Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “false positive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

MILLIONS OF MULTIPLES: DETECTING AND CHARACTERIZING CLOSE-SEPARATION BINARY SYSTEMS IN SYNOPTIC SKY SURVEYS

The direct detection of binary systems in wide-field surveys is limited by the size of the stars' point-spread functions (PSFs). A search for elongated objects can find closer companions, but is limited by the precision to which the PSF shape can be calibrated for individual stars. Based on a technique from weak-lensing analysis, we have developed the BinaryFinder algorithm to search for close binaries by using precision measurements of PSF ellipticity across wide-field survey images. We show that the algorithm is capable of reliably detecting binary systems down to Almost-Equal-To 1/5 of the seeing limit, and can directly measure the systems' position angles, separations, and contrast ratios. To verify the algorithm's performance we evaluated 100,000 objects in Palomar Transient Factory (PTF) wide-field-survey data for signs of binarity, and then used the Robo-AO robotic laser adaptive optics system to verify the parameters of 44 high-confidence targets. We show that BinaryFinder correctly predicts the presence of close companions with a <11% false-positive rate, measures the detected binaries' position angles within 1 Degree-Sign to 4 Degree-Sign (depending on signal-to-noise ratio and separation), and separations within 25%, and weakly constrains their contrast ratios. When applied to the full PTF data set, we estimate that BinaryFinder will discover and characterize {approx}450,000 physically associated binary systems with separations <2 arcsec and magnitudes brighter than m{sub R} = 18. New wide-field synoptic surveys with high sensitivity and sub-arcsecond angular resolution, such as LSST, will allow BinaryFinder to reliably detect millions of very faint binary systems with separations as small as 0.1 arcsec.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated aortic calcium scoring on low-dose chest computed tomography

Purpose: Thoracic computed tomography (CT) scans provide information about cardiovascular risk status. These scans are non-ECG synchronized, thus precise quantification of coronary calcifications is difficult. Aortic calcium scoring is less sensitive to cardiac motion, so it is an alternative to coronary calcium scoring as an indicator of cardiovascular risk. The authors developed and evaluated a computer-aided system for automatic detection and quantification of aortic calcifications in low-dose noncontrast-enhanced chest CT. Methods: The system was trained and tested on scans from participants of a lung cancer screening trial. A total of 433 low-dose, non-ECG-synchronized, noncontrast-enhanced 16 detector row examinations of the chest was randomly divided into 340 training and 93 test data sets. A first observer manually identified aortic calcifications on training and test scans. A second observer did the same on the test scans only. First, a multiatlas-based segmentation method was developed to delineate the aorta. Segmented volume was thresholded and potential calcifications (candidate objects) were extracted by three-dimensional connected component labeling. Due to image resolution and noise, in rare cases extracted candidate objects were connected to the spine. They were separated into a part outside and parts inside the aorta, and only the latter was further analyzed. All candidate objects were represented by 63 features describing their size, position, and texture. Subsequently, a two-stage classification with a selection of features and k-nearest neighbor classifiers was performed. Based on the detected aortic calcifications, total calcium volume score was determined for each subject. Results: The computer system correctly detected, on the average, 945 mm{sup 3} out of 965 mm{sup 3} (97.9%) calcified plaque volume in the aorta with an average of 64 mm{sup 3} of false positive volume per scan. Spearman rank correlation coefficient was {rho}=0.960 between the system and the first observer compared to {rho}=0.961 between the two observers. Conclusions: Automatic calcium scoring in the aorta thus appears feasible with good correlation between manual and automatic scoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of False Data Injection Attacks in Battery Stacks Using Input Noise-Aware Nonlinear State Estimation and Cumulative Sum Algorithms

Grid-scale battery energy storage systems (BESSs) are vulnerable to false data injection attacks (FDIAs), which could be used to disrupt state of charge (SoC) estimation. Inaccurate SoC estimation has negative impacts on system availability, reliability, safety, and the cost of operation. In this article a combination of a Cumulative Sum (CUSUM) algorithm and an improved input noise-aware extended Kalman filter (INAEKF) is proposed for the detection and identification of FDIAs in the voltage and current sensors of a battery stack. The series-connected stack is represented by equivalent circuit models, the SoC is modeled with a charge reservoir model and the states are estimated using the INAEKF. Further, the root mean squared error of the states’ estimation by the modified INAEKF was found to be superior to the traditional EKF. By employing the INAEKF, this article addresses the research gap that many state estimators make asymmetrical assumptions about the noise corrupting the system. Additionally, the INAEKF estimates the input allowing for the identification of FDIA, which many alternative methods are unable to achieve. The proposed algorithm was able to detect attacks in the voltage and current sensors in 99.16% of test cases, with no false positives. Utilizing the INAEKF compared to the standard EKF allowed for the identification of FDIA in the input of the system in 98.43% of test cases.

25 ENERGY STORAGE↗

Coregistration of Prechemotherapy PET-CT for Planning Pediatric Hodgkin's Disease Radiotherapy Significantly Diminishes Interobserver Variability of Clinical Target Volume Definition

Purpose: To assess the interobserver variability in clinical target volume (CTV) definitions when using registered {sup 18}F-labeled deoxyglucose positron emission tomography (FDG-PET-CT) versus side-by-side image sets in pediatric Hodgkin's disease (HD). Methods and Materials: Prechemotherapy FDG-PET-CT scans performed in the treatment position were acquired from 20 children (median age, 14 years old) with HD (stages 2A to 4B) and registered with postchemotherapy planning CT scans. The patients had a median age of 14 years and stages of disease ranging between 2A and 4B. Image sets were coregistered using a semiautomatic coregistration system. The biological target volume was defined on all the coregistered images as a guide to defining the initial site of involvement and to avoid false-positive or negative results. Five radiation oncologists independently defined the CTV for all 20 patients: once using separate FDG-PET-CT images as a guide (not registered) to define CTVa and once using the registered FDG-PET-CT data to define CTVb. The total volumes were compared, as well as their coefficients of variation (COV). To assess the interobserver variability, the percentages of intersection between contours drawn by all observers for each patient were calculated for CTVa and for CTVb. Results: The registration of a prechemotherapy FDG-PET-CT scan caused a change in the CTV for all patients. Comparing CTVa with CTVb showed that the mean CTVb increased in 14 patients (range, 0.61%-101.96%) and decreased in 6 patients (range, 2.97%-37.26%). The COV for CTVb significantly decreased for each patient; the mean COVs for CTVa and CTVb were 45% (21%-65%) and 32% (13%-57%), respectively (p = 0.0004). The percentage of intersection among all CTVbs for the five observers increased significantly by 89.77% (1.99%-256.41%) compared to that of CTVa (p = 0.0001). Conclusions: High observer variability can occur during CT-based definition of CTVs for children diagnosed with HD. Registration of FDG-PET and planning CT images resulted in significantly greater consistency of tumor volume definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prediction model of potential hepatocarcinogenicity of rat hepatocarcinogens using a large-scale toxicogenomics database

The present study was performed to develop a robust gene-based prediction model for early assessment of potential hepatocarcinogenicity of chemicals in rats by using our toxicogenomics database, TG-GATEs (Genomics-Assisted Toxicity Evaluation System developed by the Toxicogenomics Project in Japan). The positive training set consisted of high- or middle-dose groups that received 6 different non-genotoxic hepatocarcinogens during a 28-day period. The negative training set consisted of high- or middle-dose groups of 54 non-carcinogens. Support vector machine combined with wrapper-type gene selection algorithms was used for modeling. Consequently, our best classifier yielded prediction accuracies for hepatocarcinogenicity of 99% sensitivity and 97% specificity in the training data set, and false positive prediction was almost completely eliminated. Pathway analysis of feature genes revealed that the mitogen-activated protein kinase p38- and phosphatidylinositol-3-kinase-centered interactome and the v-myc myelocytomatosis viral oncogene homolog-centered interactome were the 2 most significant networks. The usefulness and robustness of our predictor were further confirmed in an independent validation data set obtained from the public database. Interestingly, similar positive predictions were obtained in several genotoxic hepatocarcinogens as well as non-genotoxic hepatocarcinogens. These results indicate that the expression profiles of our newly selected candidate biomarker genes might be common characteristics in the early stage of carcinogenesis for both genotoxic and non-genotoxic carcinogens in the rat liver. Our toxicogenomic model might be useful for the prospective screening of hepatocarcinogenicity of compounds and prioritization of compounds for carcinogenicity testing. - Highlights: >We developed a toxicogenomic model to predict hepatocarcinogenicity of chemicals. >The optimized model consisting of 9 probes had 99% sensitivity and 97% specificity. >This model enables us to detect genotoxic as well as non-genotoxic hepatocarcinogens.

60 APPLIED LIFE SCIENCES↗

Diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) versus endoscopic retrograde cholangiopancreatography (ERCP) in the pediatric population: a clinical effectiveness study

Purpose: To determine the diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) for detecting biliary and pancreatic abnormalities in a pediatric population, using endoscopic retrograde cholangiopancreatography (ERCP) as the reference standard. Materials and methods: Institutional review board approval with a waiver of informed consent was obtained for this retrospective investigation. Records from the Cincinnati Children’s Hospital Medical Center, Division of Gastroenterology and Department of Radiology were used to identify patients aged ≤ 18 years who had undergone both ERCP and MRCP within a 4-week interval between January 2013 and May 2017. Biliary and pancreatic duct findings were documented for each modality to determine the diagnostic performance of MRCP (with 95% confidence intervals), using ERCP as the reference standard. Results: 54 patients met inclusion criteria. Mean patient age at time of ERCP was 10.4 ± 4.9 years, and 25 (46%) were male. Mean interval between ERCP and MRCP was 11.2 ± 9.7 days. For detection of any abnormality (n = 99 ERCP findings), MRCP had a sensitivity of 76.8% (67.5–84.0%) and a positive predictive value (PPV) of 81.7% (72.7–88.3%). MRCP was 75.7% (59.9–86.6%) sensitive, with a PPV of 84.9% (69.1–93.4%) for biliary findings (n = 37) and 73.5% (59.7–83.8%) sensitive, with a PPV of 78.3% (64.4–87.7%) for pancreatic findings (n = 49). For pancreatobiliary abnormalities (n = 13), MRCP had a sensitivity of 92.3% (66.7–99.6%) and a PPV of 85.7% (60.1–97.5%). Conclusion: In clinical practice, MRCP is moderately sensitive for biliary and pancreatic abnormalities, with false-negative and false-positive examinations being relatively common.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring the potential of context-sensitive CADe in screening mammography

Purpose: Conventional computer-assisted detection (CADe) systems in screening mammography provide the same decision support to all users. The aim of this study was to investigate the potential of a context-sensitive CADe system which provides decision support guided by each user's focus of attention during visual search and reporting patterns for a specific case. Methods: An observer study for the detection of malignant masses in screening mammograms was conducted in which six radiologists evaluated 20 mammograms while wearing an eye-tracking device. Eye-position data and diagnostic decisions were collected for each radiologist and case they reviewed. These cases were subsequently analyzed with an in-house knowledge-based CADe system using two different modes: Conventional mode with a globally fixed decision threshold and context-sensitive mode with a location-variable decision threshold based on the radiologists' eye dwelling data and reporting information. Results: The CADe system operating in conventional mode had 85.7% per-image malignant mass sensitivity at 3.15 false positives per image (FPsI). The same system operating in context-sensitive mode provided personalized decision support at 85.7%-100% sensitivity and 0.35-0.40 FPsI to all six radiologists. Furthermore, context-sensitive CADe system could improve the radiologists' sensitivity and reduce their performance gap more effectively than conventional CADe. Conclusions: Context-sensitive CADe support shows promise in delineating and reducing the radiologists' perceptual and cognitive errors in the diagnostic interpretation of screening mammograms more effectively than conventional CADe.

60 APPLIED LIFE SCIENCES↗

Fast Semi-automated Filtration Method for Non-targeted LC-QTOF Data of Aged Nitroplasticizer Samples

A full dataset of aged nitroplasticizer (NP) is composed of more than 2000 unique mass-to-charges (m/z) when combining the non-targeted data obtained from both positive and negative electrospray ionization modes in time-of-flight mass spectrometry. Therefore, manual processing of these data often takes days, weeks, or even months to scrutinize for mechanistic insights. To effectively extract meaningful signals that represent vital degradation intermediates in the early NP degradation mechanism, a semi-automated postprocessing workflow for data filtering, tailored to the aging experiment of NP, has been developed. The automated portion of this workflow is written in a Python code (using pandas, numpy, and matplotlib libraries), which removes more than 65% of potential false signals within seconds via four threshold-based adjustable filters: signal sensitivity, coefficient of variation, number of measurements, and retention time variability. As for the manual portion, a pattern-based inspection method is employed to reduce another 23% or more false positives, which greatly simplifies data visualization and results in less than 3% of potential candidate m/z needing in-depth data interpretation. As a positive control, known compounds are verified. Using this semi-automated data reduction method, the amount of time required is reduced to a matter of hours for data filtering in the non-targeted datasets of aged NP, which saves more time and effort for compound identification.

36 MATERIALS SCIENCE↗

A Deep-Learning System for Fully-Automated Peripherally Inserted Central Catheter (PICC) Tip Detection

A peripherally inserted central catheter (PICC) is a thin catheter that is inserted via arm veins and threaded near the heart, providing intravenous access. The final catheter tip position is always confirmed on a chest radiograph (CXR) immediately after insertion since malpositioned PICCs can cause potentially life-threatening complications. Although radiologists interpret PICC tip location with high accuracy, delays in interpretation can be significant. In this study, we proposed a fully-automated, deep-learning system with a cascading segmentation AI system containing two fully convolutional neural networks for detecting a PICC line and its tip location. A preprocessing module performed image quality and dimension normalization, and a post-processing module found the PICC tip accurately by pruning false positives. Our best model, trained on 400 training cases and selectively tuned on 50 validation cases, obtained absolute distances from ground truth with a mean of 3.10 mm, a standard deviation of 2.03 mm, and a root mean squares error (RMSE) of 3.71 mm on 150 held-out test cases. This system could help speed confirmation of PICC position and further be generalized to include other types of vascular access and therapeutic support devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: Feasibility study

Purpose: In gynecological radiotherapy with high dose rate (HDR){sup 192}Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. Methods: The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron{sup 192}Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. Results: Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. Conclusions: In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computerized analysis of coronary artery disease: Performance evaluation of segmentation and tracking of coronary arteries in CT angiograms

Purpose: The authors are developing a computer-aided detection system to assist radiologists in analysis of coronary artery disease in coronary CT angiograms (cCTA). This study evaluated the accuracy of the authors’ coronary artery segmentation and tracking method which are the essential steps to define the search space for the detection of atherosclerotic plaques. Methods: The heart region in cCTA is segmented and the vascular structures are enhanced using the authors’ multiscale coronary artery response (MSCAR) method that performed 3D multiscale filtering and analysis of the eigenvalues of Hessian matrices. Starting from seed points at the origins of the left and right coronary arteries, a 3D rolling balloon region growing (RBG) method that adapts to the local vessel size segmented and tracked each of the coronary arteries and identifies the branches along the tracked vessels. The branches are queued and subsequently tracked until the queue is exhausted. With Institutional Review Board approval, 62 cCTA were collected retrospectively from the authors’ patient files. Three experienced cardiothoracic radiologists manually tracked and marked center points of the coronary arteries as reference standard following the 17-segment model that includes clinically significant coronary arteries. Two radiologists visually examined the computer-segmented vessels and marked the mistakenly tracked veins and noisy structures as false positives (FPs). For the 62 cases, the radiologists marked a total of 10191 center points on 865 visible coronary artery segments. Results: The computer-segmented vessels overlapped with 83.6% (8520/10191) of the center points. Relative to the 865 radiologist-marked segments, the sensitivity reached 91.9% (795/865) if a true positive is defined as a computer-segmented vessel that overlapped with at least 10% of the reference center points marked on the segment. When the overlap threshold is increased to 50% and 100%, the sensitivities were 86.2% and 53.4%, respectively. For the 62 test cases, a total of 55 FPs were identified by radiologist in 23 of the cases. Conclusions: The authors’ MSCAR-RBG method achieved high sensitivity for coronary artery segmentation and tracking. Studies are underway to further improve the accuracy for the arterial segments affected by motion artifacts, severe calcified and noncalcified soft plaques, and to reduce the false tracking of the veins and other noisy structures. Methods are also being developed to detect coronary artery disease along the tracked vessels.

60 APPLIED LIFE SCIENCES↗

SPOTTED STAR LIGHT CURVES WITH ENHANCED PRECISION

The nearly continuous timewise coverage of recent photometric surveys is free of the large gaps that compromise attempts to follow starspot growth and decay as well as motions, thereby giving incentive to improve computational precision for modeled spots. Due to the wide variety of star systems in the surveys, such improvement should apply to light/velocity curve models that accurately include all the main phenomena of close binaries and rotating single stars. The vector fractional area (VFA) algorithm that is introduced here represents surface elements by small sets of position vectors so as to allow accurate computation of circle-triangle overlap by spherical geometry. When computed by VFA, spots introduce essentially no noticeable scatter in light curves at the level of one part in 10,000. VFA has been put into the Wilson-Devinney light/velocity curve program and all logic and mathematics are given so as to facilitate entry into other such programs. Advantages of precise spot computation include improved statistics of spot motions and aging, reduced computation time (intrinsic precision relaxes needs for grid fineness), noise-free illustration of spot effects in figures, and help in guarding against false positives in exoplanet searches, where spots could approximately mimic transiting planets in unusual circumstances. A simple spot growth and decay template quantifies time profiles, and specifics of its utilization in differential corrections solutions are given. Computational strategies are discussed, the overall process is tested in simulations via solutions of synthetic light curve data, and essential simulation results are described. An efficient time smearing facility by Gaussian quadrature can deal with Kepler mission data that are in 30 minute time bins.

79 ASTRONOMY AND ASTROPHYSICS↗

Computer aided detection of surgical retained foreign object for prevention

Purpose: Surgical retained foreign objects (RFOs) have significant morbidity and mortality. They are associated with approximately $1.5 × 10{sup 9} annually in preventable medical costs. The detection accuracy of radiographs for RFOs is a mediocre 59%. The authors address the RFO problem with two complementary technologies: a three-dimensional (3D) gossypiboma micro tag, the μTag that improves the visibility of RFOs on radiographs, and a computer aided detection (CAD) system that detects the μTag. It is desirable for the CAD system to operate in a high specificity mode in the operating room (OR) and function as a first reader for the surgeon. This allows for fast point of care results and seamless workflow integration. The CAD system can also operate in a high sensitivity mode as a second reader for the radiologist to ensure the highest possible detection accuracy. Methods: The 3D geometry of the μTag produces a similar two dimensional (2D) depiction on radiographs regardless of its orientation in the human body and ensures accurate detection by a radiologist and the CAD. The authors created a data set of 1800 cadaver images with the 3D μTag and other common man-made surgical objects positioned randomly. A total of 1061 cadaver images contained a single μTag and the remaining 739 were without μTag. A radiologist marked the location of the μTag using an in-house developed graphical user interface. The data set was partitioned into three independent subsets: a training set, a validation set, and a test set, consisting of 540, 560, and 700 images, respectively. A CAD system with modules that included preprocessing μTag enhancement, labeling, segmentation, feature analysis, classification, and detection was developed. The CAD system was developed using the training and the validation sets. Results: On the training set, the CAD achieved 81.5% sensitivity with 0.014 false positives (FPs) per image in a high specificity mode for the surgeons in the OR and 96.1% sensitivity with 0.81 FPs per image in a high sensitivity mode for the radiologists. On the independent test set, the CAD achieved 79.5% sensitivity with 0.003 FPs per image in a high specificity mode for the surgeons and 90.2% sensitivity with 0.23 FPs per image in a high sensitivity mode for the radiologists. Conclusions: To the best of the authors’ knowledge, this is the first time a 3D μTag is used to produce a recognizable, substantially similar 2D projection on radiographs regardless of orientation in space. It is the first time a CAD system is used to search for man-made objects over anatomic background. The CAD system for the μTags achieved reasonable performance in both the high specificity and the high sensitivity modes.

60 APPLIED LIFE SCIENCES↗

Identification of characteristic oligonucleotides in the bacterial 16S ribosomal RNA sequence dataset

MOTIVATION: The phylogenetic structure of the bacterial world has been intensively studied by comparing sequences of 16S ribosomal RNA (16S rRNA). This database of sequences is now widely used to design probes for the detection of specific bacteria or groups of bacteria one at a time. The success of such methods reflects the fact that there are local sequence segments that are highly characteristic of particular organisms or groups of organisms. It is not clear, however, the extent to which such signature sequences exist in the 16S rRNA dataset. A better understanding of the numbers and distribution of highly informative oligonucleotide sequences may facilitate the design of hybridization arrays that can characterize the phylogenetic position of an unknown organism or serve as the basis for the development of novel approaches for use in bacterial identification. RESULTS: A computer-based algorithm that characterizes the extent to which any individual oligonucleotide sequence in 16S rRNA is characteristic of any particular bacterial grouping was developed. A measure of signature quality, Q(s), was formulated and subsequently calculated for every individual oligonucleotide sequence in the size range of 5-11 nucleotides and for 15mers with reference to each cluster and subcluster in a 929 organism representative phylogenetic tree. Subsequently, the perfect signature sequences were compared to the full set of 7322 sequences to see how common false positives were. The work completed here establishes beyond any doubt that highly characteristic oligonucleotides exist in the bacterial 16S rRNA sequence dataset in large numbers. Over 16,000 15mers were identified that might be useful as signatures. Signature oligonucleotides are available for over 80% of the nodes in the representative tree.

NASA Discipline Life Sciences Technologies↗

Visible - Near Infrared Spectral Indices for Mapping Mineralogy and Chemistry with OSIRIS-REx

The primary objective of the Origins, Spectral Interpretation, Resource Identification, SecurityRegolith Explorer (OSIRIS-REx) mission is to return to Earth a pristine sample of carbonaceous material from the primitive asteroid (101955) Bennu. To support compositional mapping as part of sample site selection and characterization, we tested 95 spectral parameters on visible to near infrared laboratory reflectance data of minerals and carbonaceous meteorites to find which of these parameters reliably identified spectral features of interest. Most spectral parameters had high positive detection rates when used on spectra of pure, single component materials. The meteorite spectra have fewer and weaker absorption features and, as a result, fewer detections with the spectral parameters. Parameters targeting absorptions at 0.7 and 2.7 – 3 µm, which arise due to hydrated minerals, were most successful for the meteorites. Based on these results, we have identified a set of 17 parameters that are most likely to be useful at Bennu and spectral analogs. These parameters detect olivines, pyroxenes, carbonates, water/OH-bearing minerals, serpentines, ferric minerals, and organics. Particle size and albedo are known to affect band depth but had a negligible impact on parameter accuracy. The effect of instrument-like noise added to the laboratory spectra can result in more false positive detections, but these exhibit large errors. Our study has determined the prioritization of spectral parameters used for OSIRISREx spectral analysis and mapping and informs the reliability of all parameter-derived data products.

Hannah H Kaplan↗

A study of examiner accuracy in cartridge case comparisons. Part 2: Examiner use of the AFTE range of conclusions

Here, this report describes an analysis of how examiners used the Association of Firearm and Toolmark Examiners (AFTE) Range of Conclusions in a controlled study undertaken to estimate examiner error rates in comparing cartridge cases. Results of the error rate analysis are reported in [1]; this paper focuses on a broader analysis of how the entire collection of classification categories, especially those in the Inconclusive range, were used by the participating examiners. Volunteer active examiners with AFTE membership or working in laboratories that participate in Association of Crime Laboratory Directors (ASCLD) were provided with 15 sets of three known and one questioned cartridge cases fired from a collection of 25 new Ruger SR9 handguns. Remington 9-mm Luger (manufacturer designation L9MM3) ammunition was used and comparison sets were made up of cartridge cases fired within 100 cartridges of each other for each gun. Examiners were provided with a background survey, an answer sheet allowing for the AFTE Range of Conclusions, and return shipping materials. The participating examiners were provided with both same-source and different-source comparison sets allowing the study to assess both error rates. Responses were received from 218 participating examiners. The overall rate of false-negatives was estimated as 0.367 % from comparisons known to be from the same firearm but reported as eliminations. The overall rate of false-positives was estimated as 1.01 % from comparisons known to be from different firearms but reported as identifications. In the case of true different-source examinations, it is clear that the three Inconclusive categories and the Elimination category are not used consistently by all examiners. We identify five different apparent patterns of use of the AFTE Range of Conclusions scale, and discuss possible reasons for and implications of these differences.

99 GENERAL AND MISCELLANEOUS↗

PREPARING FOR ADVANCED LIGO: A STAR–GALAXY SEPARATION CATALOG FOR THE PALOMAR TRANSIENT FACTORY

The search for fast optical transients, such as the expected electromagnetic counterparts to binary neutron star mergers, is riddled with false positives (FPs) ranging from asteroids to stellar flares. While moving objects are readily rejected via image pairs separated by ∼1 hr, stellar flares represent a challenging foreground, significantly outnumbering rapidly evolving explosions. Identifying stellar sources close to and fainter than the transient detection limit can eliminate these FPs. Here, we present a method to reliably identify stars in deep co-adds of Palomar Transient Factory (PTF) imaging. Our machine-learning methodology utilizes the random forest (RF) algorithm, which is trained using >3×10{sup 6} sources with Sloan Digital Sky Survey (SDSS) spectra. When evaluated on an independent test set, the PTF RF model outperforms the SExtractor star classifier by ∼4%. For faint sources (r{sup ′}⩾21 mag), which dominate the field population, the PTF RF model produces a ∼19% improvement over SExtractor. To avoid false negatives in the PTF transient-candidate stream, we adopt a conservative stellar classification threshold, corresponding to a galaxy misclassification rate of 0.005. Ultimately, ∼1.70×10{sup 8} objects are included in our PTF point-source catalog, of which only ∼10{sup 6} are expected to be galaxies. We demonstrate that the PTF RF catalog reveals transients that otherwise would have been missed. To leverage its superior image quality, we additionally create an SDSS point-source catalog, which is also tuned to have a galaxy misclassification rate of 0.005. These catalogs have been incorporated into the PTF real-time pipelines to automatically reject stellar sources as non-extragalactic transients.

79 ASTRONOMY AND ASTROPHYSICS↗