Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid analysis and integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Application of CART3D to Complex Propulsion-Airframe Integration with Vehicle Sketch Pad

Vehicle Sketch Pad (VSP) is an easy-to-use modeler used to generate aircraft geometries for use in conceptual design and analysis. It has been used in the past to generate metageometries for aerodynamic analyses ranging from handbook methods to Navier-Stokes computational fluid dynamics (CFD). As desirable as it is to bring high order analyses, such as CFD, into the conceptual design process, this has been difficult and time consuming in practice due to the manual nature of both surface and volume grid generation. Over the last couple of years, VSP has had a major upgrade of its surface triangulation and export capability. This has enhanced its ability to work with Cart3D, an inviscid, three dimensional fluid flow toolset. The combination of VSP and Cart3D allows performing inviscid CFD on complex geometries with relatively high productivity. This paper will illustrate the use of VSP with Cart3D through an example case of a complex propulsion-airframe integration (PAI) of an over-wing nacelle (OWN) airliner configuration.

Hahn, Andrew S.↗

Grid-Integrated Production of Fischer-Tropsch Synfuels from Nuclear Power

Idaho National Laboratory (INL) investigates the relative economic profitability of an integrated energy system (IES) coupling an NPP with a synfuel production process at selected case study locations across the United States. In the synfuel IES, a high-temperature steam electrolysis (HTSE) plant is thermally and electrically coupled with an NPP to produce zero-carbon hydrogen. The synthetic fuel is produced from this H 2 combined with a CO 2 supply using the reverse water gas shift process followed by the Fischer-Tropsch (FT) reaction. This analysis considers a system in which the CO 2 is sourced from regional CO 2 emitters via the construction and operation of pipeline-based CO 2 supply networks. Locating the FT plant at the same site as the NPP and HTSE plants enables the NPP to provide zero-carbon heat and power to the HTSE plant and zero-carbon power to the FT plant as well as avoid the requirement for long-distance H 2 product transport from the HTSE plant to the FT plant. Hydrogen storage is used to enable the NPP to dispatch power to the electrical grid (instead of the HTSE plant) when grid demand increases, thus enabling the FT plant to continue to operate in a steady-state production mode. The ability to cease hydrogen production for several hours within each day enables the NPP to provide power to the grid to balance the electricity market during peak periods and maximize revenues for the nuclear synfuel IES. The FT process design considered has a 99% carbon conversion efficiency. The use of nuclear energy and nuclear energy-derived hydrogen enables synfuel production to achieve this high level of carbon utilization. Additionally, the life-cycle carbon emissions of the nuclear-based synfuel production process are very low, with WTW emissions of approximately 25 gCO 2 e/MJ, including steam credits (generated from FT process excess heat), and approximately 7 gCO 2 e/MJ, if steam credits are excluded. This compares favorably with the WTW emissions of 90.5 gCO 2 e/MJ for a compression-ignition, direct injection (CIDI) vehicle with a fuel economy of 31.6 miles per gallon gasoline equivalent (MPGGE), using low-sulfur diesel produced using conventional petroleum production and refining processes. Several NPPs in various regions of the U.S. are considered as case study analyses. Supply locations and transportation via pipeline of the CO 2 feedstock to the NPP site are analyzed through the National Energy Technology Laboratory (NETL) CO 2 Transport Cost model. The team finds that the amount of CO 2 generated by different sectors is sufficient for the synfuel production process at all locations considered. The CO 2 transportation costs are functions of the distance of the source to the NPP location, the CO 2 capture cost at the source, and the quantity of CO 2 transported. Historical electricity prices for the NPP case study locations are collected and analyzed. Monthly average prices, price range, and duration of negative-price periods vary among these locations. For each location, an auto-regressive moving average (ARMA) model is trained on historical electricity price data. ARMA validation is done to ensure the synthetic price distributions represent one of historical prices with high fidelity. Synthetic time series from these ARMA models are used in a coupled dispatch and system optimization in the Holistic Energy Resource Optimization Network (HERON) to compute the differential net present value (NPV) of the IES. The team finds that this econometric is positive, ranging from $14M–1.3bn (2020) depending on the location. The optimal synfuel IES configuration to obtain this increase in NPV often maximizes the size of the synfuel production process with regards to the size of the NPP. However, the team shows that the NPP still plays a stabilizing role for the grid: In periods of high prices and high loads, more electricity from the NPP is sent to the grid. A high variability of electricity prices and extreme maximum prices tend to drive up electricity production. While it requires significant investment, the synfuel IES could increase the economic profitability for the existing fleet of LWRs across the country while still maintaining the grid stabilizer role of NPPs. During its lifetime, the main costs for the nuclear synfuel IES are the carbon feedstock transportation costs, followed by the capital expenses (CAPEX) and operation and maintenance (O&M) costs while the revenue comes first from the IRA H 2 production tax credit (PTC) and then from the sales of synfuel products. The profitability of the synfuel IES is most sensitive to the value of the hydrogen PTC and the synfuel products as well as the cost of the carbon feedstock, highlighting the importance of governmental incentives regarding hydrogen, carbon emissions, and synfuel in driving the deployment of future nuclear synfuel IESs.

08 HYDROGEN↗

Analysis of implicit second-order upwind-biased stencils

Truncation error and stability properties of several implicit upwind schemes for the two-dimensional Euler equations are examined. The schemes use linear data reconstruction methods to achieve second-order flux integrations where the implicit Jacobian operators are first order. The stability properties of the schemes are examined by a Von Neumann analysis of the linearized, constant-coefficient Euler equations. The choice of the data reconstruction method used to evaluate the flux integral has a dramatic effect on the convergence properties of the implicit solution method. In particular, the typical one-dimensional data reconstruction methods used with structured grids exhibit poor convergence properties compared to the unstructured grid method considered. Of the schemes examined, the one with the superior convergence properties is well-suited for both unstructured and structured grids, which has important implications for the design of implicit methods.

Roberts, Thomas W.↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Integrated multimodel analysis reveals achievable pathways toward reliable, 100% renewable electricity for Los Angeles

Climate change has prompted many communities to set targets for carbon-free power supplies, but they often lack data-driven strategies to achieve them. We present a comprehensive analysis of an entirely renewable electric power system that can maintain operating reliability and resource adequacy using detailed models of the city of Los Angeles power grid. In consultation with the operating utility, the Los Angeles Department of Water and Power (LADWP), and the local community, we develop four supply scenarios across three demand projections to analyze which types of infrastructure and operational changes would achieve reliable electricity at least cost. We find that a reliable, 100%-renewable power system yielding more than $1 billion annually in health and climate co-benefits is achievable. Solar can supply most future energy needs, while combustion turbines that use renewable, storable carbon-neutral fuels are key to maintaining reliability. This study provides a replicable methodology that other jurisdictions globally can follow.

14 SOLAR ENERGY↗

CHARGE-MAP: An integrated framework to study the multicriteria EV charging infrastructure expansion problem

The widespread adoption of electric vehicles (EVs) in recent years has necessitated the development of effective charging infrastructures. However, charging infrastructure expansion is a multifaceted problem that requires careful consideration of the existing infrastructure, spatiotemporal distribution of charging demands, power-grid capacity, and budget constraints. Here, to approach this complex problem, we present CHARGE-MAP, a data-driven simulation-optimization framework, focused on ensuring meaningful charging experience for individual EV owners. CHARGE-MAP integrates three modules: an agent-based simulation module that estimates spatiotemporal distribution of charging demands by modeling EV adopter mobility and charging behavior; an optimization module that determines optimal new charging station/charger locations and capacities, while minimizing expected detour distances and wait-times with a limited number of new stations; and a power module that determines how to connect the stations to the power grid while maintaining its stability. Using the state of Virginia (consisting of 95 counties and 38 independent cities) as a case study, our results show that CHARGE-MAP can meet the demand of ~198,600 predicted EVs with 1,305 new public charging stations and 2,164 new chargers. It reduces average detour distances for charging by 66% and wait-times at stations by 72% compared to the existing infrastructure. Furthermore, transformer capacity requirement analysis reveals that only 1.8% of residential transformers require upgrades, while over 80% of commercial charging locations can be supported with modest transformer infrastructure (25 to 50 kVA). This indicates that targeted investments can facilitate cost-effective EV integration. Consequently, CHARGE-MAP provides policymakers and urban planners with crucial data-driven insights for effective EV charging infrastructure expansion. Sign up for PNAS alerts.

charging infrastructure↗

Techno-Economic Assessment of Data Center Load Demand Powered by Small Modular Reactors and Distributed Energy Resources

The rapid increase in data center energy demand, driven by AI and large-scale data processing, poses significant challenges to global energy infrastructure. Data centers require substantial and reliable energy for continuous operations and high-performance computing. Current electrical grids face issues such as transmission bottlenecks and aging infrastructure, making it difficult to meet these demands. Integrating inverter-based-resources (IBRs) like solar and wind presents both opportunities and challenges due to their intermittent nature. Small Modular Reactors (SMRs) offer a promising solution with their enhanced safety, modularity, reliability, and scalability, providing consistent base load power ideal for data center operations. This study presents a comprehensive techno-economic assessment of powering data center load demand using a combination of SMRs and IBRs with grid-connected and islanded mode. This study utilized Idaho National Laboratory’s (INL) HPC data center hourly load profiles and Xendee microgrid optimization platform to conduct the analysis. In this configuration, SMRs serves as the primary base load power source, consistently providing a steady supply of electricity necessary to meet the minimum load demand of the data center with support from the IBRs. Key performance indicators such as Levelized Cost of Electricity (LCOE), Net Present Value (NPV) has been calculated to assess the economic feasibility. The findings from this research will underscore the strategic benefits of integrating SMR plant with DERs – particularly for critical infrastructure load such as data centers.

14 - SOLAR ENERGY↗

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

State Requirements for Electric Distribution System Planning

Utilities have conducted distribution planning since they first began building and operating electricity systems. But filing these plans for regulatory and stakeholder review is a relatively recent phenomenon. This report summarizes legislative and regulatory requirements for regulated electric utilities to file some type of distribution system plan in 20 U.S. jurisdictions. Some plans focus on expedited cost recovery for certain types of distribution system improvements; other plans focus on investments for grid modernization or distributed energy resources. Increasingly, states are adopting requirements for Integrated Distribution Plans. Such plans provide holistic grid investment strategies that address state and local policies and increasing complexity at the grid edge. The report covers the following topics for distribution system plans, highlighting advanced practices: -State goals and objectives -Procedural requirements -Forecasting loads and distributed energy resources -Hosting capacity analysis -Baseline information requirements -Grid modernization strategy -Grid needs assessment -Non-wires solutions -Reliability and resilience analyses -Stakeholder engagement -Equity -Pilots -Coordination with other planning processes The report includes links to legislation; regulatory requirements, proceedings, and orders; and filed utility plans. The U.S. Department of Energy’s Office of Electricity provided funding support.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DASSH-F: Subchannel Based Thermal Analysis

The DASSH thermal analysis code is designed to rapidly allow a reactor design engineer to obtain flow rates requirements that satisfy peak temperature constraints in the domain. The advantage of using DASSH over a hand calculation is that it has a more rigorous treatment of the pin power distribution and coolant heat transfer within an assembly and between assemblies. The advantage of using DASSH over a conventional 3D subchannel code or a computational fluid dynamics code (CFD) is that it can obtain the desired solution in a matter of minutes in serial with minor computer memory needs. The DASSH methodology is virtually identical to SUPERENERGY-2 with additional functionalities taken from follow on work to SUPERENERGY-2 done at ANL in the 1980s. DASSH today is an integral component of the Argonne Fast Reactor analysis suite for reactor design work. DASSH obtains the power distribution from a coupled neutron-gamma heating calculation in GAMSOR (including DIF3D) at each time point of a companion fuel cycle analysis calculation with REBUS. The domain in DASSH assumes a hexagonal grid typical for fast reactors with much of the geometry information taken from the DIF3D model. DASSH assumes the assemblies that are loaded into each grid position are ducted to control the coolant flow. Considerable detail is given on the subchannel formulation of DASSH in this document. Much of the formulation and design of the code builds upon research done by previous authors with little new investigation. Thus the decisions made in developing the subchannel model used in DASSH have their origins over 50 years ago. Much of the heat transfer methodology in DASSH is built upon correlations for both the coolant mixing and heat transfer coefficients for pins and ducts. DASSH is thus not a rigorous treatment of a given problem, but a rapid assessment of the temperature field that has known limitations with respect to an experimental measurement or CFD calculation. The DASSH input and output are detailed along with usage of the software. The DASSH output provides tables of evaluated material properties and key coolant and pin temperature results. DASSH can create Python scripts that generate domain summary pictures. DASSH can also generate assembly temperature maps and VTK output files which allow the DASSH solution to be visualized. As the primary purpose of the DASSH software is to compute the coolant and fuel pin temperature distribution for a given model of a reactor, much of the output focus is giving the user quick summary tables needed to assess the performance of a given orifice flow specification. The present version of DASSH has a crude orifice search capability and an efficient orifice flow search capability. The flow search tries to meet user specified constraints for 1) peak 2-sigma clad midwall temperature, 2) peak coolant temperature, and 3) desired bulk outlet temperature. There are many development shortcomings in DASSH detailed in this document, but this version is functional for modern analysis needs. This document serves as the manual for the Fortran based DASSH software that was developed to replace the Python version of DASSH developed as part of the VTR program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DASSH-F: Subchannel Based Thermal Analysis

The DASSH thermal analysis code is designed to rapidly allow a reactor design engineer to obtain flow rates requirements that satisfy peak temperature constraints in the domain. The advantage of using DASSH over a hand calculation is that it has a more rigorous treatment of the pin power distribution and coolant heat transfer within an assembly and between assemblies. The advantage of using DASSH over a conventional 3D subchannel code or a computational fluid dynamics code (CFD) is that it can obtain the desired solution in a matter of minutes in serial with minor computer memory needs. The DASSH methodology for pin lattice models is virtually identical to SUPERENERGY-2 with additional functionalities taken from follow on work to SUPERENERGY-2 done at ANL in the 1980s. DASSH today is an integral component of the Argonne Fast Reactor analysis suite for reactor design work. DASSH obtains the power distribution from a coupled neutron-gamma heating calculation in GAMSOR (including DIF3D) at each time point of a companion fuel cycle analysis calculation with REBUS. The domain in DASSH assumes a hexagonal grid typical for fast reactors with much of the geometry information taken from the DIF3D model. DASSH assumes the assemblies that are loaded into each grid position are ducted to control the coolant flow. The user can alternatively provide their own geometry and power profile instead of inheriting it from DIF3D. Considerable detail is given on the subchannel formulation of DASSH in this document. Much of the formulation and design of the code builds upon research done by previous authors with little new investigation. Thus the decisions made in developing the subchannel model used in DASSH have their origins over 50 years ago. Much of the heat transfer methodology in DASSH is built upon correlations for both the coolant mixing and heat transfer coefficients for pins and ducts. DASSH is thus not a rigorous treatment of a given problem, but a rapid assessment of the temperature field that has known limitations with respect to an experimental measurement or CFD calculation. The DASSH input and output are detailed along with usage of the software. The DASSH output provides tables of evaluated material properties and key coolant and pin temperature results. DASSH can create Python scripts that generate domain summary pictures. DASSH can also generate assembly temperature maps and VTK output files which allow the DASSH solution to be visualized. As the primary purpose of the DASSH software is to compute the coolant and fuel pin temperature distribution for a given model of a reactor, much of the output focus is giving the user quick summary tables needed to assess the performance of a given orifice flow specification. The present version of DASSH has a crude orifice search capability and a sufficient orifice flow search capability. The flow search tries to meet user specified constraints for 1) peak 2-sigma clad temperature, 2) peak coolant temperature, and 3) desired bulk outlet temperature. This document serves as the manual for the Fortran based DASSH software that was developed to replace the Python version of DASSH developed as part of the VTR program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Power Electronics and Electric Machines

The advanced power electronics and electric machines (APEEM) research group at the National Renewable Energy Laboratory (NREL) has developed world-class experimental and modeling capabilities for designing and evaluating efficient and reliable power electronics and electric machines thermal management systems. They also design, fabricate and characterize advanced power electronics packaging, and are developing state-of-health monitoring techniques. These researchers deliver safe, reliable, high performing, power-dense components that allow seamless integration between renewable energy sources, electric transportation, and the grid, helping to make widespread electric vehicle (EV) adoption and greenhouse gas emissions reduction more feasible. This document outlines the group's major capabilities in the areas of power electronics; module development and characterization; thermal modeling and management; thermomechanical reliability analysis of devices, modules, inverters/converters, and electric machines; physics-of-failure-based reliability analysis; and microelectronics. It also overviews the group's state-of-the-art equipment for fluid-based thermal management; thermal measurement & characterization; thermomechanical reliability analysis; micro- and power electronics measurement & characterization; and prototype fabrication, as well as the group's world-class modeling and simulation capabilities.

advanced gate drivers↗

Novel GLIDES Technology for Grid Resiliency. Final Report

The transformative Ground Level Integrated Diverse Energy Storage (GLIDES) technology was invented and had early stage success demonstrated at Oak Ridge National Laboratory (ORNL) in 2013–2017. The first proof-of-concept demonstration prototype of GLIDES has been successfully developed. In May 2016, this unique technology was a featured story in the ASHRAE newsletter.1 A detailed thermophysical analysis of this system has also been already published.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A multiblock/multigrid Euler analysis of a propfan transport with wing-mounted nacelles, including slipstream effects

A multiblock/multigrid computation of the inviscid flow over a wing-mounted propfan transport with propwash is presented. An explicit multistage scheme drives the integral Euler equations to a steady state solution, while an actuator disk approximates the slipstream effects of the propfan blades. Practical applications of detailed surface gridding, multiple block field grids and multigrid convergence acceleration are demonstrated.

Nishida, Brian A.↗

Idaho Falls Power Black Start Field Demonstration (Preliminary Outcomes Paper)

This April 2021 field demonstration builds upon a 2017 field demonstration in which it was determined IFP’s HPPs, on their own, can support islanded black start and operation up to 2.5 MW loading. Modeling and hardware-in-the-loop testing was used in the intervening period to design an energy storage solution, specifically using ultracapacitors, to reduce likelihood of generators tripping during the field demonstration. Overall, the 2021 field demonstration tested three different options for meeting IFP’s requirements: innovating the hydropower controls, synchronizing multiple HPPs on the system, and integrating an ultracapacitor energy storage system. This report documents the testing performed. Follow-on analysis will provide additional insights, for example, including a complete table of comparative results between the tests and scenarios. The analysis will also propose a refined design for an energy storage system to meet IFP’s grid islanded needs.

13 HYDRO ENERGY↗

Multidisciplinary design optimization using multiobjective formulation techniques

This report addresses the development of a multidisciplinary optimization procedure using an efficient semi-analytical sensitivity analysis technique and multilevel decomposition for the design of aerospace vehicles. A semi-analytical sensitivity analysis procedure is developed for calculating computational grid sensitivities and aerodynamic design sensitivities. Accuracy and efficiency of the sensitivity analysis procedure is established through comparison of the results with those obtained using a finite difference technique. The developed sensitivity analysis technique are then used within a multidisciplinary optimization procedure for designing aerospace vehicles. The optimization problem, with the integration of aerodynamics and structures, is decomposed into two levels. Optimization is performed for improved aerodynamic performance at the first level and improved structural performance at the second level. Aerodynamic analysis is performed by solving the three-dimensional parabolized Navier Stokes equations. A nonlinear programming technique and an approximate analysis procedure are used for optimization. The proceduredeveloped is applied to design the wing of a high speed aircraft. Results obtained show significant improvements in the aircraft aerodynamic and structural performance when compared to a reference or baseline configuration. The use of the semi-analytical sensitivity technique provides significant computational savings.

Chattopadhyay, Aditi↗

Derivation of a New Smoke Emissions Inventory using Remote Sensing, and Its Implications for Near Real-Time Air Quality Applications

A new emissions inventory of particulate matter (PM) is being derived mainly from remote sensing data using fire radiative power (FRP) and aerosol optical depth (AOD) retrievals from the Moderate Resolution Imaging Spectroradiometer (MODIS) instrument, as well as wind data from the Modern Era Retrospective-Analysis for Research and Applications (MERRA) reanalysis dataset, which spans the satellite era. This product is generated using a coefficient of emission, C(sub e), that has been produced on a 1x1 degree global grid such that, when it is multiplied with satellite measurements of FRP or its time-integrated equivalent fire radiative energy (FRE) retrieved over a given area and time period, the corresponding PM emissions are estimated. This methodology of using C(sub e) to derive PM emissions is relatively new and advantageous for near real-time air quality applications compared to current methods based on post-fire burned area that may not provide emissions in a timely manner. Furthermore, by using FRP to characterize a fire s output, it will represent better accuracy than the use of raw fire pixel counts, since fires in individual pixels can differ in size and strength by orders of magnitude, resulting in similar differences in emission rates. Here we will show examples of this effect and how this new emission inventory can properly account for the differing emission rates from fires of varying strengths. We also describe the characteristics of the new emissions inventory, and propose the process chain of incorporating it into models for air quality applications.

Ellison, Luke↗