Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fiber surfaces”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

6D anomaly-free matter spectrum in F-theory on singular spaces

In this paper we study the 6d localized charged matter spectrum of F-theory directly on a singular elliptic Calabi-Yau 3-fold, i.e. without smoothing via resolution or deformation of the entire fibration. Given only the base surface, discriminant locus, and the SL(2, $\mathbb{Z}$) local system, we propose a general prescription for determining the charged matter spectrum localized at intersections of seven-branes, using the technology of string junctions. More precisely, at each codimension-2 collision of seven-branes, we determine the local seven-brane content and compute the number of massless string junctions modulo the action of the SL(2,$\mathbb{Z}$) monodromy. We find agreement with the predicted results from 6d anomaly cancellation in all cases considered. Examples include a generic Weierstrass model with arbitrary Kodaira fiber intersecting an I 1 , as well as cases with jointly charged matter localized at intersections of non-abelian seven-branes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Date Release Report for Large Surface Explosion Coupling Experiment (LSECE) Nevada National Security Site

The DTRA sponsored 2020-2022 Large Surface Explosion Coupling Experiment (LSECE) consists of two large ground surface chemical explosions, data collection, analysis and modeling carried out in 2020-2022. The LSECE chemical explosions were carried out at the site of prior NNSA sponsored buried chemical explosions that were part of the Source Physics Experiment (SPE) Phase II in Dry Alluvium Geology (DAG). This report described the data collected under LSECE that is being made publicly available. The prior buried explosion DAG data are described in a separate report (https://www.osti.gov/biblio/1825534) and are also publicly available. The LSECE explosions, data analysis and numerical modeling work sponsored by DTRA were intended to address three objectives: 1) Generate seismo-acoustic data to test and improve numerical models of explosion energy coupling in dry alluvium geology; 2) To improve seismo-acoustic yield estimation techniques as a function of depth and medium properties; 3) To study and improve acoustic propagation modeling under two different atmospheric conditions. The LSECE data that were collected have expanded the prior DAG buried explosion dataset to include surface chemical explosions recorded on a common set of seismo-acoustic stations. They have allowed a more detailed study of above and below surface seismo-acoustic energy coupling with applications to explosion monitoring and assessment. The two approximately 1-ton TNT equivalent yield LSECE explosions were detonated at different times of the day to explore the effects of the different atmospheric conditions. The first chemical explosion “Artemis” was conducted before dawn when temperature inversions were present. The second chemical explosion “Apollo” was conducted on a sunny afternoon when the temperature gradient was more linear. The LSECE chemical explosion data were also collected across a variety of different sensor types to allow evaluation of their effectiveness in recovering useful information. The LSECE instrumentation included fiber optic or Distributed Acoustic Sensing (DAS), a dense array or Large-N array of seismometers, borehole accelerometers, DAS and a velocity meter, airborne acoustic instruments and a variety of visual and remote sensing data.

58 GEOSCIENCES↗

Identification of Distribution of Elastic Constants of SiC/SiC Braided Tubes

There has been considerable interest in chemical vapor infiltration (CVI) manufactured silicon carbide fiber and silicon carbide matrix (SiCf/SiCm) composite tubes due to their superior mechanical properties. There are many parameters in the manufacturing of SiCf/SiCm composite tubes such as elastic constants of constituent SiC fiber and SiC matrix, braiding angle, porosity, and others whose values vary over a range. A sensitivity analysis will be carried out to determine the dominant parameters among the abovementioned ones. We intend to determine the variability in elastic constants of SiCf/SiCm composite tubes considering the variability in dominant parameters. A chosen number of combinations of dominant variables will be sampled through Latin hypercube sampling (LHS) method. The elastic constants of composite tube namely Young's moduli in circumferential and longitudinal direction, Poisson's ratio and shear modulus will be calculated at sampled points through finite element (FE) analysis. A polynomial response surface (PRS) will be built for each of the elastic constants to be used a surrogate to FE analysis. once the predictive accuracy of PRS is verified at the validation set of data points, the PRS will be invoked 105 times in Monte Carlo simulations (MCS). The variability can be calculated based on MCS-generated data which will be presented at the conference.

42 ENGINEERING↗

Water-soluble saponins accumulate in drought-stressed switchgrass and may inhibit yeast growth during bioethanol production

Abstract Background Developing economically viable pathways to produce renewable energy has become an important research theme in recent years. Lignocellulosic biomass is a promising feedstock that can be converted into second-generation biofuels and bioproducts. Global warming has adversely affected climate change causing many environmental changes that have impacted earth surface temperature and rainfall patterns. Recent research has shown that environmental growth conditions altered the composition of drought-stressed switchgrass and directly influenced the extent of biomass conversion to fuels by completely inhibiting yeast growth during fermentation. Our goal in this project was to find a way to overcome the microbial inhibition and characterize specific compounds that led to this inhibition. Additionally, we also determined if these microbial inhibitors were plant-generated compounds, by-products of the pretreatment process, or a combination of both. Results Switchgrass harvested in drought (2012) and non-drought (2010) years were pretreated using Ammonia Fiber Expansion (AFEX). Untreated and AFEX processed samples were then extracted using solvents (i.e., water, ethanol, and ethyl acetate) to selectively remove potential inhibitory compounds and determine whether pretreatment affects the inhibition. High solids loading enzymatic hydrolysis was performed on all samples, followed by fermentation using engineered Saccharomyces cerevisiae . Fermentation rate, cell growth, sugar consumption, and ethanol production were used to evaluate fermentation performance. We found that water extraction of drought-year switchgrass before AFEX pretreatment reduced the inhibition of yeast fermentation. The extracts were analyzed using liquid chromatography–mass spectrometry (LC–MS) to detect compounds enriched in the extracted fractions. Saponins, a class of plant-generated triterpene or steroidal glycosides, were found to be significantly more abundant in the water extracts from drought-year (inhibitory) switchgrass. The inhibitory nature of the saponins in switchgrass hydrolysate was validated by spiking commercially available saponin standard (protodioscin) in non-inhibitory switchgrass hydrolysate harvested in normal year. Conclusions Adding a water extraction step prior to AFEX-pretreatment of drought-stressed switchgrass effectively overcame inhibition of yeast growth during bioethanol production. Saponins appear to be generated by the plant as a response to drought as they were significantly more abundant in the drought-stressed switchgrass water extracts and may contribute toward yeast inhibition in drought-stressed switchgrass hydrolysates.

59 BASIC BIOLOGICAL SCIENCES↗

Experiments at TA-55 have used optical pyrometry to measure temperatures of shocked plutonium on the 40mm gun

Researchers at LANL, along with collaborators from MSTS, have worked for more than a decade to develop and implement an optical pyrometry method to measure the temperature of metals shocked to the high pressures and temperatures. Because traditional shock wave measurements only provide information on the mechanical state of the material, temperature measurements are required to validate and improve equation-of-state (EOS) models for materials. The conditions sampled are complex; commenserate with those found in planetary impacts, and accressed by conventional and nuclear weapons. Optical pyrometry is currently the best available method for inferring the temperature of shocked metals, by careful measurement of the calibrated radiance emitted by a surface at finite temperature. These measurements are difficult often complicated by the short time scales associated with shock wave experiments (<1 µs) coupled with the many sources of non-thermal light (impact flash, fracture light, etc.) that pollutes the radiant light measured from the sample.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pulsed Infrared Thermography Nondestructive Imaging of SiC-SiC f Composite Cladding Architectures; Understanding the Performance of SiC-SiC f Composite Cladding Architectures with Cr Coating in Normal Operating and Accident Conditions in LWRs and Advanced Reactors

SiC-SiC f composites, consisting of silicon carbide fibers embedded in a silicon carbide matrix, are advanced materials with high thermal conductivity, temperature stability, and resistance to radiation damage. Traditional methods for quality control of fabricated SiC-SiC f composites involve nondestructive evaluation (NDE) with X-ray computed tomography (XCT). However, XCT imaging of typical SiC-SiC f structures for cladding applications can involve several hours. In this project, we investigate an alternative approach to NDE of SiC-SiC f composites that involves rapid (on the order of seconds) imaging with Pulsed infrared thermography (PIT). PIT images of a planar SiC-SiC f specimen show the structure of the surface monolith layer and internal SiC f structures. The capability of PIT imaging in visualizing SiC f structures is qualitatively confirmed by observing similarity in the PIT and X-ray transmission images of the same specimen. Computer vision analysis of defects in the PIT image of the monolith was performed with thresholding followed by topological structural analysis that computed geometric descriptors, including major/minor axes of fitted ellipses, area, perimeter, Feret diameter, circularity, roundness, and solidity.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spatiotemporal flame propagations, combustion and solid particle emissions from lean and stoichiometric gasoline direct injection engine operation

Increased particle number and mass emissions in gasoline direct injection (GDI) engines should require to investigate in-cylinder flame and combustion characteristics associated with primary source of particle emissions. In this article, in-cylinder spatiotemporal flame luminosity is quantitatively characterized to features combustion process and solid particle emissions from a GDI engine operating in two lean and one stoichiometric modes. Low- and high-steady state operating points were used to compare combustion strategies on flame development and emission characteristics. A fiber-optic sensor composed of eight measurement channels detected the flame front and the direction of the flame propagation in the combustion chamber. Solid particle emissions in the exhaust were measured using an engine exhaust particle sizer and a micro soot sensor. Results of the experiments showed that two lean combustion modes by injection strategies resulted in distinct combustion and flame development. Lean combustion modes generated high diffusion flame by burning stratified rich-mixture. Although the lean cases resulted in strong diffusion flames, the lean-homogeneous produced similar particle size distributions with the stoichiometric mode with high ash particles. Piston pool fires on the piston surface in the lean-stratified mode induced a large accumulation mode with high particle mass concentrations.

42 ENGINEERING↗

Luminescent Zn 2 GeO 4 :Mn 2+ Nanoparticles with High Quantum Yield for Salivary Protein Detection

Zinc germanate doped with Mn 2+ (Zn 2 GeO 4 :Mn 2+ ) is known to be a green luminescence phosphor with many applications in biosensing and bioimaging. This study presents a simple method for creating small size Zn 2 GeO 4 :Mn 2+ nanoparticles using a combination of the coprecipitation–molten salt synthesis method. These nanoparticles exhibit bright green luminescence under UV excitation. After surface functionalization, these nanoparticles were then used to develop a fluorescence resonance energy transfer (FRET)-based immunoassay. This immunoassay shows a detection range of 5–20 ng/mL of C-reactive protein (CRP), which suggests its potential for simple solution CRP detection and broader applications in protein biosensing.

biosensing↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Designing Track for Electrospinning Unit and Cost-Effective Laser Scanning System

Nanofibers are produced in the Targeted Systems Department (TSD) by applying a large voltage to the nanofiber fluid and the collection apparatus known as the electrospinner. The fiber is then shot out of nozzles and collected onto the electrospinner into a nanofiber mat. The problem is that since the nozzle heads are stationary, there is non-uniform deposition of nanofiber on the collection drum leading to variation in thickness of the produced nanofiber mat. To mitigate this issue, a reciprocating mechanism is designed to move the nozzle along the drum collector along with the ability to vary its stroke length. This design was realized using Siemens NX and several parts were printed using a 3D printer, but is, as of writing, untested. Second project involved providing an alternative method to scan a large sample that had undergone certain surface deformation by beam interaction and detect out of plane deformation such as micro-scale swelling and surface roughness. Systems to carry out this scanning already exist; however, they are expensive and produce many files that need to be stitched together and are cumbersome to deal with. The solution is to create a scanning system using an already purchased scanning laser and linear stage motor. The laser and stage motor were combined to produce length results that aligned with a digital microscope but differing height results.

Ruffolo, Leopoldo↗

Designing a track for an electrospinning unit and cost-effective laser scanning system

Nanofibers are produced in the Targeted Systems Department (TSD) by applying a large voltage to the nanofiber fluid and the collection apparatus known as the electrospinner. The fiber is then shot out of nozzles and collected onto the electrospinner into a nanofiber mat. The problem is that since the nozzle heads are stationary, there is non-uniform deposition of nanofiber on the collection drum leading to variation in thickness of the produced nanofiber mat. To mitigate this issue, a reciprocating mechanism is designed to move the nozzle along the drum collector along with the ability to vary its stroke length. This design was realized using Siemens NX and several parts were printed using a 3D printer, but is, as of writing, untested. Second project involved providing an alternative method to scan a large sample that had undergone certain surface deformation by beam interaction and detect out of plane deformation such as micro-scale swelling and surface roughness. Systems to carry out this scanning already exist; however, they are expensive and produce many files that need to be stitched together and are cumbersome to deal with. The solution is to create a scanning system using an already purchased scanning laser and linear stage motor. The laser and stage motor were combined to produce length results that aligned with a digital microscope but differing height results.

Ruffolo, Leopoldo↗

Design and Implementation of Surface Eroding Thermocouples for Stage-One Modular Divertor Integration at the DIII-D Tokamak

The DIII-D has upgraded its upper divertor to a modular system using copper alloy pedestals to alter the divertor geometry without changing the vessel structure. Six new graphite tiles were designed for the shape and volume rise (SVR) divertor. Here, these new SVR tiles facilitated the formation of a poloidal array of 27 surface eroding thermocouples (SETCs) in the upper divertor region. At one location, a specialized recessed SETC, paired with a standard flush SETC, was installed in one of the ceiling tiles to provide comprehensive heat flux measurements, distinguishing between charged and noncharged particle contributions. Upgrades were made to the SETC system in the small-angle slot (SAS) divertor to improve overall performance. These upgrades included optimizing the feedthrough system to double the thermocouple cable capacity and reallocating cables from the SAS area to the SVR divertor. A compact isolation amplifier system with a fixed gain of 41 was employed to improve the signal level and minimize interference. Additionally, two analog-to-analog fiber systems were implemented for transmitting thermocouple signals over a single fiber, significantly reducing both noise levels and costs. The newly installed SETCs in the SVR divertor successfully completed initial commissioning testing. The SETCs captured the in-out asymmetry in the power distribution between the inner and outer strike points and demonstrated the dependency of the heat flux profile on the outer strike point location. During divertor detachment, heat flux mitigation was noted at the outer strike point location, while significant heat flux contributions from neutral particles were measured in the SVR divertor.

Divertor↗

Multi-cell, triple pane, vacuum insulated glazing

A novel Triple Pane Vacuum Insulated Glazing (TPVIG) architecture consisting of three panes of glass separated by two offset grids is described. The grids are made of frit-coated fibers fused with the glass panes in a vacuum to create many independent hermetic cells. Unlike traditional VIGs, which are separated by support pillars, these cells significantly increase the redundancy in sealing, and the additional bonds formed by the grid lines reduce the stresses on the edge bonds thereby increasing VIG reliability. A numerical thermal analysis was conducted to determine the thermal performance of the VIG and suggested U-values below 0.5 W/m 2 -K (greater than R=11.4 hr-ft 2 -°F/Btu) can be obtained. A prototype of the VIG unit consisting of three glass panes (5.7 mm, 1.1 mm and 5.7 mm thick with low-e coating on two surfaces) was fabricated and tested for thermal performance using the hot box method. The experimental center of glass U-value for the VIG was found to be 0.42 W/m 2 K (R=13.2 hr-ft 2 -°F/Btu). Furthermore, this U-value is about four times lower than a typical Argon filled double pane window.

14 SOLAR ENERGY↗

Proliferated Resilient Economical Half-Meter Aperture Space Telescopes (PREEMPT)

The PREEMPT LDRD was motivated by a major national need for better space-based imaging systems that are both high performing and affordable for the US Government. Current optical payloads for intelligence, surveillance and reconnaissance (ISR) and space domain awareness (SDA) missions can cost hundreds of millions of dollars and take years to develop, which makes it difficult to build the large constellations required for persistent, world-wide coverage. To address this, the team aimed to advance a different kind of large-aperture (>25 cm) telescope, called a monolithic telescope, in which key optical surfaces are built into a single piece of fused silica. This design greatly reduces payload and spacecraft complexity, the need for precision focus actuators, improves mechanical and thermal robustness, and lowers cost when compared with traditional Cassegrain telescopes that rely on many precisely aligned components. The project focused on five primary thrusts. The first thrust was to advance the concept of a V10, 25 cm, monolithic telescope forward from optical design to flight-ready stage. This was accomplished in partnership with Optimax, who delivered the first test unit in the early stages of the LDRD. The team developed several technologies necessary for this optic to be integrated into a flight demonstration. These include carbon fiber housings, highly detailed structural and thermal models and stress-reducing elastic averaging Hirth groove designs. These technologies resulted in a successful maturation of the optic, which is now slated to fly in late 2026/early 2027 for a demonstration mission. The second thrust was to advance the manufacturability of these optics. In collaboration with NIF’s optical manufacturing shop, we reduced polishing time from 480 hours to 65 hours through the implementation of optimized processes and new tools. The NIF team utilized a conceptual V8 (18 cm) optic to demonstrate this optimization, though it can be applied to the rest of the monolithic optic portfolio. Third, the team developed the first conceptual V20 (50 cm) payload, which is slated to be the next generation of LLNL optical payload systems. A set of structural, dynamic and thermal simulations were performed to identify potential challenges in the future development of this payload. Early-stage simulations suggest the payload is feasible, though thermal management will be the key focus area to maintain optimal performance. Fourth, a non-linear model of Viton was developed, to further enhance the reliability of our structural and dynamic models for future payloads. Viton acts as the primary interface material between the optic and its housing. Lastly, the team focused on successfully displaying the feasibility of using additively manufactured metal composites for optical space payloads. The team successfully demonstrated layer by layer deposition of Al-SiC composites, which have highly tunable structural and coefficient of thermal expansion (CTE) properties. These are crucial for optical payloads because CTE mismatch is one of the causes for degraded optical performance for telescopes in orbit. Overall, the work showed that monolithic telescopes could become a practical, lower-cost path to high-resolution space imaging for both national security and scientific missions.

42 ENGINEERING↗

Mach Conference, 2022.

There has been considerable interest in chemical vapor infiltration (CVI) manufactured silicon carbide fiber and silicon carbide matrix (SiC/SiC) composite tubes due to their superior mechanical properties. The SiC/SiC tubes are known to remain stable even after prolonged exposure to radiation. However, there are many variables in the manufacturing of SiC/SiC composite tubes such as elastic constants of constituent SiC fiber and SiC matrix, braiding angle, porosity, and others whose values vary over a range. The intention is to identify the distribution of elastic constants of SiC/SiC tubes which would help model the performance of the novel cladding material. To do so, a sensitivity analysis will be carried out to determine the dominant variables that influence the elastic constants of SiC/SiC tubes. A chosen number of combinations of dominant variables will be sampled through the Latin hypercube sampling (LHS) method. The elastic constants of composite tube namely Young's moduli in the circumferential and longitudinal direction, Poisson's ratio, and shear modulus will be calculated at sampled points through finite element (FE) analysis. A polynomial response surface (PRS) will be built for each of the elastic constants to be used as a surrogate to FE analysis. Once the predictive accuracy of PRS is verified at the validation set of data points, the PRS will be invoked 105 times in Monte Carlo simulations (MCS). The uncertainty can be quantified by calculating the coefficient of variation (CV) based on MCS-generated data which will be presented at the conference.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗