Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy analysis at scale”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Electrochemical leaching of spent LIBs: Kinetics, novel reactor, and modeling

The use of electrons as main reagent for the recovery and recycling of critical metals from spent lithium-ion batteries (LIBs) is a process electrification strategy that can be used to close the life-cycle loop of LIBs through more sustainable methods. Electrochemical leaching, a process that uses a reductant that is constantly regenerated electrochemically for the leaching of lithium-ion battery black mass (LIBBM), has shown high extraction efficiencies and sustainable scores. However, slow kinetics, reactor design challenges and lack of deeper understanding of the underlying processes are barriers to the optimization, scale-up, and market adoption of this technology. In this paper, a kinetic study and mathematical model for dissolving LIBBM is presented to better understand the underlying mechanisms aiming to reduce the processing time and make predictions for future design and scale-up. The effect of acid and electrochemically mediated reductant concentrations, LIBBM loading, and cathode/reactor designs were explored. As a result, the leaching time was reduced from 7h to under 1h at a pulp density of 73 g/L, without external heating. A novel reactor with parallel baffle electrodes (PBE) was developed, which significantly reduced the leaching time by improving convection in a stirred slurry electrochemical reactor. Dimensionless numbers were deduced from an unsteady state model, which can be used in dimensional analysis for future process design and scale-up.

25 ENERGY STORAGE↗

Modeling District Heating and Cooling Systems with URBANopt, GeoJSON to Modelica Translator, and the Modelica Buildings Library

The URBANopt project has successfully leveraged OpenStudio/EnergyPlus to model buildings and electrical systems at an urban scale; however, URBANopt has lacked the ability to model district thermal energy systems until recently. This paper will present the modeling infrastructure that was developed specifically for the analysis of district heating and cooling systems, and how it is integrated into the existing URBANopt framework. The paper also discusses the development of new models added to the Modelica Buildings Library to model various district energy system components including loads, energy transfer stations (ETS), distribution networks, and central plants. The paper describes how different building loads can be modeled including time series, TEASER reduced-order models, or Spawn of EnergyPlus models. URBANopt District Energy Systems allows the user to switch between the various configurations.

district heating and cooling↗

A charged particle transport approximation for thick and thin plasmas

In this work, we will construct a simple method to be utilized in the interpretation of the properties of a thin plasma from a study of the transport of charged particles through it. We do so by first demonstrating how charged particle fluxes encode local plasma information in their spectra for sufficiently thick plasmas and then propose how to extend that analysis to the thin plasma limit where the extensive geometry cannot be neglected through arguments from scale separation. We provide a numerical treatment of the transport problem and demonstrate that it is in good agreement with the approximation we present. Finally, we utilize both the numerical solution and our novel approximation to study the impact of the extensive scale of the plasma on the yield and flux normalized high-energy neutron spectra resulting from the upscattering of charged fuel ions. Using this analysis, we show that (after controlling for fusion yield) for the same uniform densities and temperatures, larger plasmas have higher magnitude but softer reaction-in-flight (RIF) neutron spectra relative to smaller plasmas. This is because larger plasmas retain more knocked-on suprathermal ions within their bulk and can downscatter them to lower average energies, while smaller plasmas allow a larger fraction of high energy particles to “range out” of the system prior to substantial downscattering or inducing an RIF reaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multifamily Building Stock Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-17-00701

U.S. multifamily buildings house 35 million households, consuming 4 quads of source energy and spending $48 billion on utility bills every year. Almost all of these households live in urban areas, where cities are taking the lead on setting aggressive energy goals. Cities currently do not have the data and tools necessary to identify and target opportunities to save energy in their building stock. Building on the open-source, OpenStudio-based ResStock platform, this project will extend the publicly-available ResStock modeling capabilities to the multifamily sector, enabling Radiant Labs, and others, to partner with cities to market and strategically deploy cost-effective, energy efficiency (EE) upgrades directly to high-priority households. Radiant Labs has been successful in using ResStock's single-family capabilities to provide value to the City of Boulder, Colorado. However, lack of multifamily capabilities in ResStock is a roadblock for Radiant Labs working with New York City, San Francisco, Washington, D.C., and other cities that have expressed significant interest in working with them. In addition, other cities, companies, and utilities can use these open-source capabilities to grow their EE portfolios, thereby multiplying the impact of this project. This work also enables national-scale analysis of EE potential in multifamily buildings, which is of strong interest to a variety of stakeholders, including the U.S. Department of Energy (DOE) Office of Energy Policy and Systems Analysis (EPSA), DOE Weatherization Assistance Program (WAP), U.S. Department of Housing and Urban Development (HUD), and the Bonneville Power Administration (BPA).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards quantum simulations in particle physics and beyond on noisy intermediate-scale quantum devices

We review two algorithmic advances that bring us closer to reliable quantum simulations of model systems in high-energy physics and beyond on noisy intermediate-scale quantum (NISQ) devices. The first method is the dimensional expressivity analysis of quantum circuits, which allows for constructing minimal but maximally expressive quantum circuits. The second method is an efficient mitigation of readout errors on quantum devices. Both methods can lead to significant improvements in quantum simulations, e.g. when variational quantum eigensolvers are used. This article is part of the theme issue ‘Quantum technologies in particle physics’.

Science & Technology - Other Topics↗

Energy Storage in South Asia: Understanding the Role of Grid-Connected Energy Storage in South Asia’s Power Sector Transformation

During the last decade, the cost of energy storage technologies, primarily lithium-ion battery energy storage systems (BESS), has declined rapidly and is projected to decline further over the next decade. This study provides a first-of-its-kind assessment of cost-effective opportunities for grid-scale energy storage deployment in South Asia both in the near term and the long term, including a detailed analysis of energy storage drivers, potential barriers, and the role of energy storage in system operations. We conduct scenarios-based capacity expansion modeling to assess when, where and how much energy storage can be cost-effectively deployed in India through 2050. The analysis relies on state-of-the-art modeling approaches to uncover and compare the value streams of battery storage with different durations as well as pumped storage hydropower. We also run hourly simulations of system operations in 2030 and 2050 to understand how energy storage will be utilized by system operators to help integrate RE and reduce operating costs. For Bangladesh, Bhutan, and Nepal, we use operational simulations to explore how increasing deployment of energy storage can help optimize the use of domestic resources and cross-border electricity trade.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Exploring Decarbonization and Clean Energy Pathways for Disadvantaged Communities in California

California has a state-wide goal of carbon neutrality by 2045. Decarbonization for disadvantaged communities (DACs) poses extra challenges due to financial, informational, language, and other barriers. This paper presents the methodology, results, and analysis of energy efficiency measures (EEMs) to save energy, reduce CO 2 emission, and promote clean energy access at the district scale for two DACs in Fresno, California. The methods are broadly applicable to other neighborhoods across the U.S. 22 EEMs were identified and modelled for all residential buildings in the two DACs both individually and as packages. Results show that for energy and CO 2 reduction purposes, the top performing EEM package can decrease energy use and CO 2 emissions by an average of 60%. For electrification, heat pump water heaters are a viable solution, coupled with air source or mini-split heat pumps. Replacing gasoline vehicles with electric vehicles is another important measure in electrification and reducing GHG emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Overview of NASA aeronautical propulsion research and technology program

The program discussed is aimed at improving performance within an extended operating range, reducing weight, increasing service life, achieving greater cost effectiveness, reducing noise and exhaust pollution, and improving means of energy conservation. The program places emphasis on basic research in numerous related technical disciplines, system analysis, component technology, full scale propulsion system studies, and technology demonstrations. Much attention in the discussion is given to noise and pollution minimization research.

Johnson, H. W.↗

Life cycle energy demand and carbon emissions of scalable single-junction and tandem perovskite PV

Perovskite photovoltaics reached record efficiencies in the laboratory and, if sustainably commercialized, they would accelerate a green energy transition. Here, this article presents the development of life-cycle inventory material and energy databases of most promising four single-junction and three tandem scalable perovskite systems with assumptions regarding scalable production validated by industry experts. We conducted comprehensive “ex ante” Life Cycle Analysis (LCA) and Net Energy Analysis, analyzing their cumulative energy demand, global warming potential profiles, energy payback times and energy return on investment (EROI). LCA contribution analysis elucidates the most impactful material and process choices. It shows that solution-based perovskite manufacturing would have lower environmental impact than vapor-based methods, and that roll-to-roll (RtR) printing offers the lowest impact. Among material choices, MoOx/Al has lower impact than Ag, and fluorine-tin-oxide lower than indium-tin-oxide. Furthermore, we compare perovskites with commercial crystalline-silicon and thin-film PV, accounting for the most recent developments in crystalline-Si wafer production and differences in life expectancies and efficiencies. It is shown that perovskite systems produced with RtR manufacturing could reach in only 12 years of life the same EROI as that of single-crystalline-Si PV lasting 30-years. This work lays a foundation for sustainability investigations of perovskite large-scale deployment.

14 SOLAR ENERGY↗

Obstruction and Interference in Low-Energy Models for Twisted Bilayer Graphene

The electronic bands of twisted bilayer graphene (TBLG) with a large-period moiré superlattice fracture to form narrow Bloch minibands that are spectrally isolated by forbidden energy gaps from remote dispersive bands. When these gaps are sufficiently large, one can study a band-projected Hamiltonian that correctly represents the dynamics within the minibands. This inevitably introduces nontrivial geometrical constraints that arise from the assumed form of the projection. Here we show that this choice has a profound consequence in a low-energy experimentally observable signature that therefore can be used to tightly constrain the analytic form of the appropriate low-energy theory. Additionally, we find that this can be accomplished by a careful analysis of the electron density produced by backscattering of Bloch waves from an impurity potential localized on the moiré superlattice scale. We provide numerical estimates of the effect that can guide experimental work to clearly discriminate between competing models for the low-energy band structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scaling properties of direct photon yields in heavy ion collisions

Abstract A recent analysis from the PHENIX collaboration of available direct photon measurement results in collisions of various systems such as Au+Au, Cu+Cu, and Pb+Pb, at different beam energies ranging from 39 to 2760 GeV, has shown a universal, within experimental uncertainties, multiplicity scaling, in which direct photon $$p_{T}$$ p T -spectra for transverse momenta up to 2 GeV/ c are scaled with charged hadron pseudorapidity density at midrapidity raised to power $$\alpha =1.25$$ α = 1.25 . On the other hand, those direct photon $$p_{T}$$ p T -spectra also exhibit geometrical scaling in the similar $$p_{T}$$ p T range. Assuming power-law dependence of the scaled photon spectra for both scaling laws, we formulate two independent conditions for the power $$\alpha $$ α , which overshoot experimental data by $$\sim 10\%$$ ∼ 10 % on average. We discuss possible sources that might improve this estimate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Importance of Multiplicity Fluctuations in Entropy Scaling

One of the greatest uncertainties in heavy-ion collisions is the description of the initial state. Different models predict a wide range of initial energy density distributions based on their underlying assumptions. Final flow harmonics are sensitive to these differences in the initial state due to the nearly linear mapping between eccentricities and anisotropic flow harmonics. The Trento code uses a model-agnostic approach by phenomenologically parameterizing the initial state and constraining those parameters from a Bayesian analysis. There the multiplicity fluctuations were determined by a one parameter Γ distribution. However, initial-state models arising from the Color-Glass Condensate (CGC) framework lead to an initial energy density which is outside the functional form considered in Trento and its later Bayesian analyses because they rely on log-normal multiplicity fluctuations. We compare T A T B scaling (CGC-like) to √T A T B scaling (preferred from a Trento Bayesian analysis) and find that the T A T B form together with log-normal fluctuations is a reasonable candidate to describe the multiplicity fluctuations but leads to larger eccentricities, which would affect the extraction of viscosity in small systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nonlinear Effects in Single-Pass ICRF Heating

The Variable Specific Impulse Magnetoplasma Rocket (VASIMR) concept employs Ion Cyclotron Resonant Frequency (ICRF) heating as the main power deposition mechanism. Since the ions accelerate to the full energy in a single pass through the cyclotron resonance, their response to the RF-field will be essentially nonlinear - hence the motivation to amend the commonly used linear approach to the problem. In a collisionless plasma, the energy gain of an accelerated ion is limited by the time the particle spends at the resonance. This time is affected by: (1) incident flow velocity, (2) longitudinal grad B force, (3) ambipolar electric field, and (4) ponderomotive force of the RF-field. Our analysis shows that the grad B force is the dominant factor at low to moderate levels of RF-power. We present nonlinear scaling for the energy gain and the absorption efficiency with RF-power and plasma parameters. We also demonstrate that the nonlinear regime exhibits a steep decrease in the plasma density at the resonance.

Arefiev, A. V.↗

Development of the MPACT 69-group Library for Magnox Reactor Analysis using CASL VERA

The Consortium for Advanced Simulation of Light Water Reactors (CASL) has developed the CASL toolset, Virtual Environment for Reactor Analysis (VERA), for pressurized water reactor (PWR) analysis. Recently the CASL VERA was improved for Magnox reactor analysis, which required the development of a new cross section library and new geometrical and thermal feedback capabilities for graphite-moderated Magnoxreactors. The MPACT neutronics module of the CASL core simulator is a 3D whole core transport code, which requires a new cross section library with a different energy group structure due to the different neutronic characteristics of Magnox compared with PWR. A new 69-group structure was developed based on the MPACT 51-group structure to have more thermal energy groups and to be a subset of the SCALE 252-group structure. The ENDF/B-VII.1 MPACT 69-group library was developed for Magnox reactor analysis using the SCALE/AMPX and VERA-XSTools for which a super-homogenization method was applied, and transport cross sections were generated for graphite using a neutron leakage conservation method. Benchmark results show that new MPACT 69-group library works reasonably well for Magnox reactor analysis.

Kim, Kang Seog↗

How close are urban scale building simulations to measured data? Examining bias derived from building metadata in urban building energy modeling

Residential and commercial buildings in the United States accounted for 40% of total energy in 2020. Building energy modeling (BEM) is a useful tool that allows individuals, researchers, companies, or utilities to save energy by optimizing buildings through estimation of building technology savings and performance projection of building energy under various environmental conditions. Urban building energy modeling (UBEM) expands the scope beyond individual buildings to the buildings in a neighborhood, city, utility and more. Yet there is a knowledge gap in the literature as to how these models compare to measured data on an individual and aggregated basis. As UBEM data and methods continue to develop, it is important to consider the accuracy, bias, and limitations of the models. Here, nation-scale data and UBEM software suite named Automatic Building Energy Modeling (AutoBEM) was used to model 50,843 buildings in Chattanooga, Tennessee. The uncalibrated simulation results were compared to aggregated 15-minute electricity data for the year 2019 with visualizations highlighting sources of bias in building data and the AutoBEM framework while considering how they relate to other UBEM methods. Estimation of building type and year of constructions are found to be the major sources of bias. Accounting for the amount of conditioned area per building significantly improves the overall fit of the simulated energy use intensity. it was found that inherent variation in building energy use contributes to R 2 values between 0.008 and 0.095 across building types but slope values near 1 for the total number of buildings. This indicates the need for building aggregation for representative building energy modeling with data sources available at an urban scale while illustrating the need for additional individual building data and model improvement beyond the originally produced UBEM models for individual building analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Analysis of a Thermophotovoltaic Integrated Self-Powered Furnace

This work investigates the energy efficiency and carbon reduction potential of self-powered residential building heating equipment using a thermodynamic modeling approach. An integrated thermophotovoltaic power module and residential scale furnace system (40,000 Btu/h) were modeled and studied in detail to assess the influence of different design configurations on primary energy efficiency. Operational characteristics such as total power generation, electrical efficiency, and heat recovery were examined in a self-powered system configuration. A sensitivity analysis was conducted to determine the influence of the electric grid’s carbon dioxide footprint (carbon intensity) and the cost of electricity on the environmental, as well as the economic, benefit associated with the self-powered configuration. Compared with a traditional furnace powered by an electric grid at a carbon intensity of 0.5 kg CO 2eq /kWh EL , the self-powered furnace was shown to decrease the annual carbon dioxide emissions by approximately 550 kg (~75% reduction), while also saving more than USD 200 in utility expenses, annually. Additionally, the carbon emission reduction potential of blending different concentrations of hydrogen in natural gas fuel was also studied.

14 SOLAR ENERGY↗

Computed Tomography Scanning and Geophysical Measurements of the Patterson #5-25 Well in Western Kansas

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) site in Morgantown, West Virginia, were used to characterize core from the Patterson Field site. This core came from a vertical well (Patterson #5-25 well) that was obtained as part of the U.S. Department of Energy (DOE) sponsored Integrated Midcontinental Stacked Carbon Storage Hub. The primary impetus of this work is a collaboration between NETL and the Kansas Geological Survey to characterize core from the Patterson Field site. The 625 ft of whole core from the Atoka Formation to Precambrian Basement was characterized at NETL. As part of this effort, bulk scans of core were obtained. This report, and the associated scans, provide detailed datasets not typically made publicly available for carbon capture utilization and storage analysis. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/patterson-5-25-well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL are useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

Final Technical Report

Statement of the problem or situation that is being addressed in your application. The DOE and its national laboratories developed the Home Energy Score™ (HES) to encourage homeowners to improve their energy performance, lower costs and to share energy information through the MLS listing, appraisal, and financing channels. While the HES is an instrumental tool, it is currently underutilized and consists of technical, structural and sector barriers which need to be addressed in order to scale and many energy efficiency contractors are understandably overwhelmed by the added time and effort and lack of incentive to sell and deliver deep retrofit projects while simultaneously meeting the DOE HES program requirements; consequently, contractors may decide to forgo participation. Home Energy Rating System (HERS) Raters have the opportunity to play the critical Assessor role in producing a Home Energy Score (HES); this role has immense potential but currently is unfulfilled. Lastly, while utilities are interested in their customer base achieving greater energy efficiency, especially to help offset growing residential loads in states like California that are accelerating electrification, utilities do not have access to the market actors who are on the front line of influence to homeowners or review and approve their permits: HERS Raters, assessors, contractors and building departments. General statement of how this problem is being addressed: ConSol will integrate the Home Energy Score™ (HES) to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California (CHEERS+HES). The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the utilities in supporting existing homes in their jurisdictions with HES and develop measures to improve energy efficiency and reduce emissions. How is this problem being addressed? What is the overall project approach? In effort to expand the Home Energy Score™ (HES) by increasing the use of aggregable home energy asset data, ConSol proposes to integrate the DOE HES via Application Programming Interface (API) to its State of California approved home energy rating services platform (CHEERS). Once the CHEERS platform and HES are integrated (CHEERS+HES), this enhanced platform will be instantly available and actively deployed via Phase 1 pilot to HERS Raters, assessors and contractors in California to market-test the solution, understand the rate of adoption and identify opportunities for improvement prior to scaling nationally. The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the building industry and homeowners with an easy-to-use assessment if energy and carbon impacts of existing homes, and assist the utilities in supporting existing homes in their jurisdictions with HES to improve energy efficiency and reduce emissions. What is to be done in Phase I? During Phase I of this proposed project, ConSol will (1) design software architecture that links CHEERS to the Home Energy ScoreTM via API, (2) solicit partnership from one or more California utilities for a regional pilot, (3) test the new software with its HERS Raters and contractor network in the partnership utility jurisdiction, (4) launch a pilot version of the newly developed software with HERS Raters and contractors in the utility territory, and (5) explore California’s GoGreen energy efficiency homeowner lending program in parallel with the pilot. Commercial Applications and Other Benefits. Summarize the future applications or public benefits if the project is carried over into Phase II or Phase III and beyond. The CHEERS+HES commercialized product will be ready for national market scale following a successful Phase 1 performance. The CHEERS+HES adoption is estimated to reach a 5% adoption growth rate versus the 110,000 baseline, starting in Year 1 after Phase I completion, and continuing each year. As a direct benefit to the DOE, CHEERS will set a goal of 100,000 Home Energy Score assessments for existing home alterations within the first 10 years following Phase 1 performance. The technical benefits of this proposed project include the harmonized, automated, and seamless integration of the DOE HES into the widely used and market leading California energy registry, CHEERS. The social benefits include the aggregate energy, cost and GHG savings by allowing the broader public streamlined access to the CHEERS+HES measurement and the energy efficiency recommended measures that may result. Key Words: Home Energy ScoreTM (HES); Application Programming Interface (API); Home Energy Rating Services (HERS); HERS Raters; contractors; assessors; existing homes, energy asset data; cost, energy, and emissions saving measures; energy code (Title 24) compliance; document repository; utilities; pilot; newly developed software; energy efficiency; homeowner. Summary for Members of Congress: The DOE Home Energy Score™ (HES) is a tool to encourage homeowners to improve their energy performance, lower costs and share energy information but is underutilized and consists of barriers which need to be addressed in order to scale. In effort to expand the HES, CHEERS, Inc. will integrate the HES to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California.

Application Programming Interface (API)↗