Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy predictions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Probing the thermodynamics and kinetics of ethylene carbonate reduction at the electrode–electrolyte interface with molecular simulations

Understanding the formation of the solid-electrolyte interphase (SEI) in lithium-ion batteries (LIBs) is an ongoing area of research due to its high degree of complexity and the difficulties encountered by experimental studies. Herein, we investigate the initial stage of SEI growth, the reduction reaction of ethylene carbonate (EC), from both a thermodynamic and kinetic approach with theory and molecular simulation. We employed both the potential distribution theorem (PDT) and the SMD implicit solvent model to EC solvation for the estimation of reduction potentials of Li$^+$, EC, and Li$^+$-solvating EC (s-EC), as well as reduction rate constants of EC and s-EC. We find that solvation effects greatly influence these quantities of interest, particularly the Li$^+$/Li reference electrode potential in EC solvent. Further, we also compute the inner- and outer-sphere reorganization energies for both EC and s-EC at the interface of liquid EC and a hydroxyl-terminated graphite surface, where total reorganization energies are predicted to be 76.6 and 88.9 kcal/mol, respectively. With the computed reorganization energies, we estimate reduction rate constants across a range of overpotentials and show that EC has a larger electron transfer rate constant than s-EC at equilibrium, despite s-EC being more thermodynamically favorable. Furthermore, this manuscript demonstrates how ion solvation effects largely govern the prediction of reduction potentials and electron transfer rate constants at the electrode-electrolyte interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel application of the modal strain energy technique for state-of-the-art damping predictions

Structural damping, which measures the energy dissipation of a vibrating structure, is a key modeling input for lightweight structures but is notoriously hard to predict. This work utilizes vibration-based measurements of centimeter-scale coupons and the modal strain energy approach to predict structural damping of a lightly damped structure. The approach was originally validated with panels shorter than a meter in length. This work extends the validation to a 2.75 m beam made of unidirectional and biaxial glass fiber laminates bonded by adhesive. The comparison between three-dimensional finite element model predictions and full-scale experimental measurements of damping show an average error of 5.2% for the first five modes. Additionally, the modal strain energy approach is newly applied with a one-dimensional geometrically exact beam theory model and a two-dimensional sectional analysis solver. This beam approach accurately predicts the damping behavior of the first bending modes but loses accuracy for higher order modes that are dominated by three-dimensional effects. This novel approach provides faster simulations while allowing arbitrary beam cross sections. The paper also investigates traditional and high-force dynamic mechanical analysis to measure structural damping of coupons. Both alternatives show significant errors in attempted validation against the theoretical thermoelastic damping of aluminum coupons.

17 WIND ENERGY↗

Integrated Experimental and Computational K-Edge X-ray Absorption Near-Edge Structure Analysis of Vanadium Catalysts

X-ray Absorption Near-Edge Structure (XANES) spectroscopy is a powerful tool to reveal key structural and electronic features of isolated catalytic sites, yet insights into molecular structure and more detailed orbital analysis through a combination of experimental and computed XANES analysis are necessary for accurate interpretation of the spectra, especially when significant heterogeneity exits among the catalytic sites. Herein, we present an integrated computational and experimental strategy to determine both primary and secondary bonding interactions within the XANES pre-edge region for organovanadium complexes, which was developed using a series of well-defined molecular vanadium complexes and then applied to the characterization of a supported organovanadium olefin hydrogenation catalyst. Time-dependent density functional theory is used to predict the energy of pre-edge XANES features for a series of vanadium complexes with a variety of oxidation states and local coordination environments. Further, a calibration scheme incorporating different density functionals and basis sets is established, resulting in an optimized scheme that accurately predicts pre-edge energies with a mean absolute error of 0.40 eV. Second-shell coordination (e.g., V---V) effects within XANES are identified through the analysis of the computed dominant orbital contributions for multi-vanadium complexes. Orbital analysis also provided confirmation that the vanadium-hydride formation combined with the heterogeneity of the catalytic active species in ole-fin hydrogenation caused the energy shift and broadening of the pre-edge peak after hydrogen treatment of the silica-supported organovanadium pre-catalyst. This work further elucidates computational XANES simulations and techniques potentially guiding characterization in surface organometallic chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Internal energy balance and aerodynamic heating predictions for hypersonic turbulent boundary layers

The elemental equation governing heat transfer in aerodynamic flows is the internal energy equation. For a boundary layer flow, a double integration of the Reynolds-averaged form of this equation provides an expression of the wall heat flux in terms of the integrated effects, over the boundary layer, of various physical processes: turbulent dissipation, mean dissipation, turbulent heat flux, etc. Recently available direct numerical simulation data for a Mach 11 cold-wall turbulent boundary layer allows a comparison of the exact contributions of these terms in the energy equation to the wall heat flux with their counterparts modeled in the Reynolds-averaged Navier-Stokes (RANS) framework. Various approximations involved in RANS, both closure models as well as approximations involved in adapting incompressible RANS models to a compressible form, are assessed through examination of the internal energy balance. There are a number of potentially problematic assumptions and terms identified through this analysis. Here, the effect of compressibility corrections of the dilatational dissipation type is explored, as is the role of the modeled turbulent dissipation, in the context of wall heat flux predictions. The results indicate several potential avenues for RANS model improvement for hypersonic cold-wall boundary-layer flows.

42 ENGINEERING↗

Self-consistent implementation of locally scaled self-interaction-correction method

Recently proposed local self-interaction correction (LSIC) method is a one-electron self-interaction-correction (SIC) method that uses an iso-orbital indicator to apply the SIC at each point in space by scaling the exchange–correlation and Coulomb energy densities. The LSIC method is exact for the one-electron densities, also recovers the uniform electron gas limit of the uncorrected density functional approximation, and reduces to the well-known Perdew–Zunger SIC (PZSIC) method as a special case. This article presents the self-consistent implementation of the LSIC method using the ratio of Weizsäcker and Kohn–Sham kinetic energy densities as an iso-orbital indicator. The atomic forces as well as the forces on the Fermi-Löwdin orbitals are also implemented for the LSIC energy functional. Results show that LSIC with the simplest local spin density functional predicts atomization energies of the AE6 dataset better than some of the most widely used generalized-gradient-approximation (GGA) functional and barrier heights of the BH6 database better than some of the most widely used hybrid functionals. The LSIC method [a mean absolute error (MAE) of 0.008 Å] predicts bond lengths of a small set of molecules better than the PZSIC-LSDA (MAE 0.042 Å) and LSDA (0.011 Å). Furthermore, this work shows that accurate results can be obtained from the simplest density functional by removing the self-interaction-errors using an appropriately designed SIC method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Leveraging System Dynamics to Predict the Commercialization Success of Emerging Energy Technologies: Lessons from Wind Energy

The United States urgently needs to tackle the climate crisis while enhancing energy security and resiliency. The complexity of the U.S. energy system, with its interconnected elements, makes predicting future states challenging, especially with the introduction of novel energy systems like wind, solar, clean hydrogen, and advanced nuclear technologies. Modern systems engineering methods and tools can provide deeper insights into these dynamics and future behaviors. This research aims to develop a comprehensive model that captures the main elements and behaviors of new energy technologies within the existing energy system. We hypothesized that the market uptake of novel energy systems is influenced by multiple diverse factors, such as technological learning, availability of resources, and economic incentives; examined the history of electricity generation using land-based wind technologies; and developed a system dynamics model to investigate the relationships between capacity growth and influencing factors, both internal and external. The developed model yielded outcomes that confirmed the hypothesized dynamics of wind energy system diffusion through a quantitative comparison of installed capacity and highlighted the significant influence of resource availability, federal incentives (production tax credits), and technological learning on capacity growth and cost reduction. This research aims to support informed decision-making for investments in novel energy systems and aid in developing effective policies for technology deployment.

17 WIND ENERGY↗

Assessing the accuracy of compound formation energies with quantum Monte Carlo

Accurately predicting the formation energy of a compound, which describes its thermodynamic stability, is a key challenge in materials physics. Here, we employ a many-body quantum Monte Carlo (QMC) with single-reference trial functions to compute the formation energy of two electronically disparate compounds, the intermetallic VPt2 and the semiconductor CuI, for which standard density functional theory (DFT) predictions using both the Perdew-Burke-Ernzerhof (PBE) and the strongly constrained and appropriately normed (SCAN) density functional approximations deviate markedly from available experimental values. For VPt2, we find an agreement between QMC, SCAN, and PBE0 estimates, which therefore remain in disagreement with the much less exothermic experimental value. For CuI, the QMC result agrees with neither SCAN nor PBE pointing towards DFT exchange-correlation biases, likely related to the localized Cu 3d electrons. Compared to the behavior of some density functional approximations within DFT, spin-averaged QMC exhibits a smaller but still appreciable deviation when compared to experiment. The QMC result is slightly improved by incorporating spin-orbit corrections for CuI and solid I 2 , so that experiment and theory are brought into imperfect but reasonable agreement within about 120 meV/atom.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Relativistic and magnetic Breit effects for the reaction Sg + 6CO → Sg(CO)6 and Sg(OC)6: Prediction of the existence and atomization energy of the isomer Sg(OC)6

Our ab initio all-electron fully relativistic Dirac–Fock (DF) and Dirac–Fock–Breit–Gaunt (DFBG) and nonrelativistic (NR) Hartree–Fock (HF) calculations for seaborgium hexacarbonyl Sg(CO)6 predict atomization energies (Ae) of 68.81, 69.28, and 67.69 eV, respectively, at the corresponding optimized octahedral geometry. However, our DF, DFBG, and NR HF calculations for the isomer Sg(OC)6 yield atomization energies of 64.30, 64.77, and 62.62 eV, respectively, at the optimized geometry for this species. The optimized Sg–C and C–O bond distances (in Å) for octahedral Sg(CO)6 using our DF (NR) calculations are 2.15 (2.32) and 1.11 (1.11), respectively. However, the optimized Sg–O and O–C bond distances (in Å) for the isomer octahedral Sg(OC)6 obtained with our DF (NR) calculations are 2.80 (2.73) and 1.10 (1.11), respectively. Our prediction of the greater stability of Sg(CO)6 isomer at both the relativistic (DF and DFBG) and the NR HF levels of theory lends further support to the detection of Sg(CO)6 in the state-of-the-art gas-phase experimental studies of the carbonyl complex of seaborgium reported by Even et al. [Science 345(6203), 1491 (2014)].

Materials Science↗

Connecting primordial gravitational waves and dark energy

Cosmic acceleration manifested in the early universe as inflation, generating primordial gravitational waves detectable in the cosmic microwave background (CMB) radiation. Cosmic acceleration is occurring again at present as dark energy, detectable in cosmic distance and structure surveys. We explore the intriguing idea of connecting the two occurrences through quintessential inflation by an α-attractor potential without a cosmological constant. For this model we demonstrate robustness of the connection 1 + w 0 ≈ 4/(3N 2 r) between the present day dark energy equation of state parameter w 0 and the primordial tensor to scalar ratio r for a wide range of initial conditions. Analytic and numerical solutions produce current thawing behavior, resulting in a tight relation w a ≈ -1.53(1 + w 0 )≈ -0.2 (4 × 10 -3 /r). Upcoming CMB and galaxy redshift surveys can test this consistency condition. In conclusion, within this model, lack of detection of a dark energy deviation from Λ predicts a higher r, and lack of detection of r predicts greater dark energy dynamics.

79 ASTRONOMY AND ASTROPHYSICS↗

New, low-energy excitations in 107 Mo and 109 Mo

New ground-state level with spin-parity 1/2 + is established in 109 Mo, 69.8 keV below the previously reported 5/2(+) ground state in this nucleus, based on precise spectroscopy measurements of gamma radiation following spontaneous fission of 248 Cm performed using the Eurogam2 array of anti-Compton spectrometers. Analogous measurement of gamma radiation following spontaneous fission of 252 Cf, performed using the Gammasphere array, confirms the new 1/2 + ground state of 107 Mo, proposed recently and establishes the isomeric character of the 5/2 + first excited state in 107 Mo. Two beta-decaying isomers are suggested in 111 Mo nucleus based on regular energy systematics, supporting previous predictions. Low-energy excitations in Mo isotopes are interpreted and compared to calculations reported in the literature. The results suggest shape transition from prolate to oblate deformation at N >= 67.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy Intensity Baselining and Tracking Guidance

Each company joining the U.S. Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) commits to establishing an energy consumption and energy intensity (EI) baseline and to tracking its energy performance over a 10-year period against that baseline. The baseline must reflect a company’s energy consumption over a 12-month period, covering all its U.S.-based operations. Energy consumption is calculated by fuel type in terms of primary energy (also known as source energy). EI is broadly defined as the amount of energy consumed per unit of output produced. For this guidance document and for the program, the term energy performance represents an evaluation of a facility’s capacity to use energy efficiently. Metrics used to assess a facility’s energy performance can include EI, energy consumption, improvements in EI, etc. Establishing an energy baseline and tracking system is a critical first step in effectively managing energy use. Developing a baseline can help a company understand energy use within the corporation and give it a point of comparison to evaluate future efforts to improve energy performance. It can also support efforts to validate a company’s energy management activities, improve comparative analyses when using benchmarks, and help in predicting future energy needs. In addition, a company that normalizes its performance data can determine highly defensible measures of energy savings generated through implemented energy efficiency projects. Establishing a baseline and tracking energy performance is also a requirement for ISO 50001 certification. Although basic energy data can be collected through utility bills, most manufacturers will have to perform additional analyses to develop accurate and robust energy baselines and tracking systems. Energy is consumed in many ways within the manufacturing sector and can come from multiple sources. Energy is sometimes generated and sold to other parties or captured and reused on-site. External events can exert a significant impact on a facility or company’s energy use independent of any purposeful efforts to improve energy efficiency. Operational changes, such as production shifts—which may be inevitable for some companies over the 10-year period covered by the program—can also make a big difference in energy use. Since Better Plants asks companies to account for all their U.S.-based operations, mergers, acquisitions, and divestitures can also have significant implications for a company’s energy metrics. This document aims to demystify the sometimes complex baselining process. It devotes special attention to the task of normalizing and adjusting energy consumption to account for external factors, such as weather and production changes. A key recommendation is that companies use regression analysis to normalize their energy consumption data whenever possible. Regression analysis is a statistical technique that estimates the dependence of a variable (i.e., energy use in the context of Better Plants) on one or more independent variables such as ambient temperature, while controlling for the influence of other variables at the same time. A properly developed regression analysis can provide a reliable estimate of energy savings resulting from energy improvement strategies and projects by accounting for the effects of variables such as annual production levels and weather. DOE has developed a companion Energy Performance Indicator software tool (EnPI) to simplify the baselining process. This tool can run regression models, calculate changes in EI at the facility level, and automatically compile facility-level data into a corporate-wide metric. Note that although the relevant equations used to calculate EI are provided in this document, the EnPI tool will automatically perform most calculations for the user. Additionally, Better Plants Partners (Partners) can call on their Technical Account Manager (TAM) to help them establish a baseline and assist with the necessary calculations to track progress.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PANDEMIC: Occupancy driven predictive ventilation control to minimize energy consumption and infection risk

During the SARS-CoV-2 (COVID-19) pandemic, governments around the world have formulated policies requiring ventilation systems to operate at a higher outdoor fresh air flow rate for a sufficient time, which has led to a sharp increase in building energy consumption. Therefore, it is necessary to identify an energy-efficient ventilation strategy to reduce the risk of infection. In this study, we developed an occupant-number-based model predictive control (OBMPC) algorithm for building ventilation systems. First, we collected the occupancy and Heating, ventilation, and air conditioning system (HVAC) data from March to July 2021. Then, four different models (Auto regression moving average-based multilayer perceptron (ARMA_MLP), Recurrent neural networks (RNN), Long short-term memory networks (LSTM), and Nonhomogeneous Markov with change points detection (NH_Markov)) were used to predict the number of room occupants from 15 min to 24 h ahead with an interval output. We found that each model could predict the number of occupants with 85% accuracy using a one-person offset. Furthermore, the accuracy of 15 min of the ahead prediction could reach 95% with a one-person offset, but none of them could track abrupt changes. The occupancy prediction results were used to calculate the ventilation demand using the Wells-Riley equation, and the upper bound can maintain an infection risk lower than 2% for 93% of the day. This OBMPC model could reduce the coil load by 52.44% and shift the peak load by 3 h up to 5 kW compared with 24 × 7 h full outdoor air (OA) system when people wear masks in the space. The occupancy prediction uncertainty could cause a 9% to 26% difference in demand ventilation, a 0.3°C to 2.4°C difference in zone temperature, a 28.5% to 44.5% difference in outdoor airflow rate, and a 10.7% to 28.2% difference in coil load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Evaluation of Occupancy-Aware Model Predictive Control for Residential Building Energy Efficiency and Occupant Comfort

The residential sector accounts for 25% of global primary energy consumption. Two methods have previously been proposed to reduce residential energy use associated with the provision of occupant thermal comfort: 1. Occupancy-based HVAC control, operating systems only during confirmed occupancy, and 2. model predictive control (MPC), harnessing a mathematical model and forecasts to find optimal operating strategies. Previous studies estimate the average energy savings of the two methods individually in the range of 21% and 16%, respectively. The research presented herein was carried out to evaluate the energy savings potential in residential buildings by combining both approaches across different climates, house vintages, and occupancy patterns. Occupancy and eight different physical modalities (e.g. CO2 and VOC) data were collected from five homes for time periods of 4–9 weeks. Collected data sets were used to train occupancy prediction models suggested by an extensive literature survey of occupancy model types. The trained prediction models were combined with MPC and detailed EnergyPlus building simulation models to evaluate residential building performance in terms of annual energy savings and thermal comfort, along with discomfort exceedance metrics. Multiple home types and regions were analyzed to understand regional and climate-dependent potential. Based on actual field data, the occupancy models had a prediction inaccuracy between 8% and 35% across the investigated homes. Average occupancy for the collected data ranged from 56% to 86%, a typical range reported in the literature. Building simulations were conducted for three control scenarios: conventional thermostatic control, occupancy-based, and occupancy-based MPC. The results indicate that all advanced strategies improve upon the conventional control, with some scenarios cutting energy use in half with only occasional incurrence of discomfort. The findings indicate that occupancy-aware model predictive residential building control has the potential to drastically reduce energy use and associated emissions while maintaining occupant comfort for both new and existing buildings.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Wind Energy Accomplishments and Year-End Performance Report: Fiscal Year 2022

Four decades ago, construction was just beginning on experimental turbines at the National Wind Technology Center (NWTC). Today, the U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory (NREL) facility is the centerpiece of the laboratory's Flatirons Campus, a world-class hub for renewable energy research. The nation's shift to 100% clean electricity by 2035 will require a mix of renewable energy sources and strategies - and together, wind and solar energy could account for 60% to 80% of that clean energy resource. In Fiscal Year (FY) 2022, NREL scientists, engineers, and analysts contributed to these visionary goals through their wind energy research. As wind innovations push into new areas, NREL continues to play a vital role in advancing technology and addressing deployment barriers in pursuit of more efficient, reliable, and predictable wind energy systems. FY 2022 wind research and development explored the potential for dramatic growth in land-based systems, the launch of the nation's first commercial-scale offshore installations, and transmission infrastructure buildout. Land-based wind energy is one of the most cost-effective electricity supply options - but utility-scale deployment will require up to 10 times the current number of turbines. An NREL plan addressed this need to accelerate U.S. wind technology rollout at distributed and utility scales. Another project conducted by NREL and the Pacific Northwest National Laboratory (PNNL) helps position the nation's first major offshore wind corridor for success. The WETO-funded Atlantic Offshore Wind Transmission Study is evaluating options for balancing electricity supply and demand, while supporting resilience of the grid and marine industries. WETO, NREL, and other partners are working to enable the enormous supply chain and workforce changes the U.S. wind energy industry will need to meet net-zero-carbon-emissions targets. As part of a seminal series of DOE-funded supply chain studies, NREL analysts reported on the trade-offs involved in manufacturing large volumes of wind technologies, while addressing cost, workforce, and logistics issues. All of this research is supported by NREL's outstanding research teams, tools, data, and facilities. A WETO-funded international wind energy field campaign, the American WAKE experimeNt (AWAKEN), has brought together experts from NREL, PNNL, and Sandia National Laboratories to create the world's most comprehensive set of high-resolution data on wind energy atmospheric phenomenon. This study could lead to more accurate predictions of losses from turbine-to-turbine wake interactions, eventually helping wind plants capture more energy and operators save millions of dollars. In addition, NREL researchers developed testing, modeling, and analysis tools to improve the security of power grids by identifying wind power plant dynamic stability problems. A new Stochastic Soaring Raptor Simulator (SSRS) protects golden eagles from turbine encounters by predicting flight paths. This report provides more detail on these top achievements and other accomplishments made by NREL and its partners during FY 2022 (between October 1, 2021, and September 30, 2022).

accomplishments↗

CASPEr: an Approach to Characterize the Performance of Onboard Airplane Energy State and Automation Mode Prediction Functions

The Commercial Aviation Safety Team (CAST) has identified a set of safety enhancements to mitigate the risks of loss of control in-flight (LOCI) accidents and incidents involving commercial transport airplanes. In support of this, NASA has been developing technologies intended to enhance flight crew awareness of airplane systems, attitude, and energy state. This report describes preliminary ideas for a methodology to assess the goodness of onboard airplane energy state and automation mode prediction functions. The methodology is intended to contribute to the goal of moving these prediction technologies to the readiness level required for transition to industry and reduce the technology certification risks. In addition, this report describes a simulation-based approach named CASPEr (Characterization of Airplane State Prediction Error) to characterize the performance of these predictive functions over a wide range of operational conditions. The first exploratory version of this approach is described. The bulk of the report documents the initial results of tests to characterize the performance of an airplane trajectory prediction function. Future reports will give additional performance characterization results for this function and a complete description of the proposed methodology to assess such functions.

Torres-Pomales, Wilfredo↗

Calculation of energy deposition distributions for simple geometries

When high-energy charged particles pass through a thin detector, the ionization energy loss in that detector is subject to fluctuations or straggling which must be considered in interpreting the data. Under many conditions, which depend upon the charge and energy of the incident particle and the detector geometry, the ionization energy lost by the particle is significantly different from the energy deposited in the detector. This problem divides naturally into a calculation of the energy loss that results in excitation and low-energy secondary electrons which do not travel far from their production points, and a calculation of energy loss that results in high-energy secondary electrons which can escape from the detector. The first calculation is performed using a modification of the Vavilov energy loss distribution. A cutoff energy is introduced above which all electrons are ignored and energy transferred to low energy particles is assumed to be equivalent to the energy deposited by them. For the second calculation, the trajectory of the primary particle is considered as a source of secondary high-energy electrons. The electrons from this source are transported using Monte Carlo techniques and multiple scattering theory, and the energy deposited by them in the detector is calculated. The results of the two calculations are then combined to predict the energy deposition distribution. The results of these calculations are used to predict the charge resolution of parallel-plate pulse ionization chambers that are being designed to measure the charge spectrum of heavy nuclei in the galactic cosmic-ray flux.

Watts, J. W., Jr.↗