Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Futures for electrochromic windows on high performance houses in arid, cold climates

This study investigates high performance electrochromic windows used on a passive house and residential dwelling to IECC 2021 (i.e., IECC dwelling). In the lab, the electrochromic film switches transmitted solar heat gain coefficient (SHGC) from 0.09 to 0.7 and visible transmittance from 0.15 to 0.82 with power consumption of 1.23 W/m 2 during switching times less than 3 minutes. We extrapolate these results to a window assembly. Building energy models of the houses were evaluated in Santa Fe, New Mexico. A Monte Carlo analysis for 2020, 2040, 2060, and 2080 was conducted for Shared Socioeconomic Pathways 2-4.5, 3-7.0, and 5-8.5. Cases with and without the electrochromic windows and with and without electricity were used to determine energy use intensity and hours beyond thermal safety thresholds. The passive house showed 1.3-3.1% mean energy savings and the IECC dwelling 4.4-5.1% with electrochromic efficiency benefits growing into the future for both cases. Even so, overall savings decrease into the future for the passive house, due to growth in cooling load being dominant, conversely overall energy savings increase into the future for the IECC dwelling due to heating loads being dominant. For thermal resilience, the passive house exhibited a mean percent decrease of 0.02-0.31% hours in the extreme caution (i.e., > 32.2 °C, ≤ 39.4 °C) range while the IECC dwelling exhibited 0.38-4.38%. The study therefore shows that electrochromic windows will have smaller benefits for the passive house in comparison to the IECC dwelling. The relationship between electrochromic windows is shown to have a complex relationship between house efficiency and climate change by these results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The contribution of bioenergy to the decarbonization of transport: a multi-model assessment

The expected growth in the demand for passenger and freight services exacerbates the challenges of reducing transport GHG emissions, especially as commercial low-carbon alternatives to petroleum fuels are limited for shipping, air and long-distance road travel. Biofuels can offer a pathway to significantly reduce emissions from these sectors, as they can easily substitute for conventional liquid fuels in internal combustion engines. In this paper, we assess the potential of bioenergy to reduce transport GHG emissions through an analysis leveraging various integrated assessment models and scenarios, as part of the 33rd Energy Modeling Forum study (EMF-33). Furthermore, we find that bioenergy can contribute a significant, albeit not dominant, proportion of energy supply to the future transport sector: in scenarios aiming to keep the temperature increase below 2 °C by the end of the twenty-first century, models project that in 2100 bioenergy can provide on average 42 EJ/yr (ranging from 5 to 85 EJ/yr) for transport (compared to 3.7 EJ in 2018), mainly through lignocellulosic fuels. This makes up 9–62% of final transport energy use. Only a small amount of bioenergy is projected to be used in transport through electricity and hydrogen pathways, with a larger role for biofuels in road passenger transport than in freight. The association of carbon capture and storage (CCS) with bioenergy technologies (BECCS) is a key determinant in the role of biofuels in transport, because of the competition for biomass feedstock to provide other final energy carriers along with carbon removal. Among models that consider CCS in the biofuel conversion process the average market share of biofuels is 21% in 2100 (ranging from 2 to 44%), compared to 10% (0–30%) for models that do not. Cumulative direct emissions from the transport sector account for half of the emission budget (from 306 to 776 out of 1,000 GtCO 2 ). However, the carbon intensity of transport decreases as much as other energy sectors in 2100 when accounting for process emissions, including carbon removal from BECCS. Lignocellulosic fuels become more attractive for transport decarbonization if BECCS is not feasible for any energy sectors. Since global transport service demand increases and biomass supply is limited, its allocation to and within the transport sector is uncertain and sensitive to assumptions about political as well as technological and socioeconomic factors.

54 ENVIRONMENTAL SCIENCES↗

ComStock™ [SWR-19-33 and SWR-20-32]

ComStock™ is an analytic methodology for modeling the energy usage of the commercial building stock within the United States of America. The commercial building stock is represented through a sampling of complex probabilistic distributions of various features of interest for modeling energy usage within commercial buildings. Each sample from these distributions is converted into a building energy model based on the features of that specific sample. Each building energy model can be simulated as is, but additional changes can be made to the model through addition of energy conservation measures, component faults, or other desired alterations. The results of the simulations are then processed to provide insights for various stakeholders, including but not limited to policy makers, engineers, and marketers.

Horsey, Henry↗

Typical occupancy profiles and behaviors in residential buildings in the United States

The energy performance of a residential building is highly dependent on occupant's presence or non-presence in a building and their interactions with energy-consuming appliances. Typical occupancy schedules for residential buildings must be defined for applications such as building energy modeling as well as for assessing energy savings associated with the use of occupancy sensing technologies and occupancy-dependent controls. Currently, commonly used simulation programs assume a typical occupancy schedule, however, there is significant opportunity for improvement to these schedules as this is generally based on engineering judgement. This research uses 12 years of the American Time Use Survey (ATUS) data to develop typical occupancy schedules for a range of household types and occupant age ranges. This is compared to currently utilized residential occupancy schedules. In many cases the developed schedules exhibit similar patterns, however, differences are also found to be as high as 41% for certain periods of time. For occupancy sensing applications, the spatial-temporal distribution of occupants in residential buildings is also evaluated. These locations vary based on temporal factors as well as demographic factors such as age and number of occupants. Finally, the results of this research work towards improved occupancy schedule development can benefit both industry professionals and researchers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CryoFold: Determining protein structures and data-guided ensembles from cryo-EM density maps

Cryoelectron microscopy requires molecular modeling for refinement of structures. Ensemble models arrive at low free-energy molecular structures, but are computationally expensive and limited to resolving only small proteins. Here, we introduce CryoFold, a pipeline of molecular dynamics simulations that determines ensembles of protein structures by integrating density data of varying sparsity at 3–5 Å resolution with sequence information and coarse-grained topological knowledge of the protein folds. We present six examples, folding proteins between 72 and 2,000 residues, including large membrane and multi-domain systems, and results from two Electron Microscopy Data Bank (EMDB) competitions. Driven by data from a single state, CryoFold discovers ensembles of common low-energy models together with rare low-probability structures that capture the equilibrium distribution of proteins constrained by the density maps. Many of these conformations are experimentally validated and functionally relevant. We arrive at a set of best practices for data-guided protein folding that are controlled using a Python graphical user interface (GUI).

59 BASIC BIOLOGICAL SCIENCES↗

PVwindow (Photovoltaic Window Simulator) [SWR-22-01]

PVwindow simulates photovoltaic window properties by allowing the user build stacks of thin film materials that compose the window layers. The only needed inputs are the complex refractive indices and thicknesses of the materials. The software will simulate the optical transmission, front reflection, and back reflection of the stack using the transfer matrix method. Properties specific to PV window optics such as visible transmittance and color are also calculated. The optics code extracts the number of absorbed photons in the PV absorber layer and solves the single diode equation to yield theoretical photovoltaic metrics such as power conversion efficiency, fill factor, open circuit voltage, and short circuit current of the PV window when illuminated at an arbitrary angle or from either side of the stack. The software tool ultimately allows researchers to design photovoltaic windows and simulate their properties. The software also exports files that can be read into LBL Window software or into the EnergyPlus and Open Studio building energy modeling software to determine larger scale energy impacts of PV window integration.

Wheeler, Lance↗

Deep Design Data Portal (D3P) v0.01

The Deep Design Data Portal (D3P) tool was developed to demonstrate how readily accessible data sources, such as building energy model reports for design and baseline energy performance data for projects, can provide the data required for reporting to an industry initiative (AIA 2030 commitment), as well as more detailed data that makes the industry dataset more valuable to all stakeholders, enabling project level analysis and analysis of BEM industry trends. D3P provides an easier and less time-consuming way for firms to auto-extract data from this data source, compared to the current reporting workflows of the firms. The BEM reports are the first of several data sources that D3P could integrate. D3P also provides the ability for firms to review, compare, and evaluate the performance of their projects to not only their portfolio, but also to the larger anonymized industry dataset created each time a project is added to D3P. The intent of D3P is to become part of a data-sharing ecosystem to assist creating large anonymized industry datasets that are accessible to industry.

Regnier, Cynthia [Lawrence Berkeley National Labor↗

Evaluating the performance of WRF urban schemes and PBL schemes over Dallas-Fort Worth during a dry summer and a wet summer

This study evaluated the Weather Research and Forecasting (WRF) model sensitivity to different planetary boundary layer (PBL) schemes (the YSU and MYJ schemes) and urban schemes including the bulk scheme (BULK), single-layer urban canopy model (UCM), multi-layer building environment parameterization (BEP) model, and multi-layer building energy model (BEM). Daily reinitialization simulations were conducted over Dallas-Fort Worth during a dry summer month (July 2011) and a wet summer month (July 2015) with weaker (stronger) daytime (nocturnal) UHI in 2011 than 2015. All urban schemes overestimated the urban daytime 2m temperature in both summers, but BEP and BEM still reproduced the daytime urban cool island in dry summer. All urban schemes reproduced the nocturnal urban heat island, with BEP producing the weakest one due to its unrealistic urban cooling. BULK and UCM overestimated the urban canopy wind speed, while BEP and BEM underestimated it. The urban schemes showed prominent impact on daytime PBL profiles. UCM+MYJ showed a superior performance than other configurations. The relatively large (small) aspect ratio between building height and road width in UCM (BEM) was responsible for the overprediction (underprediction) of urban canopy temperature. The relatively low (high) building height in UCM (BEM) was responsible for the overprediction (underprediction) of urban canopy wind speed. Improving urban schemes and providing realistic urban parameters were critical for improving urban canopy simulation.

54 ENVIRONMENTAL SCIENCES↗

Soil Water Potentials (1990-2018) from a calibrated ELM-FATES, and rooting depth analyses scripts, PA-BCI, Panama

This dataset has ELM-FATES simulation outputs and scripts that accompany and reproduce the manuscript, Chitra-Tarak et al. (2021) Hydraulically-vulnerable trees survive on deep-water access during droughts in a tropical forest. New Phytologist. https: //doi.org/10.1111/nph.17464”. This dataset is organized into four parts: (1) source code for the model, Energy Exascale Earth System Land Model-Functionally Assembled Advanced Terrestrial simulator (ELM-FATES) (2) R scripts associated with ELM-FATES simulations: to prepare files for parameter ensemble simulation runs, calibrate the model with observed hydrological fluxes observed at BCI, re-run the model with tuned parameters and obtain long-term soil matric potentials by depth (3) ELM-FATES hydrological simulation outputs at PA-BCI, Panama (1990-2018, daily), and (4) R scripts for inverse rooting depth modeling and post-processing: prepare datasets and inversely model tree rooting depths at BCI, test hypotheses about the relationship of rooting depths with plant hydraulic traits and drought-induced mortality, and reproduce the manuscript itself. n.b. 1. Data needed to run R scripts in (2) and (4) and thus to reproduce the manuscript are sourced from various public datasets. Refer to the data availability section of the accompanying manuscript. 2. This dataset version (prepared on May 12, 2021) matches the revised and published version of the accompanying manuscript (published May 16, 2021) replacing a previous version. In the publication, this dataset is cited as follows: Chitra-Tarak R, Xu C, Aguilar S, Anderson-Teixeira K, Chambers J, Detto M, Faybishenko B, Fisher R, Knox R, Koven C et al. 2020. Soil water potentials (1990–2018) from a calibrated ELM-FATES, and rooting depth analyses scripts, PA-BCI, Panama. 2.0. NGEE Tropics Data Collection. doi: 10.15486/ngt/1696806

54 ENVIRONMENTAL SCIENCES↗

Methodology to assess “no-touch” building audit software using simulated utility data

Building audits are conducted in many commercial buildings to identify opportunities to reduce energy costs and improve building operation. Because audits require significant effort by building engineers, they are usually only affordable for larger commercial buildings. “No-touch” building audit tools have thus been developed to identify potential savings based on a simplified analysis of building energy consumption patterns via high-level energy data such as monthly utility bills. This paper presents a comprehensive and standardized methodology to evaluate the accuracy of no-touch audit tools in detecting and diagnosing building energy problems and quantifying potential energy savings. The test suite is based on output data from a well-characterized set of building energy models, and the methodology is illustrated by applying it to a representative no-touch building audit tool. Results show that the tool estimates building energy end uses with reasonable accuracy but is less accurate in identifying probably causes of high energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring the Energy Consumption and Efficiency of Deep Neural Networks: An Empirical Analysis and Design Recommendations

Addressing the "Red-AI" trend of rising energy consumption by large-scale neural networks, this study investigates the measured energy consumption of training various fully connected neural network architectures. We introduce the BUTTER-E dataset, an augmentation to the BUTTER Empirical Deep Learning dataset, containing energy consumption and performance data from 41,129 individual experimental runs spanning 30,582 distinct configurations: 13 datasets, 20 sizes (trainable parameters), 8 "shapes", and 14 depths on both CPUs and GPUs using node-level watt-meters. This dataset reveals the complex relationship between dataset size, network structure, and energy use. Our analysis uncovers a surprising, hardware-mediated non-linear relationship between energy efficiency and network design, challenging the assumption that reducing the number of parameters or FLOPs is the best way to achieve greater energy efficiency. We propose a straightforward and effective energy model that accounts for network size, computing, and memory hierarchy. Highlighting the need for cache-considerate algorithm development, we suggest a codesign approach to energy efficient network, algorithm, and hardware design. This work contributes to the fields of sustainable computing and Green AI, offering practical guidance for creating more energy-efficient neural networks and promoting sustainable AI.

97 MATHEMATICS AND COMPUTING↗

Elaboration of Energy Balance: A Model for the Brazilian States

The energy balance constitutes a powerful management instrument for government agencies, as it offers an overview of the energy situation of the country (or region) and serves as a guide for energy policies and monitoring of these policies. Although Brazil has published the national energy balance for more than half a century, the national publication does not adequately address energy statistics at the level of the states. This occurs either due to the lack of specific data or the absence of total disaggregation. Accordingly, the elaboration and implementation of public policies for the energy sector in the Brazilian states lack consistent energy statistics. Therefore, this paper aims to present a model for the Brazilian states to elaborate the energy balance. The proposed model consists of applying internationally referenced methodologies to develop a user-friendly software, which includes automatic energy unit conversions, different chart styles, high-level data organization, and Sankey diagrams. As a result, the software can be adopted by local governments as a tool to maintain the state energy balance publication periodically, and hence obtain the detailed information necessary to manage and formulate energy policies. The advantage of the software is that it can be operated by non-experts and the energy flow as well as the entire report can be generated automatically. The proposed software was successfully used to generate the energy balance of the Mato Grosso do Sul state.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Residential and Office Building Archetypes for Energy Efficiency Building Solutions in an Urban Scale: A China Case Study

Building energy consumption accounts for 36% of the overall energy end use worldwide and is growing rapidly as developing countries continue to urbanize. Understanding the energy use at urban scale will lay the foundation for identification of energy efficiency opportunities to be deployed at speed. China has almost half of global new constructions and plays an important role in building suitability. However, an open source national building energy consumption database is not available in China. To provide data support for building energy consumptions, this paper used a simulation method to develop an urban building energy consumption database for a pilot city in Wuhan, China. First, residential, small, and large office building archetype energy models were created in EnergyPlus to represent typical building energy consumption in Wuhan. The baseline reference model simulation results were further validated using survey data from the literature. Second, stochastic simulations were conducted to consider different design parameters and occupants’ energy usage intensity scenarios, such as thermal properties of the building envelope, lighting power density, equipment power density, HVAC (heating, ventilation and air conditioning) schedule, etc. A building energy consumption database was generated for typical building archetypes. Third, data-driven regression analysis was conducted to support quick building energy consumption prediction using key high- level building information inputs. Finally, a web-based urban energy platform and an interface were developed to support further third-party application development. The research is expected to provide fast energy efficiency building design solutions for urban planning, new constructions as well as building retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deriving Simulation Parameters for Storage-Type Water Heaters Using Ratings Data Produced from the Uniform Energy Factor Test Procedure: Preprint

Building energy modeling (BEM) is commonly used to estimate the energy usage of residential buildings. Uses for BEM include calculating home energy ratings, demonstrating compliance with performance-based energy codes, and establishing whether designs meet voluntary program requirements, such as ENERGY STAR® qualified homes. BEM requires simulating subsystems within the building, including storage-type water heaters. To properly simulate the in-situ performance of residential storage water heaters, it is necessary to determine key water heater parameters, including the overall heat loss coefficient (UA) and conversion efficiency (?c) of the water heater, based on the rated efficiency of the water heater. The testing procedure and rating standard for residential water heaters have recently changed: the new rating standard provides a Uniform Energy Factor (UEF) rather than the Energy Factor (EF) used previously. This paper discusses how to derive the necessary model parameters from the ratings data produced from the latest test procedure.

30 DIRECT ENERGY CONVERSION↗

Empirical validation and comparison of methodologies to simulate micro and macro-encapsulated PCMs in the building envelope

Thermal Energy Storage (TES) has the potential to shift peak electricity demand. Passive TES is usually implemented in building envelope as micro and macro encapsulated phase change materials (PCM) to shift electric energy demand and therefore requires careful heat transfer analysis. Whole building energy modelling with simplified heat transfer analysis has become extremely important for designers, architects, engineers, and researchers to predict energy performance of buildings. It is important to validate PCM modelling algorithms used in building energy programs to quantify their error and prove their capacity to model different PCM encapsulation types. This study uses data from a microencapsulated PCM and two macroencapsulated PCMs (Bio based PCM and hydrate salts) tested in full-scale using the Advanced Multiscale Building Energy Research (AMBER) Lab located at the Colorado School of Mines and is used to validate a numerical algorithm written in MATLAB language. To approximate the heat transfer through a wall assembly with macroencapsulated PCM pouches, several modelling techniques that can reduce 3D heat transfer characteristics to 1D are explored in this research. A parallel path heat transfer modelling approach is found to give the closest agreement with the experimental data for the pouched PCMs in building envelope applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Service Values of Generic Marginal Building Flexibility in Modeled 2030 U.S. Power Systems

The datasets include the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of generic, daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. The results should be interpreted along with the caveats listed in "Valuation of Building Flexibility: Grid Service Value for Initial Market Entrants in Projected 2030 United States Power Systems", which also documents the methods used for the study. The factors examined in the study include: grid scenario, region, original usage hour in the day (local time), and building flexibility parameters - efficiency, dissipation, and shifting window include max pre-shift and max post-shift. Filenames in the datasets: The filenames contain information on the grid scenario, and the building flexibility efficiency and dissipation. For example: MidCase_2030_efficiency1.25_dissipation0.05_value.csv contains all results under Mid RE 2020, efficiency = 1.25, and dissipation = 0.05. * MidCase = Mid RE Each .csv file contains: region: The location of the building flexibility, aligned with U.S. Energy Information Administration (EIA) National Energy Modeling System (NEMS) Electricity Market Module regions. max_pre_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift earlier. max_post_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift later. local_datetime: Original datetime of 1kWh of building energy consumption. local_orig_h: Original usage hour (1-24) of building energy consumption, ignores daylight saving. local_shift_to: The datetime to when building energy consumption shifts, if shifting happens. If no shifting occurs, this cell is left blank. energy: Net energy value of energy shifting. capacity: Net capacity value of energy shifting. shifting_value: Net energy plus capacity value of energy shifting. spin: Spin reserve value at the original datetime of consumption. flex: Flexible reserve value at the original datetime of consumption. reg: Regulation reserve value at the original datetime of consumption. total_profit: Assuming the building flexibility is capable of providing energy, capacity, and ancillary services, total profit is the maximum value of energy shifting value, spin reserve value, flexible reserve value, and regulation reserve value - one of the four choices at any given hour - because we do not allow its value to be double-counted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗