At least 397 records · Page 22

Fork Experiments in the Hot Cell Using Spent Fuel Rods for International Nuclear Safeguards

This work leveraged the rare availability of 25 full-length pressurized water reactor spent fuel rods and 1 irradiated mixed-oxide rod at an Oak Ridge National Laboratory hot cell. This was done to collect measurement data with two Fork detectors to assess the detectors’ capability of verifying operator declaration data and detecting partial defects in spent fuel, which are the two primary goals of international safeguards on spent nuclear fuel. The data can also be used to benchmark the ORIGEN module, which has been adopted in the International Atomic Energy Agency’s (IAEA’s)/European Atomic Energy Community’s (Euratom’s) Integrated Review and Analysis Program to predict the Fork detector count rates in real time. In this project, the authors first calibrated two Fork detectors—a standard one and a modified one—by using known strong neutron and gamma sources. Then, the authors measured all 26 fuel rods at multiple locations along the length. The fuel rods were then assembled into three arrays—2 × 2, 3 × 3, and 5 × 5—by using specially designed support grids to mimic fuel assemblies and measure the arrays with both detectors. For the 5 × 5 array, 4 and 8 fuel rods of the array were replaced in two separate cases with short stainless-steel rods to mimic two partial defect scenarios, and the arrays were measured before and after the replacements. Polyethylene blocks were used in this experiment to mimic water. The results show that the Fork detectors were able to verify operator declarations and detect partial defects in spent fuel, and the authors were the first to demonstrate this through experiments. A discovery was also made that determined the root cause of the nonlinear response to gamma dose in the ion chambers used in IAEA and Euratom’s Fork detectors. After the experiments, both detectors were retrieved from the hot cell for future use. The data collected in this project will be used in a parallel International Nuclear Safeguards Engagement Program (INSEP) project to enhance the safeguards in the Finnish spent fuel encapsulation plant, and the data will be useful to other projects in the future given the increased safeguards needs due to spent fuel transfer and disposal activities worldwide.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

InterGraph-CPS: A Graph-Theoretic Approach to Characterize Cross-Domain Cyber-Physical Interdependencies and Uncertainties in Electric Grid Systems for Improved Decision-Making in Operation and Response

Critical infrastructure systems such as the electric grid are increasingly cyber-physical; yet, despite the cyber-physical characteristics of critical infrastructure systems, the physical process system and communication/control network system are traditionally analyzed in siloes. As these systems become more cyber-physical, it is crucial that models and methods are available to assess the cyber physical system (CPS) interdependencies, characteristics, and event propagation for improved planning, operation, and response. Thus, we proposed an integrated structural and temporal CPS interdependency analysis framework, InterGraph-CPS, that provides insight into the CPS function during normal operation as well as disturbances. This integrated structural and temporal interdependency framework is uniquely designed for assessing CPSs by account for the challenges of analyzing cyber and physical data streams together due to data availability, data type, and time scale differences. By leveraging both structural (e.g., graph analysis) and temporal (e.g., data analytics) techniques, different CPS behaviors and configurations can be accounted for.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Digital Twin for an Inverter-Based Resource Power Plant: Real-time data streaming unlocks situation awareness

Here, this study presents the development and successful implementation of a digital twin specifically designed for a grid-connected IBR power plant. By integrating a reduced-order model of the IBR system and dynamically updating the grid impedance with real-time data, the digital twin effectively captures and replicates the behavior of the physical system. Its accuracy and reliability are validated through critical test scenarios, including a three-phase fault and a line-tripping event. The results confirm that the digital twin closely emulates its physical counterpart, demonstrating its strong potential for real-time analysis, system monitoring, and predictive decision making in modern power systems.

Digital twins↗

Economic Evaluation of Modernization Expenditures for Electric Utility Distribution Systems: A Guide for Utility Regulators

Cost-effectiveness evaluation of potential grid modernization solutions is integral to integrated distribution system planning (IDSP). This report synthesizes and updates prior cost-effectiveness approaches identified by the U.S. Department of Energy for grid modernization investments, incorporating multi-objective decision-making. The structure of the report follows the IDSP process, from identifying objectives and priorities to prioritizing grid solutions. The report details two methods for conducting initial cost-effectiveness screening of individual and interdependent grid components: (1) Lowest Reasonable Cost and (2) Benefit-Cost Analysis. Drawing on solutions that passed the initial cost-effectiveness screen, the utility prioritizes grid solutions based on policy objectives and priorities, regulatory compliance, operational efficiencies, and other factors to develop a portfolio of distribution solutions. The utility uses multi-objective decision-making to assess each proposed expenditure against each objective and respective metric. The utility applies a weighting factor, reflecting the priority ranking of the objective, to the total numerical “score” based on the contribution of the proposed solution to addressing each objective. Ultimately, the utility ranks each expenditure from highest to lowest priority using the final score for each solution as well as its cost. The report includes examples of emerging best practices for states and utilities and a cost-effectiveness process checklist.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Modeling for Stability Analysis

Here this document is a summary of a report prepared by the IEEE PES Task Force (TF) on Microgrid (MG) Dynamic Modeling, IEEE Power and Energy Society, Tech. Rep. PES-TR106, 2023. In this paper, the major issues and challenges in microgrid modeling for stability analysis are discussed, and a review of state-of-the-art modeling approaches and trends is presented. In the context of the IEEE 1547 standard, the document covers issues associated with component models for MG dynamic studies and simulations, including generator and grid modeling, full and average converter models, unbalanced and balanced system conditions, dynamic and static loads, protection requirements, and detailed and simplified controls considering communications delays, packet losses, and security issues. Considering the future integration of grids and MGs to form broad integrated networks, a discussion is presented of the use of phasor vis-à-vis electromagnetic transient simulation tools for MG dynamic stability studies, as well as modeling scale-up issues and MG equivalent models. Specifically white-, grey-, and black-box models, are presented. This TF paper and companion report constitute a modeling guide for R&D groups working on developments and standards of MGs with a focus on stability issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Role of Biofuels and Biomass Feedstocks for Decarbonizing the U.S. Economy by 2050 - (DECARB) Decarbonizing Energy Through Collaborative Analysis of Routes and Benefits

Utilizing biomass resources, such as cellulosic biomass and waste, can greatly contribute to decarbonization efforts in the U.S. economy. The U.S. bioenergy sector includes corn ethanol production, biodiesel, renewable diesel production, and the utilization of biomass wastes for electricity generation being the primary applications. Within the electricity sector, biopower can play a crucial role as a stable low-carbon resource. Enhancing the electricity mix's diversity could enhance grid reliability. If the issues regarding hot gas cleanup can be resolved, flexible biopower resources like biomass gasification facilities could complement the integration of variable renewable energy sources due to their quick ramp-up and ramp-down times. The criticality of bioenergy deployment lies in its ability to decarbonize hard-to-electrify sectors, such as aviation, where alternative decarbonization options may not be viable in the short term. Moreover, bioenergy has the potential to be converted into process heating, building materials, and plastics, which are not considered in this study. A set of pathways was carefully chosen to represent viable options for converting ample herbaceous and woody cellulosic feedstocks into fuels, chemicals, and electricity in this study. In conclusion, biomass pathways provide flexibility by generating various types of bioenergy and bioproducts, including electricity, hydrogen, liquid fuels, biochemicals, and bioplastics. When paired with carbon dioxide capture and storage (CCS), specific bioenergy approaches can effectively extract carbon dioxide from the atmosphere, thus providing an effective decarbonization option for the transportation sector.

09 BIOMASS FUELS↗

Evaluating Direct and Indirect Influence on EV Charging Stations Across the US

The adoption of new technology for electric vehicles (EV) and mobility applications can bring underappreciated vulnerabilities to the power grid. One area of potential fraud and adversarial influence is through the business ecosystem of startups that own and deploy EV technology. Yet, there are no models or analyses that map the network of organizations and people that have direct and indirect influence over technologies currently deployed in the grid. To fill this gap, we develop a multilayer network model to measure direct and indirect influence on EV charging stations. First, we create and adversarial socio-technical network (ASTN) model via a data fusion pipeline for different US regions of interest (ROI). Then, we develop an integrated ASTN for Chicago, Los Angeles, New York, and Philadelphia. We rank EV charging companies direct influence within each geographic region as well as indirect influence via social network analysis. While some companies have strong direct and indirect influence (i.e., ChargePoint) others show a mismatch between their influence over charging stations and their position within the social network. For example, Tesla has strong direct influence on stations and weak indirect influence over competitors. In contrast, 7Charge has weak direct influence over stations, but strong indirect influence over competitors.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Arbitrage: Comparison of Options for use with LWR Nuclear Power Plants

Arbitrage is the opportunistic buying and selling of a commodity during local pricing valleys and peaks respectively to maximize economic value. This report evaluates options for energy arbitrage integrated with existing light water reactor (LWR) nuclear power plants (NPPs) where nuclear energy could be stored in a variety of forms and later recovered to generate electrical power during periods when grid electricity demand and pricing are high. The forms of energy storage examined in this report include the potential value of batteries, hydrogen, and thermal energy storage for coupling with nuclear power. Various large demand response options are also analyzed, including the production of liquid nitrogen via air separation and liquefaction, liquefaction of hydrogen, compressed hydrogen, and the cryogenic capture of CO2. Demand response refers to dispatchable loads that can cycle up or down depending on-grid electricity demand to aid in balancing the grid. Large demand response options could dispatch to aid nuclear power stations in avoiding power turndowns by providing an alternate disposition for electrical energy by producing marketable products (e.g., liquid nitrogen, hydrogen, or captured CO2). Static conditions were chosen and analyzed in this report for each option. Dynamic operation or optimization of energy arbitrage or demand response are out of scope for this report. The analysis is based on storage systems with discharge capacities of 500 MW for which various durations of storage and costs of charging (electricity cost) are examined. While the value of thermal energy to an industrial user for flexible plant operations has been previously proven as a business case, this report evaluates costs of hydrogen energy storage and leading thermal energy storage options, and large demand response loads that could be integrated with LWRs in comparison to utility-scale battery storage for use of off-peak nuclear energy. Compilation of this information will be used by the Idaho National Laboratory (INL) RAVEN/HERON systems integration and economics tool to evaluate thermal energy dispatch to industrial users. Relative ranking of energy storage options was done using a levelized cost of storage (LCOS) metric which calculates a rough breakeven cost for the system, taking into account the capital and operating costs as well as the revenue from arbitrage. Table ES1 below shows the LCOS for each of the energy storage options considered. First, in the table, lithium iron (Fe) phosphate batteries are listed as the base case for comparison against the other options. Next is hydrogen storage where most of the hydrogen analyses assumed the hydrogen to be produced using solid oxide electrolytic cell (SOEC) high temperature steam electrolysis (HTSE). The others used existing models of polymer electrolyte membrane (PEM) low temperature electrolysis to produce hydrogen. HTSE performance parameters and costs were taken from existing INL models. Various means were assumed to convert the hydrogen to electricity, including PEM fuel cells (FCs) and a gas turbine mixed in a 30 vol% mixture with natural gas. Physical storage (pressure vessels) and geological storage (natural underground features) were used to store the hydrogen as noted. Geological storage is more economical, but the locations are limited because of the requirement for pre-existing geological formations that will support storage. Thermal energy storage (TES) options were also analyzed including electro-thermal energy storage (ETES) and four different liquid sensible heat TES storage media as noted (Hitec, Hitec XL, Therminol-66, and Dowtherm A). The ETES process considered was modified using existing public documentation on an Echogen process and uses a separate supercritical CO2 charge and discharge cycle with sand as the heat storage media.

25 ENERGY STORAGE↗

Synchronization in electric power networks with inherent heterogeneity up to 100% inverter-based renewable generation

The synchronized operation of power generators is the foundation of electric power network stability and a key to the prevention of undesired power outages and blackouts. Here, we derive the conditions that guarantee synchronization in power networks with inherent generator heterogeneity when subjected to small perturbations, and perform a parametric sensitivity analysis to understand synchronization with varied types of generators. As inverter-based resources, which are the primary interfacing technology for many renewable sources of energy, have supplanted synchronous generators in ever growing numbers, the center of attention on associated integration challenges have resided primarily on the role of declining system inertia. Our results instead highlight the critical role of generator damping in achieving a stable state of synchronization. Additionally, we report the feasibility of operating interconnected electric grids with up to 100% power contribution from inverter-based renewable generation technologies. Our study has important implications as it sets the basis for the development of advanced control architectures and grid optimization methods that ensure synchronization and further pave the path towards the decarbonization of the electric power sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modelling and analysis of nuclear reactor system coupled with a liquid metal battery

Traditionally, nuclear power plants in the U.S. provide baseload power to the power grid because they have less flexibility for ramping their output power than natural gas peaking plants. However, achieving climate goals to reduce the consumption of fossil‐based natural gas places pressure on nuclear power plants and other power generators to ramp up their power output to balance grid generation with demand. This paper presents the modelling and performance analysis of a nuclear reactor system (NRS) coupled to a liquid‐metal battery (LMB) to improve its dynamic response and enable its black start capability. The NRS and LMB thermal behaviour are modelled in Dymola, while the electrical dynamics of the LMB and power grid are modelled in RTDS‐RSCAD. Both simulation platforms are coupled and share their thermal and electrical data using a Transmission Control Protocol/Internet Protocol (TCP/IP) communication protocol. The dynamic performance of the NRS‐LMB integration is tested on the IEEE 9 bus, which demonstrates its ability to respond and provide frequency and voltage regulation. The black start capability of the NRS‐LMB is also evaluated by simulating a grid outage and using the LMB to supply the auxiliary loads required to bring the NRS back online as soon as possible. The results show that coupling an NRS to an LMB improves the system dynamic performance and enables it to black start after being disconnected from the grid for several days.

25 ENERGY STORAGE↗

Supporting U.S. National Security Through Cybersecurity Partnerships

At NLR, we're studying energy evolutions and threats to understand the challenges they pose and uncover ways to leverage grid advancements to achieve more secure, defensible, and reliable systems. Our integrated research approach bridges the gap between cyber threats and real-world consequences to deliver actionable solutions that reduce vulnerabilities and help strengthen U.S. national security.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Completing the Circuit: Workforce Development for Advanced Building Construction and Grid-Interactive Efficient Buildings

This paper will present key findings from a future-oriented qualitative study investigating likely futures for the next 5-10 years in the architecture, engineering, construction, and operations industry. This research offers an original contribution to the buildings industry by articulating an actionable framework to more effectively build connections between built environment fields. Whereas the ideal of interdisciplinary, research driven practice underlies the approach to pedagogy at many schools of architecture, innovation in the profession, such as the integrated design process, has been limited. This project applies Legitimation Code Theory (LCT) to the analysis of data gathered from interviews and a review of industry reports.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Resilient, Self-Powered, Fuel Flexible, High Efficiency Heating System (Final Report)

The Grid Independent High Efficiency System (GIHES) delivers a heating system that operates free from the power grid and provides ultra-low emissions and high efficiency heating for residential and commercial buildings. The project demonstrated two weeks of continuous grid independent operation of a storage water heater equipped with a powered damper. The Thermoelectric Generator (TEG) integrated GIHES technology revolutionizes heating systems to provide grid resilient hot water production, while delivering significant value to the end user by eliminating impacts of power interruption and enhancing comfort, convenience and productivity. The system maximizes the thermal-to-electric conversion efficiency by optimizing location and orientation of the TEGs and durability while lowering system costs. The TEGs generate enough power to charge a battery and run the storage water heater unit with a powered damper uninterrupted by providing the required parasitic electrical power for start-up, shutdown and during idling. Several TEGs were analytically and experimentally evaluated based on the size, surface area and the power being generated before designing and fabricating a complete multi-TEG assembly for integration with the water heater. The GIHES technology can be extended to boilers, furnaces and tankless water heaters and integrated with heat pump to further increase the overall equipment efficiency. The technology has the potential to reduce the amount of dispatch power and peak power plant operation. An advanced burner was designed, developed and 3D printed for fuel flexible operation. The burner was designed to enable tighter integration with TEGs for potentially higher TEG output, should this be necessary. A bench-scale test rig to perform testing of a 200,000 Btu/h burner and capable of handling up to 10% H2 (by volume) was setup at GTI’s laboratory with appropriate safety and controls to ensure smooth and safe operation. Testing of the 3D burner showed < 5 ppm NOx emissions can be achieved for the entire firing range and with different levels of hydrogen blends with natural gas. The burner will enable a more integrated TEG-burner module design for improved system performance, should this be required in the future. Techno-economic analysis (TEA) of the TEG integrated with the water heaters was performed. The testing data and the power output were used to develop the TEA. The analysis for the storage unit with damper showed that the TEG integrated system costs $95. This is much lower than a one-time charge needed to wire and install dedicated power. Discussions with TEG manufacturers and OEM’s will provide more detailed information and methods to further lower these costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decentralized Control of Cascaded H-Bridge Inverters for Medium-Voltage Grid Integration: Preprint

This paper introduces a fully decentralized control strategy that allows for individualized active and reactive power control of H-bridge inverters connected in series. After formulating a model of the system power flows, we outline a communications-free approach where each inverter can act on independent commands. Inverter-level feedback is accomplished locally via a measurement of current flowing through the stack. A key feature is the lack of any centralized control routines or phase-locked loop. In this framework, the reactive power control loops achieve voltage synchronization among the converters and the grid, and the active power control loops modulate the terminal voltage amplitudes that influence power delivery. Furthermore, pole placement via state feedback is used to ensure stability of voltage synchronization while also enabling tracking of bidirectional power commands. Simulations are presented to validate the proposed approach.

communication-free modular converter control↗

Modeling Framework for the Assessment of a Sustainable Hydrogen Production and Supply Chain Network in California

The cost-effective and sustainable deployment of hydrogen supply and demand networks, especially in large economic regions like California, can be challenging considering the spatial-temporal availability and variability of the different actors across the network such as production processes, distribution modes, and end-users. In this presentation, we will provide an overview and demonstration of a modeling framework used to assess the environmental, economic, and human health impacts of plausible hydrogen production and supply chain networks in California. Scenarios focus on green hydrogen production pathways using water electrolysis and biomass gasification. End-use applications included in the model are transit, medium and heavy-duty trucking, port authorities, and power and aviation companies that currently consume natural gas, diesel, and aviation fuel for their day-to-day operation. Representative locations for hydrogen production and end-use are based on recent projections of the hydrogen economy in California. All mass and energy flows, as well as estimated emissions, are based on H2A process model designs and projections of technology performance, literature review, and LBNL process, economic and life cycle modeling, and not on company data for the sake of this presentation. Human health impacts are included following methodologies developed for the University of California Irvine HyDeal project. Life cycle phases associated with hydrogen production include feedstock preparation (water and biomass), energy production and consumption (renewable, grid, and combination of renewable and grid electricity), maintenance (chemical utilization in electrolysis and natural gas combustion in gasification), carbon sequestration, hydrogen storage (compression and liquefaction), and distribution (truck and pipeline). We apply the framework utilizing California specific emission factors, financial data, and human health damages and explore the impact of network characteristics on results. Example variations include: the inclusion of policy incentives or not, different representations of the electricity grid and source, electrolysis versus gasification versus combinations of both for production, liquefaction versus compression based on producer capacity cutoffs, transportation truck versus pipeline based on existing infrastructure, and ultimate end use. Comparison of these different scenarios can help inform future projects by demonstrating the trade-offs among environmental, economic, and human health impacts. This model, automated in R, is a starting platform upon which new analysis, modeling capabilities, locations, and emission factors can be rapidly tested and integrated.

Zaki, Mohammed Tamim↗

Advanced-Research-on-Integrated-Energy-Systems-Based Analysis to Support Resilient System Upgrades: Energy to Communities Energyshed In-Depth Partnership with Molokai, Hawaii

The Molokai, Hawaii, Energy to Communities (E2C) Energyshed project represents a collaborative effort between the National Laboratory of the Rockies, Shake Energy Collaborative, the Molokai Clean Energy Hui, Sustainable Molokai, and Ho'ahu Energy Cooperative Molokai to advance Molokai's Community Energy Resilience Action Plan (CERAP). Supported by Hawaiian Electric Company and the Hawaii State Energy Office, the initiative aims to develop a community-defined portfolio of renewable energy solutions that enhance energy resilience while aligning with the Hawaiian Electric Integrated Grid Plan (IGP) and Molokai's energy goals. Phase 1 focused on technical analyses and community engagement to co-design feasible energy scenarios. Challenges such as grid upgrades, storage sizing, and inverter ride-through standards were addressed to align technical and operational requirements with community preferences. The project equips Molokai with actionable data and insights to implement energy initiatives while ensuring resilient and culturally informed solutions. Future efforts aim to finalize project designs, secure interconnection agreements, and deploy energy projects that reflect community priorities and technical feasibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Self-powered Heating: Efficiency Analysis

Conventional fuel-fired heating devices such as furnaces, boilers, and water heaters have fuel efficiency less than 100% on the basis of higher heating value. They also require electricity from the electric grid to power parasitic loads such as blowers, pumps, fans, and ignitors. The primary energy efficiency of the device accounts for both fuel used on-site and primary energy used off-site to produce electric power used by the device. This work compares conventional fuel-fired heating devices to two types of self-powered devices. A self-powered device (SPD) integrates a power cycle onboard to eliminate consumption of grid electricity. We assume that all heat rejected by the onboard power cycle is added to the process fluid, so that, compared with a conventional device, the same amount of heat is provided to the process fluid and the same amount of fuel is consumed, but grid electricity consumption is eliminated. The first SPD type is the basic one: exactly the electricity required is generated. The second type considered is the SPD with heat pump (SPD-HP), in which the power cycle generates more electricity than needed for parasitic loads, and the excess electricity is used to power a heat pump. The heat pump extracts additional heat from the ambient to boost efficiency. Both SPD and SPD-HP self-consume all the generated electricity, in contrast to combined heat and power (CHP) systems that export electricity. In this work, equations are derived to express the efficiency of three classes of heating devices: conventional (consuming grid electricity), self-powered (consuming no grid electricity), and self-powered with heat pump. The efficiency of each is derived as a function of up to six factors: (1) the fraction of combustion heat captured, (2) the rate of parasitic power consumption, (3) the fraction of electric energy dissipated as useful heat, (4) the power cycle conversion efficiency, (5) the grid efficiency, when applicable, and (6) the heat pump COP, when applicable. Scenarios are identified in which it is possible to achieve efficiency greater than 100% on a higher heating value basis. Plausible configurations using existing technology options are outlined.

Gluesenkamp, Kyle↗