Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Subcriticality Measurements with HEU (93.2) Metal Annular Storage Castings

These carefully performed and documented measurements with unreflected and unmoderated highly enriched uranium (HEU) castings can be used to benchmark calculational methods for the time decay of the fission chain multiplication process as measured with small (1 x 1 x 6 in. thick plastic scintillators with 1/4-in.-thick lead on all detector surfaces) detectors adjacent to the tightly fitting stainless steel cans that contained the HEU ({approx}93 wt%) metal. Prompt time decay measurements were performed stimulating the fission chain multiplication process with a timed, tagged Cf spontaneous fission source that emitted fission-spectrum neutrons and a time and directionally tagged 14.1-MeV neutrons from the DT reaction in a steady state generator with an embedded alpha detector. Time decay measurements were performed with HEU masses varying from 18 to 90 kg for a wide variety of source-detector-casting configurations. The use of a DT generator provided no addition information about the fission chain behavior beyond that provided by a time-tagged Cf spontaneous fission source. The main quantities obtained in the measurements were (1) the time distribution of the counts in a detector after a neutron fission in the Cf source or after the alpha detection coincident with the emission of a neutron from the DT generator (the equivalent of a pulsed neutron measurement with a randomly pulsed source) and (2) the time distribution of counts in one detector after a count in another detector (the equivalent of a two-detector Rossi-alpha measurement). Monte Carlo calculations using the MCNP-PoliMi coupled gamma-neutron transport code generally agreed with the measurement results except for some differences early in the fission chain decay process. The measurements that were performed with the HEU about 1 m above the floor were considerably affected by room return neutrons at times as early as 100 ns, and at times after 300 ns, a major portion of the time response was associated with the interaction of the HEU assemblies with the floor. This room-return effect increased with the size of the assembly because the larger assemblies subtend a larger solid angle to a neutron returning from the floor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders - Chicago, IL and Devens, MA

TO4 Task 3.1 - K Hovnanian Chicago, IL DOE Challenge Home Program Certified Home Constructed and Verified Specifications DOE Challenge Home Building envelope Ceiling R-49 blown fiberglass, Grade I Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I and 1"" R-5 extruded polystyrene (XPS) insulating sheathing Frame Floors R-38 blown fiberglass, Grade I Basement Walls R-19 fiberglass batts draped full height, Grade I Basement Slab uninsulated Windows Above Grade: ENERGY STAR certified, U=0.29, SHGC=0.28 Basement: Non ENERGY STAR certified, U=0.29, SHGC=0.24 Infiltration 2 ACH 50 Mechanical systems Heat 95% AFUE sealed combustion natural gas furnace in conditioned space Goodman GMH950703BXAF Cooling 13 SEER split system Goodman GSX130301BC DHW AO Smith Vertex 100 0.96 EF natural gas tank water heater in 2nd floor utility closet Hot Water Distribution Redesigned trunk and branch Compliant with EPA WaterSense Efficient Distribution Requirements Ducts Located 100% in conditioned space via floor joists leak free to outside (5% or less) Ventilation Central Fan Integrated Supply (CFIS) ventilation with 6"" insulated outside air duct Fan Controller: Air Cycler FRV, with 6"" motorized damper 50 CFM outside air flow, 33% duty cycle (10 minutes on, 20 minutes off); ASHRAE 62.2-2010 compliance via an exhaust fan - Panasonic FV-08VQ5 WhisperCeiling Rerturn Pathways Active Return at Master Bedroom Transfer Grilles in Secondary Bedrooms Appliances, Lighting, MELs Lights 80% ENERGY STAR certified CFL Appliances ENERGY STAR certified refrigerator, dishwasher, and clothes washer; Natural gas range/oven and clothes dryer" STRUCTURE - Test House Lot 145 - 2013 DOE Challenge Test House Task 3.1 Bolingbrook, IL 60490 House is constructed and is DOE Challenge Verified by Don Nelson, a local rater. The purpose of this project was to evaluate integrated packages of advanced measures in individual test homes to assess their performance with respect to Building America Program goals, specifically compliance with the DOE Challenge Home Program. To that end, Building Science Corporation (BSC) consulted on the construction of five test houses by three cold climate production builders in three separate U.S. cities. (1) K. Hovnanian Homes, Chicago, Illinois (2) David Weekley Homes, Denver, Colorado (3) Transformations, Inc., Devens, Massachusetts. Overall, the builders have concluded that the energy related upgrades (either through the prescriptive or performance path) represent reasonable upgrades. The builders commented that while not every improvement in specification was cost effective (as in a reasonable payback period), many were improvements that could improve the marketability of the homes and serve to attract more energy efficiency discerning prospective homeowners. However, the builders did express reservations about the associated checklists and added certifications. An increase in administrative time was observed with all builders. The checklists and certifications also inherently increase cost due to: (1) Adding services to the scope of work for various trades, such as HERS Rater and heating, ventilation, and air conditioning contractor. (2) Increased material costs related to the checklists, especially the U.S. Environmental Protection Agency Indoor airPLUS and WaterSense Efficient Hot Water Distribution requirement. Ceiling - 18" cellulose Walls - 12" open cell spray foam in double stud walls Foundation - R-10 under slab, 3 1/2" closed-cell spray foam at walls Windows - Harvey U=0.20, SHGC=0.22 Infiltration - 1.0 sq in per 100 sq ft Heating - Mini split heat pump, 10.6 HSPF, 23 SEER Cooling - Mini split heat pump, 10.6 HSPF, 23 SEER DHW - 0.97 EF instantaneous propane water heater Ventilation - bathroom exhaust fans as basic option, HRV upgrade option Adams Circle Devens MA 01434 Cavite Street Devens, MA 01434

Array↗

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

Modification of one man life raft

A one man inflatable life raft is described. The raft has an inflatable tube perimetrically bounding the occupant receiving space with a flexible floor member. A zippered opening in the floor allows entry and facilitates the use of a constant diameter tube. An airtight fabric bulkhead divides the peripheral tube longitudinally into inflatable tube sections, where if either tube section were punctured, the bulkhead would move into the punctured section to substitute for the punctured wall portion and maintain the inflatable volume of the tube. The floor member is attached to the central portion of the tube wall so that either side of the raft can be the up side.

Soter, E. J.↗

Experimental studies for determining human discomfort response to vertical sinusoidal vibration

A study was conducted to investigate several problems related to methodology and design of experiments to obtain human comfort response to vertical sinusoidal vibration. Specifically, the studies were directed to the determination of (1) the adequacy of frequency averaging of vibration data to obtain discomfort predictors, (2) the effect of practice on subject ratings, (3) the effect of the demographic factors of age, sex, and weight, and (4) the relative importance of seat and floor vibrations in the determination of measurement and criteria specification location. Results indicate that accurate prediction of discomfort requires knowledge of both the acceleration level and frequency content of the vibration stimuli. More importantly, the prediction of discomfort was shown to be equally good based upon either floor accelerations or seat accelerations. Furthermore, it was demonstrated that the discomfort levels in different seats resulting from similar vibratory imputs were equal. Therefore, it was recommended that criteria specifications and acceleration measurements be made at the floor location. The results also indicated that practice did not systematically influence discomfort responses nor did the demographic factors of age, weight, and sex contribute to the discomfort response variation.

Dempsey, T. K.↗

Concorde noise-induced building vibrations, Sully Plantation - Report no. 2, Chantilly, Virginia

Noise-induced building vibrations associated with Concorde operations were studied. The approach is to record the levels of induced vibrations and associated indoor/outdoor noise levels in selected homes, historic and other buildings near Dulles International Airport. Representative data are presented which were recorded at Sully Plantation, Chantilly, Virginia during the periods of May 20 through May 28, 1976, and June 14 through June 17, 1976. Recorded data provide relationships between the vibration levels of windows, walls, floors, and the noise associated with Concorde operations, other aircraft, and nonaircraft events. The results presented are drawn from the combined May-June data base which is considerably larger than the May data base covered. The levels of window, wall and floor vibratory response resulting from Concorde operations are higher than the vibratory levels associated with conventional aircraft. Furthermore, the vibratory responses of the windows are considerably higher than those of the walls and floors. The window response is higher for aircraft than recorded nonaircraft events and exhibits a linear response relationship with the overall sound pressure level. For a given sound pressure level, the Concorde may cause more vibration than a conventional aircraft due to spectral or other differences. However, the responses associated with Concorde appear to be much more dependent upon sound pressure level than spectral or other characteristics of the noise.

Source record↗

Concorde noise-induced building vibrations: John F. Kennedy International Airport

Outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at eight homesites and a school along with the associated vibration levels in the walls, windows, and floors at these test sites. Limited subjective tests were conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise. Both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Seated subjects more readily detected floor vibrations than wall or window vibrations. Aircraft noise generally caused more window vibrations than common nonaircraft events such as walking and closing doors. Nonaircraft events and aircraft flyovers resulted in comparable wall vibration levels, while floor vibrations were generally greater for nonaircraft events than for aircraft flyovers. The relationship between structural vibration and aircraft noise is linear, with vibration levels being accurately predicted from overall sound pressure levels (OASPL) measured near the structure. Relatively high levels of structural vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde-source characteristics.

Mayes, W. H.↗

Geology of the Valles Marineris - First Analysis of Imaging from the Viking 1 Orbiter Primary Mission

The Valles Marineris on the planet Mars constitute an enormous group of steep-walled equatorial canyons extending over an area more than 4000 km long and up to 700 km wide. An overview of Valles Marineris is provided, taking into account canyon system subdivisions, imaging and topographic data, Noctis Labyrinthus, western troughs, central troughs, east central troughs, and eastern canyons. Aspects of canyon wall and canyon floor morphology are discussed, giving attention to erosional features, layered rocks in canyon walls, tectonic features, plains, landslide deposits, hilly terrain, fractured floor, and floor plateaus and ridges. Upland pits and closed depressions in the canyons are considered along with regional tectonics and regional erosional styles.

Blasius, K. R.↗

Geologic application of thermal inertia imaging using HCMM data

The author has identified the following significant results. The day infrared and visible HCMM satellite data for Death Valley taken on 31 May 1978 were compared with aircraft data of the same area taken in March of the same year. In the visible image, it is possible to note the drying of the valley floor during the two month period between acquisition of the two data sets. On the IR image however, the valley floor remains cool, probably indicating that while the standing water has disappeared, the floor is still moist.

Paley, H. N.↗

New morphometric data for fresh lunar craters

Morphometric relations have been determined for 2598 fresh craters on the lunar nearside using data given in the catalog of Wood and Andersson (1978). For each of five principal morphological types, typified by Albategnius C, Biot, Sosigenes, Triesnecker, and Tycho, statistical relations are documented for the following: crater diameter and depth; floor diameter and crater diameter; central peak height and crater diameter; average wall slope and crater depth; central peak occurrence and crater diameter; occurrence of scallops or terraces and crater diameter. The first four relations generally confirm the conclusions of Pike (1977), but the last two differ from results reported by Smith and Sanchez (1973). Small (diameter less than 20 km) flat-floored craters formed in mare terrains are as much as 10% deeper than those formed in the highlands, and the depths of small bowl-shaped craters reflect even greater dependence on terrain. Larger, scalloped-walled craters are deeper in highland terrain than on the maria. Although wall failure does not occur until the crater diameter reaches 13 km, central peaks are found in flat floor craters as small as 2 km.

Wood, C. A.↗

Central peaks in lunar craters - Morphology and morphometry

Fresh lunar craters with diameters from 17 to 175 km are found to display a linear relationship between the central peak morphology and morphometry and such critical crater parameters as rim crest diameter, floor diameter, and substrate. Some other previously established linear relationships have been cited as evidence that floor diameter, peak height, and peak ring diameter are related to the kinetic energy of impact. The two new relations derived in the present work would therefore indicate that the central peaks, too, are related to the kinetic energy of impact, and probably begin to form early in the cratering event as suggested by Milton and Roddy (1972) and Head (1978). There seems to be no obvious reason to expect such linear relationships between central peak diameter and rim crest and floor diameter if the peaks are formed by gravity induced failure of the transient cavity, as suggested by Dence et al. (1968).

Hale, W.↗

Landslides in Valles Marineris, Mars

The morphology of the landslides in the Martian equatorial troughs, the geologic structure of the troughs, the time of emplacement, the similarity to terrestrial landslides, and the origin and mechanism of transport are analyzed. About 35 large landslides well-resolved on Viking images were examined, and it is found that the major landslides cover 31,000 sq km of the trough floors, and individual slides range in area from 40 to 7000 sq km. The morphologic variations of the landslides can be attributed mainly to their degree of confinement on trough floors. Many prominent landslides appear to be of similar age and were emplaced after a major faulting that dropped the trough floors. Most sliding occurred after the created scarps were dissected into spurs, gullies, and tributary canyons. Emplacement of the landslides approximately coincided with a late episode of major eruptive activity of the Tharsis volcanoes, and it is suggested that the slides may have originated as gigantic mudflows with slump blocks at their heads. The large size of many landslides is due to the fault scarps as high as 7 km on which they formed in the absence of vigorous fluvial erosion. The landslides suggest that Mars is earthlike in some respects, which may be important for further evaluations.

Lucchitta, B. K.↗

Morphology of fresh craters on Ganymede and the origin of pedestal craters

Properties of the planetary surface and subsurface can affect the morphology of impact craters. A mechanism was proposed to explain pedestal craters and domed floors within fresh craters on Ganymede. Voyager 1 and 2 images with resolutions = to or 3.2 km/lp were examined and 523 fresh craters were identified. For each crater, the rim and ejecta diameters were measured, and the crater was characterized by ejecta class(es), interior features, floor morphology and target terrain. Of the craters examined, 97 show moderate to prominent doming of the crater floor; 340 craters have continuous ejecta which terminates in a scarp pedestal craters, of which 86 (25%) have a high albedo diffuse deposit beyond the pedestal.

Horner, V. M.↗

Analysis of a transport fuselage section drop test

Transport fuselage section drop tests provided useful information about the crash behavior of metal aircraft in preparation for a full-scale Boeing 720 controlled impact demonstration (CID). The fuselage sections have also provided an operational test environment for the data acquisition system designed for the CID test, and data for analysis and correlation with the DYCAST nonlinear finite-element program. The correlation of the DYCAST section model predictions was quite good for the total fuselage crushing deflection (22 to 24 inches predicted versus 24 to 26 inches measured), floor deformation, and accelerations for the floor and fuselage. The DYCAST seat and occupant model was adequate to approximate dynamic loading to the floor, but a more sophisticated model would be required for good correlation with dummy accelerations. Although a full-section model using only finite elements for the subfloor was desirable, constraints of time and computer resources limited the finite-element subfloor model to a two-frame model. Results from the two-frame model indicate that DYCAST can provide excellent correlation with experimental crash behavior of fuselage structure with a minimum of empirical force-deflection data representing structure in the analytical model.

E. L. Fasanella↗

Submarine Volcanic Eruptions and Potential Analogs for Venus

As part of an analysis program to better understand the diversity of volcanic processes on the terrestrial planets, an investigation of the volcanic landforms which exist on the Earth's ocean floor was initiated. In part, this analysis is focused toward gaining a better understanding of submarine volcanic landforms in their own right, but also it is hoped that these features may show similarities to volcanic landforms on Venus, due to the high ambient water (Earth) and atmospheric (Venus) pressures. A series of numerical modelling experiments was performed to investigate the relative importance of such attributes as water pressure and temperature on the eruption process, and to determine the rate of cooling and emplacement of lava flows in the submarine environment. Investigations to date show that the confining water pressure and the buoyancy effects of the surrounding water significantly affect the styles of volcanism on the ocean floor. In the case of Venusian volcanism, confining pressures will not be as great as that found at the ocean's abyssal plains, but nevertheless the general trend toward reducing magma vesiculation will hold true for Venus as well as the ocean floor. Furthermore, other analogs may also be found between submarine volcanism and Venusian activity.

Wilson, L.↗

Analysis of a method for precisely relating a seafloor point to a distant point on land

A study of the environmental constraints and engineering aspects of the acoustic portion of a system for making geodetic ties between undersea reference points and others on land is described. Important areas in which to make such observations initially would be from the California mainland out to oceanic points seaward of the San Andreas fault, and across the Aleutian Trench. The overall approach would be to operate a GPS receiver in a relative positioning (interferometric) mode to provide the long range element of the baseline determination (10 to 1,000 km) and an array of precision sea floor acoustic transponders to link the locally moving sea surface GPS antenna location to a fixed sea floor point. Analyses of various environmental constrants (tides, waves, currents, sound velocity variations) lead to the conclusion that, if one uses a properly designed transponder having a remotely controllable precise retransmission time delay, and is careful with regard to methods for installing these on the sea floor, one should, in many ocean locations, be able to achieve sub-decimeter overall system accuracy. Achievements of cm accuracy or better will require additional understanding of time and space scales of variation of sound velocity structure in the ocean at relevant locations.

Spiess, F. N.↗

Structural loads preliminary results

From a total of 351 instrumentation channels, 341 channels (97%) were in operation during the initial impact of the airplane. Both NASA seats, the energy absorbing seat and the standard seat, maintained their integrity during the impact. The floor accelerations at the seat locations were lower than the accelerations required for the energy absorbers to stroke; consequently, the energy absorbing seat did not stroke. The two seats remained firm in place during the crash and no seat attachment failures were observed. Due to the low accelerations experienced during the crash, both seats performed as standard seats. In the airplane structure, the accelerations were higher at both the point of impact in the left wing and at the forward end of the fuselage. The accelerations on the floor were higher toward the front than toward the rear and the floor accelerations on the left side were higher than on the right side at the front of the fuselage, but toward the rear they evened out.

Alfaro-Bou, E.↗

Propeller aircraft interior noise model: User's manual for computer program

A computer program entitled PAIN (Propeller Aircraft Interior Noise) has been developed to permit calculation of the sound levels in the cabin of a propeller-driven airplane. The fuselage is modeled as a cylinder with a structurally integral floor, the cabin sidewall and floor being stiffened by ring frames, stringers and floor beams of arbitrary configurations. The cabin interior is covered with acoustic treatment and trim. The propeller noise consists of a series of tones at harmonics of the blade passage frequency. Input data required by the program include the mechanical and acoustical properties of the fuselage structure and sidewall trim. Also, the precise propeller noise signature must be defined on a grid that lies in the fuselage skin. The propeller data are generated with a propeller noise prediction program such as the NASA Langley ANOPP program. The program PAIN permits the calculation of the space-average interior sound levels for the first ten harmonics of a propeller rotating alongside the fuselage. User instructions for PAIN are given in the report. Development of the analytical model is presented in NASA CR 3813.

Wilby, E. G.↗