Measurement of average electron density between 75 and 80 kilometers
Measurement of average electron density in D region
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Measurement of average electron density in D region
Precursor electron densities measured in nitrogen and air ahead of shock waves, noting shock tube wall reflectivity
Ionosphere Topside Sounder program - electron density and geomagnetic field at Alouette I orbit
The current model for the polarized brightness (pB) spectrum has a decades-long history of progressively incorporating its dependence on electron density N(e), temperature T(e), and flow velocity in the radial direction V(e). The pBNe spectrum follows the exact shape of the photosphere spectrum, which is not smooth, which is expected from the thermal Doppler broadening of the photosphere spectrum due to the high coronal T(e). The pBN(e) spectrum is smooth, but the free coronal electrons remain static and unaffected by solar wind, and the pBN(e)T(e)V(e) spectrum is red-shifted by electrons seeing a red-shifted photosphere spectrum as they flow away from the Sun as solar wind, which takes a radial direction above 2.5 R from Sun center. In this article, we review the progress of the above three model pB spectra in describing the observations and highlight the differences, first by comparing the three model pB spectra against wavelength using a model for Ne and constant values for T(e) and V (e), and second by generating three model 2D pB maps by integrating over a selected wavelength region in the three model pB spectra along lines of sight passing through the 14 July 2000 (“Bastille Day”) coronal mass ejection (CME) model, which contains 3D information on N(e), T(e), and V e. In this regard, the COronal Diagnostic EXperiment (CODEX) on the International Space Station (ISS) in 2024 will measure N(e), T(e), and V(e) by matching the measured pB with modeled pBN(e)T(e)V(e) in selected wavelength regions using multiple filters.
The current model for the polarized brightness (pB) spectrum has a decades-long history of progressively incorporating its dependence on electron density Ne, temperature Te, and flow velocity in the radial direction V e . The pB N e spectrum follows the exact shape of the photosphere spectrum, which is not smooth, which is expected from the thermal Doppler broadening of the photosphere spectrum due to the high coronal T e ; the pB N e T e spectrum is smooth, but the free coronal electrons remain static and unaffected by solar wind, and the pB N e T e V e spectrum is red-shifted by electrons seeing a red-shifted photosphere spectrum as they flow away from the Sun as solar wind, which takes a radial direction above 2.5 R ⨀ from Sun center. In this article, we review the progress of the above three model pB spectra in describing the observations and highlight the differences, first by comparing the three model pB spectra against wavelength using a model for Ne and constant values for T e and V e , and second by generating three model 2D pB maps by integrating over a selected wavelengthregion in the three model pB spectra along lines of sight passing through the 14 July 2000 (“Bastille Day”) coronal mass ejection (CME) model, which contains 3D information on N e , T e , and V e . In this regard, the COronal Diagnostic EXperiment (CODEX) on the International Space Station (ISS) in 2024 will measure N e , T e , and V e by matching the measured pB with modeled pB N e T e V e in selected wavelength regions using multiple filters.
Diurnal variation in electron densities and temperatures in F region from backscatter measurements over Puerto Rico
Purpose: For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the author previously proposed a simple conversion of the energy-subtracted computed tomography (CT) number to an electron density (ΔHU–ρ{sub e} conversion), which provides a single linear relationship between ΔHU and ρ{sub e} over a wide ρ{sub e} range. The purpose of the present study was to reveal the relation between the ΔHU image for ρ{sub e} calibration and a virtually monochromatic CT image by performing numerical analyses based on the basis material decomposition in dual-energy CT. Methods: The author determined the weighting factor, α{sub 0}, of the ΔHU–ρ{sub e} conversion through numerical analyses of the International Commission on Radiation Units and Measurements Report-46 human body tissues using their attenuation coefficients and given ρ{sub e} values. Another weighting factor, α(E), for synthesizing a virtual monochromatic CT image from high- and low-kV CT images, was also calculated in the energy range of 0.03 < E < 5 MeV, assuming that cortical bone and water were the basis materials. The mass attenuation coefficients for these materials were obtained using the XCOM photon cross sections database. The effective x-ray energies used to calculate the attenuation were chosen to imitate a dual-source CT scanner operated at 80–140 and 100–140 kV/Sn. Results: The determined α{sub 0} values were 0.455 for 80–140 kV/Sn and 0.743 for 100–140 kV/Sn. These values coincided almost perfectly with the respective maximal points of the calculated α(E) curves located at approximately 1 MeV, in which the photon-matter interaction in human body tissues is exclusively the incoherent (Compton) scattering. Conclusions: The ΔHU image could be regarded substantially as a CT image acquired with monoenergetic 1-MeV photons, which provides a linear relationship between CT numbers and electron densities.
Middle latitude changes in topside electron density during magnetic storm
Two Stark broadening parameters including FWHM (full width at half maximum) and FWHA (full width at half area) of isotope hydrogen alpha lines are simultaneously introduced to determine the electron density of a pulsed vacuum arc jet. To estimate the gas temperature, the rotational temperature of the C{sub 2} Swan system is fit to 2500 ± 100 K. A modified Boltzmann-plot method with b{sub i}-factor is introduced to determine the modified electron temperature. The comparison between results of atomic and ionic lines indicates the jet is in partial local thermodynamic equilibrium and the electron temperature is close to 13 000 ± 400 K. Based on the computational results of Gig-Card calculation, a simple and precise interpolation algorithm for the discrete-points tables can be constructed to obtain the traditional n{sub e}-T{sub e} diagnostic maps of two Stark broadening parameters. The results from FWHA formula by the direct use of FWHM = FWHA and these from the diagnostic map are different. It can be attributed to the imprecise FWHA formula form and the deviation between FWHM and FWHA. The variation of the reduced mass pair due to the non-equilibrium effect contributes to the difference of the results derived from two hydrogen isotope alpha lines. Based on the Stark broadening analysis in this work, a corrected method is set up to determine n{sub e} of (1.10 ± 0.08) × 10{sup 21} m{sup −3}, the reference reduced mass μ{sub 0} pair of (3.30 ± 0.82 and 1.65 ± 0.41), and the ion kinetic temperature of 7900 ± 1800 K.
Application of a viscous shock-layer analysis to the calculation of nonequilibrium-flow species distributions in the plasma layer of a blunt-nosed vehicle at high altitudes. The theoretical electron-density results obtained are in good agreement with those measured in flight for a hemisphere-9 deg cone entry vehicle. The flight measurements were obtained using electrostatic probes that protruded well into the shock layer. In addition, the theoretically obtained heavy-particle translational temperatures appear to agree fairly well with the electron temperatures that were measured in the flight experiments using voltage-swept thin-wire electrostatic probes. The influence of the reaction rate coefficients on the calculated electron densities has been assessed and shown to be within the uncertainty in the flight data. The theoretical results demonstrate the importance of including in the chemical model the positive ions N2(+), O2(+), N(+), and O(+), in addition to NO(+), for the high altitudes and velocities considered.
The Mars Global Surveyor (MGS) Radio Science (RS) experiment employs an ultrastable oscillator aboard the spacecraft. The signal from the oscillator to Earth is refracted by the Martian ionosphere, allowing retrieval of electron density profiles versus radius and geopotential. The present analysis is carried out on five sets of occultation measurements: (1) four obtained near northern summer solstice (Ls = 74-116, near aphelion) at high northern latitudes (64.7-77.6N), and (2) one set of profiles approaching equinox conditions (Ls = 135- 146) at high southern latitudes (64.7-69.1S). Electron density profiles (95 to 200 km) are examined over a narrow range of solar zenith angles (76.5-86.9 degrees) for local true solar times of (1) 3-4 hours and (2) 12.1 hours. Variations spanning 1-Martian year are specifically examined in the Northern hemisphere.
Shock tube tests of Langmuir probe for determining electron density and temperature surrounding reentry vehicle
Through various processes molecular nitrogen within the nocturnal auroral oval is vibrationally excited, substantially increasing the rate at which O(+) is lost via the reaction O(+) + N2* yields NO(+) + N. Owing to the action of thermospheric winds and diffusion, N2* does not remain at its point of origin but is transported to regions outside the auroral oval where it can act to substantially reduce the F-region electron density. For an equatorward transport speed of 100 m/sec, N2* can travel 3 to 4 deg of latitude before quenching with atomic oxygen substantially reduces the N2* density. This process may contribute significantly to the formation of the midlatitude F-region electron density trough.
The electron-atom neutral bremsstrahlung continuum radiation emitted from weakly ionized plasmas is investigated for electron density and temperature diagnostics. The continuum spectrum in 450–1000 nm emitted from the argon atmospheric pressure plasma is found to be in excellent agreement with the neutral bremsstrahlung formula with the electron-atom momentum transfer cross-section given by Popović. In 280–450 nm, however, a large discrepancy between the measured and the neutral bremsstrahlung emissivities is observed. We find that without accounting for the radiative H{sub 2} dissociation continuum, the temperature, and density measurements would be largely wrong, so that it should be taken into account for accurate measurement.
Upper ionospheric electron density measurement by signals propagated between two parts of high altitude rocket
Wintertime f-2 layer electron density distribution, relating ionization increase to magnetic dip, solar cycle and winter anomaly
Upper ionospheric electron density measurement by signals propagated between two parts of high altitude rocket
This work presents the hardware design and first results from a newly commissioned correlation reflectometer radiometer diagnostic that measures the cross-phase angle between electron density and temperature fluctuations in ASDEX Upgrade plasmas. This diagnostic employs cross correlations between signals measured by a tunable, continuous wave, perpendicular incidence, fluctuation reflectometer, and a 24-channel radiometer sharing the same line of sight. Novel measurements in the pedestal of a helium H-mode plasma with small edge localized modes show changes in the cross-phase angle between the electron density and temperature fluctuations from ∼90° to 120°, suggesting changes in the properties of the turbulence driving transport in the plasma edge.