Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy system analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Status Report on Thermal Extraction Modeling within HYBRID

Idaho National Laboratory continues to be at the forefront of advanced reactor systems and integrated energy systems (IES) research. The HYBRID modeling repository is the computational modeling repository used to evaluate potential IES configurations. To support IES analysis, it is necessary to develop models that can evaluate a range of thermal integration points within given energy conversion systems. This work includes as many technologies as possible anticipating that many technologies will be deployed to broadly reduce climate impacts of energy intensive processes. To provide this analysis, a new balance of plant model has been generated. This report will discuss progress on this new main model and discuss nominal conditions for the primary reactor types contained within HYBRID.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling Variable Renewable Energy and Storage in the Power Sector

The emergence of variable renewable energy and battery storage technologies have fundamentally transformed the electric power sector and generated demand for analysis to understand their roles in future energy systems. Although unique characteristics of these resources are well-recognized and require more sophisticated methodologies to capture effectively, guidance is limited on best practices and research gaps. This paper selectively reviews recent literature and draws upon our collective modeling experience to offer recommendations to analysts and consumers of model outputs on approaches for modeling variable renewable energy and storage in long-term electric sector models. We focus on regional- and national-scale models with technological, temporal, and spatial detail given their prevalence in planning and policy analysis, though insights are applicable in other settings. The review highlights how the research frontier has advanced in representing renewables and energy storage over the past decade; however, given the many considerations involved with appropriately capturing salient economic and operational characteristics of renewables, there is a gap between commonly used models and state-of-the-art methods. Model simplifications can materially impact policy analysis associated with power sector decarbonization and high renewables deployment, and improving model representations of variable renewables can enhance insights for policymakers and other stakeholders. This review can point the way for improved methods for established models and designs for emerging ones.

energy and environmental policy↗

Broadband piezoelectric energy harvesting microgyroscopes: Design and nonlinear analysis

Small devices in remote or difficult-to-reach areas can benefit from harvesting energy from mechanical wasted energy, which reduces the requirement for a new power source. A multi-purpose energy harvesting microgyroscope system based on piezoelectric materials is suggested. The necessity of taking spatially varying electrostatic forces is examined. Considering the effects of the system's width and thickness, DC voltage, and angular speed the systems inherent frequencies are found. The partial differential equations describing the system's dynamics are numerically solved by using the differential quadrature method. Further, the numerical analysis enables to identify the optimal system design for broadband energy harvesting. The simulation results reveal that a system with a non-symmetric beam design is adequate for broadband energy harvesting. This is associated with the applied DC voltage, which may be modified to improve the broadband frequency of the system. It is concluded that the nonlinear softening effects create a broadband frequency response with high voltage output. However, DC and AC voltages need to be carefully selected in order to avoid the dynamic pull-in.

30 DIRECT ENERGY CONVERSION↗

Use of Operating Agreements and Energy Storage to Reduce Photovoltaic Interconnection Costs: Conceptual Framework

This report explores one integrated technical and process concept designed to manage interconnection costs and streamline interconnection timelines to support near-term renewable energy deployment. We describe a new agreement between renewable energy developers and utilities, informed by the technical analysis. The agreement defines the operational parameters for a renewable energy system, with the goal of reducing risk and cost to all parties. This work provides a foundation upon which other states and utilities may build proof of concept. This report is supported by a technical analysis that is detailed in a companion report, "Use of Operating Agreements and Energy Storage to Reduce Photovoltaic Interconnection Costs: Technical and Economic Analysis" (McLaren et al. 2022).

14 SOLAR ENERGY↗

Revenue Analysis of Stationary and Transportable Battery Storage for Power Systems: A Market Participant Perspective

The power system faces a growing need for increased transmission capacity and reliability with the rising integration of renewable energy resources. To tackle this challenge, Battery Energy Storage Systems (BESSs) prove effective in enhancing grid capacity and relieving transmission congestion. This paper focuses on the PJM market, conducting a thorough revenue analysis to identify and characterize highly profitable nodes for BESS market participants. A comparison between stationary and transportable BESSs reveals that the transportable BESSs can generate higher potential revenue in energy and regulation markets. Based on these findings, we propose an optimal placement algorithm to support market participants in selecting strategic sites for BESS installation, validated with real PJM market data. This paper provides valuable insights for navigating market-based power system participants and promoting the effective integration of BESSs.

25 ENERGY STORAGE↗

Cost and Efficiency Analysis for Hybrid AC/DC Distribution System Planning with PV and Battery

Distribution system planning is one of the main tasks for the electric utilities. Cost and energy efficiency are two main concerns in the distribution planning process. In this work, cost and efficiency analyses are conducted for the hybrid AC and DC distribution grids for the planning purposes. The IEEE 34-bus feeder has been applied for the case studies. The investment cost, operation and maintenance cost, replacement cost, etc., have been considered in the life cycle cost analysis. Power losses of both the AC and DC section are calculated with an open source simulation tool, the Open Distribution Simulator Software (OpenDSS). The proposed framework can be applied to quantitatively evaluate the cost and efficiency of hybrid AC and DC distribution grids and help comparing different planning options.

AC/DC hybrid system planning↗

HYPSTAT (Hydrogen Production, Storage, and Transmission Analysis Tool) [SWR-23-04]

The Hydrogen Production, Storage, and Transmission Analysis Tool (HYPSTAT) is a modeling framework developed by the National Renewable Energy Laboratory (NREL) to support the analysis of hydrogen systems. HYPSTAT focuses on key components of hydrogen infrastructure, particularly electrolytic hydrogen production, hydrogen storage, and hydrogen transmission, as part of the transition to decarbonized energy systems HYPSTAT operates as a supply-to-demand model, taking a fixed exogenous demand as input and optimizing the design and operation of the hydrogen system to meet that demand. It determines cost-optimal configurations based on specified technology options and system constraints.

Brauch, Joseph [National Renewable Energy Laborato↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ASEAN Technical Exchange Workshop for System Operators, Regulators, and Policymakers

This presentation provides an in-depth exploration of power system planning, cross-border electricity trading, and battery energy storage systems (BESS), offering actionable insights for system operators, regulators, and policymakers. The first section delves into power system planning and analysis, focusing on capacity expansion models and resource adequacy studies, including their role in optimizing system efficiency, managing emissions, and addressing system reliability risks. Key considerations, such as integration of transmission into generation planning and the forecasting versus optimization of customer distributed energy resources (DER) technologies, are explored. The session highlights critical trade-offs in spatial granularity and model runtimes, as well as the feasibility of aligning distribution investments with capacity expansion efforts. The second section examines cross-border electricity trading, with an emphasis on resource adequacy concepts such as reliability targets, loss of load expectation (LOLE), and planning reserve margins (PRM). Case studies on reserve market design and coordination across US regions provide insights into improving reserve deliverability and managing interregional power balance and congestion. This section also addresses market-to-market congestion management, including advanced strategies for high-voltage direct current (HVDC) optimization and ancillary service delivery. Finally, the presentation covers the rapid evolution of Battery Energy Storage Systems (BESS), highlighting their operational growth, regulatory frameworks, and use cases in grid flexibility, energy storage, and reliability. The discussion focuses on the benefits of BESS for system stability, resilience, and integration of renewable energy, offering insights into its role as a vital component in the transition toward a more sustainable and flexible grid. Key performance parameters, such as throughput, round-trip efficiency, and state of charge, are also examined.

25 ENERGY STORAGE↗

Life-Cycle Assessment Integration into Scalable Open-Source Numerical Models (LiAISON) for Prospective Impact Analysis of Novel Technologies

Decarbonizing the industrial sector is a significant challenge in achieving a net-zero greenhouse gas (GHG) emissions economy by 2050 and the Paris Agreement, i.e., a global climate change mitigation target of achieving a maximum average temperature change potential of 1.5 Degrees Celsius or less by 2100 with respect to pre-industrial levels. In the United States (US), the industrial sector accounts for 23% of total GHG emissions and is home to a number of hard-to-electrify activities. The chemicals subsector has the single largest subsector emissions profile after direct emissions from fossil fuel combustion and leakage from fossil fuel distribution systems. Within the chemicals subsector, many processes depend on hydrogen or ammonia precursors. Decarbonizing these two commodities would contribute significantly to decarbonizing the industrial sector as hydrogen could also be used for low carbon steel production (e.g., hydrogen-based direct reduction of iron) and other industrial applications. Emerging technologies require the application of prospective life cycle assessment (LCA), which can account for technology (foreground) scaling and process improvements via learning-by-doing, among others. In many cases, the future system context (background) in which the technologies are assumed to operate in is equally relevant. Background scenarios generated by integrated assessment models (IAM) can coherently incorporate potential future dynamics of the energy-climate-human-land system. Further, IAM scenarios are harmonized across socioeconomic and climate change mitigation pathways, which facilitates the comparability of prospective LCAs using different IAMs. We introduce an open source prospective LCA framework, the Life-cycle Assessment Integration into Scalable Open-source Numerical models (LiAISON), to analyze the non-linear relationships between technology foreground and the future energy system background across a series of midpoint and resource use metrics. The integration of LCA and IAM data is achieved using prospective environmental Impact assessment (PREMISE). We showcase it by assessing two Power-to-Hydrogen (PtH2) processes, namely Solid Oxide Electrolysis (SOE) and Polymer Electrolyte Membrane Electrolysis (PEME). We compare the technologies to a baseline of hydrogen production via natural gas-based Steam Methane Reforming (SMR) in a US context of multiple energy system and climate change mitigation futures. Besides providing an analysis that specifies the LCA results ranges with temporal and geospatial explicitness across the two technologies, metrics, and impact assessment methods, this research also aims to establish a base framework that can be expanded to use other IAM generated scenarios and US open-source life cycle inventory (LCI) databases. We find that the temporal environmental performance of either technology or their difference to SMR is directly influenced by the underlying background dynamics. Additionally we compare our results by linking two other prospective models with LiAISON - GCAM (Global Change Assessment Model) and ReEDS (Regional Energy Deployment System) to analyze the effect of changing background scenarios using varying predictions in life cycle analysis.

decarbonizing↗

Automated model generation and parameter estimation of building energy models using an ontology-based framework

This study presents a methodology for automated model generation and parameter estimation of building energy models using semantic modeling and Bayesian estimation. Semantic modeling techniques are used to represent the system components and their interactions, facilitating the automatic generation of a simulation model from dynamic component models. The proposed approach is applied to a case study of a ventilation system where a simulation model is generated, calibrated, and assessed through different performance metrics. These metrics demonstrate the accuracy and reliability of both model point estimates and probabilistic prediction intervals across all model outputs. Overall, the proposed methodology offers a systematic and automated approach to model development and calibration in building energy systems, with potential applications in building performance analysis, monitoring, and optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lithium-Ion Battery Design for Grid-Scale Energy Storage App

A software that delivers parameters from energy storage system (ESS) to container, rack, module and single cell design, as well as data analysis on arbitrage energy and frequency regulation of ESS in different regions, has been developed. The Lithium-ion Battery Design for Grid-scale Energy Storage App V1.0 has the capability to output the system, module and cell design with the energy, power, capacity, group method, cost of single cell, and single cell test protocol which break down from input energy storage system data in different regions. The default chemistry of the battery is LiFePO4 and graphite. The energy density of the graphite/LiFePO 4 pouch cell ranges from 100 Wh/kg to 200 Wh/Kg in the software. Graphite/LiFePO 4 pouch cell (up to 1Ah in lab) manufacturing line is also built and can be used to evaluate the test protocol, moreover, for electrolyte evaluation in other ESMI seedling projects. The software enables rapid prototyping to accelerate energy storage research, development, and manufacturing.

Liu, Dianying↗

National Park Service: Spotlight on Partnerships

This presentation covers the National Park Service net zero vision and related technical analysis. The NPS/NREL/FEMP partnership include: (1) Partnership spanning more than a decade; (2) Technical support encompasses renewable energy analysis, audit support, fleet technical analysis, resilience assessments, and more.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Policy and Regulatory Environment for Utility-Scale Energy Storage: India

This report is part of a series investigating the potential for utility-scale energy storage in South Asia. The first part of the work is focused on opportunities and barriers for energy storage within existing policy and regulatory frameworks in the region. This report applies the previously-developed Energy Storage Readiness Assessment to evaluate the policy and regulatory environment for energy storage in India. Forthcoming reports will expand this analysis to other countries in South Asia. These evaluations are designed to provide insights on the opportunities and barriers for energy storage growth and deployment in each country. The second part of this work consists of techno-economic analysis to understand the drivers of energy storage investments in South Asia. Using NREL’s power system planning and operational models of South Asia, this analysis will identify potential storage applications and growth under various cost, policy, and demand growth scenarios. In addition, the regulatory and policy barriers and incentive mechanisms identified in the first task will be incorporated into the modeling task to understand their impact on energy storage deployment and operation. Together these studies will inform the applications and value of energy storage on South Asia power systems and policy and regulatory pathways to realize this value.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

Using Co-Simulation to Model Interconnect-Scale Power Systems from Loads to Generators

Co-simulation is a modeling technique that allows analysts to combine simulation tools and their corresponding models to exchange data during run-time, allowing the creation of larger and more complex models across heterogeneous domains. HELICS is a co-simulation platform developed over the past six years that has been shown to be effective for these multi-domain analysis. Recently, a HELICS-based analysis was completed where the ERCOT electrical interconnect in the United States was modeled in high detail from bulk power system generation to individual customer loads. This model was used to evaluate a flat-rate and transactive energy tariff with integrated wholesale and retail real-time and day-ahead energy markets. This modeling allows detailed analysis showing how the operations of the power system under these tariffs impact all actors in the power system, from individual customers to bulk power system operators.

co-simulation, HELICS, transactive energy system, ↗