Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise Evaluation of Various High-gain, Very-low-noise Current Sense Amplifier Circuits

We report an evaluation of three different electronic topologies for a high-gain, very-low-noise current sense amplifier (CSA) for use in remote sensing applications. The circuits in question were built from commercially available parts and were evaluated for their performance in an interface to a photodetector used in NASA’s Lunar Flashlight infrared spectrometer spacecraft. Through constraints on the test environment, we were able to reduce the impact of systematic noise sources by making them common mode to the measurement. The parts compared were based on the ADA4530-1, the LTC6240, and the LSK389A. We determined which of the three different versions of the CSA had superior noise performance for selection for use on the instrument. Two tests and simulations of each board compare and contrast functionality and performance, both qualitatively and quantitatively, and based on those results, we show that the ADA4350-1 out-performed the opposing components.

Foor, David↗

A New Method for Reduction of Photomultiplier Signal-Induced Noise

For lidar measurements of ozone, photomultiplier tube (PMT) detector signal-induced noise represents a fundamental problem that complicates the extraction of information from lidar data. A new method is developed to significantly reduce signal-induced noise in lidar receiver PMT detectors. The electron optics of the lidar photomultiplier detector is modified to filter the source of signal-induced noise. A mesh electrode external to the PMT is utilized to control photoemission and disorient electron trajectories from the photocathode to the first dynode. Experiments were taken both with simulated and actual lidar return signals at Langley Research Center. Results show at least 40 percent more accurate ozone number density values with a mesh voltage of 60 V applied than with no voltage applied.

Koble, Andrea↗

Electron plasma waves upstream of the earth's bow shock

Electrostatic waves are observed around the plasma frequency fpe in the electron foreshock, together with electrons backstreaming from the bow shock. Using data from the sounder aboard ISEE 1, it is shown that this noise, previously understood as narrow band Langmuir waves more or less widened by Doppler shift or nonlinear effects, is in fact composed of two distinct parts: one is a narrow band noise, emitted just above fpe, and observed at the upstream boundary of the electron foreshock. This component has been interpreted as Langmuir waves emitted by a beam-plasma instability. It is suggested that it is of sufficiently large amplitude and monochromatic enough to trap resonant electrons. The other is a broad band noise, more impulsive than the narrow band noise, observed well above and/or well below fpe, deeper in the electron foreshock. The broad band noise has an average spectrum with a typical bi-exponential shape; its peak frequency is not exactly equal to fpe and depends on the Deybe length. This peak frequency also depends on the velocity for which the electron distribution has maximum skew. An experimental determination of the dispersion relation of the broad band noise shows that this noise, as well as the narrow band noise, may be due to the instability of a hot beam in a plasma.

Lacombe, C.↗

Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer

A multi-channel electrometer voltmeter that employs self-nulling lock-in detection electronics in conjunction with a mechanical resonator with noncontact voltage sensing electrodes has been developed for space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM). The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Use of an AC-coupled lock-in amplifier with closed-loop sense-signal nulling via generation of an active guard-driving feedback voltage provides the resolution, accuracy, linearity and stability needed for long-term space-based measurement of the IESDM. This implementation relies on adjusting the feedback voltage to drive the sense current received from the resonator s variable-capacitance-probe voltage transducer to approximately zero, as limited by the signal-to-noise performance of the loop electronics. The magnitude of the sense current is proportional to the difference between the input voltage being measured and the feedback voltage, which matches the input voltage when the sense current is zero. High signal-to-noise-ratio (SNR) is achieved by synchronous detection of the sense signal using the correlated reference signal derived from the oscillator circuit that drives the mechanical resonator. The magnitude of the feedback voltage, while the loop is in a settled state with essentially zero sense current, is an accurate estimate of the input voltage being measured. This technique has many beneficial attributes including immunity to drift, high linearity, high SNR from synchronous detection of a single-frequency carrier selected to avoid potentially noisy 1/f low-frequency spectrum of the signal-chain electronics, and high accuracy provided through the benefits of a driven shield encasing the capacitance- probe transducer and guarded input triaxial lead-in. Measurements obtained from a 2- channel prototype electrometer have demonstrated good accuracy (|error| < 0.2 V) and high stability. Twenty-four-hour tests have been performed with virtually no drift. Additionally, 5,500 repeated one-second measurements of 100 V input were shown to be approximately normally distributed with a standard deviation of 140 mV.

Blaes, Brent R.↗

A Review of Infrared Readout Electronics for Space Science Sensors

A review of infrared readout electornics for space science sensors is presented. General requirements for scientific IR FPA readout are discussed. Specific approaches to the unit cell electronics are described with respect to operation, complexity, noise and other operating parameters. Recent achievements in IR FPA readout electronics are reviewed. Implementation technologies for realization of IR FPA readout electronics are discussed. Future directions for addressing NASA and other scientific users' needs are suggested.

Infrared Readout Electonics↗

Evaluation of GaAs FETs for cryogenic readout

Low-frequency, low-noise, low-power cryogenic electronics to read out photodetectors is being investigated for the star-tracking telescope of the Gravity Probe B spacecraft. We report our initial findings from evaluating more than 20 types of GaAs FETs, both commercial and non-commercial, for this application. Most exhibit useable dc characteristics at cryogenic temperatures, although gate leakage and hysteretic effects (presumably due to charge trapping) could be troublesome. Low-frequency noise (based primarily on grounded-gate measurements) at 4 K is '1/f-like' and for the quietest GaAs FETs appears to be at least as low as the lowest noise values reported for Si MOSFETs at 4 K. Further investigation is needed in several areas.

Kirschman, Randall K.↗

Focal plane arrays for submillimeter waves using two-dimensional electron gas elements: A grant under the Innovative Research Program

This final report describes a three-year research effort, aimed at developing new types of THz low noise receivers, based on bulk effect ('hot electron') nonlinearities in the Two-Dimensional Electron Gas (2DEG) Medium, and the inclusion of such receivers in focal plane arrays. 2DEG hot electron mixers have been demonstrated at 35 and 94 GHz with three orders of magnitude wider bandwidth than previous hot electron mixers, which use bulk InSb. The 2DEG mixers employ a new mode of operation, which was invented during this program. Only moderate cooling is required for this mode, to temperatures in the range 20-77 K. Based on the results of this research, it is now possible to design a hot electron mixer focal plane array for the THz range, which is anticipated to have a DSB receiver noise temperature of 500-1000K. In our work on this grant, we have found similar results the the Cronin group (resident at the University of Bath, UK). Neither group has so far demonstrated heterodyne detection in this mode, however. We discovered and explored some new effects in the magnetic field mode, and these are described in the report. In particular, detection of 94 GHz and 238 GHz, respectively, by a new effect, 'Shubnikov de Haas detection', was found to be considerably stronger in our materials than the cyclotron resonance detection. All experiments utilized devices with an active 2DEG region of size of the order of 10-40 micrometers long, and 20-200 micrometers wide, formed at the heterojunction between AlGaAs and GaAs. All device fabrication was performed in-house. The materials for the devices were also grown in-house, utilizing OMCVD (Organo Metallic Chemical Vapor Deposition). In the course of this grant, we developed new techniques for growing AlGaAs/GaAs with mobilities equalling the highest values published by any laboratory. We believe that the field of hot electron mixers and detectors will grow substantially in importance in the next few years, partly as a result of the opportunity given us through this grant, which represents the major effort in the US so far. We note, however, that parallel research on hot electron mixers in thin film superconductors in Russia, and recently in Sweden, have demonstrated mixing up to 1 THz, with the potential for low-noise receivers for frequencies up to many THz. The three groups recently assessed the relative adtantages of 2DEG and superconducting film mixers in a joint paper (Kollberg et al., 1992; see Appendix II).

Yngvesson, K. Sigfrid↗

Low Offset and Noise in High Biased GaN 2DEG Hall-Effect Plates Investigated With Infrared Microscopy

This article presents GaN two-dimensional electron gas (2DEG) Hall plates with low residual offset and noise at 3 V input bias. We studied devices made from three consecutive fabrication generations through current spinning offset measurements in a zero-field chamber. When operated above 1 V, the first-generation devices charted high residual offsets >1 mT. We reduced these residual offsets by three orders of magnitude in later device generations. Two experiments were performed to confirm the improvements. First, the GaN 2DEG Hall-effect plates were measured with infrared microscopy during current spinning to investigate current crowding and Joule heating. The low offset devices had minimal thermal gradients while the high offset devices had large thermal variations during current spinning. Second, zero-field current spinning was used to compare GaN 2DEG Hall-effect plates against typical commercial silicon Hall-effect plates. The Si devices had residual offsets >10μT biased at 3 V and AlGaN/GaN devices had residual offset <4 μT at 3 V, and an InAlN/GaN devices operated at 2 V had a residual offset <4 μT . Thus, for the first time, GaN 2DEG Hall-effect plates were shown to operate with high bias with low offsets and noise, which enables high fidelity sensing applications in extreme environments.

2DEG↗

A Portable Infrasonic Detection System

During last couple of years, NASA Langley has designed and developed a portable infrasonic detection system which can be used to make useful infrasound measurements at a location where it was not possible previously. The system comprises an electret condenser microphone, having a 3-inch membrane diameter, and a small, compact windscreen. Electret-based technology offers the lowest possible background noise, because Johnson noise generated in the supporting electronics (preamplifier) is minimized. The microphone features a high membrane compliance with a large backchamber volume, a prepolarized backplane and a high impedance preamplifier located inside the backchamber. The windscreen, based on the high transmission coefficient of infrasound through matter, is made of a material having a low acoustic impedance and sufficiently thick wall to insure structural stability. Close-cell polyurethane foam has been found to serve the purpose well. In the proposed test, test parameters will be sensitivity, background noise, signal fidelity (harmonic distortion), and temporal stability. The design and results of the compact system, based upon laboratory and field experiments, will be presented.

Shams, Qamar A.↗

Ferromagnetic resonances in single-crystal yttrium iron garnet nanofilms fabricated by metal-organic decomposition

Tunable microwave and millimeter wave oscillators and bandpass filters with ultra-low phase noise play a critical role in electronic devices, including wireless communication, microelectronics, and quantum computing. Magnetic materials, such as yttrium iron garnet (YIG), possess ultra-low phase noise and a ferromagnetic resonance tunable up to tens of gigahertz. Here, we report structural and magnetic properties of single-crystal 60 and 130 nm-thick YIG films prepared by metal-organic decomposition epitaxy. These films, consisting of multiple homoepitaxially grown monolayers, are atomically flat and possess magnetic properties similar to those grown with liquid-phase epitaxy, pulsed laser deposition, and sputtering. Our approach does not involve expensive high-vacuum deposition systems and is a true low-cost alternative to current commercial techniques that have the potential to transform the industry.

Wang, Szu-Fan (Paul)↗

Numerical evaluation of the performance of active noise control systems

This paper presents a generalized numerical technique for evaluating the optimal performance of active noise controllers. In this technique, the indirect BEM numerical procedures are used to derive the active noise controllers for optimal control of enclosed harmonic sound fields where the strength of the noise sources or the description of the enclosure boundary may not be known. The performance prediction for a single-input single-output system is presented, together with the analysis of the stability and observability of an active noise-control system employing detectors. The numerical procedures presented can be used for the design of both the physical configuration and the electronic components of the optimal active noise controller.

Mollo, C. G.↗

Molybdenum Contacts to MoS 2 Field‐Effect Transistors: Schottky Barrier Extraction, Electrical Transport, and Low‐Frequency Noise

MoS 2 has great interest for nanoscale electronic devices, including transistors and sensors. Defect‐free structure, clean interface with the gate dielectric, and metals with suitable metal–semiconductor junctions are key for reliable devices. Molybdenum is shown as an excellent electrode for MoS 2 field‐effect transistors (FETs), but the correlation among device current, field‐effect mobility, and the low‐frequency noise (LFN) with number of atomic layers is not studied. Furthermore, the impact of Mo/MoS 2 Schottky barrier on electronic injection and scattering in the device needs to be understood. Herein, by studying the FETs with channels of different numbers of atomic‐layer thicknesses, it is shown that a molybdenum metal contact to MoS 2 provides reliable current injection with low Schottky barrier height, low contact resistance, low electron–phonon scattering, and negligible impurity scattering. The mobility and LFN are optimal at a channel thickness of ≈12 atomic layers, which is consistent with the “mobility maximum window” in MoS 2 transistors with prior studies using other contact metals.

Kwon, Jiseok↗

Viking S-band Doppler RMS phase fluctuations used to calibrate the mean 1976 equatorial corona

Viking S-band Doppler RMS phase fluctuations (noise) and comparisons of Viking Doppler noise to Viking differenced S-X range measurements are used to construct a mean equatorial electron density model for 1976. Using Pioneer Doppler noise results (at high heliographic latitudes, also from 1976), an equivalent nonequatorial electron density model is approximated.

Berman, A. L.↗

Auroral plasma waves

A review is given of auroral plasma wave phenomena, starting with the earliest ground-based observations and ending with the most recent satellite observations. Two types of waves are considered, electromagnetic and electrostatic. Electromagnetic waves include auroral kilometric radiation, auroral hiss, ELF noise bands, and low-frequency electric and magnetic noise. Electrostatic waves include upper hybrid resonance emissions, electron cyclotron waves, lower hybrid waves, ion cyclotron waves and broadband electrostatic noise. In each case, a brief overview is given describing the observations, the origin of the instability, and the role of the waves in the physics of the auroral acceleration region.

Gurnett, Donald A.↗

Cooled Low-Noise HEMT Microwave Amplifiers

Prototype cooled low-noise microwave amplifiers based on high-electron-mobility transistors (HEMT's) considered as replacements for cooled ruby masers used as low-noise receiver-front-end amplifiers in communications, radio science, radar systems, radio astronomy, and telemetry. HEMT amplifier operates at 12 K, requires less cooling power and operates at lower cost with simpler, more-reliable cooling system.

Bautista, J. Javier↗