Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Hybrid MEMS-CMOS ion traps for NISQ computing

Surging interest in engineering quantum computers has stimulated significant and focused research on technologies needed to make them manufacturable and scalable. In the ion trap realm this has led to a transition from bulk three-dimensional macro-scale traps to chip-based ion traps and included important demonstrations of passive and active electronics, waveguides, detectors, and other integrated components. At the same time as these technologies are being developed the system sizes are demanding more ions to run noisy intermediate scale quantum (NISQ) algorithms, growing from around ten ions today to potentially a hundred or more in the near future. To realize the size and features needed for this growth, the geometric and material design space of microfabricated ion traps must expand. In this paper we describe present limitations and the approaches needed to overcome them, including how geometric complexity drives the number of metal levels, why routing congestion affects the size and location of shunting capacitors, and how RF power dissipation can limit the size of the trap array. Finally, we also give recommendations for future research needed to accommodate the demands of NISQ scale ion traps that are integrated with additional technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NO$\nu$A Far Detector $\nu_e$ Sideband Study Technical Note

Till now the NO$\nu$A experiment has used the Far Detector (FD) electron neutrino (anti-neutrino) events in the energy range 1 < $E_ν$ < 4 GeV in 3-favor neutrino oscillation analysis, to constraint the neutrino oscillation parameters. In this study, we have used the high-energy neutrino (sideband) sample with 4 < $E_ν$ < 12 GeV, dominated heavily by the beam electron neutrino/anti-neutrino background events to constrain the neutrino oscillation parameters. This was done to figure out if an additional power can be obtained in constraining the oscillation parameters by adding this sample to the analysis. This technote discusses the modifications done in the existing framework to add the sideband sample to the standard FD $\nu_e$ predictions and its impact on the neutrino oscillation parameters sensitivity of the NO$\nu$A experiment. Results from the statistics only study and the study including all the existing systematic shifts are reported separately.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plutonium Basket Counter Measurement Control Q3-Q4 2023

The Plutonium Basket Counter (PBC) is a spent fuel nuclear safeguards instrument that was developed to measure spent-fuel elements from MAGNOX-type research reactors and determine their plutonium content. The instrument is designed to measure fuel elements in spent fuel cooling pools through underwater operation, but it is also able to measure radiation sources in air. The PBC determines fuel plutonium content by detecting neutrons with an array of Helium-3 detectors. The electronics make use of a JSR-15 shift register for data collection and IAEA Neutron Coincidence Counting (INCC) software for data analysis. The PBC is used to determine the 240 Pu content in spent MAGNOX fuel elements grouped into basket-like bundles, thus the instrument’s name. Reactor burnup calculations can be used in conjunction with the data from the PBC to estimate the total plutonium content in the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Research in Neutrino Physics (Final Technical Report)

The goal of the experimental neutrino efforts at Louisiana State University is to measure the properties of neutrinos and to improve our understanding of neutrino interactions. In pursuit of this goal, the group will continue its Intensity Frontier work on the DUNE experiment at Fermilab and the T2K experiment at J-PARC, Japan. The current work is focused on understanding how neutrinos change flavor and on the possibility for asymmetry between neutrinos and anti-neutrinos. The effort on T2K includes physics measurements using the collected T2K data and preparation for the second phase T2K-II data with an increased beam power and the newly upgraded ND280 detector, featuring a novel 3D fine grained scintillation tracker with 4π acceptance and 3D readout. T2K is in a position to improve our understanding of neutrino nucleus interactions which continue to be one of the largest systematic uncertainties for neutrino oscillation measurements. On DUNE, the effort is on analyzing the data collected by the ProtoDUNE-SP prototype at CERN and on the design, installation, and commissioning of ProtoDUNE-II and later the DUNE Far Detector cold electronics. The final DUNE Module-1 components will be fully characterized by ProtoDUNE-II and the collected data will be used to improve and tune simulation and reconstruction algorithms, and to measure hadron scattering cross section, used to improve the modeling of neutrino final state interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A system for early warning of bearing failure

System for detecting incipient failure in ball bearings is described. Ultrasonic equipment detects bearing system resonance and provides warning signal through electronic circuitry. Detector can be used to evaluate performance of newly installed bearings. Schematic diagram is provided to show components.

Broderick, J. J.↗

An all-sky X-ray monitor for the UK-5 satellite.

An X-ray imaging system using a pin-hole camera and a position sensitive proportional counter at the image plane has been designed for an all-sky X-ray monitor for UK-5 satellite. This high-sensitivity device with real-time coverage of the entire celestial sphere would aid in programming satellite maneuvers such that transient events in the X-ray sky could be investigated in detail by the other primary satellite experiments. Discussion of design criteria for the camera geometry, the position sensitive proportional detector, and electronics to handle the data is presented in this paper.

Desai, U. D.↗

The response of covered silicon detectors to monoenergetic gamma rays.

Measurements have been made of the efficiency in detecting gamma rays of a 0.3-mm-, 3-mm-, and 5-mm-thick silicon detector covered with different absorbers. Calibrated sources over the range from 279 keV to 2.75 MeV were used. The need for the absorbers to obtain meaningful results and their contribution to the response of the detectors at electron biases from 50 to 200 keV are discussed in detail. It is shown that the results are virtually independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias settings is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

Design and performance characteristics of the Vertical Temperature Profile Radiometer /VTPR/ for atmospheric temperature soundings.

Description of the design and operation of a radiometer which derives atmospheric temperature profiles on the basis of spectral measurements in eight optical filter channels. The radiometer achieves its eight-channel capability by sequentially viewing the eight optical filters mounted in a rotating filter wheel, with a single IR detector and electronic amplification channel processing the signal for all the filters. The advantages and disadvantages of this sequential approach as compared to eight 'parallel' radiometric channels are discussed. The proposed radiometer provides a relative calibration accuracy between seven out of the eight channels of better than 0.1% rms of the full dynamic range. The absolute accuracy achievable between in-flight calibrations of six minutes, or between two-hour calibrations using optical temperature correction factors, is better than an rms value of 0.15% of full scale. The radiometric correlation between the in-flight calibration source of the instrument and a reference standard blackbody is better than an rms value of 0.5% of full scale.

Falbel, G.↗

N2O analysis in the atmosphere via electron capture-gas chromatography

The potential of commercially available pulse-modulated electron capture detector (ECD)-equipped gas chromatographs for direct measurement of ambient levels of N2O is assessed. Since the sensitivity of ECD to N2O is directly proportional to the detector operating temperature and detector standing current, it is necessary to use a 'hot' ECD (250-350 C). The method is shown to be very precise with a standard error not exceeding 1% for automated analysis of ambient air samples. The technology is available to permit highly accurate routine direct analysis of N2O in the troposphere and stratosphere. Both captured air samples or direct real-time measurement from research vessels or airborne platforms are possible.

Rasmussen, R. A.↗