Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “future buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Building Energy Codes and Grid-Interactive Efficient Buildings: How building energy codes can enable a more dynamic and energy-efficient built environment

This report considers the role of national model codes to promote grid-interactive efficient buildings (GEBs) as part of the modernization of the U.S. electricity grid. It introduces GEBs, describes their ability to support a clean, resilient grid, and considers challenges and approaches for incorporating GEB measures into national model energy codes and standards. Desirable traits of GEB include being low energy, low peaking, and responsive to grid needs, and minimizing the curtailment of renewable energy resources. In addition, the future grid incurs a time and locational value on these types of building services. Accounting for these considerations in future code development requires a continuation and expansion of code-minimum energy efficiency requirements and inclusion of demand responsive and load flexibility measures while ensuring annual use and cost reductions. Also, efforts to include GEB measures in codes will be limited until they are fully developed into an American National Standards Institute (ANSI)-approved standard. Then it would be straightforward to address GEB measures through points or packages and/or scoring requirements. Otherwise, the building code would have to describe each specific grid responsive strategy. This document reviews topics pertinent to considering codes in this context. Specifically, the study presents the status and direction of current building energy codes, the future smart grid, low-energy buildings, and grid-integrated buildings. The report concludes with recommendations for future code development activities to support low-energy, grid-interactive buildings in order to provide added value to building owners, the grid, and society.

24 POWER TRANSMISSION AND DISTRIBUTION↗

U.S. Building Stock Characterization Study: A National Typology for Decarbonizing U.S. Buildings

To support the U.S. Department of Energy's (DOE's) Advanced Building Construction (ABC) Collaborative, the National Renewable Energy Laboratory (NREL) has been tasked with characterizing the U.S. building stock and developing a national typology of buildings. The potential use cases of such a typology are flexible and evolving, but in this initial phase, the primary intention is to help identify technology requirements and engineering solutions for moving the U.S. building stock toward a zero-carbon future by mid-century. This typology will also support the development of appropriate ABC research goals for existing buildings, such as cost targets for new technology development, and in a later phase, the typology can be used to support the implementation of ABC solutions by informing market aggregation and business model development. The ABC Initiative invests in new technologies that enable high building performance, can be deployed quickly with minimal onsite construction time, and are affordable and appealing to building owners, investors, and occupants. Funding awardees use many innovations, including new building materials, 3D printing, offsite manufacturing, robotics, and digital art-to-part. Although the goals of ABC cover a broad range of objectives around energy, comfort, and health, the primary ABC-related application of this national building characterization study is the development of retrofit packages that can be applied to reduce thermal loads in buildings. Retrofit packages will be determined collaboratively by the DOE and the ABC Collaborative. We anticipate a range of upgrade measures covering envelope-, HVAC-, and water-heating-related loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Perovskite Solar Cells Go Bifacial—Mutual Benefits for Efficiency and Durability

Bifacial solar cells hold the potential to achieve a higher power output per unit area than conventional monofacial devices without significantly increasing manufacturing costs. However, efficient bifacial designs are challenging to implement in inorganic thin-film solar cells because of their short carrier lifetimes and high rear surface recombination. The emergence of perovskite photovoltaic (PV) technology creates a golden opportunity to realize efficient bifacial thin-film solar cells, owing to their outstanding optoelectronic properties and unique features of device physics. More importantly, transparent conducting oxide electrodes can prevent electrode corrosion by halide ions, mitigating one major instability issue of the perovskite devices. Here, the theory of bifacial PV devices is summarized and the advantages of bifacial perovskite solar cells, such as high power output, enhanced device durability, and low economic and environmental costs, are reviewed. The limitations and challenges for bifacial perovskite solar cells are also discussed. Lastly, the awareness of bifacial solar cells as a feasible commercialization pathway of perovskite PV for mainstream solar power generation and building-integrated PV is advocated and future research directions are suggested.

14 SOLAR ENERGY↗

Data Summary Report for Soil and Slab Sampling at Former Building 175

Lawrence Livermore National Security (LLNS) and the U.S. Department of Energy (DOE) are in the process of returning the area where Building 175 existed to beneficial use for future site development. The completed assessment will help LLNS and DOE to outline project scope and costs associated with the removal, characterization, and disposal of materials generated when the concrete slab for the former building and any associated remaining subsurface structures are demolished. Slab removal under the Transition & Disposition process requires full screening for potential site contamination to determine appropriate future land use. Borehole locations and depths were designed to correctly assess DOE’s future liability for characterizing residual vadose zone contamination. If a residual source area is identified at depth, DOE will need to evaluate the additional cost of future subsurface cleanup (with limited access) due to planned development. This is necessary to leave the location in a “ready-to-build” status. As a result, Phase II sampling requirements may in some cases extend beyond the construction zone required for slab removal to ensure the necessary due diligence. To avoid the potential spread of contamination and/or the creation of an environmental release by impacting the integrity of known contamination areas (e.g., pit within room 102 and the east to west boundary seam), these locations were not sampled for this project. During demolition of the slab, these locations and their underlying soils should be further evaluated. The assessment was conducted in accord with the May 2022 Lawrence Livermore National Laboratory Former Building 175 Assessment Soil Sampling and Analysis Plan / Quality Assurance Plan. Thirty-six, direct-push borings were advanced, along with collecting concrete (where present) and soil samples for laboratory analyses. Thirty-two of the borings were advanced to a depth of 25 feet below ground (bgs), and four borings were advanced to a depth of 55 feet bgs. The concrete slab for former Building 175 ranged from approximately 8 inches to over two feet in thickness. Soils encountered during the investigation consisted primarily of clayey silt, with interbeds of sandy gravel and silty sand to the total depth explored of 55 feet bgs. Field photoionization detector readings – checking for volatile organic compound (VOC) vapors in soils, ranged from zero (0) to a peak of 33 parts per million at 25 feet bgs in boring PC-B175- 028. The cause for the peak reading is unknown, however, no visually discolored or odorous soils were encountered during the assessment and all VOC results were below Lawrence Livermore National Laboratory’s (LLNL’s) Soil Screening and Management Plan (SSMP) soil screening levels (SSL). Groundwater was not encountered during the assessment and is expected to occur at roughly 65 feet bgs in the project area. No metals were detected at concentrations of concern in the concrete core samples collected and analyzed. Low gross alpha and beta activity concentrations were detected in the concrete core samples collected and analyzed. The detected activity concentrations would appear to be from naturally occurring radioactive isotopes, i.e., potassium 40, present in the raw materials used to make concrete and not artificially added. Tritium was not detected above the testing laboratory's Method Detection Limit (MDL) in any of the concrete core samples collected and analyzed. The radioactive isotopes - actinium 228, bismuth 214, lead 212, lead 214, potassium 40, radium 226, radium 228, and thallium 208, were detected at low activity concentrations in the concrete core samples analyzed. Based on the detected activity concentrations, the isotopes would appear to be naturally occurring in the raw materials used to make concrete and not artificially added. Acetone – a common laboratory contaminant, was detected in nine of the soil samples collected and analyzed. Concentrations of two other volatile organic compounds (benzene and tetrachloroethene) were detected in five of the soil samples analyzed. All concentrations were below SSLs. Total petroleum hydrocarbons as diesel range organics were detected at 43.9 milligrams per kilogram (mg/kg) in the 20-foot bgs duplicate sample from boring PC-B175-007. Total petroleum hydrocarbons as motor oil were detected at 7.20 mg/kg in the 15-foot bgs routine sample from boring PC-B175-001, and at 20.7 mg/kg in the 20-foot bgs duplicate sample from boring PC-B175-007. The SSL for diesel-range TPHs is 260 mg/kg. LLNL does not have an SSL for motor oil range TPHs. No indications of a release, e.g., visibly stained, or odorous soil, were present at the boring locations. No samples collected contained polychlorinated biphenyls (PCBs) in concentrations above the laboratory reporting limit. Arsenic was detected above its SSL of 8.51 mg/kg in the 25-foot bgs routine sample collected from boring PC-B175-023. Nickel was detected above its SSL of 86.0 mg/kg in the 10-foot bgs routine sample from boing PC-B175-005, the 20-foot bgs routine sample from boring PC-B175-025, and the 25-foot bgs routine sample from boring PC-B175-034. The detected concentrations, however, were well below ten times (10x) their respective STLCs. Gross alpha and/or gross beta were detected above their respective SSL activity concentrations in three routine soil samples. Retesting (two per sample) of the samples showed that the initial reported activity concentrations were anomalous. Tritium was not detected in any of the routine or duplicate soil samples collected and analyzed during the investigation. The radioactive isotopes - actinium 228, bismuth 212 and 214, lead 212 and 214, potassium 40, radium 224, 226 and 228, thallium 208, thorium 234 and uranium, were detected at low activity concentrations in the soil samples analyzed for radioactive constituents. The detected isotopes and their associated activity concentrations are typical of those naturally occurring in the marine-type sedimentary deposits underlying the Livermore Valley. No radiological controls are necessary for the soil evaluated.

54 ENVIRONMENTAL SCIENCES↗

Optimizing Facility Operations by Applying Machine Learning to the Army Reserve Enterprise Building Control System (Final Report)

Thousands of U.S. Department of Defense (DoD) buildings have building automation systems (BASs) and/or advanced meters. Although these systems have a wealth of data, performance optimization requires time and expertise to review and act on that information. Machine learning (ML) can provide automated and actionable insights to controls operators. This demonstration implemented proven ML methods on the Army Reserve Enterprise Building Control System. ML refers to algorithms that “learn” from data and improve their performance on a given task over time. In the buildings domain these tasks range from predicting future energy consumption, to identifying operational issues before faults occur, to optimizing control decisions. To learn, ML requires input data, which – for buildings – typically consists of instrument data such as energy consumption data and subsystem controls information such as set-point temperatures, and context data consisting of information such as the physical location of the building, the area of the building, and the weather. ML models use the relationships learned from the input data to make predictions with new, previously unseen, data. The team was able to investigate and successfully implement the following ML use cases: labeling consumption data as anomalous or non-anomalous; baseline whole-building load prediction (unknown fault status); fault detection (validation not possible); and site prioritization for energy-related projects. Due to the constraints of the project, interventions were not able to be implemented during the demonstration; therefore, assessments of operational cost savings and maintenance avoided could not be performed. The project has been presented at two leading national building conferences and two additional publications to peer-reviewed journals are currently in preparation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial PV Property Characterization: An Analysis of Solar Deployment Trends in Commercial Real Estate

The commercial rooftop solar energy market remains an under-developed sector. The market is estimated to contain 150 gigawatts of potential in the U.S. but it faces significant barriers to deployment to meet that potential, with an estimated 1.4 GW developed through 2017. This analysis focuses on of over 30,000 solar systems installed through 2017 and the properties on which they are located. The sample represents greater than 60% of the installed market at that time. The properties covered 20 states and almost 30 different types including industrial, warehouse, school/university, office, retail, and municipal/government and were compared to more than 2.4 million non-solar properties in the same geographies. The analysis finds overall commercial rooftop PV penetrations have only surpassed 1% recently across all property types with education properties (schools and universities) leading at over 6% penetration and with NJ and CA seeing the highest overall penetrations close to 2.5%. Also revealed were characteristics of those buildings, owners, and tenants and how solar penetrations change as those characteristics change. The research found clearly higher penetrations on owner-occupied larger (~9000 ft 2 ) buildings with fewer tenants indicating, potentially, areas for future customer acquisition for PV developers. Also investigated were differences of solar system characteristics on commercial buildings such as system installed prices, size, and percentages of third-party owned (TPO) systems. The research found a steady and substantial drop in installed prices over time, a drop in the percentage of TPO systems being installed, and a relatively steady trend of system size. This latter finding indicates that smaller systems remain difficult to develop.

14 SOLAR ENERGY↗

NASA’s Space Launch System: Enabling a New Generation of Lunar Exploration

Following two decades of operational experience in low-Earth orbit (LEO), NASA has turned its focus once again to deep space exploration. The Agency is building the Space Launch System (SLS) to take astronauts and cargo to the Moon and send robotic spacecraft deep into the solar system. Offering unmatched performance, departure energy and payload capacity, SLS is designed to evolve into progressively more powerful configurations, enabling a new generation of human exploration of the Moon in preparation for future missions to Mars. The first build of the Block 1 vehicle is nearly complete for Exploration Mission-1 (EM-1), the first integrated flight of SLS and the Orion crew vehicle. EM-1 will send an uncrewed Orion to a distant retrograde lunar orbit in order to test and verify new systems, and along the way will deploy 13 6U-class CubeSats in deep space along the upper stage disposal trajectory after separation from Orion. The Agency’s current plans call for the first three missions on the SLS manifest to utilize the Block 1 vehicle in crew and cargo configurations. A more powerful evolved vehicle, Block 1B, will provide additional mass and volume performance using a new Exploration Upper Stage (EUS). Block 1B will lift 34 to 40 metric tons (t) to trans-lunar injection (TLI), depending on crew or cargo configuration. The Block 1B crew configuration will offer as much payload volume as industry-standard 5 m-diameter fairings to co-manifested payloads in a Universal Stage Adapter (USA). The Block 1B cargo variant will accommodate 8.4 meter-diameter fairings in 62.7-foot (19.1 meter) or 90-foot (27.4 meter) lengths. Adding smallsat secondary payloads to ride along with primary and co-manifested payloads on future flights may be possible, depending on mass margins. Leveraging a flight-proven, well-understood propulsion system, SLS’s flexible architecture, unmatched performance and expansive payload accommodations will open exciting new mission possibilities in deep space. Launches of habitat modules for NASA’s new Gateway lunar outpost, the next generation of robotic spacecraft to the far reaches of the solar system, large-aperture deep space telescopes, probes to interstellar space and the return of astronauts to the Moon are all possible with SLS.

Creech, Stephen D.↗

Completing the Circuit: Workforce Development for Advanced Building Construction and Grid-Interactive Efficient Buildings

This paper will present key findings from a future-oriented qualitative study investigating likely futures for the next 5-10 years in the architecture, engineering, construction, and operations industry. This research offers an original contribution to the buildings industry by articulating an actionable framework to more effectively build connections between built environment fields. Whereas the ideal of interdisciplinary, research driven practice underlies the approach to pedagogy at many schools of architecture, innovation in the profession, such as the integrated design process, has been limited. This project applies Legitimation Code Theory (LCT) to the analysis of data gathered from interviews and a review of industry reports.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building a custom high-throughput platform at the Joint Genome Institute for DNA construct design and assembly—present and future challenges

Abstract The rapid design and assembly of synthetic DNA constructs have become a crucial component of biological engineering projects via iterative design–build–test–learn cycles. In this perspective, we provide an overview of the workflows used to generate the thousands of constructs and libraries produced each year at the U.S. Department of Energy Joint Genome Institute. Particular attention is paid to describing pipelines, tools used, types of scientific projects enabled by the platform and challenges faced in further scaling output.

36 MATERIALS SCIENCE↗

How Frequent Will the Rarest Daily Rainfall Records of Hurricane Ida’s Remnants Be in the Future?

Abstract Gaining continued insights into the impact of global warming on the occurrence of hurricane-associated intense record downpours is essential for building climate resilient communities. This study investigates projected future changes in extreme rainfall over the Northeast United States, as represented by extreme daily amounts during Hurricane Ida in 2021. We used historical control simulations of Weather Research and Forecasting (WRF) Model generated from 40 years of weather events (1980–2014, 12 km) forced by the fifth generation European Centre for Medium-Range Weather Forecasts atmospheric reanalysis. These simulations are thermodynamically modified (2060–2100) via an imposed warming for the high-emission scenario of shared socioeconomic pathway (SSP585) from a range of general circulation models. Ground observations from the Global Historical Climatology Network (1950–2014) and WRF simulations (historical, 1980–2014, and future, 2060–2100) are integrated into a nonstationary generalized extreme value (GEV) framework to assess the frequency of Ida’s heaviest daily rain rates under the SSP585 scenario. Results show that Ida’s daily maximum rainfall recorded at different observation locations was higher than the single highest September daily maximum observed (1950–2014) for 5 out of 17 stations (∼30% of the stations). Ida-like extreme daily rain rates are projected to be, on average, more than 2 times more likely to occur at the end of the century in the simulations (with some regions as high as 5 times). This work demonstrates that integrating a high-resolution atmospheric model’s present-day and thermodynamically modified future simulations along with ground observations, within a nonstationary statistical framework, is crucial for understanding changing characteristics of extreme weather events. Significance Statement Daily scale extreme precipitation is expected to become more frequent and severe, as evidenced by observations and model simulations. While it is important to investigate how these intensifying heavy rainfall events affect current engineering standards, fewer studies have contextualized how warming impacts the most extreme rainfall from a single storm event relative to historical heavy downpours. In this study, we focused on the daily extreme rainfall associated with the extratropical transition of Hurricane Ida (2021), particularly over the northeastern United States—some of which exceeded the commonly used hydrologic design criteria for a 100-yr storm. Using a high-resolution atmospheric model simulation, we investigated how continued warming may influence the frequency of such daily rain rates. Under a high-emission scenario, these events are projected to become up to 5 times more likely at the end of the twenty-first century.

Dollan, Ishrat J↗

Empowering Energy Efficiency in Existing Big-Box Retail/Grocery Stores (Final Optimization Report)

The Center for Sustainable Energy (CSE), in partnership with the National Renewable Energy Laboratory (NREL), TRC Energy Services, P2S Engineering Inc, Walmart, and five innovative technology providers, are to demonstrate the impact of an integrated suite of pre-commercial energy efficiency (EE) technologies in a large, existing, retail building located within an inland disadvantaged community. Proposed technology packages include three categories of advanced EE solutions: heating, ventilating, air-conditioning, and refrigerating (HVAC/R); lighting; and integrated system and building level controls. The project is designed to impact Walmart’s future store specifications, which can be replicated and deployed in other buildings across California with similar end-use and system characteristics. The following lists the technologies considered for this project: DualCool (HVAC evaporative cooling); Software Motor Company (SMC) (HVAC and refrigeration fan motor); I2S: DC LED lighting; LocBit: building energy management and optimization; Saya: water monitoring.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of Semi-Autonomous Tools for ISS Commanding and Monitoring

As the International Space Station (ISS) has moved into a utilization phase, operations have shifted to become more ground-based with fewer mission control personnel monitoring and commanding multiple ISS systems. This shift to fewer people monitoring more systems has prompted use of semi-autonomous console tools in the ISS Mission Control Center (MCC) to help flight controllers command and monitor the ISS. These console tools perform routine operational procedures while keeping the human operator "in the loop" to monitor and intervene when off-nominal events arise. Two such tools, the Pre-positioned Load (PPL) Loader and Automatic Operators Recorder Manager (AutoORM), are used by the ISS Communications RF Onboard Networks Utilization Specialist (CRONUS) flight control position. CRONUS is responsible for simultaneously commanding and monitoring the ISS Command & Data Handling (C&DH) and Communications and Tracking (C&T) systems. PPL Loader is used to uplink small pieces of frequently changed software data tables, called PPLs, to ISS computers to support different ISS operations. In order to uplink a PPL, a data load command must be built that contains multiple user-input fields. Next, a multiple step commanding and verification procedure must be performed to enable an onboard computer for software uplink, uplink the PPL, verify the PPL has incorporated correctly, and disable the computer for software uplink. PPL Loader provides different levels of automation in both building and uplinking these commands. In its manual mode, PPL Loader automatically builds the PPL data load commands but allows the flight controller to verify and save the commands for future uplink. In its auto mode, PPL Loader automatically builds the PPL data load commands for flight controller verification, but automatically performs the PPL uplink procedure by sending commands and performing verification checks while notifying CRONUS of procedure step completion. If an off-nominal condition occurs during procedure execution, PPL Loader notifies CRONUS through popup messages, allowing CRONUS to examine the situation and choose an option of how PPL loader should proceed with the procedure. The use of PPL Loader to perform frequent, routine PPL uplinks offloads CRONUS to better monitor two ISS systems. It also reduces procedure performance time and decreases risk of command errors. AutoORM identifies ISS communication outage periods and builds commands to lock, playback, and unlock ISS Operations Recorder files. Operation Recorder files are circular buffer files of continually recorded ISS telemetry data. Sections of these files can be locked from further writing, be played back to capture telemetry data that occurred during an ISS loss of signal (LOS) period, and then be unlocked for future recording use. Downlinked Operation Recorder files are used by mission support teams for data analysis, especially if failures occur during LOS. The commands to lock, playback, and unlock Operations Recorder files are encompassed in three different operational procedures and contain multiple user-input fields. AutoORM provides different levels of automation for building and uplinking the commands to lock, playback, and unlock Operations Recorder files. In its automatic mode, AutoORM automatically detects ISS LOS periods, then generates and uplinks the commands to lock, playback, and unlock Operations Recorder files when MCC regains signal with ISS. AutoORM also features semi-autonomous and manual modes which integrate CRONUS more into the command verification and uplink process. AutoORMs ability to automatically detect ISS LOS periods and build the necessary commands to preserve, playback, and release recorded telemetry data greatly offloads CRONUS to perform more high-level cognitive tasks, such as mission planning and anomaly troubleshooting. Additionally, since Operations Recorder commands contain numerical time input fields which are tedious for a human to manually build, AutoORM's ability to automatically build commands reduces operational command errors. PPL Loader and AutoORM demonstrate principles of semi-autonomous operational tools that will benefit future space mission operations. Both tools employ different levels of automation to perform simple and routine procedures, thereby offloading human operators to perform higher-level cognitive tasks. Because both tools provide procedure execution status and highlight off-nominal indications, the flight controller is able to intervene during procedure execution if needed. Semi-autonomous tools and systems that can perform routine procedures, yet keep human operators informed of execution, will be essential in future long-duration missions where the onboard crew will be solely responsible for spacecraft monitoring and control.

Brzezinski, Amy S.↗

AutoBEM: A scalable framework for nationwide building energy simulation and retrofit evaluation in the United States

This paper presents AutoBEM, an integrated, automated framework for nationwide building energy modeling and retrofit evaluation in the United States. Unlike prior UBEM platforms that either rely primarily on representative stock sampling or operate at city scale, AutoBEM automates the generation of building-resolved, physics-based EnergyPlus/OpenStudio simulation models at national scale using GIS-derived geometry, prototype-based assumptions, and standardized scalable workflows. Leveraging the Model America dataset and high-performance computing, AutoBEM generates and simulates energy models for 122.9 million buildings, representing 97.8% of the U.S. building stock. These models are being made publicly and freely available as the Model America v1.0 (MAv1) dataset. AutoBEM supports detailed, building-level assessments of energy consumption, CO2 emissions, and post-processed anthropogenic heat emissions (AHE), and evaluates 151 energy conservation measures (ECMs) using localized utility pricing and building characteristics. In addition, AutoBEM incorporates both typical and future climate conditions through integration with Typical Meteorological Year (TMY) and Future TMY (fTMY) weather data derived from IPCC scenarios. In a case study of Phoenix, Arizona, AutoBEM identified several high-efficiency HVAC upgrades and selected envelope measures with short modeled payback periods (1.5 years) for certain building types and standards. Simulations under future climate scenarios (SSP5–RCP8.5) project an 11.3% increase in electricity use and a 32% reduction in natural gas demand by 2100, underscoring the need for climate-adaptive retrofit planning. By enabling reproducible, bottom-up, and location-specific analysis at scale, AutoBEM provides a step toward a national digital twin of the built environment and supports data-driven screening and planning for decarbonization, resilience, and energy equity.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

Building Columbia from the System Administrator View

This document is about NASA advanced supercomputing by building Columbia through the configuration of its software, hardware, and network. The content also includes future plans which include tight scheduling, maintaining production while building Columbia and continued production work while reworking the facilities to acommodate Columbia.

Chan, Davin↗

US building energy efficiency and flexibility as an electric grid resource

Buildings consume 75% of U.S. electricity; therefore, improving the efficiency and flexibility of building operations could increase the reliability and resilience of the rapidly-changing electricity system. We estimate the technical potential near- and long-term impacts of best available building efficiency and flexibility measures on annual electricity use and hourly demand across the contiguous U.S. Co-deployment of building efficiency and flexibility avoids up to 742 TWh of annual electricity use and 181 GW of daily net peak load in 2030, rising to 800 TWh and 208 GW by 2050; at least 59 GW and 69 GW of the peak reductions are dispatchable. Implementing efficiency measures alongside flexibility measures reduces the potential for off-peak load increases, underscoring limitations on load shifting in efficient buildings. Overall, however, we find a substantial building-grid resource that could reduce future fossil-fired generation needs while also reducing dependence on energy storage with increasing variable renewable energy penetration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Assessments of Demand Flexibility from Grid-Interactive Efficient Buildings: Issues and Considerations

This SEE Action Network report explains basic concepts and fundamental considerations for assessing the actual demand flexibility performance of buildings participating in demand flexibility programs and responding to time-varying retail rates. Demand flexibility is the capability of distributed energy resources (DERs) to adjust a building’s load profile across different timescales. Assessments determine the timing, location, quantity, and quality of grid services provided. The results can be used for financial settlements and to improve performance of demand flexibility, support its consideration in resource potential studies and electricity system planning, and contribute to cost-effectiveness evaluations. While practitioners and regulators regularly find opportunities to improve performance assessments of demand-related services, to a large degree current best practices are sufficient for basic service offerings as demand flexibility is implemented today. However, advances in assessment practices will be required in a future with grid-interactive efficient buildings (GEBs) that provide continuous demand flexibility by integrating multiple DERs and flexibility modes (load shed, load shift, modulate, and generate). Example practices include using new baseline constructs—including whether baselines are even required for certain building flexibility modes or configurations, deploying more advanced metering and analytics, further developing cybersecurity standards, improving communication standards for increased interoperability, and establishing performance metrics and assessment procedures for load modulation as it is more fully defined and implemented. This report provides information on prioritizing and designing performance assessment elements for demand flexibility programs and time-varying retail rates, assessment protocols, and research and development needs. Additional research sponsored by DOE’s Building Technologies Office offers more detailed technical information on assessing performance of demand flexibility, including definition of performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗