in CSP hot tanks.

14 SOLAR ENERGY↗

Evaluation of OpenAI Codex for HPC Parallel Programming Models Kernel Generation

We evaluate AI-assisted generative capabilities on fundamental numerical kernels in high-performance computing (HPC), including AXPY, GEMV, GEMM, SpMV, Jacobi Stencil, and CG. We test the generated kernel codes for a variety of language-supported programming models, including (1) C++ (e.g., OpenMP [including offload], OpenACC, Kokkos, SyCL, CUDA, and HIP), (2) Fortran (e.g., OpenMP [including offload] and OpenACC), (3) Python (e.g., numpy, Numba, cuPy, and pyCUDA), and (4) Julia (e.g., Threads, CUDA.jl, AMDGPU.jl, and KernelAbstractions.jl). We use the GitHub Copilot capabilities powered by the GPT-based OpenAI Codex available in Visual Studio Code as of April 2023 to generate a vast amount of implementations given simple + + prompt variants. To quantify and compare the results, we propose a proficiency metric around the initial 10 suggestions given for each prompt. Results suggest that the OpenAI Codex outputs for C++ correlate with the adoption and maturity of programming models. For example, OpenMP and CUDA score really high, whereas HIP is still lacking. We found that prompts from either a targeted language such as Fortran or the more general purpose Python can benefit from adding code keywords, while Julia prompts perform acceptably well for its mature programming models (e.g., Threads and CUDA.jl). We expect for these benchmarks to provide a point of reference for each programming model's community. Overall, understanding the convergence of large language models, AI, and HPC is crucial due to its rapidly evolving nature and how it is redefining human-computer interactions.

Godoy, William↗

Dynamic functional imaging of brain glucose utilization using fPET-FDG

We report that glucose is the principal source of energy for the brain and yet the dynamic response of glucose utilization to changes in brain activity is still not fully understood. Positron emission tomography (PET) allows quantitative measurement of glucose metabolism using 2-[18F]-fluorodeoxyglucose (FDG). However, FDG PET in its current form provides an integral (or average) of glucose consumption over tens of minutes and lacks the temporal information to capture physiological alterations associated with changes in brain activity induced by tasks or drug challenges. Traditionally, changes in glucose utilization are inferred by comparing two separate scans, which significantly limits the utility of the method. We report a novel method to track changes in FDG metabolism dynamically, with higher temporal resolution than exists to date and within a single session. Using a constant infusion of FDG, we demonstrate that our technique (termed fPET-FDG) can be used in an analysis pipeline similar to fMRI to define within-session differential metabolic responses. We use visual stimulation to demonstrate the feasibility of this method. Ultimately, this new method has a great potential to be used in research protocols and clinical settings since fPET-FDG imaging can be performed with most PET scanners and data acquisition and analysis are straightforward. fPET-FDG is a highly complementary technique to MRI and provides a rich new way to observe functional changes in brain metabolism.

2-[18F]-fluorodeoxyglucose (FDG)↗

Galaxy morphological classification in deep-wide surveys via unsupervised machine learning

ABSTRACT Galaxy morphology is a fundamental quantity, which is essential not only for the full spectrum of galaxy-evolution studies, but also for a plethora of science in observational cosmology (e.g. as a prior for photometric-redshift measurements and as contextual data for transient light-curve classifications). While a rich literature exists on morphological-classification techniques, the unprecedented data volumes, coupled, in some cases, with the short cadences of forthcoming ‘Big-Data’ surveys (e.g. from the LSST), present novel challenges for this field. Large data volumes make such data sets intractable for visual inspection (even via massively distributed platforms like Galaxy Zoo), while short cadences make it difficult to employ techniques like supervised machine learning, since it may be impractical to repeatedly produce training sets on short time-scales. Unsupervised machine learning, which does not require training sets, is ideally suited to the morphological analysis of new and forthcoming surveys. Here, we employ an algorithm that performs clustering of graph representations, in order to group image patches with similar visual properties and objects constructed from those patches, like galaxies. We implement the algorithm on the Hyper-Suprime-Cam Subaru-Strategic-Program Ultra-Deep survey, to autonomously reduce the galaxy population to a small number (160) of ‘morphological clusters’, populated by galaxies with similar morphologies, which are then benchmarked using visual inspection. The morphological classifications (which we release publicly) exhibit a high level of purity, and reproduce known trends in key galaxy properties as a function of morphological type at z < 1 (e.g. stellar-mass functions, rest-frame colours, and the position of galaxies on the star-formation main sequence). Our study demonstrates the power of unsupervised machine learning in performing accurate morphological analysis, which will become indispensable in this new era of deep-wide surveys.

Martin, G.↗

Machine learning elastic constants of multi-component alloys

The present manuscript explores application of machine learning methods for determining elastic constants and other derived mechanical properties of multi-component alloys. Here, a number of machine learning models, including linear regression, neural network and random forest based models, are trained and tested on a dataset of binary alloys generated using density functional theory (DFT) calculations and spanning over a large number of elemental species in the periodic table. Starting with a wide range of simple and easily accessible compositionally-averaged elemental features, a correlation-based feature selection strategy was used to systematically down-select a set of most relevant features towards the prediction of the elasticity tensor components. The true predictive performance and the associated uncertainties of the models were established by testing on unseen data and bootstrapping, respectively. A single and pair-wise feature partial dependence analysis was performed to visualize the average property trends in the multi-dimensional feature space in order to further understand the achieved predictive performance. The utility of the trained model is further demonstrated by obtaining sufficiently accurate yet highly efficient approximations for bulk modulus, Young’s modulus, shear modulus and Poisson’s ratio for alloys beyond the binary space (i.e., two-component alloys) on which the model was originally trained. More importantly, we test and validate the predictive performance of the developed model directly against the experimentally measured elastic constants of technologically relevant multi-component alloys (such as, Ni- and Ti-based alloys). Finally, utility of such a data-enabled route is demonstrated by predicting the possible range of various elastic properties for vast composition space available within the five component Ni-Cr-Fe-Mo-W alloy system in a high-throughput manner.

36 MATERIALS SCIENCE↗

Probing ternary solvent effect in high V oc polymer solar cells using advanced AFM techniques

This work describes a simple method to develop a high V oc low band gap PSCs. In addition, two new atomic force microscopy (AFM)-based nanoscale characterization techniques to study the surface morphology and physical properties of the structured active layer are introduced. With the help of ternary solvent processing of the active layer and C 60 buffer layer, a bulk heterojunction PSC with V oc more than 0.9 V and conversion efficiency 7.5% is developed. In order to understand the fundamental properties of the materials ruling the performance of the PSCs tested, AFM-based nanoscale characterization techniques including Pulsed-Force-Mode AFM (PFM-AFM) and Mode-Synthesizing AFM (MSAFM) are introduced. Interestingly, MSAFM exhibits high sensitivity for direct visualization of the donor–acceptor phases in the active layer of the PSCs. Lastly, conductive-AFM (cAFM) studies reveal local variations in conductivity in the donor and acceptor phases as well as a significant increase in photocurrent in the PTB7:ICBA sample obtained with the ternary solvent processing.

25 ENERGY STORAGE↗

Framework for Analysis and Visualization of Simulation Data (VizAly)

As supercomputing resources increase, cosmological scientists are able to run more detailed and larger simulations generating massive amounts of data. Analyzing these simulations with an available open-source toolkit is important for collaborative Department of Energy scientific discovery across labs, universities, and other partners. Developed software as a part of this collection include: comparing data with other existing simulations, verifying and validating results with observation databases, new halo finder algorithms, and using analytical tools to get insights into the physics of the cosmological universe. The goal of this software project is to provide a set of open-source libraries, tools, and packages for large-scale cosmology that allows scientists to visualize, analyze, and compare large-scale simulation and observational data sets. Developed software will provide a variety of methods for processing, visualization, and analysis of astronomical observation and cosmological simulation data. These tools are intended for deployment on multiple scientific computing platforms, including but not limited to personal computers, cloud computing, experimental sites (telescopes) and high performance supercomputers.

Wendelberger, Joanne↗