Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Comparison of total emitted solar-induced chlorophyll fluorescence (SIF) and top-of-canopy (TOC) SIF in estimating photosynthesis

We report many studies have shown that solar-induced fluorescence (SIF) has a good potential to predict gross primary production (GPP) of vegetation. What we measured by remote sensing or near-surface platforms is top-of-canopy (TOC) SIF (SIF toc ), which is not necessarily equal or proportional to total emitted SIF (SIF tot ) from the entire canopy due to the (re)absorption and scattering effects. However, photosynthesis, the process that plants use to fix carbon from the atmosphere, occurs at the entire vertical canopy. Here, by using the recollision theory, we calculated SIF tot at 760 nm from the measured SIF toc , hyperspectral reflectance (R), canopy interception (i) and leaf albedo (ω l ). Among them, both SIF toc and R can be obtained from concurrent TOC spectral measurements; i and ω l in the near-infrared region can be estimated from the open access datasets with a good accuracy. Our result confirms that the measured SIF toc only accounts for a small fraction of SIF tot : the above-the-canopy sensor can only “see” on average 22.9% of SIF tot at Harvard Forest. SIF tot has the following advantages over SIF toc in estimating GPP: (1) SIF tot improves the diurnal estimate of canopy GPP, especially capable to capture the midday depression of photosynthesis which may cause the large discrepancies between SIF toc and GPP on a diurnal basis, (2) SIF tot produces a stronger correlation with GPP from plants with complex canopy structure or under sky conditions with more diffuse irradiance, and (3) the SIF tot -GPP relationship shows a stronger resilience to environmental stresses. The fluorescence escape ratio (f esc ), the ratio between SIF toc multiplied by π and SIF tot , is mostly determined by the sun-canopy-sensor geometry and leaf inclination distribution. The effect of LAI and the leaf chlorophyll concentration on f esc is marginal at the 760 nm wavelength. Our results suggest that converting SIF toc into SIF tot provides a better tool to understand and estimate GPP.

54 ENVIRONMENTAL SCIENCES↗

Laser-induced fluorescence of filament-produced plasmas

Self-guided ultrafast laser filaments are a promising method for laser beam delivery and plasma generation for standoff and remote detection of elements and isotopes via filament-induced breakdown spectroscopy (FIBS). Yet, there are several challenges associated with the practical application of FIBS, including delivery of sufficient laser energy at the target for generating plasma with a copious amount of emission signals for obtaining a high signal-to-noise ratio. Here, in this study, we use laser-induced fluorescence (LIF) to boost the emission signal and reduce self-reversal in the spectral profiles. Ultrafast laser filaments were used to produce plasmas from an Al 6061 alloy target at various standoff distances from 1 to 10 m. For LIF emission enhancement, a narrow linewidth continuous-wave laser was used in resonance with a 394.40 nm Al I resonant transition, and the emission signal was monitored from the directly coupled transition at 396.15 nm. Emission signal features of Al I are significantly enhanced by resonant excitation. In addition, LIF of filament ablation plumes reduces the self-reversal features seen in the thermally excited spectral profiles. Time-resolved two-dimensional fluorescence spectroscopy was performed for evaluating the optical saturation effects, which are found to be non-negligible due to high Al atomic densities in the filament-produced plasmas.

47 OTHER INSTRUMENTATION↗

Development of Multi-Scale X-ray Fluorescence Tomography for Examination of Nanocomposite-Treated Biological Samples

Research in cancer nanotechnology is entering its third decade, and the need to study interactions between nanomaterials and cells remains urgent. Heterogeneity of nanoparticle uptake by different cells and subcellular compartments represent the greatest obstacles to a full understanding of the entire spectrum of nanomaterials’ effects. In this work, we used flow cytometry to evaluate changes in cell cycle associated with non-targeted nanocomposite uptake by individual cells and cell populations. Analogous single cell and cell population changes in nanocomposite uptake were explored by X-ray fluorescence microscopy (XFM). Very few nanoparticles are visible by optical imaging without labeling, but labeling increases nanoparticle complexity and the risk of modified cellular uptake. XFM can be used to evaluate heterogeneity of nanocomposite uptake by directly imaging the metal atoms present in the metal-oxide nanocomposites under investigation. While XFM mapping has been performed iteratively in 2D with the same sample at different resolutions, this study is the first example of serial tomographic imaging at two different resolutions. A cluster of cells exposed to non-targeted nanocomposites was imaged with a micron-sized beam in 3D. Next, the sample was sectioned for immunohistochemistry as well as a high resolution “zoomed in” X-ray fluorescence (XRF) tomography with 80 nm beam spot size. Multiscale XRF tomography will revolutionize our ability to explore cell-to-cell differences in nanomaterial uptake.

60 APPLIED LIFE SCIENCES↗

Polymer Size–Catalytic Activity Relationships in Solution by Fluorescence Correlation Spectroscopy

Measuring the catalytic activity of specific sizes of polymers with active catalysts in solution is typically challenging, due to limited instrument detection sensitivity and/or dynamic range. Here, a fluorescence correlation spectroscopy (FCS) method is developed to determine the catalytic activity of living polymers of a specific apparent size in solution. Deviation from a single-component FCS data fitting, as assessed by χ2, is also introduced and developed as a “speciation index”—a method to evaluate and track changes in the relative amount of distinct polymer sizes with reaction progress. These methods are enabled by incorporating a selectively reactive fluorescent monomer into growing polydicyclopentadiene or polynorbornene during ring-opening metathesis polymerization (ROMP). Compared to polynorbornene, data showed that catalysts in aggregates of polyDCPD retained higher activity for longer—outcomes not directly inferable from simple diffusional-access predictions. Here, the ability to assign catalytic activity to polymers of specific sizes, and then to determine how this activity evolves with reaction progress, support long-term goals in the development and measurement of nano-objects that possess size-dependent catalytic activity.

Active catalyst↗

Laser-Induced Recoverable Fluorescence Quenching of Perovskite Films at a Microscopic Grain Scale

Understanding the fundamental properties of metal-halide perovskite materials is driving the development of novel optoelectronic applications. Here, in this paper, we report the observation of a recoverable laser-induced fluorescence quenching phenomenon in perovskite films with a microscopic grain-scale restriction, accompanied by spectral variations. This fluorescence quenching depends on the laser intensity and the dwell time under Auger recombination dominated conditions. These features indicate that the perovskite lattice deformation may take the main responsibility for the transient and show a new aspect to understand halide perovskite photo-stability. We further modulate this phenomenon by adjusting the charge carrier recombination and extraction, revealing that efficient carrier transfer can improve the bleaching resistance of perovskite grains. Our results provide future opportunities to attain high-performance devices by tuning the perovskite lattice disorder and harvesting the energetic carriers.

36 MATERIALS SCIENCE↗

Attributing differences of solar-induced chlorophyll fluorescence (SIF)-gross primary production (GPP) relationships between two C4 crops: corn and miscanthus

There remains limited information to characterize the solar-induced chlorophyll fluorescence (SIF)-gross primary production (GPP) relationship in C4 cropping systems. The annual C4 crop corn and perennial C4 crop miscanthus differ in phenology, canopy structure and leaf physiology. Investigating the SIF-GPP relationships in these species could deepen our understanding of SIF-GPP relationships within C4 crops. Using in situ canopy SIF and GPP measurements for both species along with leaf-level measurements, we found considerable differences in the SIF-GPP relationships between corn and miscanthus, with a stronger SIF-GPP relationship and higher slope of SIF-GPP observed in corn compared to miscanthus. These differences were mainly caused by leaf physiology. For miscanthus, high non-photochemical quenching (NPQ) under high light, temperature and water vapor deficit (VPD) conditions caused a large decline of fluorescence yield (Φ F ), which further led to a SIF midday depression and weakened the SIF-GPP relationship. The larger slope in corn than miscanthus was mainly due to its higher GPP in mid-summer, largely attributed to the higher leaf photosynthesis and less NPQ. Furthermore, our results demonstrated variation of the SIF-GPP relationship within C4 crops and highlighted the importance of leaf physiology in determining canopy SIF behaviors and SIF-GPP relationships.

54 ENVIRONMENTAL SCIENCES↗

In-situ two-dimensional temperature measurements using x-ray fluorescence spectroscopy in laminar flames with high silica particle concentrations

X-ray fluorescence spectroscopy (XRF) was used to measure temperatures and study mixing, for the first time in silica particle synthesis flames. Hexamethyldisiloxane (HMDSO) and trimethylsilanol (TMSO) were the particle precursors. A multi-element diffusion burner was used to produce a flat methane flame, and the precursors, dilute in inert gas, were injected via a central jet. Krypton was the fluorescent medium at 3.2 % concentration by volume. Scans with Kr in the central flow and not in the main flow were made to assess the mixing effects between the central and main gas flows. When HMDSO or TMSO were added, a secondary diffusion flame formed between the jet and the main methane flame. The results revealed a dramatic change in the centerline temperature profile of the jet gases when HMDSO or TMSO were added. The main methane flame stoichiometry also affected the temperature profiles. The results show HMDSO and TMSO reactions are initiated in a lowtemperature and low-oxygen concentration region of the jet where thermal decomposition is not expected to be significant. Reaction of the particle precursors is therefore attributed to radical transport from the main methane flame. In the current work, particle number densities of up to 270 g/m 3 locally are estimated. Thus, the study also demonstrates the capability of the XRF technique for high spatial fidelity measurements in flames with high concentrations of condensed-phase particles, leveraging the attribute that the XRF signal is generally not impacted by condensed-phase interferences. In conclusion, the observations and data obtained in this study inform likely reaction pathways for this important class of siloxane compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-intrusive temperature measurements in the vicinity of a thermocouple using synchrotron x-ray fluorescence

A highly spatially resolved synchrotron x-ray fluorescence (XRF) thermometry technique has been used to map temperature fields around a 125 mu m type R thermocouple immersed in a stoichiometric premixed methane flame. The high spatial resolution of the XRF technique allowed temperatures to be measured close to the thermocouple and the impact of the thermocouple on the flame to be assessed. This paper discusses some of the nontrivial challenges of these measurements including the recovery of spectral features from the krypton fluorescent agent that are overlapped by those from the thermocouple metals at locations near the bead surface. The calculated temperatures from 1D premixed flame simulations are in excellent agreement with measurements along the centerline. The results show that the 125 mu m thermocouple induces minimal disturbances to the gas flow and any catalytic effects originating from the bare wires are also inconsequential. Here, the methodology has advanced to a stage where it enables comparisons between the gas temperature in the vicinity of the thermocouple and the actual thermocouple reading.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unpacking the drivers of diurnal dynamics of sun-induced chlorophyll fluorescence (SIF): Canopy structure, plant physiology, instrument configuration and retrieval methods

Sun-induced chlorophyll fluorescence (SIF) from spaceborne sensors is a promising tool for global carbon cycle monitoring, but its application is constrained by insufficient understanding of the drivers underlying diurnal SIF dynamics. SIF measurements from ground-based towers can reveal diurnal SIF dynamics across biomes and environmental conditions; however, meaningful interpretation of diurnal variations requires disentangling impacts from canopy structure, plant physiology, instrument configuration and retrieval methods, which often interact with and confound each other. This study aims to unpack these drivers using 1) concurrent ground and airborne canopy-scale and leaf-scale measurements at a corn field, 2) a mechanistic SIF model that explicitly considers the dynamics of photochemistry (via the fraction of open photosystem II reaction centers, qL) and photoprotection (via nonphotochemical quenching, NPQ) as well as their interactive dependence on the sub-canopy light environment, and 3) cross-comparison of SIF instrument configurations and retrieval methods. We found that crop row orientations and sun angles can introduce a distinctive midday dip in SIF in absence of stress, due to a midday drop of absorbed photosynthetically active radiation (APAR) when crop rows are north-south oriented. Canopy structure caused distinctive responses in both qL and NPQ at different positions within the vertical canopy that collectively influenced fluorescence quantum yield (Φ F ) at the leaf scale. Once integrated at the canopy scale, diurnal dynamics of both APAR and canopy escape probability (ε) are critical for accurately shaping diurnal SIF variations. While leaf-level qL and NPQ exhibited strong diurnal dynamics, their influence was attenuated at the canopy scale due to opposing effects on SIF at different canopy layers. Furthermore, different system configurations (i.e., bi-hemispherical vs. hemispherical-conical) and retrieval methods can bias the SIF magnitude and distort its diurnal shapes, therefore confounding the interpretation of inherent strength and dynamics of SIF emission. Our findings demonstrate the importance of crop row structures, interactive variations in canopy structure and plant physiology, instrument configuration, and retrieval method in shaping the measured dynamics of diurnal SIF. This study highlights the necessity to account for these factors to accurately interpret satellite SIF, and informs future synthesis work with different SIF instrumentation and retrieval methods across sites.

59 BASIC BIOLOGICAL SCIENCES↗

Enzymatically hydrolyzed fluorescence-based chemical probe enables in situ mapping of chitinase activity in the rhizosphere

Rhizosphere microbiomes and root exudates play a pivotal biochemical role in helping to catalyze chitin catabolism. Chitin is a recalcitrant and ubiquitous soil biopolymer, estimated to be the second most abundant organic soil biopolymer on Earth. Despite its abundance, role as a source of C and N in soil, and importance to ecosystem function, the biochemical mechanisms controlling chitin fate in the rhizosphere are elusive and poorly understood. To enable spatial mapping of chitinase activity in the rhizosphere, we designed and synthesized an enzymatically activated fluorogenic substrate, chitotriose-TokyoGreen (chitotriose-TG), by incorporating a fluorescein derivative (TG) onto the trimeric unit of chitin. This non-fluorescent substrate is selectively hydrolyzed by chitinase to release TG and yield a high fluorescence signal, which can be used to spatially image and measure chitinase activity in the rhizosphere. To demonstrate the application of this technique, we grew switchgrass (Panicum virgatum) in rhizoboxes amended with a horizontal layer of chitin. We extracted mobile proteins from the rhizobox using a nitrocellulose membrane blotting technique which offer non-destructive enzyme extraction while preserving the 2D spatial position of the enzymes. We then subjected these membranes to the synthesized chitotriose-TG stain to spatially visualize the distribution of chitinase activity within the rhizosphere. Furthermore, we observed increased chitinase activity near plant roots and higher activity within the soil zone enriched in chitin, showing an adaptive response of chitinase activity with spatial focusing in areas of higher chitin abundance. Thus, the enzyme extraction and visualization strategy we describe here can help enlighten efforts to better understand spatial controls on chitin breakdown in rhizosphere, further elucidating the role of chitin as a C and N source in these systems.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring chemistry with single-molecule and -particle fluorescence microscopy

The evolution of single-molecule and -particle fluorescence microscopy imaging techniques for the investigation of chemical reactions yielded achievements at all fronts, from synthetic organic chemistry to materials science. The removal of ensemble averaging effects uncovers unique, otherwise hidden reaction intermediates, reactivity, and kinetics. Thus, new insights can be obtained even for well-explored chemical reactions and processes. The aim of this article is to serve as a guide and a source of inspiration for scientists who wish to develop single-molecule and -particle fluorescence microscopy to answer questions in chemistry. Here, we describe the current status of technical accomplishments in the field and point out technical and conceptual obstacles for overcoming in the near future, with focus on improvement of bench-scale synthetic reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanofocused Scanning X-ray Fluorescence Microscopy Revealing an Effect of Heterozygous Hemoglobin S and C on Biochemical Activities in Plasmodium falciparum -Infected Erythrocytes

While there is ample evidence suggesting that carriers of heterozygous hemoglobin S and C are protected from life-threatening malaria, little is known about the underlying biochemical mechanisms at the single cell level. In this work, using nanofocused scanning X-ray fluorescence microscopy, we quantify the spatial distribution of individual elements in subcellular compartments, including Fe, S, P, Zn, and Cu, in Plasmodium falciparum -infected ( P. falciparum -infected) erythrocytes carrying the wild type or variant hemoglobins. Our data indicate that heterozygous hemoglobin S and C significantly modulate biochemical reactions in parasitized erythrocytes, such as aberrant hemozoin mineralization and a delay in hemoglobin degradation. The label-free scanning X-ray fluorescence imaging has great potential to quantify the spatial distribution of elements in subcellular compartments of P. falciparum -infected erythrocytes and unravel the biochemical mechanisms underpinning disease and protective traits.

59 BASIC BIOLOGICAL SCIENCES↗

Advanced Analysis of X-ray Fluorescence Measurements of the Interfacial Density of Eu Ions at Liquid–Liquid Interfaces for Solvent Back-Extraction

X-ray fluorescence near total reflection (XFNTR) is the primary technique used to measure the element-specific interfacial density of ions at liquid−liquid interfaces. Fluorescence from ions in the bulk liquids can complicate the determination of the interfacial density; consequently, measurements have been previously limited to samples without ions in the upper phase and with concentrations on the order of 10 μM or less in the lower phase. We modify the analysis of XFNTR data to account for ions in both bulk phases, then demonstrate its use in the context of rare-earth separations processes. In a model of ion stripping (i.e., back-extraction), dodecane solutions of di(2-ethylhexyl)- phosphoric acid (HDEHP) loaded with Eu(III) at the 1 mM level are placed in contact with either pure water or aqueous solutions of nitric or citric acid at pH 3. XFNTR measurements of equilibrated, quiescent samples reveal that citric acid solutions produce a disproportionately large depletion of ions from the interface compared to that from the bulk organic solution, whereas stripping by pure water or nitric acid solutions is negligible. As a result, this advance in the methodology of XFNTR may have broad applicability to the investigation of metal ions in chemical and biological processes at liquid−liquid interfaces.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Small Molecule Sorting: A Fluorescence Study of Microemulsions

The application of microemulsions to a wide range of industries relies on their ability to solubilize small molecules with vastly different structures. Herein, we use multiple fluorescence techniques to probe ionic (rhodamine 6g, r6g), polar (coumarin 153, c153), nonpolar (diphenylanthracene, DPA), and amphiphilic (laurdan) small molecules in a nonionic, bicontinuous microemulsion of varying hydration. All fluorophores investigated were found to associate with the surfactant region despite their different structures and properties. The hydration of the surfactant layer was found to increase linearly with water addition, but while this initially increases the fluidity of the surfactant layer, fluorescence anisotropy of c153 and r6g indicates a stiffening of the surfactant at water content >60%. This stiffening of the surfactant layer at higher water content correlates with a morphological change in the microemulsion from a bicontinuous structure to droplets. In contrast, the nonpolar DPA shows a change in partitioning as hydration changes, increasing its association with the oil domain. Altogether, these studies elucidate not only the capability of these microemulsions to host a range of small molecules in the surfactant layer with tunable position but also the ability to probe the driving force of bulk structural changes in these heterogeneous fluids.

25 ENERGY STORAGE↗

Solvent-Induced Swelling Behaviors of Microphase-Separated Polystyrene- block -Poly(ethylene oxide) Thin Films Investigated Using In Situ Spectroscopic Ellipsometry and Single-Molecule Fluorescence Microscopy

Block copolymers have attracted considerable interest in the fields of nanoscience and nanotechnology, because these polymers afford well-defined nanostructures via self-assembly. An in-depth understanding of solvent effects on the physicochemical properties of these microdomains is crucial for their preparation and utilization. Herein, we employed in situ spectroscopic ellipsometry and single-molecule fluorescence techniques to gain detailed insights into microdomain properties in polystyrene-block-poly(ethylene oxide) (PS-b-PEO) films exposed to ethanol- and water-saturated N 2 . We observed a quick increase and a subsequent gradual decrease in the ellipsometric thickness of PS-b-PEO films upon exposure to ethanol-saturated N 2 . This observation was unexpected because ethanol-saturated N 2 induced negligible thickness change for PS and PEO homopolymer films. The similarity in maximum thickness gain observed under ethanol- and water-saturated N 2 implied the swelling of PEO microdomains. Ethanol vapor permeation through the PEO microdomains was supported by the red-shift of the ensemble and single-molecule fluorescence emission of Nile red in PS-b-PEO films. Single-molecule tracking data showed the initial enhancement and subsequent reduction of the diffusion of hydrophilic sulforhodamine B molecules in PS-b-PEO films upon exposure to ethanol-saturated N 2 , consistent with the spectroscopic ellipsometry results. Furthermore, the higher ethanol susceptibility of the PEO microdomains was attributable to their amorphous nature, as shown by FTIR data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Molecule Fluorescence Investigations of Solute Transport Dynamics in Nanostructured Membrane Separation Materials

Many materials used for membrane separations comprise of nanoscale structures such as pores and domains. Such nanostructures often control the solute permeability and selectivity of separation membranes. Thus, for future development of highly efficient separation membranes, it is important to understand the structural and chemical properties of these nanostructures, and also their influences on solute transport dynamics. For the last two decades, single-molecule fluorescence techniques have been used to measure the detailed dynamics of solute molecules diffusing in various nanostructured materials, giving valuable insights into molecular transport mechanisms influenced by nanoscale material heterogeneity. This Perspective will discuss recent single-molecule fluorescence studies on solute diffusion in materials relevant to membrane separations, including dense polymer films and nanoporous materials. These studies have revealed the formation and properties of nanostructures, and unique transport dynamics of solute molecules manipulated by their confinement and partitioning to the nanostructures, which play key roles in membrane separations. Furthermore, this Perspective will also point out scientific challenges toward thorough understanding of molecular-level mechanisms in membrane separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence-Enabled Self-Reporting for Redox Flow Batteries

Monitoring battery health is challenging. Self-reporting enables the rapid health assessment of redox flow batteries (RFBs) and provides insight into degradation mechanisms of electrochemically active molecules (redoxmers). In this study, we introduce fluorescence as an orthogonal property to probe this chemistry in situ. An established anolyte redoxmer, 2,1,3-benzothiadiazole, is rendered an efficient blue-green fluorophore through minimalistic derivatization. One of the derivatives is electrochemically reversible with a long lifetime and cycling stability in the charged state. Spectroscopic measurements on this new redoxmer reveal strong effects of the electrolyte cation on the fluorescence that are useful for probing the solvent microenvironment. Using this probe, we demonstrate proof-of-concept in situ crossover sensing and characterize the effects of electrolyte composition on this crossover. In this way, real-time tracing of redoxmers in a flow cell is demonstrated, paving the way to include still more self-reporting functions into the redoxmers.

25 ENERGY STORAGE↗

Developing Fluorescence-Based Sensors to Support Rare Earth Element Separation

Rare earth elements (REEs) are essential to most renewable energy technologies. Unfortunately, as we transition to sustainable energy production, the demand for REEs is rapidly growing well beyond current rates of production. As a result, novel means of efficient, scalable, and easily adaptable methods for processing primary and recycle feedstocks are needed. Development and integration of sensors for highly selective in-line monitoring can support more efficient design and testing of such novel separation processes, as well as more cost-effective deployment of those separation flowsheets. Work here will explore the application of fluorescence spectroscopy, a highly sensitive and selective technique, to quantify multiple lanthanides in complex mixtures including known interferents or quenching agents. Results include identification of the optimal excitation wavelength and the limit of detection of various rare earth elements as well as the performance of data-science-based quantification approaches in streams where “unknowns” are present. Overall, the data science tools in conjunction with optical sensor data were able to quantify analytes in the presence of other lanthanides which can be anticipated in the actual industrial stream. Here we include characterization of lanthanides in a microfluidic device similar to those used in new process development. This study demonstrates the capability of utilizing fluorescence spectroscopy to quantify analytes in a complicated solution matrix, suggesting this is a successful approach for in-line monitoring to optimize the separation efficiency in an industrial stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗