Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid upgrades”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Fluid-kinetic modeling of a high power density radio frequency inductively coupled positive hydrogen ion source

High power density radio-frequency (RF) inductively coupled positive ion sources are attractive candidates for next-generation neutral beam injection (NBI) systems, where higher injected power and longer pulse lengths are desired without sacrificing source reliability. Operating at absorbed power densities of order $\gt 1~\mathrm{W\,cm}^{-3}$ places these sources in a regime with stronger gas heating, higher dissociation, and non-Maxwellian electron energy distributions. The Large Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma source designed to explore this high power density regime and to provide guidance for a positive ion source upgrade for the DIII-D NBI system. LUPIN is designed to operate at up to 20 kW of RF power at 2 MHz, coupling energy through a cylindrical quartz vessel to achieve target ion current densities of $2100\,\mathrm{A\,m}^{-2}$ . This paper presents fluid-kinetic modeling of LUPIN using the hybrid plasma equipment model where electrons are treated kinetically, and the simulations reveal that electron energy distribution function transitions from nearly Maxwellian in the core to bi-Maxwellian towards the edge. Parametric simulations investigate the effects of RF power, gas pressure, and frequency on plasma density, ion flux, and uniformity. Parametric sweeps reveal that increasing power shifts the primary ionization channel from molecular to atomic with diminishing flux gains due to skin-depth contraction and gas rarefaction. Higher frequency localizes heating and increases $\mathrm{H}_2^+$ and $\mathrm{H}_3^+$ delivery to the grid, while elevated pressure boosts ionization yet hinders ion transport due to increase in collisionality.

inductively coupled plasma↗

Estimation of solar photovoltaic energy curtailment due to volt–watt control

The widespread deployment of autonomous inverter‐based solutions for mitigating voltage and frequency excursions caused by high‐penetration photovoltaic (PV) systems has drawn increased attention due to their potential impact on PV production. It is now important to quantify the amount of solar energy curtailed as a result of the activation of inverter‐based grid support functions (GSFs). This study proposes a methodology for estimating the impact of volt–watt on customer PV energy curtailment using smart meter voltage data. This method estimates maximum possible curtailment for a given volt–watt curve based on the customer smart meter voltage during the time period of interest. This study compares the proposed methodology with field measurements using irradiance and customer inverter data from Hawaii as well as with results from a previous simulation‐driven study on the impact of advanced inverter GSF activation on PV energy curtailment. Results show that the proposed method for estimating lost PV production caused by volt–watt control aligns reasonably well with field measurements and computer simulations for hundreds of customers. The proposed method could be used to estimate customer energy curtailment, which could inform future compensation mechanisms for utilities leveraging customer‐sited resources to mitigate high voltage and defer infrastructure upgrades.

Emmanuel, Michael↗

Time-varying value of electric energy efficiency

Electric energy efficiency resources save energy and may reduce peak demand. Historically, quantification of energy efficiency benefits has largely focused on the economic value of energy savings during the first year and lifetime of the installed measures. Due in part to the lack of publicly available research on end-use load shapes (i.e., the hourly or seasonal timing of electricity savings) and energy savings shapes, consideration of the impact of energy efficiency on peak demand reduction (i.e., capacity savings) has been more limited. End-use load research and the hourly valuation of efficiency savings are used for a variety of electricity planning functions, including load forecasting, demand-side management and evaluation, capacity and demand response planning, long-term resource planning, renewable energy integration, assessing potential grid modernization investments, establishing rates and pricing, and customer service. This study reviews existing literature on the time-varying value of energy efficiency savings, provides examples in four geographically diverse locations of how consideration of the time-varying value of efficiency savings impacts the calculation of power system benefits, and identifies future research needs to enhance the consideration of the time-varying value of energy efficiency in cost-effectiveness screening analysis. Findings from this study include: -The time-varying value of individual energy efficiency measures varies across the locations studied because of the physical and operational characteristics of the individual utility system (e.g., summer or winter peaking, load factor, reserve margin) as well as the time periods during which savings from measures occur. -Across the four locations studied, some of the largest capacity benefits from energy efficiency are derived from the deferral of transmission and distribution system infrastructure upgrades. However, the deferred cost of such upgrades also exhibited the greatest range in value of all the components of avoided costs across the locations studied. -Of the five energy efficiency measures studied, those targeting residential air conditioning in summer-peaking electric systems have the most significant added value when the total time-varying value is considered. -The increased use of rooftop solar systems, storage, and demand response, and the addition of electric vehicles and other major new electricity-consuming end uses are anticipated to significantly alter the load shape of many utility systems in the future. Data used to estimate the impact of energy efficiency measures on electric system peak demands will need to be updated periodically to accurately reflect the value of savings as system load shapes change. -Publicly available components of electric system costs avoided through energy efficiency are not uniform across states and utilities. Inclusion or exclusion of these components and differences in their value affect estimates of the time-varying value of energy efficiency. -Publicly available data on end-use load and energy savings shapes are limited, are concentrated regionally, and should be expanded.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic hosting capacity analysis for distributed photovoltaic resources—Framework and case study

Distributed photovoltaic systems can cause adverse distribution system impacts, including voltage violations at customer locations and thermal overload of lines, transformers, and other equipment resulting from high current. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current static methods for determining hosting capacity tend to either consider infrequent worst-case snapshots in time and/or capture coarse time and spatial resolution. Because the duration of violations cannot be captured with these traditional methods, the metric thresholds used in these studies conservatively use the strictest constraints given in operating standards, even though both worse voltage performance and higher overloads may be temporarily acceptable. However, assessing the full details requires accurately capturing time-dependence, voltage-regulating equipment operations, and performance of advanced controls-based mitigation techniques. In this paper, we propose a dynamic distributed photovoltaic hosting capacity methodology to address these issues by conducting power flow analysis for a full year. A key contribution is the formulation of time aware metrics to take these annual results and identify the hosting capacity. Through a case study, we show that this approach can more fully capture grid impacts of distributed photovoltaic than traditional methods and the dynamic hosting capacity was 60%–200% higher than the static hosting capacity in this case study.

14 SOLAR ENERGY↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

ZIPPER: Zonal isolation with plug and perf in enhanced reservoirs (Final Technical Report)

Modern multistage hydraulic stimulation treatments in cased wellbores require an effective method of isolating stages between treatments. A commonly used method in the oil and gas industry, plug and perf, is not currently viable for Enhanced Geothermal Systems (EGS) due to limitations of a critical component of the system – the ball drop (flow through) frac plug. Commercially available ball drop frac plugs do not meet the temperature or wellbore diameter requirements needed for use in EGS stimulations. For example, one particular drillable bridge and frac plug line from a large tool developer is only rated to 175 °C, while another is only available up to casing sizes of 5 ½” and rated up to 204 °C. We developed, prototyped, and field tested an upgraded ball drop frac plug to meet the requirements of EGS stimulations, including high-temperature (225+ °C), differential pressure (6000+ psi), and wellbore diameters ranging from 6 5/8” to 10 5/8”. We focused on designs and materials to optimize drillability, a key cost driver in plug and perf systems. The primary objective was to upgrade a drillable frac plug (currently rated to a temperature of 175°C and a pressure of 10,000 psi in 7” casing) to withstand temperatures of 225+°C. The upgraded frac plug was tested in the laboratory as well as in a field trial at a geothermal field. Engineering design and fabrication of the new plug was completed in 2019. Lab testing, validation, and qualification of the plug was completed in 2020. Ultimately the plug was successfully run during a multistage stimulation treatment in a fully horizontal EGS well in 2022. Prior to this project, a ball-drop, flow-through stimulation plug had never been used in a geothermal well. At the conclusion of this project, three different types of zonal isolation plugs were evaluated under full-scale operating conditions across 16 stimulation treatment stages in a first-of-a-kind EGS project called Project Red. This trial included the newly designed high-temperature, large-diameter plug. The plugs met all of 5 the technical requirements for commercial viability. Project Red has since been fully commissioned and is generating electricity on the Nevada grid - the first EGS project to successfully deliver power to the grid in the US.

15 GEOTHERMAL ENERGY↗

Phase I Microgrid Cost Study: Data Collection and Analysis of Microgrid Costs in the United States

The U.S. Department of Energy (DOE) Office of Electricity Microgrid Cost Study project is looking at identifying the costs of components, integration and installation of U.S. microgrids and project cost improvements and technical accelerators over the next 5 years and beyond. This information could then be used by the DOE among others, to develop R&D agendas for the development of the next generation microgrids that provide cost effective, reliable and clean energy solutions. Microgrids are gaining in popularity because of their adaptability and flexible expandability, the need for increased electricity reliability, the increased affordability of distributed energy resources (DERs) and grid intelligence devices, goals to reduce greenhouse gas emissions, and other factors. The U.S. Department of Energy commissioned the National Renewable Energy Laboratory to complete a microgrid cost study and develop a microgrid cost model. The goal is to elucidate the variables that have the highest impact on costs as well as potential areas for cost reduction. This study consists of two phases. Phase I comprises the collection and analysis of data from microgrid projects built in the United States and is the subject of this report. In Phase II, NREL will assess current barriers facing the industry and identify potential solutions with help from industry representatives. Microgrid components are classified as follows in the form used to collect cost data from industry representatives for NREL's microgrid cost database: DERs: diesel, natural gas, combined heat and power (CHP), biofuel, solar photovoltaic (PV), wind, and fuel cell and energy storage; microgrid controller: primary, secondary, or tertiary; additional infrastructure: distribution system infrastructure, information technology communications upgrades, metering, etc.; soft costs: engineering, construction, commissioning, and regulatory. The purposes of Phase I are to better determine the contribution of individual components to total project size and to identify cost differences in projects within the same market segment. Phase II will use the results of Phase I to have an initial indication of the costs that might be driving the cost of development the most.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Net-zero Microgrid Program Report: Microrred de la Montaña Feasibility Study (Executive Summary Extended)

This feasibility study provides the technical and economic rationale for the Microrred de la Montaña as a viable solution for supplying reliable and resilient electricity to an underserved region in Puerto Rico – a region that is the first to be disconnected from the grid and the last to be restored, enduring months long outages. It begins the process of the development of the microgrid through conceptual design, engineering, detailed electrical design, implementation, and operation. The Microrred de la Montaña is organized under the governance of the Cooperativa Hidroeléctrica de la Montaña (Cooperativa) which has legal status as a cooperative and power provider under the laws of Puerto Rico. The members are the municipalities of Adjuntas, Jayuya, Lares and Utuado with a combined population of 90,000. These municipalities are in central Puerto Rico – a mountainous region that is extremely vulnerable to weather events and excessive, long-duration power outages and are among the poorest and most disadvantaged regions in Puerto Rico. Funding from external sources is necessary to acquire the resources for a resilient power delivery system. Regulatory support is necessary to establish operational relationships with the incumbent power providers. The Microrred de la Montaña is envisioned as a resilient microgrid that manages distributed energy resources – local solar, storage, and hydroelectricity over an upgraded distribution network within the boundaries of four municipalities. This feasibility study provides the results of an extensive techno-economic analysis to form a sound basis for decision-making by community leaders, their constituents, funding and investment agencies, and regulators to realize the benefits that are achievable by fully implementing the design and planning recommended for the Microrred de la Montaña.

13 HYDRO ENERGY↗

An Introduction to the NASA GMAO Coupled Atmosphere-Ocean System - GEOS-S2S Version 3

Recently NASA's Global Modeling and Assimilation Office (GMAO) has developed a new Subseasonal to Seasonal Prediction system Version 3 (GEOS-S2S-3). This upgrade replaces the GEOS-S2S-2 which is NASA's current contribution to the North American Multi-Model Experiment seasonal prediction project (Kirtman et al., 2014). The main improvements for our S2S-3 system include 1) a higher resolution MOM5 (Griffies et al., 2005) ocean model (now 0.25o x 0.25o x 50 layers), 2) an improved atmospheric/ocean interface layer (Akella and Suarez, 2018), and 3) assimilation of a long-track satellite salinity into the ocean model (Hackert et al, 2019). Atmospheric forcing is provided by the NASA MERRA-2 reanalysis (Gelaro et al., 2017). Initialization for the ocean relies on the GMAO ocean reanalysis system which assimilates all available in situ temperature and salinity, satellite sea surface salinity, and sea level using the Local Ensemble Transform Kalman Filter (LETKF) implementation of (Penny et al., 2013) on a 5 day assimilation cycle with 20 fixed ensemble members.In this presentation, we will authenticate our new S2S-3 ocean reanalysis using standard GODAE validation metrics. For example, we will compare gridded fields of mean and standard deviation of the ocean reanalysis versus observed fields. We will show correlation/RMS of model versus observations and temperature and salinity mean profiles for the various basins and latitude bands. Basin-scale volume transports, such as the Atlantic Meridional Overturning Circulation and the Indonesian Throughflow will be validated. Equatorial ocean waves will be compared by decomposing sea level into Kelvin and Rossby components. For each of these metrics, we plan to validate the results and then compare our new S2S-3 against the current production version, S2S-2. Finally, we will compare 9-month seasonal forecasts initialized from these two systems for the tropical Pacific NINO3.4 region over the period 1981-present.

Molod, Andrea↗

Geospatial Data from the Alpine Treeline Warming Experiment (ATWE) on Niwot Ridge, Colorado, USA

This is a collection of all GPS- and computer-generated geospatial data specific to the Alpine Treeline Warming Experiment (ATWE), located on Niwot Ridge, Colorado, USA. The experiment ran between 2008 and 2016, and consisted of three sites spread across an elevation gradient. Geospatial data for all three experimental sites and cone/seed collection locations are included in this package. –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Geospatial files include cone collection, experimental site, seed trap, and other GPS location/terrain data. File types include ESRI shapefiles, ESRI grid files or Arc/Info binary grids, TIFFs (.tif), and keyhole markup language (.kml) files. Trimble-imported data include plain text files (.txt), Trimble COR (CorelDRAW) files, and Trimble SSF (Standard Storage Format) files. Microsoft Excel (.xlsx) and comma-separated values (.csv) files corresponding to the attribute tables of many files within this package are also included. A complete list of files can be found in this document in the “Data File Organization” section in the included Data User's Guide. Maps are also included in this data package for reference and use. These maps are separated into two categories, 2021 maps and legacy maps, which were made in 2010. Each 2021 map has one copy in portable network graphics (.png) format, and the other in .pdf format. All legacy maps are in .pdf format. .png image files can be opened with any compatible programs, such as Preview (Mac OS) and Photos (Windows). All GIS files were imported into geopackages (.gpkg) using QGIS, and double-checked for compatibility and data/attribute integrity using ESRI ArcGIS Pro. Note that files packaged within geopackages will open in ArcGIS Pro with “main.” preceding each file name, and an extra column named “geom” defining geometry type in the attribute table. The contents of each geospatial file remain intact, unless otherwise stated in “niwot_geospatial_data_list_07012021.pdf/.xlsx”. This list of files can be found as an .xlsx and a .pdf in this archive.As an open-source file format, files within gpkgs (TIFF, shapefiles, ESRI grid or “Arc/Info Binary”) can be read using both QGIS and ArcGIS Pro, and any other geospatial softwares. Text and .csv files can be read using TextEdit/Notepad/any simple text-editing software; .csv’s can also be opened using Microsoft Excel and R. .kml files can be opened using Google Maps or Google Earth, and Trimble files are most compatible with Trimble’s GPS Pathfinder Office software. .xlsx files can be opened using Microsoft Excel. PDFs can be opened using Adobe Acrobat Reader, and any other compatible programs. A selection of original shapefiles within this archive were generated using ArcMap with associated FGDC-standardized metadata (xml file format). We are including these original files because they contain metadata only accessible using ESRI programs at this time, and so that the relationship between shapefiles and xml files is maintained. Individual xml files can be opened (without a GIS-specific program) using TextEdit or Notepad. Since ESRI’s compatibility with FGDC metadata has changed since the generation of these files, many shapefiles will require upgrading to be compatible with ESRI’s latest versions of geospatial software. These details are also noted in the “niwot_geospatial_data_list_07012021” file.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-631: Commissioning and Comprehensive Evaluation of the ArcCHECK Cylindrical Diode Array for VMAT QA

Purpose: Commissioning and comprehensive evaluation of ArcCHECK phantom for dosimetry of VMAT QA, using 6MV photon beam with and without the flattening filter. Methods: ArcCHECK was evaluated for response dependency on linac dose rate, instantaneous dose rate, radiation field size, beam angle and couch insertion. Scatter dose characterization, consistency and symmetry of response, dosimetric accuracy of fixed aperture arcs and clinical VMAT plans were investigated. Measurements were done using TrueBeam™ STx accelerator (Console version 1.6) with a 6 MV beam with and without flattening filter. Reference dose-grids were calculated using Eclipse TPS Analytical Anisotropic Algorithm (AAA version 10.0.39). Planned doses were calculated using symmetric 2mm 3D dose grids with 4 degree angular resolution defaulted to each control point. Gamma evaluations were performed in absolute dose mode, with default normalization to maximum dose in the curved plane and a low dose threshold of 10% to restrict the analysis to clinically relevant areas. Global and local gamma indices at 3mm/3% and 2mm/2% level were computed using SNC software (version 6.0). Results: Results of gamma analysis demonstrated an overall agreement between ArcCHECK measured and TPS calculated reference doses. Field size dependency was within 0.5% of the reference. Dose-rate based dependency was well within 1% of the TPS reference and the angular dependency was ±3% of the reference, as tested for BEV angles. At the level of 3%/3mm, narrow and wide open arcs as well as clinical VMAT cases demonstrated high level of dosimetry accuracy in global gamma passing rates for both 6X and 6F beams. At the level of 2%/2mm two VMAT cases involving the narrow heavily modulated arcs demonstrated lower passing rates. Conclusion: ArcCHECK phantom with latest software and hardware upgrades is suitable for VMAT QA. For higher sensitivity of 2%/2mm gamma analysis, we intend to use it as one of the VMAT QA evaluation metrics.

07 ISOTOPE AND RADIATION SOURCES↗

Collaborative Research: Advancing Arctic Climate Projection Capability at Seasonal to Decadal Scales (Final Technical Report)

The Regional Arctic System Model (RASM) at process resolving configurations has been used to (i) advance understanding of physical processes and feedbacks involved in Arctic amplification and (ii) understand and potentially reduce uncertainty in prediction of arctic climate change at seasonal to decadal scales. RASM consists the atmosphere (Weather and Research Forecasting model, WRF), ocean (Parallel Ocean Program, POP), sea ice (CICE), land hydrology (Variable Infiltration Capacity model, VIC), river routing scheme (RVIC), marine biogeochemistry components and the coupling framework (CPL7). Its domain is pan-Arctic, with the atmosphere and land components configured on a 50-km or 25-km grid and four configurations of the ocean and sea ice components: 1/12°(~9.3km) or 1/48°(~2.4km) and 45 or 60 vertical layers. These RASM configurations have been motivated by the emerging exascale capability for high performance computing to improve model fidelity. The dynamical downscaling of reanalysis allows comparison of RASM results with observations in place and time to: (i) advance system level understanding of physical processes and coupling involved in an event, (ii) optimize model parameter space, (iii) diagnose and reduce model biases and (iv) produce realistic and consistent across all the components initial conditions for predictions and predictability studies, which are all unique capabilities not available in global Earth System Models (ESMs). An evaluation of RASM 1.0 (Cassano et al. 2017) revealed that it had a cold bias over the oceans and a warm bias over land areas due largely to cloud and radiation biases in the model, with too little cloud cover simulated over land and too much cloud cover simulated over sub-polar oceans. This study has motivated an upgrade to WRF version 3.7.1 in RASM and allowed for the inclusion of the radiative impact of convective clouds. A variety of atmospheric physics parameterizations were evaluated against observations (e.g. data from the Arctic Clouds in Summer Experiment (ACSE); Sedlar et al. 2020) to identify an optimal suite of WRF physics options in RASM. The RASM with the optimized WRF physics were used to study the impact of strong mesoscale winds over the ocean around the southern tip of Greenland (DuVivier and Cassano 2016) and their impact on oceanic convection (DuVivier et al. 2017a). Data from the PolarWinds field campaign were used to evaluate WRF boundary layer physics and resolution impacts on the simulation of a Greenland barrier wind event (DuVivier et al. 2017b). The RVIC streamflow routing model has been implemented in RASM to realistically represent high-resolution streamflow processes (Hamman et al. 2017) and to couple the land buoyancy fluxes to the ocean. The RASM-RVIC high-resolution data set of all coastal freshwater fluxes for the Arctic drainage basin and surrounding areas for 1979-2014 was published as a separate product (https://doi.org/10.5281/zenodo.293037). The fidelity of atmospheric momentum transfer to and the response of polar marine Ekman layer in RASM and Community Earth System Model (CESM) was investigated by Roberts et al. (2015). The increased frequency of oceanic flux exchange in CESM, following the RASM guidance, caused a considerable increase in the median inertial ice speed across the Southern Ocean and parts of the Arctic. A comprehensive evaluation of the RASM1.0 atmosphere-ocean-sea ice-land interface was completed by Brunke et al. (2018). RASM was also demonstrated for its capability to simulate extreme events in agreement with observations in space and time (Lee et al. submitted). In particular, the development of three open water events, known as polynyas, have been simulated north of Greenland in February of 2011, 2017 and 2018, in agreement with satellite observations for the past four decades. The optimized RASM sea ice results have been favorably evaluated against satellite observations and a subset of eleven CMIP6 models (Watts et al. submitted). In a complementary project, Jin et al. (2018) have shown that RASM with higher-resolution and new sea-ice processes contributed to lower model errors in sea-ice conditions, concentrations of nutrients and ice algae, in comparison to results from the coarse-resolution (1°) CESM. In two other complementary studies, RASM results were used (i) to explain areas of concentrated use by bowhead whales, the seasonal progression in the use, and the physical environment within those areas (Citta et al. 2015) and (ii) for a synthesis of fall bowhead whales distribution and migration in the Bering-Chukchi-Beaufort (BCB) Sea to investigate whale movements and feeding to the local ocean hydrography and currents (Citta et al. 2018). However, the multi-decadal output from the CESM Large Ensemble yielded unrealistic forcing. Instead, the shorter NCEP CFSv2 9-month forecasts were successfully tested and afforded an increased ensemble size (~30) to demonstrate gains of dynamical downscaling at sub-seasonal to intra-annual time scales. The improved model physics and coupling among RASM model components have yielded more realistic representation of the sea ice cover and consistent across all model components initial conditions. Consequently, RASM demonstrates significant gains compared to simulation of sea ice in the NCEP reanalysis. In addition, RASM 6-month ensemble forecasts yield very realistic sea ice distribution, which demonstrates both significant gains of dynamical downscaling and the continued impact of the initial conditions on forecasts out to 6 months (https://nps.edu/web/rasm/predictions). A follow up study using RASM for dynamical downscaling of the more realistic CESM initialized Decadal Prediction Large Ensemble output is currently ongoing as part of the DOE RGMA HiLAT-RASM project.

54 ENVIRONMENTAL SCIENCES↗

Permanent Magnet Synchronous Motors for Commercial Refrigeration (Final Report)

This report provides background information on various fractional-horsepower electric motor technologies used for evaporator fan applications in commercial refrigeration and summarizes data from a DOE-sponsored evaporator fan motor laboratory and field demonstration project. This report also extrapolates that data to project the potential economic and environmental benefits resulting from upgrading the current installed base of commercial refrigeration evaporator fan motors to permanent magnet synchronous (PMS) motors.Evaporator fan motors used in commercial refrigeration applications are fractional horsepower in size, responsible for moving air across the evaporator coil, and typically run at one speed. Historically, shaded-pole induction motors have been the most commonly used evaporator fan motors in commercial refrigeration equipment and beverage vending machines. These are the simplest and least expensive type of fractional-horsepower motor, with an efficiency of approximately 20%. Electronically commutated (EC) permanent magnet motors, also known as brushless DC motors, were initially commercialized in the late 1980s, and their use in commercial refrigeration applications has increased within the last 10 to 15 years because of economic incentives and regulatory requirements. State-of-the-art EC motors are approximately 66% efficient. Another induction motor type, the permanent split capacitor (PSC) motor, offers a mid-point between shaded-pole and EC motor price and efficiency levels. PSC motors are typically about 29% efficient.A permanent magnet synchronous (PMS) AC motor that can directly use grid-supplied AC current without the need to rectify to DC has recently been commercialized. This new motor exhibits a peak efficiency of 75% and has the potential to significantly reduce the energy consumption of evaporator fan motors in commercial refrigeration equipment. Laboratory evaluation of evaporator fan motor technologies was performed to quantify and compare the performance of shaded-pole, PSC, EC, and PMS evaporator fan motors in a controlled environment, so as to minimize the influence of external factors and anomalies. The laboratory evaluation included dynamometer testing of the fan motors and airflow testing of the motor/fan assemblies. It was found that the 6–12 W PMS motor exhibited a peak efficiency of 75% with a power factor of approximately 0.9 at a power output of 11 W. It was also found that a 38–50 W PMS motor exhibited a peak efficiency of 82% with a power factor of approximately 0.9 at a power output of 35 W.Airflow testing of shaded-pole, PSC, EC, and PMS motor/fan assemblies was performed using an airflow test chamber, which was designed in accordance with ANSI/AMCA Standard 210-16/ASHRAE Standard 51-16, to measure the performance of the subject motor/fan assembly and to determine the incumbent display case system impedance (AMCA 2016). A family of fan curves (static pressure vs airflow rate and electrical power input vs airflow rate) was generated for the 6–12 W PMS motor/fan assemblies with 8-inch fan blades pitched from 17 to 32 degrees. A similar set of curves was generated for the 38–50 W motors paired with 10 and 12-inch blades. Various incumbent motor/fan assemblies were also tested in the laboratory airflow test chamber and their fan curves were generated.Field evaluation of refrigerated display case evaporator fan motors was accomplished by performing side-by-side comparisons of 6–12 W PMS motors to 6–12 W shaded-pole and EC evaporator fan motors. It was found that, on average, a PMS motor consumes 79% less power and draws 82% less current than a shaded pole motor, and on average, 34% less power and 49% less current than an EC motor. In addition, the PMS motor exhibits an average power factor of approximately 0.82, which is on average 40% greater than that of existing evaporator fan motors.Two field test sites were selected to evaluate the performance of the larger 38 to 50 W PMS evaporator fan motors in walk-in cooler/freezer applications. At each supermarket, two walk-in units were selected for investigation: one walk-in dairy cooler and one walk-in freezer. A 61% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in cooler. In addition, a 48% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in freezer.The culmination of the field evaluation of fan motor technologies was a whole-store retrofit conducted at a supermarket. Pre- and post-retrofit measurement of evaporator fan motor power in medium- and low-temperature refrigerated display cases and walk-in coolers/freezers was performed. Overall for the whole-store retrofit, the current supplied to all monitored evaporator fan motors was reduced by 52%, the real power was reduced by 46% and the apparent power was reduced by 51% following the retrofit of the 262 evaporator fan motors that w

42 ENGINEERING↗

Energy and Cost Optimized Technology Options to Meet Energy Needs of Food Processors

ABSTRACT Combined cooling, heating and electric power (CCHP) distributed generation (DG) systems can provide electricity, heat, and cooling power to buildings and industrial processes directly onsite, while significantly increasing energy efficiency, security of energy supply, and grid independence. Fruit, vegetable, dairy and meat processing industries with simultaneous requirements for heat, steam, chilling and electricity, are well suited for the use of such systems to supply base-load electrical demand or as peak reducing generators with heat recovery in the forms of hot water, steam and/or chilled water. This paper documents results and analysis from a pilot project to evaluate opportunities for energy, emission, and cost for CCHP-DG and energy storage systems installed onsite at food processing facilities. It was found that a dairy processing plant purchasing 15,000 MWh of electricity will need to purchase 450 MWh with the integration of a 1.1 MW CCHP system. Here, the natural gas to be purchased increased from 190,000 MMBtu to 255,000 MMBtu given the fuel requirements of the CCHP system. CCHP systems lower emissions, however, in the Pacific Northwest the high percentage of hydro-power results in CO2 emissions from CCHP were higher than that attributed to the electric utility/regional energy mix. The value of this paper is in promoting and educating financial decision makers to seriously consider CCHP systems when building or upgrading facilities. The distributed generation aspect can reduce utility costs for industrial facilities and show non-wires solution benefits to delay or eliminate the need for upgrades to local electric transmission and distribution systems.

Makhmalbaf, Atefe↗

IRES Microgrid Energy Integration Report Version 1.0

This report presents technical information and guidance for the planned Integrated Renewable Energy System (IRES) microgrid project. This deployment of the microgrid and its associated assets was initiated in the beginning of 2022 at the Marine and Coastal Research Laboratory (MCRL) facility of Pacific Northwest National Laboratory (PNNL)-Sequim, Washington. The information in the report is organized under two main focus areas: electrical power interface, or interconnection, information of planned IRES assets; and communication and control interface, or interoperability, information of the planned IRES assets. The information will provide technical input for the development of the IRES microgrid controller technical specification, and also provide input for PNNL’s evaluation of adequacy of the electrical service infrastructure at MCRL to support the IRES project and help identify any gaps that will require facility-based upgrades. From an R&D aspect, this study and report will build on PNNL’s research and development work relating to energy storage (ES) codes and standards (C&Ss), including hybrid systems, performed on behalf of the Department of Energy (DOE) Office of Electricity (OE) ES. The current state of C&Ss for advanced technologies and their application, including microgrid-based technology is limited. For cases where formal standards issued by recognized Standards Developing Organizations do not yet exist, guidance is provided based on emerging best practices, including industry-group references that can be leveraged for microgrid technology which is in its early stages of development and use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TREAT Neutronics Analysis of Water-Loop Concept Accommodating LWR 9-rod Bundle

Abstract. Simulation of a variety of transient conditions has been successfully achieved in the Transient Reactor Test (TREAT) facility during operation between 1959 and 1994 to support characterization and safety analysis of nuclear fuels and materials. A majority of previously conducted tests were focused on supporting sodium-cooled fast reactor (SFR) designs. Experiments evolved in complexity. Simulation of thermal-hydraulic conditions expected to be encountered by fuels and materials in a reactor environment was realized in the development of TREAT sodium loop experiment vehicles. These loops accommodated up to 7-pin fuel bundles and served to simulate more closely the reactor environment while safely delivering large quantities of energy into the test specimen. Some of the immediate TREAT restart operations will be focused on testing light water reactor (LWR) accident tolerant fuels (ATF). Similar to the sodium loop objectives, a water loop concept, developed and analyzed in the 1990’s, aimed at achieving thermal-hydraulic conditions encountered in commercial power reactors. The historic water loop concept has been analyzed in the context of a reactivity insertion accident (RIA) simulation for high burnup LWR 2-pin and 3-pin fuel bundles. Findings showed sufficient energy could be deposited into the specimens for evaluation. Similar results of experimental feasibility for the water loop concept (past and present) have recently been obtained using MCNP6.1 with ENDF/B-VII.1 nuclear data libraries. The old water loop concept required only two central TREAT core grid spaces. Preparation for future experiments has resulted in a modified water loop conceptual design designated the TREAT water environment recirculating loop (TWERL). The current TWERL design requires nine TREAT core grid spaces in order to place the water recirculating pump under the TREAT core. Due to the effectiveness of water moderation, neutronics analysis shows that removal of seven additional TREAT fuel elements to facilitate the experiment will not inhibit the ability to successfully simulate a RIA for the 2-pin or 3-pin bundle. This new water loop design leaves room for accommodating a larger fuel pin bundle than previously analyzed. The 7-pin fuel bundle in a hexagonal array with similar spacing of fuel pins in a SFR fuel assembly was considered the minimum needed for one central fuel pin to encounter the most correct thermal conditions. The 9-rod fuel bundle in a square array similar in spacing to pins in a LWR fuel assembly would be considered the LWR equivalent. MCNP analysis conducted on a preliminary LWR 9-rod bundle design shows that sufficient energy deposition into the central pin can be achieved well within range to investigate fuel and cladding performance in a simulated RIA. This is achieved by surrounding the flow channel with an additional annulus of water. Findings also show that a highly significant increase in TREAT to specimen power coupling factor (PCF) within the central pin can be achieved by surrounding the experiment with one to two rings of TREAT upgrade fuel assemblies. The experiment design holds promise for the performance evaluation of PWR fuel at extremely high burnup under similar reactor environment conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Predicting the performance of system for the co-production of Fischer-Tropsch synthetic liquid and power from coal

A co-production system based on Fischer-Tropsch (FT) synthesis reactor and gas turbine was simulated and analyzed. Syngas from entrained bed coal gasification was used as feedstock of the low-temperature slurry phase Fischer-Tropsch reactor. Raw synthetic liquid produced was fractioned and upgraded to diesel, gasoline, and liquid petrol gas (LPG). Tail gas composed of unconverted syngas and FT light components was fed to the gas turbine. Supplemental fuel (NG, or refinery mine gas) might be necessary, which was dependent on gas turbine capacity expander through flow capacity, etc. FT yield information was important to the simulation of this co-production system. A correlation model based on Mobil's two step pilot plant was applied. User models that can predict product yields and cooperate with other units were embedded into Aspen plus simulation. Performance prediction of syngas fired gas turbine was the other key of this system. The increase in mass flow through the turbine affects the match between compressor and turbine operating conditions. The calculation was carried out by GS software developed by Politecnico Di Milano and Princeton University. Various cases were investigated to match the FT synthesis island, power island, and gasification island in co-production systems. Effects of CO{sub 2} removal/LPG recovery, co-firing, and CH{sub 4} content variation were studied. Simulation results indicated that more than 50% of input energy was converted to electricity and FT products. Total yield of gasoline, diesel, and LPG was 136-155 g/N m{sup 3} (CO+H{sub 2}). At coal feed of 21.9 kg/s, net electricity exported to the grid was higher than 100 MW. Total production of diesel and gasoline (and LPG) was 118,000 t (134,000 t)/year. Under the economic analysis conditions assumed in this paper the co-production system was economically feasible.

01 COAL, LIGNITE, AND PEAT↗