Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

NASA Tech Briefs, April 2004

Topics covered include: Analysis of SSEM Sensor Data Using BEAM; Hairlike Percutaneous Photochemical Sensors; Video Guidance Sensors Using Remotely Activated Targets; Simulating Remote Sensing Systems; EHW Approach to Temperature Compensation of Electronics; Polymorphic Electronic Circuits; Micro-Tubular Fuel Cells; Whispering-Gallery-Mode Tunable Narrow-Band-Pass Filter; PVM Wrapper; Simulation of Hyperspectral Images; Algorithm for Controlling a Centrifugal Compressor; Hybrid Inflatable Pressure Vessel; Double-Acting, Locking Carabiners; Position Sensor Integral with a Linear Actuator; Improved Electromagnetic Brake; Flow Straightener for a Rotating-Drum Liquid Separator; Sensory-Feedback Exoskeletal Arm Controller; Active Suppression of Instabilities in Engine Combustors; Fabrication of Robust, Flat, Thinned, UV-Imaging CCDs; Chemical Thinning Process for Fabricating UV-Imaging CCDs; Pseudoslit Spectrometer; Waste-Heat-Driven Cooling Using Complex Compound Sorbents; Improved Refractometer for Measuring Temperatures of Drops; Semiconductor Lasers Containing Quantum Wells in Junctions; Phytoplankton-Fluorescence-Lifetime Vertical Profiler; Hexagonal Pixels and Indexing Scheme for Binary Images; Finding Minimum-Power Broadcast Trees for Wireless Networks; and Automation of Design Engineering Processes.

Source record↗

Noble Liquid Test Facility at Fermilab

The Noble Liquid Test Facility (NLTF) at Fermilab is a liquid argon detector R\&D facility open to the national and international HEP community. The facility consists of 4 permanent cryostats, ranging from 250L up to 3000L, open space for small open dewar testing, and an optical test stand facility capable of measuring the optical properties of materials and characterizing photon detectors. NLTF’s strongest advantage is its capability to provide ultra-pure LAr in a reliable manner. Its inline filters are capable of filtering all of the three biggest contaminants for standard LAr detectors, O$_2$ and H$_2$O down to $< 1$ppb and N$_2$ $< 1$ppm. This is critical for the users of the test stands as small levels of impurities can dramatically change the efficiency of LArTPCs for the collection of charge and light. The smallest cryostat is mainly used for material testing, a service provided to the international HEP community interested in understanding how the introduction of a specific material might affect the electron lifetime in LAr. The test stands can be equipped with a purity monitor, which allows measuring the electron lifetime in real time, as well as gas sampling and analyzing, and in the near future, local recirculation and filtering. The facility has hosted many successful R\&D projects, which have published their results in well-known journals and talks. A few examples of such projects are: NIR light production in LAr and GAr, the characterization of VUV metalenses, the testing of new filter media capable of filtering N$_2$ from LAr, high voltage studies and direct charge amplification in LAr, and various doping studies.

Blaszczyk, Flor María [Fermilab]↗

High-Performance Wireless Telemetry

Prior technology for machinery data acquisition used slip rings, FM radio communication, or non-real-time digital communication. Slip rings are often noisy, require much space that may not be available, and require access to the shaft, which may not be possible. FM radio is not accurate or stable, and is limited in the number of channels, often with channel crosstalk, and intermittent as the shaft rotates. Non-real-time digital communication is very popular, but complex, with long development time, and objections from users who need continuous waveforms from many channels. This innovation extends the amount of information conveyed from a rotating machine to a data acquisition system while keeping the development time short and keeping the rotating electronics simple, compact, stable, and rugged. The data are all real time. The product of the number of channels, times the bit resolution, times the update rate, gives a data rate higher than available by older methods. The telemetry system consists of a data-receiving rack that supplies magnetically coupled power to a rotating instrument amplifier ring in the machine being monitored. The ring digitizes the data and magnetically couples the data back to the rack, where it is made available. The transformer is generally a ring positioned around the axis of rotation with one side of the transformer free to rotate and the other side held stationary. The windings are laid in the ring; this gives the data immunity to any rotation that may occur. A medium-frequency sine-wave power source in a rack supplies power through a cable to a rotating ring transformer that passes the power on to a rotating set of electronics. The electronics power a set of up to 40 sensors and provides instrument amplifiers for the sensors. The outputs from the amplifiers are filtered and multiplexed into a serial ADC. The output from the ADC is connected to another rotating ring transformer that conveys the serial data from the rotating section to the stationary section. From there, a cable conveys the serial data to the remote rack, where it is reconditioned to logic level specifications, de-serialized, and converted back to analog. In the rotating electronics are code generators to indicate the beginning of files for data synchronization.

Griebeler, Elmer↗

Analyzing LF/VLF Lightning Waveforms to Estimate D-region Electron Density Profiles

Lightning waveforms in the low frequency (LF; 30-300 kHz) and the very low frequency (VLF; 3-30 kHz) bands can be exploited to produce data-driven ionospheric D-region electron density profile (EDP) estimates with significantly higher spatial and temporal coverage than previously available. The lightning waveforms used in this paper are signals detected in the LF/VLF of negative cloud-to-ground lightning by the Earth Networks Total Lightning Detection Network. Each waveform contains a ground wave and a time-delayed ionospheric reflection. The time delay between the ground wave and ionospheric reflection has previously been used to estimate a single specular reflection altitude, where LF/VLF emissions are reflected by the ionosphere. Here, we expand upon previous methods to include filtering and spectral analysis, and account for oblique propagation to produce higher-order estimates for reflection altitudes and corresponding electron densities. Once estimated, reflection altitudes and corresponding electron densities can be used to derive parameters β and h’, which define an EDP for the D-region. In this study, the lightning waveform (LW) analysis is demonstrated using a single representative 24-hour dataset over the Southeast United States, and then extended to a total of 10 separate datasets with varying locations and ionospheric conditions. The LW-derived D-region EDPs are in agreement with predictions made by the Faraday International Reference Ionosphere model, and the LW EDPs β and h’ values are consistent with previous LF/VLF-derived estimates.

D-region ionosphere↗

Jefferson Laboratory C100 Superconducting Radio-Frequency Cavity Fault Data, 2020

The dataset was created to train machine learning models for the task of identifying the (1) cavity and (2) fault type from C100-type cryomodules at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), thereby replacing the time-consuming efforts of a subject matter expert. Superconducting radio-frequency (SRF) cavity trips represent a significant source of accelerator downtime. Real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type would give control room operators valuable feedback for corrective action planning. The anticipated benefit is increased beam-on-target time for users and provides performance metrics that can be used to improve future cavity designs. A series of 17 RF signals are recorded for each of the 8 cavities in a C100 cryomodule every time a cavity trips. These time-series signals are written to file using a specially designed data acquisition system. The dataset represents fault events recorded during Continuous Electron Beam Accelerator Facility (CEBAF) beam operations between January 18, 2019 and March 9, 2020. The following filtering steps were applied to collected data; (1) only 4 of the 17 signals per cavity are retained (GMES, GASK, CRFP, DETA2) (2) only events with data from each of the eight cavities in the cryomodule are kept, (3) only events that were sampled at 5 kHz were kept, (4) events from cryomodule 0L04 were neglected, (5) events occurring between February 4, 3PM and February 5, 12PM were neglected. As a result of preprocessing, the dataset is comprised of 2,375 unique events. The full dataset is comprised of three files: features.csv, cavity_labels.csv, fault_labels.csv. Each instance in faults.csv includes a timestamp (“date_time”), a label for the cryomodule which experienced the trip (“zone_label”), and 192 features (“feature_1”, “feature_2”... “feature_192”). The features correspond to 6 autoregressive features for each of 4 signals per cavity for each of the 8 cavities (6 × 4 signals/cavity × 8 cavities/cryomodule = 192). To deal with the large variation of signal amplitudes, time-series standardization via the z-score (standard score) function was applied prior to computing the features. For each instance, there is an associated label for the (1) cavity which faulted first (cavity_labels.csv) and (2) the type of fault that caused the trip (fault_labels.csv). The cavity identification can take values of [0, 1, 2, 3, 4, 5, 6, 7, 8] and the fault type can take values of [‘Microphonics’, ‘Quench_100ms’, ‘Controls_Fault’, ‘E_Quench’, ‘Quench_3ms’, ‘Single_Cav_Turn_Off’ , ‘Heat_Riser_Choke’, ‘Multi_Cav_Turn_Off’].

43 PARTICLE ACCELERATORS↗

The solar flare iron line to continuum ratio and the coronal abundances of iron and helium

Narrow band Ross filter measurements of the Fe 25 line flux around 0.185 nm and simultaneous broadband measurements during a solar flare were used to determine the relationship between the solar coronal abundances of iron and helium. The Fe 25 ion population was also determined as a function of time. The proportional counter and the Ross filter on OSO-7 were utilized. The data were analyzed under the separate assumptions that (1) the electron density was high enough that a single temperature could characterize the continuum spectrum and the ionization equilibrium, and that (2) the electron density was low so that the ion populations trailed the electron temperature in time. It was found that the density was at least 5x10 to the 9th power, and that the high density assumption was valid. It was also found that the iron abundance is 0.000011 for a helium abundance of 0.2, relative to hydrogen.

Mckenzie, D. L.↗

Magnetic Field Investigation for ISEE mother and daughter spacecraft

Highlights of the design and fabrication of fluxgate magnetometers for the ISEE A and B satellites which were launched from a single launch vehicle into the same highly elliptical orbit are presented. The instrument consisted of four basic assemblies: the sensors, the drive and sense electronics, the data handling unit; and the flipper. The digital handling data handling assembly contained a digital filter that mantained a uniform transfer function for all three axes of both spacecraft. Initial studies centered on the bow shock and the magnetopause and show that both boundaries are in rapid motion. The bow shock was found to be very thin, close to an ion inertial length in thickness, but the magnetopause was much thicker than expected, about 400 to 1000 km on average. The magnetometers have each logged over 3 2/3 years of continuous operation.

Russell, C. T.↗

Helicopter Airborne Laser Positioning System (HALPS)

The theory of operation, configuration, laboratory, and ground test results obtained with a helicopter airborne laser positioning system developed by Princeton University is presented. Unfortunately, due to time constraints, flight data could not be completed for presentation at this time. The system measures the relative position between two aircraft in three dimensions using two orthogonal fan-shaped laser beams sweeping across an array of four detectors. Specifically, the system calculates the relative range, elevation, and azimuth between an observation aircraft and a test helicopter with a high degree of accuracy. The detector array provides a wide field of view in the presence of solar interference due to compound parabolic concentrators and spectral filtering of the detector pulses. The detected pulses and their associated time delays are processed by the electronics and are sent as position errors to the helicopter pilot who repositions the aircraft as part of the closed loop system. Accuracies obtained in the laboratory at a range of 80 ft in the absence of sunlight were + or - 1 deg in elevation; +0.5 to -1.5 deg in azimuth; +0.5 to -1.0 ft in range; while elevation varied from 0 to +28 deg and the azimuth varied from 0 to + or - 45 deg. Accuracies in sunlight were approximately 40 deg (+ or - 20 deg) in direct sunlight.

Eppel, Joseph C.↗

Acousto-optical Filter Can Rapidly Tune Solid-State Lasers

Incorporation of acousto-optical tunable filter (AOTF) in cavity of solid-state laser, provides means of adjusting wavelength of laser output electronically, according to recent proposal. Output wavelength randomly selected in microseconds. Technique useful in remote-sensing applications, such as in differential-absorption lidar (DIAL) and in communications for wavelength-division multiplexing.

Lambert, James L.↗

Helicopter Airborne Laser Positioning System (HALPS)

The theory of operation, configuration, laboratory, and ground test results obtained with an HALPS developed by Princeton University is presented. The HALPS measures the relative position between two aircraft in three dimensions using two orthogonal fan-shaped laser beams sweeping across an array of four detectors. Specifically, the HALPS calculates the relative range, elevation, and azimuth between an observation aircraft and a test helicopter with a high degree of accuracy. The detector array provides a wide field of view in the presence of solar interference due to compound parabolic concentrators and spectral filtering of the detector pulses. The detected pulses and their associated time delays are processed by the electronics and are sent as position errors to the helicopter pilot who repositions the aircraft as part of the closed loop system. Accuracies obtained in the laboratory at a range of 80 ft in the absence of sunlight were + or - 1 deg in elevation; +0.5 to -1.5 deg in azimuth; +0.5 to -1.0 ft in range; while elevation varied from 0 to +28 deg and the azimuth varied from 0 to + or - 45 deg. Accuracies in sunlight were approximately 40 deg (+ or - 20 deg) in direct sunlight.

Eppel, Joseph C.↗

Fiber-Coupled Acousto-Optical-Filter Spectrometer

Fiber-coupled acousto-optical-filter spectrometer steps rapidly through commanded sequence of wavelengths. Sample cell located remotely from monochromator and associated electronic circuitry, connected to them with optical fibers. Optical-fiber coupling makes possible to monitor samples in remote, hazardous, or confined locations. Advantages include compactness, speed, and no moving parts. Potential applications include control of chemical processes, medical diagnoses, spectral imaging, and sampling of atmospheres.

Levin, Kenneth H.↗

Atmospheric measurements of carbonyl sulfide, dimethyl sulfide, and carbon disulfide using the electron capture sulfur detector

Measurements of atmospheric dimethyl sulfide (DMS), carbonyl sulfide (COS), and carbon disulfide (CS2) were conducted over the Atlantic Ocean on board the NASA Electra aircraft during the Chemical Instrumentation Test and Evaluation (CITE 3) project using the electron capture sulfur detector (ECD-S). The system employed cryogenic preconcentration of air samples, gas chromatographic separation, catalytic fluorination, and electron capture detection. Samples collected for DMS analysis were scrubbed of oxidants with NaOH impregnated glass fiber filters to preconcentration. The detection limits (DL) of the system for COS, DMS, and CS2 were 5, 5, and 2 ppt, respectively. COS concentrations ranged from 404 to 603 ppt with a mean of 489 ppt for measurements over the North Atlantic Ocean (31 deg N to 41 deg N), and from 395 to 437 ppt with a mean of 419 ppt for measurements over the Tropical Atlantic Ocean (11 deg S to 2 deg N). DMS concentrations in the lower marine boundary layer, below 600-m altitude, ranged from below DL to 150 ppt from flights over the North Atlantic, and from 9 to 104 ppt over the Tropical Atlantic. CS2 concentrations ranged from below DL to 29 ppt over the North Atlantic. Almost all CS2 measurements over the Tropical Atlantic were below DL.

Johnson, James E.↗

Flue-Gas Desulfurization Effluent Management using an Innovative Low-Energy Biosorpotion Treatment System to Remove Key Contaminants

Among the most critical water contaminants of concern affecting wide geographical regions and a number of industries and natural systems is selenium. Selenium found in surface, ground and wastewater in originates from natural sources, as well as industrial sources such as petroleum refineries, electronics manufacturing, pesticides, and coal power plants and mining also contribute to selenium contamination in water in the US. At high concentrations, selenium is toxic to human and wildlife. There are a number of technologies that have been used to treat selenium and other similar contaminants in water. Biological treatment of selenium has been used in the past to reduce soluble SeVI and/or SeIV to insoluble Se0, which is then filtered in the same vessel. The insoluble selenium (Se0) is then backwashed from the system and solids are separated for subsequent disposal, if they meet the leaching and water content criteria. In order to promote biological reduction to insoluble Se0, heating of bioreactor is needed in some applications, and excess food source (electron donor) is added so that all selenium can be filtered. An additional disadvantage of these systems is the significant amount of water lost due to extensive and frequent backwash and rinse cycles. When comparing the advantages and energy requirements of the various treatment technologies, RO membrane filtration immediately stands out due to the excessive energy expenditure needed to pump water across the membrane although RO is an effective way to remove selenium. In addition, RO requires extensive pretreatment, such as MF membrane, and frequent maintenance, rendering it an expensive option that may be out of reach for certain applications. In fact, although the performance was good during the pilot testing by the NSMP Working Group for treatment naturally occurring selenium in the surface water, the high electricity requirements and significant reject water stream made it an infeasible alternative. While conventional ion exchange maybe an effective treatment option, it requires frequent regeneration of the resin when applied to highly contaminated water, which leads to several tons of contaminant-laden, high-salinity brine that needs to be disposed off-site each day. One of the water systems in the west coast currently uses ion exchange for selenium treatment and has been trucking selenium laden hazardous brine waste weekly in the last several years. Pneumatic pumping and rinse water pumping required for ion exchange also increase the energy usage. In comparison, adsorption process is a passive treatment system where contaminated water comes in contact with an adsorption media in a vessel. Typically, there is no mixing, backwash, or recycle pumping required, thus significantly reducing the energy usage. A passive single-use adsorption system does not require backwash, thereby generating small amount of process waste, and producing the highest water yield among the alternatives. The energy and water efficiencies, and applicability for SeVI and SeIV are summarized in Table 1. Despite these benefits though, adsorption typically does not work for the most oxidized form of selenium (SeVI). The innovative biosorption process integrates both process to increase the treatment efficiency while minimizing energy, chemical, and time required to treat both SeVI and SeIV. Additional advantages include simple partial biological reduction with reduced on-site waste generation, which lead to water and electricity savings, and less operational need compared to biological treatment alone. This makes biosorption especially suitable for remote areas, where liquid backwash and brine disposal may be cost prohibitive or infeasible.

20 FOSSIL-FUELED POWER PLANTS↗

Assessment of filtered cameras for quantitative 2D analysis of divertor conditions during detachment in JET L-mode plasmas

We report that estimates for 2D distributions of electron temperature, T e , electron density, n e , and atomic deuterium density, n o , in the JET divertor volume have been inferred from deuterium Balmer line intensity ratios obtained from tomographic reconstructions of divertor camera measurements. This enables also investigation of ionization, S ion , and recombination, S rec , rates. The analysis shows a decrease of T e to 0.5–1.0 eV throughout the outer divertor during detachment in low-confinement (L-mode) plasmas. Simultaneously, the high-n e region and the n 0 distribution in the outer divertor are observed to elongate and shift from the outer strike point towards the X-point. The observations are in qualitative agreement and follow the same sequence with modelling predictions of EDGE2D-EIRENE simulations of a density scan. While the method was found to provide good representation of the evolution of volumetric recombination during detachment, in agreement with the simulations, the movement of the ionization front upstream could not be followed due to lack of spatial overlap between the ionization region and the necessary emission distributions. Consequently, the representation of the ionization conditions and the particle balance in the detached outer divertor are compromised.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Mimas ghost revisited - An analysis of the electron flux and electron microsignatures observed in the vicinity of Mimas at Saturn

An analysis of the electron-absorption signature observed by the cosmic-ray system on Voyager 2 near the orbit of Mimas is presented. It is found that these observations cannot be explained as the absorption signature of Mimas. By combining Pioneer 11 and Voyager 2 measurements of the electron flux at Mimas's orbit (L = 3.1), an electron spectrum is found in which most of the flux above about 100 keV is concentrated near 1 to 3 MeV. This spectral form is qualitatively consistent with the bandpass filter model of Van Allen et al. (1980). The expected Mimas absorption signature is calculated from this spectrum neglecting radial diffusion. Since no Mimas absorption signature was observed in the inbound Voyager 2 data, a lower limit on the diffusion coefficient for MeV electrons at L = 3.1 of D greater than 10 to the -8th sq Saturn radii/sec is obtained. With a diffusion coefficient this large, both the Voyager 2 and the Pioneer 11 small-scale electron-absorption-signature observations in Mimas's orbit are enigmatic. Thus the mechanism for producing these signatures is referred to as the Mimas ghost. A cloud of material in orbit with Mimas may account for the observed electron signature if the cloud is at least 1-percent opaque to electrons across a region extending over a few hundred kilometers.

Chenette, D. L.↗

Very Long-Wavelength GaAs/AlxGa1-xAs Infrared Hot Electron Transistor

We have demonstrated a bound to continuum state GaAs/AlxGa1-xAs infrared hot electron transistor which has a peak response at (sub =16.3). This device utilizes a bound-to-continuum quantum well infrared photodetector as a photosensitive emitter and a wide AlxGa1-xAs barrier between the base and the collector as an energy discriminating filter.

infrared hot electron transistor photosensitive em↗

Results of critical velocity experiments with barium, strontium, and calcium releases from CRRES satellite

As part of the NASA Combined Release and Radiation Effects Satellite (CRRES) chemical release program in September 1990, two Ba and also one each Sr and Ca canisters of a boron-titanium thermite mixture, which vaporizes the element on ignition, were released near perigee after dusk in the South Pacific to study the critical velocity effect proposed by Alfven. The critical velocities of these three elements are 2.7, 3.5, and 5.4 km/s respectively, all well below the orbital velocity of 9.4 km/s. On September 10, 1990, a Sr and Ba pair (G-13, or critical ionization velocity (CIV) I) was released near Rarotonga at approximately 515 km altitude in a background electron density of 3.4 x 10(exp 6)/cu cm. On September 14, 1990, G-14 or CIV II released a Ca and Ba pair west of New Caledonia near 595 km at an electron density of 1.5 x 10(exp 6)/cu cm. Ions of all three elements were observed with low-light level imagers from two aircraft after they had transited up the magnetic field lines into the sunlight. Emissions from the spherically expanding neutral gas shells below the solar terminator, observed with cameras filtered for the Ba(+) ion line at 4554 A and also in unfiltered imagers for approximately 15 s after release, are probably due to excitation by hot electrons created in the CIV process. The ions created clearly lost much of their energy, which we now show can be explained by elastic collisions: Ba(+) + O. Inventories of the observed ions indicate yields of 0.15% and 1.84% for Ba in the first and second experiments, 0.02% for Sr and 0.27% for Ca. Ionization from all the releases continued along the satellite trajectory much longer (greater than 45 s) than expected for a CIV process. The ion production along the satellite track versus time typically shows a rapid rise to a peak in a few seconds followed by an exponential decrease to a level essentially constant rate. The characteristic distances for CIV I and II are 47 and 62 km, respectively. We interpret the early time rise and exponential fall to be due to CIV ionization, of 0.014% (CIV I) and 0.40% (CIV II) for the Ba releases. The later ions produced at a constant rate probably have origins from other such processes as stripping and associative ionization collisions with atmospheric constituents primarily O, and charge exchange with O(+), He(+), and H(+). We suggest that the much larger Ba ionization rate in CIV II than CIV I is due to the fact that the release occurred in the peak Ca density where hot electrons were already present.

Wescott, E. M.↗

Ionospheric Electron/Ion Densities Temperatures on CD-ROM and WWW

As part of this project a large volume of ionospheric satellite insitu data from the sixties, seventies and early eighties were made accessible online in ASCII format for public use. This includes 14 data sets from the BE-B, Alouette 2, DME-A, AE-B, ISIS-1, ISIS-2, OGO-6, DE-2, AEROS-A, AE-C, AE-D, AE-E, and Hinotori satellites. The original data existed in various machine-specific, highly compressed, binary encoding on 7-, or 9-track magnetic tapes. The data were decoded and converted to a common ASCII data format, solar and magnetic indices were added, and some quality control measures were taken. The original intent of producing CD-ROMs with these data was overtaken by the rapid development of the Internet. Most users now prefer to obtain the data directly online and greatly value WWW-interfaces to browse, plot and subset the data. Accordingly the data were made available online on the anonymous ftp site of NASA's National Space Science Data Center (NSSDC) at ftp://nssdcftp.gsfc.nasa.gov/spacecraft data/ and on NSSDC's ATMOWeb (http://nssdc.gsfc.nasa.gov/atmoweb/), a WWW-interface for plotting, subsetting, and downloading the data. Several new features were implemented into ATMOWeb as part of this project including a filtering and scatter plot capability. The availability of this new database and WWW system was announced through several electronic mailer (AGU, CEDAR, IRI, etc) and through talks and posters during scientific meetings.

Bilitza, Dieter↗